Extron Cable Cubby 500 Manuel utilisateur

Catégorie
Câbles de signal
Taper
Manuel utilisateur

Ce manuel convient également à

1
IMPORTANT:
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
Cable Cubby 500 and 700 • Installation Guide
This guide provides instructions for an experienced installer to install and connect the Extron
Cable Cubby 500 and 700 Cable Access Enclosures.
The Cable Cubby units are furniture-mounted enclosures for cable access,
connections, and AC power. Cables that are not in use can be stored out of
the way while remaining connected to the presentation system.
Planning
Check with local and state regulations before starting the
installation:
Ensure that the planned installation complies with building and electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities Act or
other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit.
Ensure that necessary tools and equipment are available for the installation.
Cable Cubby 500 and Cable Cubby 500 CCB Cable Cubby 700
1 2
2 4
1 2
1 2
(3) 3/8", (1) 1/4" (6) 3/8", (2) 1/4"
1 trim, 2 screws 2 trims, 4 screws
1 2
4 8
Kit Contents
Hole Plugs
Connectivity Bracket Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500 Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
Retractor Trim
and Screws
Retractor Pin & Clip
#6 Mounting Screws
and Star Washers
#4-40 Module Screws
ii Bk
Cable Frame Plate (1)
Hole Plugs
Connectivity Bracket Cable Grommet Plate
AAP Frame Plate
Cable Cubby 500 Cable Cubby 700
Zip Ties
Tweeker
AC Power Module
125V~ 12A MAX TOTAL
Retractor Trim
and Screws
Retractor Pin & Clip
#6 Mounting Screws
and Star Washers
#4-40 Module Screws
ii Bk
Cable Frame Plate (1)
Retractor Trim
and Screws
Connectivity Bracket
#6 Mounting Screws
and Star Washers
Cable Grommet Plate
Cable Frame Plate
Zip Ties
Retractor Pin and Clip
Hole Plugs
Cable Cubby 500 and 700 • Installation Guide (Continued)
2
23.3"
(592 mm)
26.9"
(683 mm)
21.7"
(550 mm)
11.8"
(300 mm)
8.8"
(224 mm)
30
30
Table Top
Retractor Series
9.0"
(229 mm)
15.2"
(386 mm)
21.2"
(538 mm)
Retractor Series XL
3.0"
(76 mm)
3.0"
(76 mm)
29.3"
(744 mm)
Retractor Series XL
Retractor Series
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
Ensure that the edge on which the lid opens is oriented correctly.
Ensure that there is ample space under the table for cables.
When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see dimensions for the Retractors below).
Choose a method for cutting the hole in the table
ATTENTION:
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to
prevent scarring or damaging the furniture.
L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et qualifiés.
Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
If using a CNC wood router or other
precise machinery, use the exact
cut-out dimensions for your model
(see the table below).
Visit www.extron.com for Cable Cubby routing
template part numbers and instructions.
Dimensions and cut-out templates are
available online at www.extron.com.
Cable
Cubby
Model
Cut-out Dimensions
User Access
Width
Side
Dimension
500 5.75" (14.6 cm) 5.75" (14.6 cm)
700 7.125" (18.1 cm) 5.75" (14.6 cm)
500 CCB 5.75” (14.6 cm) 7.125” (18.1 cm)
NOTES:
To prevent objects from impeding cable retraction, allow at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 6).
Cut-Out Template for the Extron
Cable Cubby 500
0.25"
(0.635 cm) R
User Access
5.75"
(14.60 cm)
5.75"
(14.60 cm)
0.25"
Trim Ring
Lip Width
2.0"
Trim Ring’s Outer Edge
(Do not cut this line.)
0.00” (0.00 cm)
0.02 (0.05 cm)
+
Table Clamp
P/N 68-8599-01 Rev. A
SURFACE
CUT-OUT
AREA
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 500
will be installed.
5. Double check dimensions and position,
then cut the opening.
Page Size: 11" x 17"
Print Scale 1:1
Do not Shrink
0.25"
(0.635 cm) R
5.75"
(14.60 cm)
5.75"
(14.60 cm)
SURFACE
CUT-OUT
AREA
Cut-Out Template for the Extron
Cable Cubby 500
User Access
0.25"
Trim Ring
Lip Width
2.0"
Trim Ring’s Outer Edge
(Do not cut this line.)
