10 Part Number: 000016341 Rev00 1/21
Installation Section 2
Shut off the incoming water supply.
NOTE: Please review the following recommendations before
installing the water lines.
• Tubing must be 3/8" O.D., (.371 - .376).
• Cut the tube square. The outside diameter must be free
of score marks.
• Burrs and sharp edges must be removed prior to
installation.
NOTE: Use a tube insert for thin-walled plastic tubing.
To install water lines into the inlet/outlet ports:
1. Insert water line tubing into the inlet port fitting.
Notice
The fitting will grip before it seals. Tubing must be pushed
into the tube stop to prevent leaks.
2. Pull on the tubing to be sure it is secure. If the tubing
releases, refer to the Troubleshooting section of this
manual to reinstall.
3. Repeat for the outlet port fitting. Connect outlet water
line to the potable water connection on the ice machine.
NOTE: For water-cooled machines, be sure that the filter
system only feeds the potable water connection.
Have the min.-max. water temperature and pressure
been checked? (Refer to “Installation” on page 7)
Has the filter system been installed away from heavy
traffic areas?
Is the system installed securely to the mounting surface?
Has the water supply line been checked for suitability?
(Refer to “Water Service”)
Have the water supply lines been securely installed
into the inlet/outlet ports? (Refer to “Installation - AR-
10000-P/AR-20000-P & AR-40000-P”)
1. Turn on the incoming water supply.
2. Check for leaks. If the connections are leaking, refer to
the Troubleshooting section of this manual to reinstall.
NOTE: System should be flushed for 10 minutes to remove
trapped air and carbon fines.
NOTE: The filter pressure will decrease as the cartridge life
decreases.
AR-Pre-P, AR-10000-P, AR-20000-P and AR-40000-P systems are certified by IAPMO R&T against CSA B483.1; NSF/ANSI 372 for
Low Lead Content; NSF/ANSI 42 and/or *NSF/ANSI 53 for the reduction of claims listed in the Performance Data Sheet.
*NSF/ANSI 53 Cyst reduction claims are valid only when system flow is restricted at or below the specified range and/or
as specified in the ice machine capacity ranges on page 5. System flow rates should be verified after installation to ensure
filterable cyst reduction per the above.
Please see ice machine manufacturer’s technical publications for internal flow controller maximum operating flow rate
specifications.
Model Flow Rate
AR-10000-P At or below 0.75 gpm (2.84 lpm)
AR-20000-P At or below 1.25 gpm (5.68 lpm)
AR-40000-P At or below 2.0 gpm (7.57 lpm)