Date Issued: 10/13/17 IS-43950-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
6) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
7) Raisexture[4]toceiling,carefullypassingmountingscrews
throughholesincanopy.Becertainwiresdonotgetpinched
between canopy and ceiling.
8) Slip lockwashers[8]onmountingscrewsandthreadlockup
knobs[10]ontomountingscrews.Tightentosecurextureto
ceiling.
9) Slidethetrim[16] and the glass shade[12] above the glass
shade/socket holder.
10) Inserttheslottedmetalwasher[14]andtheslottedrubber
washer[13] into the slot above the socket.
11) Insertrecommendedbulb(notsupplied).
12) Slidetheglassshadebackdownwiththetrimontothein-
stalled washers.
NOTE:Heightofxturemustbeadjustedbeforextureismounted
to ceiling.
1) Toadjustthelengthofthecord[1] to achieve the desired height
ofthemountedxture:Loosenscrew[2] on strain relief[3] on
canopy[4]
.Carefullypullcordupintocanopytoshortenthe
heightofxtureorcarefullypullcorddowntolengthenthe
heightofxture.Whendesiredheightisachieved,tighten
screw.Repeatasrequired.
2) Takethebackplate[15]andmounttotheoutletbox[7]using
themountingscrews[11].
3) Use the two (2) dry wall anchors[8] one on each end of the
backplateandsecurewiththetwo(2)screws[5].
4) Connect safety cable[6]intotheoutletboxsecurely.
5) Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwitha
holeandtworaiseddimples.Wrapgroundwirefrom
outletboxaroundgreengroundscrew,andthreadinto
hole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnector.(Notpro-
vided.)Afterfollowingtheabovesteps.Neverconnectground
wiretoblackorwhitepowersupplywires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or Red
Supply Wire to:
Connect White Supply Wire to:
Blac
hite
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wire (SPT I & SPT II)
are used. The neutral wire is square shaped or
ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
13
12
9
10
4
11
1
2
3
6
5
8
7
14
15
16