0.00” (0.00 cm)
0.02 (0.05 cm)
+
Table Clamp
P/N 68-8599-01 Rev. A
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 500
will be installed.
5. Double check dimensions and position,
then cut the opening.
Page Size: 11" x 17"
Print Scale 1:1
Do not Shrink
Jigsaw
Cut O
Cut-Out T
e
C
Cab
3
125V~ 50-60Hz 12A MAX TOTAL
TOP
125V~ 50-60Hz 12A MAX TOTAL
TOP
Insert the modules
into the
Cable Cubby.
Secure the modules using
the provided mounting
screws and star
washers (4) on the
front and back of the
enclosure.
1
2
AAP Module
Cable Pass-Through Module
Retractor Trim
Preparing the Cable Cubby
Step 1 — Assemble the connectivity modules of your choice.
Connectivity modules allow you to populate the Cable Cubby with a combination of AAPs, cable pass-throughs, or Retractors.
NOTE:
Use a screwdriver to secure the Retractor trim with the screws.
After installing the trim, proceed to “Step 2 — Install the modules”
to install the power module.
Retractors are installed after the Cable Cubby is mounted on the
table (see Installing Retractors on page 5).
NOTE: After assembling the module,
proceed to “Step 2 — Install the
modules.”
Secure the retractor trim
using the provided
mounting screws (2).
Step 2 — Install the modules
Determine where the connectivity modules and power module will be
installed in the Cable Cubby. The modules may be installed at various
heights.
NOTE:
Ensure that there is enough room above the modules for
the Cable Cubby lid to close completely.
Use a screwdriver to secure the modules with the screws.
WARNING: Risk of Electric Shock. To ensure proper electrical
grounding, use the provided #6-32 mounting screws with the
star washers.
AVERTISSEMENT: Risque de choc électrique. Afin d’assurer
une mise à la terre correcte, utilisez les fixations de mise à la
terre #6-32 et les rondelles en étoile fournies.
NOTE: After assembling the module, proceed to “Step 2 — Install the modules.”
Secure up to two
single-space AAPs
in the AAP plate.
#4-40 Nut
w/ Captive Washer Insert cables through the bottom
of the connectivity bracket.
Connect cables to the AAPs.
Secure the AAP plate on the
connectivity brackets, using
two of the provided module
screws.
Insert cables through the bottom
of the connectivity bracket and
into the holes of the grommet plate.
Secure the grommet plate on
the connectivity bracket using
two of the provided module
screws.
Snap the included hole plugs
into any unused holes.
1
2
3
1
2
3
2
Insert cables
through the
bottom of the
connectivity
bracket and into
the holes of the
grommet plate.
Secure the
grommet plate
on the connectivity
bracket using two
of the provided
module screws.
Snap the included
hole plugs into
any unused holes.
1
2
3
For Show Me Cables:
Insert Show Me
Cables into the
grommet plate.
1
Attach the Show Me
Cable Trim Plate to the
top of the module, using
the module screws.
2
Attach the grommet
plate to the bottom
of the module, using
the module screws.
3
4
Step 1 — Mount the Cable Cubby flush with the table.
Mounting the Cable Cubby in the Table
Connecting a Cable Cubby 500 CCB
For Cable Cubby 500 CCB models, follow the instructions below, then proceed to Mounting the Cable Cubby in the Table.
The Cable Cubby 500 CCB contains three contact closure buttons to control input selection on Extron switchers and products
with contact closure control ports. Wire the Cable Cubby switches to the control product as shown in the wiring diagram below.
To wire the captive screw connectors:
1. Strip away 3 inches of the outer jacket
from the end of the cable, and
3/16 inch (5 mm) of the inner jacket
from the end of each wire.
2. Secure the wires to the captive screw
connector using an Extron Tweeker
or other small screwdriver. Follow the
wiring diagram at the right.
CAUTION: The flanged edges of the top of the surface
enclosure are sharp. These edges are also soft and
may be easily nicked or bent. Exercise caution when
handling the enclosure to prevent personal injury or
damage to the enclosure.
ATTENTION: Les extrémités à brides du haut de la
surface du boîtier sont aiguisées. Ces extrémités
sont aussi lisses et peuvent facilement être coupées
ou pliées. Soyez prudents lorsque vous manipulez
le boîtier afin d’éviter de l’endommager ou de vous
blesser.
NOTE: See the table at right to
determine and select the appropriate
current-limiting resistor, if needed.
CGT+V
CNONC
Contact (C)
Ground (G)
Tally output (T)
Tally voltage (+V)
RESISTOR
Extron Switcher with
Contact Closure Input
and Tally Output
Lower the Cable Cubby into the hole to test the t.
If necessary, carefully enlarge the opening.
Remove the plastic strips
and lm on the surface of
the Cable Cubby.
Ensure that the
side clamps are
seated against
the enclosure.
1
2
3
Blue
1A @
24 VDC /
125 VAC
See
note
below
4.52 K,
1%
13 K,
1%
Momentary switch
(single pole, double throw)
on captive screw terminal
NOTE: No resistor required for 5 VDC source.
5
Cable Cubby 500 and 700 • Installation Guide (Continued)
Step 2 — Under the table, adjust the side clamps on the enclosure.
Installing Retractors
Follow the steps below to install Retractors. For horizontal or angular Retractor
mounting, see the information at right, then follow the steps below.
NOTE: To lower the side
clamp, turn the lever
down, then press and
hold the locking plate
while sliding down the
clamp.
Angular Mounting
Remove the enclosure screws as shown above, then follow
this step:
Horizontal Mounting
See the Cable Retractor Setup Guide, available on the
Extron website, for additional steps.
Remove two enclosure screws
(one on each side) from this position.
Then, mount the Retractors as shown
at left.
Cable Release
Assembly
Move the cable release assembly upward until
the angular mounting hole is visible. Reinstall the
enclosure screws in this hole (both sides).
Remove two enclosure screws
(one on each side) from this position.
Then, mount the Retractors as shown
at left.
Cable Release
Assembly
Move the cable release assembly upward until
the angular mounting hole is visible.
Reinstall the
enclosure screws in this hole (both sides).
1
Rotate the side clamp
outward and ensure that
the lever is down.
Slide the clamp all the way
up against the bottom of
the table.
Ensure the Cable Cubby
is rmly seated in the table.
Raise the lever to secure
the Cable Cubby.
Lever
12 3
Locking
plate
Secure the clip
on the pin.
Insert retractors into
the retractor trim.
Secure the locking screw on
each Retractor.
Insert the pin through the
retractor mounting hole on
the side of the Cable Cubby
and retractor assembly.
1
2
3
4
Do not overtighten. The locking
screw only needs to be snug.
68-3551-50 A
05 20
6
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2015-2020 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation.
Check all parts and equipment before installation.
Preparing the Table (page 2)
Determine the best location for the enclosure.
Choose a method for cutting the hole in the table.
Preparing the Cable Cubby (page 3)
Choose and assemble a combination of AAP, cable-pass through, and Retractor connectivity to populate the Cable Cubby.
Secure the connectivity modules and power module in the Cable Cubby.
Connecting a Cable Cubby 500 CCB (page 4)
Mounting the Cable Cubby in the Table (page 4)
Mount the Cable Cubby ush with the table.
Adjust the side clamps.
Installing Retractors (page 5)
Routing and Connecting Cables (page 6)
Routing and Connecting Cables
CAUTION:
Risk of Electric Shock.
This equipment must be grounded.
ATTENTION:
Risque de choc électrique.
Cet équipement doit être xé au sol.
NOTE: Ensure that there is no tension on the power cable.
Secure cables with zip ties to the rectangular
holes in the rear of the Cable Cubby.
For cable pass-through applications, allow at least 36 inches (0.9 m)
of cable loop for each cable.
Connect cables to the AV system
and connect the AC power cord.
2
1
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron Cable Cubby 500 Manuel utilisateur

Catégorie
Câbles de signal
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues