Ingersoll-Rand ENL 6 HP Instructions For Installation And Operation Manual

Taper
Instructions For Installation And Operation Manual

Ce manuel convient également à

Instructions for installation and operation english
Instruciones de instalación y de servicio español
Instructions de montage et de service français
Instruções de instalação e de serviço português
ENL 6 HP
More Than Air. Answers.
Online answers: http://www.ingersollrandproducts.com
C.C.N.: 80442916
REV.: C
DATE: DECEMBER 2013
2
ENL 6 HP
http://www.ingersollrandproducts.com
Safety instructions
Please check whether or not these instructions correspond to the device type!
Please adhere to all advice given in these operating instructions. They include basic information which needs to be
observed during installation, operation and maintenance. Therefore, it is vital for the technician and the responsible
operator /skilled personnel to read these operating instructions prior to installation, start-up and maintenance. The
operating instructions must be accessible at all times at the place of application of the ENL 6 HP.
In addition to these operating instructions, local and national regulations need to be observed, if required.
Make sure that the ENL 6 HP. is operated only within the permissible limit values indicated on the type plate. Any devia-
tion involves a risk for persons and materials, and may result in malfunction and service failures.
If you have any queries regarding these installation and operating instructions, please contact Ingersoll Rand
.
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• Thefeedpipemustbetubedrmly.Dischargepipe:short,xedpressurehoseontopressure-resistantpipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact with non-insulated
components carrying supply voltage.
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• Service measures must only be undertaken when the system is deactivated!
• Alltypesofelectricalworkmustbecarriedoutbyauthorisedandqualiedpersonnelonly.
Further safety advice:
• For installation and operation, the national regulations and safety codes in force must also be adhered to.
• Do not use the ENL 6 HP in hazardous areas.
Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular to conical screw
joints.
• The ENL 6 HP will only function when voltage is applied.
• Do not use the test button for permanent drainage!
• Only use genuine spare parts! This is imperative to ensure perfect functioning.
Additional advice:
• Duringinstallation,usethespanneratatthefeedpipe(widthacrossat36)asabackrest.
3
ENL 6 HP http://www.ingersollrandproducts.com
Caution!
Malfunctions in the application!
Throughincorrectinstallationandinsufcientmaintenance,theENLcanmalfunction.Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
Fail-safe condensate discharge directly optimises the compressed-air quality.
To prevent damage and failures, it is imperative
To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with
the case of application (see chapter "Proper use").
To strictly adhere to the installation and operating advice in these instructions.
To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.
Proper use
The ENL is an electronically level-controlled condensate drain for compressed-air plants.
It is employed within the permissible operating parameters (see "Technical data").
The ENL is able to drain condensate under operating pressure from the plant components virtually without compressed-air
losses.
For its function, the ENL 6 HP requires an operating voltage and an operating pressure (see "Technical data").
As far as the employment in plants with increased demands on the compressed-air quality is concerned (food industry, medi-
cal technology, laboratory equipment, special processes etc.), the operator must decide on measures for the monitoring of
the compressed-air quality. These have an effect on the safety of the subsequent processes and may prevent damage to
persons and plants.
It is the task of the operator to ensure that the indicated conditions are met during the entire operating time.
For the employment in CO
2
plants,aENLwithaCOspecication(ENL...CO)mustbeused.
The ENL and the condensate supply line need to be protected against frost, as otherwise the function cannot be guaranteed.
Ingersoll Rand also offers suitable products for this purpose.
Exclusion from the eld of application
The ENL as a condensate drain alone cannotguaranteeadenedcompressed-airquality,forthispurpose,otheradditional
technical devices are required.
ENL 6 HP is not suitable for use in plants carrying vacuum or atmospheric ambient pressure or in hazardous areas.
The ENL must not be exposed to permanent direct solar or thermal radiation.
ENL 6 HP must not be installed and operated in areas with an aggressive atmosphere.
4
ENL 6 HP
http://www.ingersollrandproducts.com
Indicaciones de seguridad
Porfavor,compruebequeestemanualdeinstruccionescorresponderealmenteasumáquina.
Tenga en cuenta todas las indicaciones facilitadas en este manual. Contiene información básica importante para la
instalación, el funcionamiento y el mantenimiento de la máquina. Por este motivo es imprescindible que tanto el técni-
co de instalación como los operarios y personal responsable lo lean antes de realizar trabajos de instalación, puesta
en marcha y mantenimiento.
El manual de instrucciones deberá estar disponible en todo momento en el lugar de instalación del ENL 6 HP.
Además de las indicaciones contenidas en el manual, deberán respetarse las normativas vigentes locales y naciona-
les que correspondan.
Asegúrese de que el ENL 6 HP solamente se pone en marcha dentro de los valores límite admisibles, indicados en
laplacaidenticativa.Deotramanera,podríanocasionarsedañosapersonasyobjetos,asícomoaverías.
Sitienealgunadicultadparaentenderelcontenidodelmanualoquierehaceralgunaconsulta,lerogamosquese
ponga en contacto con Ingersoll Rand.
Peligro!
¡Aire comprimido!
Ungolpedeairecomprimidoqueescaparepentinamenteoporcomponentesdelamáquinaquesalgan
disparados por su efecto puede suponer peligro de graves lesiones o muerte.
Medidas preventivas:
•Nosobrepasarlapresiónmáx.defuncionamiento(verplacaidenticativa)
Realicelostrabajosdemantenimientosiempreconlamáquinadespresurizada.
• Utilice solamente materiales resistentes a la presión para la instalación.
•Apretarbienlaconduccióndealimentación.Conduccióndesalida:mangueradepresióncortajadaaunatuberíaresistente
a la presión.
• Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido.
¡Peligro!
¡Corriente eléctrica!
Elcontactoconcomponentessometidosatensiónysinaislamientoacarreapeligrodesufrirdescargas
eléctricas que deriven en heridas o muerte.
Medidas preventivas:
• Al realizar la instalación eléctrica, respete todas las normativas vigentes (por ejemplo, la VDE 0100 / IEC 60364).
• Realice siempre los trabajos de mantenimiento con la máquina desconectada de la red eléctrica.
•Lostrabajoseléctricosdeberándejarseenmanosdepersonalautorizadoycualicado.
Otras indicaciones de seguridad:
• Durante la instalación y el funcionamiento deberán respetarse igualmente las normativas nacionales de seguridad vigentes.
• No utilizar el ENL 6 HP en zonas con peligro de explosión.
Evite los momentos de apriete excesivos al atornillar las conducciones de alimentación. Esto deberá tenerse en cuenta es-
pecialmente en el caso de atornilladuras cónicas.
• El ENL 6 HP sólo podrá funcionar con corriente.
• No utilizar la tecla de test para la evacuación continua de agua.
• Utilice exclusivamente recambios originales. Sólo así quedará garantizado el buen funcionamiento del aparato.
Indicaciones adicionales:
• Para el montaje de la alimentación use llaves (SW36) para sujetar.
5
ENL 6 HP http://www.ingersollrandproducts.com
¡Precaución!
¡Mal funcionamiento!
UnainstalaciónincorrectaylafaltademantenimientopuedenprovocarqueelENLfuncionemal.
Elcondensadonoevacuadopuedeprovocardañosenlasinstalacionesyenlosprocesosdeproducción.
Medidas preventivas:
Una evacuación segura del condensado optimiza la calidad del aire comprimido de manera directa.
•Tengaencuentalospuntossiguientesparaprevenirdañosyparadasenlaproducción:
• Respeto del uso apropiado y de los parámetros de servicio del ENL teniendo en cuenta el campo de aplicación de cada
caso (véase capítulo “Uso apropiado”)
• Observación estricta de las indicaciones de instalación y servicio facilitadas en este manual.
• Mantenimiento regular y control del ENL acorde a las indicaciones del manual.
Uso apropiado
• El ENL es un purgador de condensados regulado electrónicamente según el nivel para instalaciones de aire comprimido.
• Su funcionamiento deberá producirse siempre teniendo en cuenta los parámetros de servicio (ver datos técnicos).
• El ENL es capaz de evacuar el condensado bajo presión de servicio y sin producir apenas pérdidas de presión.
• El ENL 6 HP necesita para su funcionamiento una corriente y una presión concretas (ver datos técnicos).
En aquellas aplicaciones en las que se exige un nivel de calidad de aire comprimido más alto (industria de la alimentación,
técnica médica, laboratorios, procesos especiales, etc.), el usuario deberá tomar medidas para la vigilancia de dicha calidad.
Esasmedidasinuyenenlaseguridaddelosprocesossucesivosypuedenevitardañosapersonaseinstalaciones.
• Será responsabilidad del usuario garantizar que se cumplan estas condiciones durante todo el tiempo de funcionamiento.
• En instalaciones de CO
2
deberáninstalarseunidadesENLconlaespecicaciónCO(ENL..CO).
El ENL y su conducción de alimentación deberán estar protegidos contra congelación, ya que de lo contrario no podrá ga-
rantizarse su buen funcionamiento.
IngersollRandleofreceproductosadecuadosparaesten.
Campos de aplicación incorrectos
• El ENL no puede garantizar por sí solo como purgador de condensados una calidad de aire comprimido concreta. Para ello
serán necesarios otros equipos técnicos.
• El ENL 6 HP i no es adecuado para su aplicación en el campo del vacío ni en plantas que funcionen a presión atmosférica
ni en zonas Ex.
• El ENL no deberá exponerse a la radiación solar continua ni directa, ni tampoco a la acción de fuentes de calor.
• El ENL 6 HP no debe instalarse ni funcionar en zonas con atmósferas agresivas.
6
ENL 6 HP
http://www.ingersollrandproducts.com
Consignes de sécurité
Vériezquecettenoticecorrespondebienaumodèled'appareilenvotrepossession.
Respectez toutes les consignes données dans ce mode d'emploi. Il contient des informations fondamentales, à res-
pecter lors de l'installation, de l'utilisation et de la maintenance. C'est pourquoi, il est impératif que ce mode d'emploi
soit lu avant l'installation, la mise en service et la maintenance, par l'installateur ainsi que par l'exploitant et le person-
nelqualié.
Le mode d'emploi doit être disponible et accessible à tout moment sur le lieu d'utilisation du ENL 6 HP .
En plus de ce mode d'emploi, il faut respecter les éventuelles prescriptions locales ou nationales.
Assurez-vous que le ENL 6 HP . ne soit utilisé qu'au sein des valeurs limites admissibles et mentionnées sur la plaque
signalétique. Dans le cas contraire, il peut présenter un risque pour les personnes et le matériel, voire nuire au bon
fonctionnement de l'installation ou générer des perturbations.
Si certains points ne sont pas clairs ou si vous avez des questions au sujet de ces instructions de montage et de ser-
vice, n'hésitez pas à contacter la société Ingersoll Rand.
Danger !
Air comprimé !
Toutcontactavecdel'aircomprimés'échappantrapidementoudefaçonbrutaleoutoutcontactavecdes
partiesdel'installationprésentantunrisqued'éclatementpeutcauserdegravesblessuresouentraînerlamort
.
Mesures préventives :
Ne pas dépasser la pression de service maximale (voir plaque signalétique).
Dépressuriserlepurgeuravanttouteinterventiond'entretienoudemaintenance.
N'utiliser que du matériel d'installation résistant à la pression.
•Laconduited'amenéedoittoujoursêtreréaliséeentuyauterierigideetxe.Conduited'évacuation:exibledefaiblelon-
gueur,xéetreliéàunetuyauterie,tousdeuxrésistantàlapression.
Veillez à ce qu'aucune personne ni objet ne risque d'être touché par le condensat ou l'air comprimé qui s'échappe.
Danger !
Tension électrique !
Tout contact avec des éléments non isolés et sous tension présente un risque de choc électrique pouvant
provoquerdesblessuresouentraînerlamort.
Mesures préventives :
Lors de la réalisation de l'installation électrique, respecter toutes les prescriptions en vigueur (p. ex. VDE 0100 / IEC 60364).
• Avant toute intervention d'entretien ou de maintenance, mettre le purgeur HORS TENSION.
• Touteinterventionélectriquedoitêtreréaliséeexclusivementparunpersonnelqualiéethabilité.
Autres consignes de sécurité :
• Lors de l'installation et de l'utilisation, il faut également respecter les directives et consignes de sécurité en vigueur dans le
pays en question.
• Ne pas utiliser le ENL 6 HP dans les atmosphères explosibles.
• Éviter les serrages trop importants au niveau des raccords de la conduite d'amenée Ceci est valable en particulier pour les
raccordsàletageconique.
• Le ENL 6 HP n'est opérationnel que s'il est sous tension (alimentation électrique assurée).
• Ne pas utiliser le bouton Test pour l'évacuation permanente du condensat.
• Utiliser exclusivement des pièces de rechange d'origine. Seul le respect scrupuleux des consignes données peut garantir le
parfait fonctionnement de l'appareil.
Consignes supplémentaires :
• Lors du montage, utiliser le méplat pour clé au niveau de l'arrivée (36 mm) pour maintenir le purgeur pendant le serrage.
7
ENL 6 HP http://www.ingersollrandproducts.com
Prudence !
Dysfonctionnementsauniveaudel'utilisation!
Encasd'installationincorrecteetdemaintenanceinsufsante,desdysfonctionnementspeuventapparaître
auniveauduENL.
Toutcondensatnonévacuérisqued'endommagerlesinstallationsetdeporteratteinteauxprocessusde
fabrication.
Mesures préventives :
Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualité de l'air comprimé.
Pour éviter tout endommagement et tout arrêt de production, il est impératif de respecter les consignes suivantes :
Respecter scrupuleusement les instructions pour une utilisation conforme à l’usage prévu et les paramètres de
fonctionnement du ENL dans le contexte de son utilisation (consulter à cet effet le chapitre „Utilisation
conforme à l’usage prévu“).
Respecter scrupuleusement toutes les instructions d'installation et d'utilisation communiquées dans cette notice.
Respecter scrupuleusement la périodicité de maintenance et de contrôle du ENL selon les indications de ce
manuel d'utilisation.
Utilisation conforme à l'emploi prév
Le ENL est un purgeur de condensat à régulation électronique de niveau pour les installations de production et distribution
d'air comprimé.
L'utilisation s'effectue dans le respect des paramètres de fonctionnement admissibles (voir caractéristiques techniques).
Le ENL permet d'évacuer le condensat du réseau de distribution sous pression (pression de service) et ce, pratiquement
sans perte de charge.
Pour son fonctionnement, le ENL requiert une tension d'alimentation électrique et une pression de service (voir caractéris-
tiques techniques).
Lors d'une utilisation dans des installations soumises à des exigences plus poussées quant à la qualité de l'air comprimé
(industrie alimentaire, techniques médicales, équipements de laboratoires, processus spéciaux, etc.), l'exploitant est tenu
deprendredesmesurespourlasurveillancedelaqualitédel'aircomprimé.Cesmesuresontuneinuencedirectesurla
sécurité des processus en aval et permettent ainsi d'éviter les dommages corporels et l'endommagement des installations.
Il incombe à l'exploitant d'assurer les conditions mentionnées pendant toute la durée de service.
Pour les installations de CO
2
, il faut impérativement utiliser un ENL en version CO (ENL .. CO).
Le ENL et la conduite d'amenée du condensat doivent être protégés contre le gel, sinon le fonctionnement n'est pas assuré.
Ingersoll Rand propose également des produits adéquats à cet effet.
Exclusion du domaine d'application
• Entantquepurgeurdecondensat,leENLnepeutpasgarantiràluiseulunequalitéd'aircomprimédénie;pourcefaire,il
faut d'autres équipements techniques en plus.
• Le ENL 6 HP ne convient pas pour l'utilisation sur des installations sous vide ou fonctionnant à la pression atmosphérique
ambiante, ni pour l'utilisation dans les atmosphères explosibles.
Le ENL ne doit pas être exposé en permanence au rayonnement direct du soleil ou à un rayonnement thermique.
• Le ENL 6 HP ne doit pas être installé ni utilisé dans les domaines exposés à une atmosphère agressive.
8
ENL 6 HP
http://www.ingersollrandproducts.com
Indicações de segurança
Favorvericarseaspresentesinstruçõescorrespondemaotipodeaparelho.
Observar todas as advertências contidas nas presentes instruções de serviço. As instruções contêm indicações bá-
sicas que deverão ser observadas durante a montagem, a operação e a manutenção. Por esses motivos, antes da
instalação, da colocação em serviço e dos trabalhos de manutenção estas instruções deverão ser lidas, sem falta,
pelo técnico de montagem, pelo cliente e pelo pessoal técnico.
As instruções deverão estar sempre disponíveis junto do local de utilização do ENL 6 HP.
Adicionalmente a estas instruções também deverão ser observadas as diretivas locais e/ou nacionais.
Ter a certeza que o ENL 6 HP só irá funcionar no âmbitos dos valores limite indicados na placa de características. Do
contrário existe perigo para pessoas e materiais, podendo ocorrer falhas de funcionamento e operacionais.
No caso de dúvidas ou de questões relacionadas com as presentes instruções de instalação e operação, favor entrar
em contato com a Ingersoll Rand.
Perigo!
Ar comprimido!
Ocontatocomarcomprimidoescapandorápidaourepentinamenteoupeçasquerebentame/ouquenão
estãoxadaspodemprovocarferimentosgravesouamort
Medidas a serem tomadas:
• Não ultrapassar a pressão máxima de serviço (ver placa de características).
Trabalhosdemanutençãosédevemserexecutadoscomosistemadespressurizado.
• Só usar material de instalação à prova de pressão.
•Montardemodoxoatubulaçãodeadmissão.Tubulaçãodedescarga:mangueiradepressãocurtaeligadaaumtuboà
prova de pressão.
• Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa.
Perigo!
Tensãodarede!
Devidoaocontatocompeçasnãoisoladasecondutorasdatensãoderedeexisteoperigodechoque
elétrico com ferimentos e morte.
Medidas a serem tomadas:
• Na instalação elétrica deverão ser observadas todas as diretiva vigentes(p. ex. VDE 0100 / IEC 60364).
• Trabalhos de manutenção só devem ser executados com o sistema desenergizado.
• Todos os trabalhos elétricos só poderão ser efetuados por pessoal especializado e autorizado.
Outrasindicaçõesdesegurança:
• Durante a instalação e a operação também devem ser observadas as diretivas e as instruções de segurança nacionais.
• Não utilizar o ENL 6 HP em áreas com perigo de explosão.
Nas uniões roscadas de alimentação evitar forças de aperto excessivas. Isso aplica-se, especialmente, a uniões roscadas
cônicas.
• O ENL 6 HP só está operacional se tiver tensão aplicada.
• O botão de teste não deverá ser utilizado para a drenagem permanente.
•Utilizarexclusivamentepeçasdereposiçãooriginais.Sóassimcarágarantidoumfuncionamentoperfeito.
Indicaçõesadicionais:
• Durante a montagem utilizar as superfícies das chaves na parte de alimentação (tamanho SW36) para segurar.
9
ENL 6 HP http://www.ingersollrandproducts.com
Cuidado !
Maufuncionamentonaaplicação!
Devidoaumainstalaçãoincorretaeaumamanutençãoinsucienteépossívelqueocorraomaufunciona
mentodoENL.Ocondensadonãoevacuadopoderácausardanosemequipamentoseemprocessosdefa-
bricação.
Medidas a serem tomadas:
Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido.
Para evitar danos e falhas, favor observar sem falta:
• ObservaçãoprecisadautilizaçãodeacordocomanalidadeedosparâmetrosoperacionaisdoENLemligaçãocomo
casodeutilização(veraesterespeitoocapítulo„Utilizaçãodeacordocomanalidade“)
• Observação precisa das indicações sobre instalação e operação contidas nas presentes instruções
• Manutenção regular e controle do ENL segundo as indicações contidas nas presentes instruções
Utilização de acordo com a nalidade
O ENL é um condutor de descarga de condensado com regulação eletrônica de nível e destinado a equipamentos de ar
comprimido.
• A utilização é feita no âmbito dos parâmetros operacionais admissíveis (ver Dados Técnicos).
O ENL pode descarregar condensado das partes do equipamento, sob pressão de serviço e praticamente sem perda de ar
comprimido.
• Para funcionar, o ENL 6 HP precisa de uma tensão de serviço e de uma pressão de serviço (ver Dados Técnicos).
No caso de utilização em equipamentos com elevadas exigências à qualidade do ar comprimido (indústria alimentícia, ele-
tromedicina, equipamentos de laboratório, processos especiais etc.), a entidade exploradora terá que decidir sobre medidas
relativasàmonitoraçãodaqualidadedoarcomprimido.Taismedidasexerceminuênciasobreasegurançadosprocessos
seguintes, podendo evitar danos em pessoas e equipamentos.
• Cabe à entidade exploradora garantir as citadas condições durante todo o período de funcionamento.
•ParaoempregoemequipamentosCO2,énecessárioutilizarumENLcomaespecicaçãoCO(ENL..CO).
•OENLeatubulaçãocondutoradecondensadodeverãoserprotegidoscontraageada,docontrárionãocaasseguradaa
funcionalidade.
ParaessanalidadeaIngersollRandofereceprodutosadequados.
Exclusão do campo de aplicação
• OENLcomocondutordedescargadecondensadonãopodeporsisógarantirumaqualidadedenidadearcomprimido,
pois para isso são ainda necessários outros dispositivos técnicos.
• O ENL 6 HP não é apropriado para utilização com vácuo ou em equipamentos conduzindo pressão atmosférica ambiente ou
em áreas com perigo de explosão.
• O ENL não pode estar exposto permanente à incidência direta dos raios solares ou do calor.
• O ENL 6 HP não pode ser instalado nem funcionar em áreas com uma atmosfera agressiva.
10
ENL 6 HP
http://www.ingersollrandproducts.com
Technische Daten • Datos técnicos
Caractéristiques • Dados técnicos
Max. performance for the blue climatic zone – see also Chapter "Climatic zone and performance data".
Capacidad máx. para zona climática azul – ver también capítulo “Zonas climáticas y datos de capacidad"
Capacité max. pour la zone climatique Bleu – voir aussi chapitre „Zones climatiques et Capacités“
Potência máxima para zona climática azul – ver também o capítulo "Zona climática e dados de potência"
ENL 6
Operating pressure, min/max
Presión de servicio mín./máx.
Pression de service min/max
Pressão de serviço mín./máx.
18 ... 913 psi
(1,2 ... 63 bar)
min./max. temperature
Temperatura mín./máx.
Température min./max.
Temperatura mín./máx.
+34 ... +140 °F
(+1 ... +60 °C)
Condensate feed
Entrada condensado
Entrée du condensat
Alimentação de condensado
½ NPT / G ½
Condensate discharge (hose)
Salida de condensado (manguera)
Sortieducondensat(exible)
Descarga do condensado (mangueira)
⅜"
Condensate
Condensado
Condensat
Condensado
oil-contaminated + oil-free
con aceite + sin aceite
Aluminiosupercialmente
contendo óleo + isento de óleo
Housing
Carcasa
Corps
Gabinete
Aluminum, hard-coated
aluminio, con recubrimiento
Aluminum, avec protection anticorrosive
Alumínio hard coated
Weight (empty)
Peso (vacío)
Poids (à vide)
Peso (vazio)
2.0 lbs
(1 kg)
peak compressor performance
Caudal máx. del compresor
Capacité maximale du compresseur
Potência máx. do compressor
280 scfm
7,9 m³/min
Peak refrigeration dryer performance (only with pre-separation)
Capacidadmáx.delsecadorfrigoríco(conpreseparación)
Capacité maximale du sécheur frigo (seules avec pré-separation)
Potência máxima do secador a frio (só com pré-precipitação)
560 scfm
15,8 m³/min
Peaklterperformance(behinddryer)
Capacidadmáx.deltración(detrásdelsecador)
Capacitémaximaledultre(enavaldusécheur)
Potênciamáximadoltro(apósosecador)
2800 scfm
79 m³/min
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1, second edition,
including Amendment 1, or a later version of the same standard incorporation the same level of
testing requirements.
Este producto se ha sometido a pruebas acorde a las exigencias de la CAN/CSA-C22.2 n.º 61010-1,
segunda edición, incluyendo el suplemento 1 o una versión posterior de la misma norma, conservando
siempre el mismo nivel de exigencia con respecto a las pruebas.
Ce produit a été testé selon les exigences de la norme CAN/CSA-C22.2 n° 61010-1, deuxième édition,
en tenant compte du complément 1 ou d'une version plus récente de la même norme, en appliquant le
même niveau d'exigences en matière de tests.
Este produto foi testado de acordo com os requisitos da CAN/CSA-C22 n° 61010-1, segunda edição,
com incorporação do aditamento 1 ou de uma versão posterior da mesma norma, levando em consi-
deração o mesmo nível de requisitos de teste.
11
ENL 6 HP http://www.ingersollrandproducts.com
Supply voltage
Tensión de funcionamiento
Tension d'alimentation
Tensão operacional
230 / 115 / ... / 24 VAC ± 10%, 50 ... 60 Hz / 24 VDC ± 10%
seetypeplate/verplacaidenticativa
voir plaque signalétique / vide placa de características
Power consumption
Potencia consumida
Consommation
Consumo de potência
P < 8,0 VA (W)
Fuse protection
Fusible
Fusibles
Fusível
recommanded AC: 1 A slow / stipulated DC: 1 A slow
recomend. para AC: 1 A lento / obligatorio para DC: 1 A lento
recomm. AC : 1 A fusion lente / prescrit DC : 1 A fusion lente
recom. para AC: 1 A lenta / prescrito para DC: 1 A lenta
Recommanded cable jacket diameter
Sección recomendada de la cubierta del cable
Diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro do cabo
0.23" ... 0.34"
(ø 5,8 ... 8,5 mm)
recommended wire cross-section
Sección recomendada del conductor
Section recommandée pour les conducteurs
Seção recomendada do condutor
0.03 ... 0.06 inches squared
(3 x 0,75 ... 1,5 mm²)
recommended stripping of cable jacket
Retirada recomendada de la cubierta del cable
Longueur recommandée pour le dénudage de la gaine du câble
Assentamento recomendado do invólucro do cabo
PE: ca. 2.3 inch L/N: ca. 1.96 inch
(PE: ca. 60 mm L/N: ca. 50 mm)
recommended wire stripping
Longitud recomendada de la virola del cable
Longueur recommandée pour le dénudage
Comprimento recomendado do invólucro do condutor
~ 0.24 inch
(~ 6 mm)
Connection data of the potential-free contact
Switch to load *)
Datos de conexión del contacto libre de potencial
Conmutación carga *)
Caractéristiques de raccordement du contact sans potentiel
Commuter une charge *)
Dados de conexão do contato livre de potencial
conectar carga *)
AC: max. 250 V / 1 A
DC: max. 30 V / 1 A
Connection data of the potential-free contact
Switch to low signal *)
Datos de conexión del contacto libre de potencial
Conmutaciónseñaldébil*)
Caractéristiques de raccordement du contact sans potentiel
Commuter un petit signal *)
Dados de conexão do contato livre de potencial
conectar sinal pequeno *)
min. 5 VDC / 10 mA
Protection class
Tipo de protección
Degré de protection
Classe de proteção
IP 65
Electrical data • Datos eléctricos
Caractéristiques electrique • Dados eléctricos
VAC = V alternating current / VDC = V direct current
*)
The switching of loads has the result that the properties of the contact are no longer suitable for the switching of low signals
.
VAC = V alternating current (corriente alterna) / VDC = V direct current (corriente continua)
*) La conmutación de cargas tiene como consecuencia que las características del contacto ya no sean las adecuadas para
laconmutacióndeseñalesdébiles.
VAC = V alternating current (Tension alternative) / VDC = V direct current (Tension continue)
*) La commutation de charges a pour conséquence que les propriétés du contact ne conviennent plus pour la commutation
de petits signaux.
VAC = V alternating current (tensão alternada) / VDC = V direct current (tensão contínua)
*) a conexão de cargas faz com que as características do contato deixem de ser apropriadas para a conexão de sinais
pequenos.
12
ENL 6 HP
http://www.ingersollrandproducts.com
Function • Funcionamiento
Functionnement • Funcionamento
1
4
2 3
6
5
Alarm signal via potential-free contact
Mensaje de alarma a través de contacto sin potencial
Signal d'alarme délivré sur le contact sans potentiel
Sinal de alarme via contacto isento de potencial
Switching sequence of valve in alarm mode
Secuencia de actuación de la válvula en el modo de alarma
Séquence d'activation de la vanne en mode Alarme
Sequência de ligação da válvula no modo de alarme
Thecondensateowsthroughthefeed
line (1) into the ENL unit and accumulates
in the container (2). A capacitive sensor
(3) continuously registers the liquid level
and passes a signal to the electronic
controlassoonasthecontainerislled.
The pilot valve (4) is then activated and
the diaphragm (5) opens the outlet line
(6) for discharging the condensate.
When the ENL unit has been emptied,
the outlet line is closed again quickly and
tightly without wasting compressed air.
When the microcontroller registers a
malfunction, the device will automatically
change to the alarm mode. The switching
sequence of the valve (see illustration)
continues until the fault is cleared (auto-
matically or through maintenance). The
red LED ashes as long as the device
is in the alarm mode.
Malfunctioning could be caused by, e.g.:
Mistakes during installation
Dropping below the necessary mini-
mum pressure
Excessive condensate quantities (over-
loading)
Blocked/shut off outlet line
Extreme amount of dirt particles
Frozen piping
Ifthefaultisnotclearedwithintherst
minute, a fault signal is triggered (see
illustration) which can be picked off as a
potential-free signal via the alarm relay.
english
Ready for operation
Voltage is being applied
Discharge procedure
Outlet line is open
Malfunction
Alarm mode is activated
Test
Manual drainage/alarm
The test button is used for checking
correct functioning.
Pressing Effect
Short Manual drainage
> 1 min Alarm mode
1
1
2
2
3
3
4
4
13
ENL 6 HP http://www.ingersollrandproducts.com
français
Amené dans le ENL par la conduite d'arri-
vée (1), le condensat est collecté dans
le réservoir (2). Une sonde capacitive
(3) surveille en permanence le niveau
de remplissage et envoie un signal à la
commande électronique dès que le réser-
voir est rempli. L'électrovanne pilote (4)
est activée et la membrane (5) ouvre la
conduite d'évacuation (6) pour l'éclusage
du condensat.
Dès que le ENL est vide, la conduite
d'évacuation est à nouveau refermée
avec une parfaite étanchéité, avant même
que l'air comprimé ne puisse s'échapper.
Lorsque le microcontrôleur détecte une
anomalie, il active le mode alarme. La
séquence d'activation de la vanne (voir
gure)persistejusqu'àcequeleproblème
soit résolu (automatiquement ou par inter-
vention de maintenance). La LED rouge
clignote pendant la fonction d'alarme.
Causes de dysfonctionnement
possibles:
Défaut au niveau de l'installation
Pression minimale non atteinte
Trop de condensat (surcharge)
Ecoulement bouché ou obturé
Importantes quantités d'impuretés
Conduites gelées
Si la panne n'est pas résolue en l'espace
d'une minute, un signal d'alarme est émis
(voirgure).Unsignalsanspotentielest
délivré par le relais d'alarme.
O condensado corre através do tubo adu-
tor (1) para dentro do ENL e acumulase
no interior da caixa (2). Um sensor que
trabalha capacitivamente (3) vai continu-
amente registando o nível, transmitindo
um sinal ao comando electrónico logo
que o depósito se encher de conden-
sado. A válvula de comando piloto (4) é
accionada e o diafragma (5) abre o tubo
de descarga (6) para escoamento do
condensado.
Esvaziado o ENL, o tubo de descarga
é de novo fechado hermeticamente a
tempo para evitar perdas desnecessárias
de ar comprimido.
Quandoomicrocontroladorvericauma
avaria, o alarme é activado. A sequên-
cia de ligação da válvula (ver imagem)
permanece activada até se eliminar a
avaria (automaticamente ou através de
manutenção). O LED vermelho pisca
durante a função de alarme.
Causas possíveis da avaria são p. ex.:
erro na instalação
pressão inferior à pressão mínima
admissível
quantidade excessiva de condensado
(sobrecarga)
tubo adutor entupido/passagem impe-
dida
quantidade excessiva de partículas de
sujidade
tubagens geladas
Se a falha não for eliminada durante o
primeiro minuto, o aparelho activa o sinal
de alarme (ver imagem), que poderá ser
comutado em sinal isento de potencial
através do relé do sinal.
português
Elcondensadouyeatravésdelatube-
ría de entrada (1) al ENL y se acumula
en el depósito (2). El sensor capacitivo
de nivel (3) controla permanentemente el
nivel de llenado. Si el depósito está lleno,
el sensor emite una señal a la unidad
de pilotaje electrónico. Inmediatamente
se acciona la válvula de pilotaje (4) y la
membrana (5) abre la salida (6) para
purgar el condensado.
En el momento en el que el ENL esta
vacío se cierra la salida herméticamente
antes de que se produzca un escape de
aire comprimido.
Si el microcontrolador detecta una
perturbación en el funcionamiento, se
activa el modo de alarma. La secuencia
de actuación de la válvula dura hasta
que la causa de la perturbación haya
sido eliminada(por si misma o por un
mantenimiento). El LED rojo parpadea
durante el estado de alarma.
Posibles causas son p.ej.:
fallos en el montaje
la presión está por debajo de la presión
mínima indicada
la cantidad de condensado es dema-
siado alta
está taponada o cerrada la tubería de
la salida
cantidad extrema de partículas de
suciedad
tuberías heladas
Si la perturbación no está eliminada
dentro del primer minuto, se activa el
mensaje de la alarma (ver imágen),
que puede ser transmitida como señal
sin potencial a través del relé de alarma.
español
En funcionamiento El aparato
está bajo tensión eléctrica
Procesode purga
La salida está abierta
Perturbación
El modo „ALARMA“ está ectivado
Test
Purga manual/alarma
El interruptor de „TEST“ sirve para
el control del funcionamiento.
Prêt à fonctionner
Tension d'alimentation présente
Phase de purge
Conduite d'évacuation ouverte
Dysfonctionnement
Mode Alarme activé
Test
Purge manuelle/Alarme
La touche Test sert à tester le
fonctionnement.
Estado de prontidão para entrar
em funcionamento Tensão aplicada
Processo de descarga
Tubo de descarga está aberto
Avaria
Modo de alarme está activado
Teste
Drenagem manual/alarme
O botão de teste é utilizado para
controlar o funcionamento.
Accionamiento Resultado
rápido purga manual
> 1 min modo de alarma
Action Effet
brève Purge manuelle
> 1 min Mode Alarme
Accionamento Efeito
rápido drenagem manual
> 1 min modo de alarme
1 1 1
2 2 2
3 3 3
4 4 4
14
ENL 6 HP
http://www.ingersollrandproducts.com
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• Thefeedpipemustbetubedrmly.Dischargepipe:short,xedpressurehoseontopressure-resistantpipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Caution!
Malfunctions in the application!
Throughincorrectinstallationandinsufcientmaintenance,theENLcanmalfunction.Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
Fail-safe condensate discharge directly optimises the compressed-air quality.
To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with the
case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.
Note:
It is imperative to observe all hazard statements and warnings listed here.
Pleasealsoobserve all regulations and notesregardingtheindustrialsafety and re prevention attherespectiveplaceof
installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact should be avoided.
Condensate is subject to mandatory waste disposal and must be collected in suitable
containers, and disposed of or processed properly.
Installation
15
ENL 6 HP http://www.ingersollrandproducts.com
¡Peligro!
¡Aire comprimido!
Ungolpedeairecomprimidoqueescaparepentinamenteoporcomponentesdelamáquinaquesalgan
disparados por su efecto puede suponer peligro de graves lesiones o muerte.
Medidas preventivas:
•Nosobrepasarlapresiónmáx.defuncionamiento(verplacaidenticativa)
• Realice los trabajos de mantenimiento siempre con la máquina despresurizada.
• Utilice solamente materiales resistentes a la presión para la instalación.
•Apretarbienlaconduccióndealimentación.Conduccióndesalida:mangueradepresióncortajadaaunatuberíaresistente
a la presión.
• Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido.
¡Precaución!
¡Mal funcionamiento!
UnainstalaciónincorrectaylafaltademantenimientopuedenprovocarqueelENLfuncionemal.El
condensadonoevacuadopuedeprovocardañosenlasinstalacionesyenlosprocesosdeproducción.
Medidas preventivas:
Una evacuación segura del condensado optimiza la calidad del aire comprimido de manera directa.
•Tengaencuentalospuntossiguientesparaprevenirdañosyparadasenlaproducción:
Respeto del uso apropiado y de los parámetros de servicio del ENL teniendo en cuenta el campo de aplicación de cada
caso (véase capítulo “Uso apropiado”).
• Observación estricta de las indicaciones de instalación y servicio facilitadas en este manual.
• Mantenimiento regular y control del ENL acorde a las indicaciones del manual.
Atención:
Tenga siempre en cuenta todas las indicaciones de peligro y advertencia facilitadas.
Observe igualmente todas las normativas e indicaciones de protección en el trabajo y contra incendios allí donde se efectúe
la instalación.
Utilice únicamente herramientas y materiales adecuados y en buen estado.
No utilice detergentes agresivos ni herramientas inadecuadas, como limpiadores a alta presión.
Tengaencuentaqueelcondensadopuedecontenercomponentesagresivosydañinosparalasalud.Poresarazóndeberá
evitarse siempre el contacto con la piel.
El condensado es un residuo que el usuario está obligado a gestionar correctamente, recogiéndolo en recipientes adecuados
para luego eliminarlo o tratarlo.
Instalación
16
ENL 6 HP
http://www.ingersollrandproducts.com
Danger !
Air comprimé !
Toutcontactavecdel'aircomprimés'échappantrapidementoudefaçonbrutaleoutoutcontactavecdes
partiesdel'installationprésentantunrisqued'éclatementpeutcauserdegravesblessuresouentraînerlamort
.
Mesures préventives :
• Ne pas dépasser la pression de service maximale (voir plaque signalétique).
Dépressuriserlepurgeuravanttouteinterventiond'entretienoudemaintenance.
• N'utiliser que du matériel d'installation résistant à la pression.
• Laconduited'amenéedoittoujoursêtreréaliséeentuyauterierigideetxe.Conduited'évacuation:exibledefaiblelon-
gueur,xéetreliéàunetuyauterie,tousdeuxrésistantàlapression.
• Veillez à ce qu'aucune personne ni objet ne risque d'être touché par le condensat ou l'air comprimé qui s'échappe.
Prudence !
Dysfonctionnementsauniveaudel'utilisation!
Encasd'installationincorrecteetdemaintenanceinsufsante,desdysfonctionnementspeuventapparaître
auniveauduENL.
Toutcondensatnonévacuérisqued'endommagerlesinstallationsetdeporteratteinteauxprocessusde
fabrication.
Mesures préventives :
Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualité de l'air comprimé.
Pour éviter tout endommagement et tout arrêt de production, il est impératif de respecter les consignes suivantes :
• Respecter scrupuleusement les instructions pour une utilisation conforme à l’usage prévu et les paramètres de fonction-
nement du ENL dans le contexte de son utilisation (consulter à cet effet le chapitre „Utilisation conforme à l’usage prévu“).
• Respecter scrupuleusement toutes les instructions d'installation et d'utilisation communiquées dans cette notice.
Respecter scrupuleusement la périodicité de maintenance et de contrôle du ENL selon les indications de ce manuel
d'utilisation.
Remarque :
Respectez impérativement toutes les informations relatives à un danger ou à un avertissement.
Respectez également toutes les prescriptions et consignes de sécurité relatives à la protection des travailleurs et à la protec-
tion incendie en vigueur au lieu d'installation en question.
Utilisez toujours l'outillage et le matériel appropriés et en bon état.
N'utilisez aucun produit de nettoyage agressif, ni d'appareils inadaptés, par exemple les nettoyeurs haute pression.
Notez bien que les condensats peuvent contenir des composants agressifs et néfastes pour la santé. C'est pourquoi, il est
recommandé d'éviter tout contact avec la peau.
Les condensats sont soumis à la réglementation sur les déchets. Ils doivent être collectés dans des récipients appropriés,
éliminés ou recyclés.
Installation
17
ENL 6 HP http://www.ingersollrandproducts.com
Perigo!
Ar comprimido!
Ocontatocomarcomprimidoescapandorápidaourepentinamenteoupeçasquerebentame/ouquenão
estãoxadaspodemprovocarferimentosgravesouamorte.
Medidas a serem tomadas:
• Não ultrapassar a pressão máxima de serviço (ver placa de características).
Trabalhosdemanutençãosédevemserexecutadoscomosistemadespressurizado.
• Só usar material de instalação à prova de pressão.
•Montardemodoxoatubulaçãodeadmissão.Tubulaçãodedescarga:mangueiradepressãocurtaeligadaaumtuboà
prova de pressão.
• Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa.
Cuidado!
Maufuncionamentonaaplicação!
Devidoaumainstalaçãoincorretaeaumamanutençãoinsucienteépossívelqueocorraomaufunciona-
mentodoENL.
Ocondensadonãoevacuadopoderácausardanosemequipamentoseemprocessosdefabricação.
Medidas a serem tomadas:
Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido.
Para evitar danos e falhas, favor observar sem falta:
•ObservaçãoprecisadautilizaçãodeacordocomanalidadeedosparâmetrosoperacionaisdoENLemligaçãocomo
casodeutilização(veraesterespeitoocapítulo„Utilizaçãodeacordocomanalidade“)
• Observação precisa das indicações sobre instalação e operação contidas nas presentes instruções
• Manutenção regular e controle do ENL segundo as indicações contidas nas presentes instruções
Observação:
Prestar atenção, sem falta, a todas as indicações de perigo e advertências.
Observar igualmente todos os regulamentos referentes à segurança no trabalho e à proteção contra incêndios.
Só devem ser usadas ferramentas apropriadas e materiais em perfeito estado.
Não utilizar produtos de limpeza agressivos nem aparelhos inadequados, tais como equipamentos de limpeza a alta pressão.
Não esquecer que os condensados podem conter elementos agressivos e nocivos à saúde. Por isso, evitar qualquer contato
com a pele.
Condensadoéumresíduosujeitoàdestinaçãonalquedeveráserrecolhidoemrecipientesapropriados,levadoàdestinação
naloutratado.
Instalação
18
ENL 6 HP
http://www.ingersollrandproducts.com
Installation • Instalación
Installation • Instalação
1.Feedpipeandttingatleast½"!
(internal dia > 0,51 inch)
2.Noltersinfeedline
3. Slope in feed line > 1%!
4. Only use ball valves!
5. Pressure: min. 12 psi or 18 psi!
(check type plate for correct pres-sure)
6. Short pressure hose!
7. For each yard of rising slope in the
outlet line, the required minimum
pressure will increase by 1.5 psi.
The rise of the outlet line must not
exceed 17 feet!
8. Collecting line min. ½ ‘’ with 1% slope
9. Inthecaseofinowproblems,install
venting line.
english
Note:
Deectorarea!
If drainage is to take place directly from a
line, it is advisable to arrange the piping
sothattheairowisdiverted.
Note:
Venting!
Ifthefeedlinecannotbelaidwithsuf-
cient slope, it will be necessary to install
a venting line!
wrong • no correcto
incorrect • incorrecto
correct • correcto
correct • correcto
Note:
Pressure differences!
Each condensate source must be drained
separately!
19
ENL 6 HP http://www.ingersollrandproducts.com
1. Diâmetro mínimo do tubo e acessórios
adutor ½"!
(diâmetro interno
<_
0,51 inch)
2. Nãomontarltrosnotuboadutor!
3. Declivedeauência>1%!
4. Só utilizar válvulas esféricas!
5. Pressão: no mínimo 12 ou 18 psi!
(Ver pressão indicada na placa
indicadora das características)
6. Tuboexívelcurto!
7. Por cada metro de subida no tubo
de descarga, a pressão mínima
necessária vai aumentando em 1.5
psi!
O tubo de descarga não deve exceder
17 feet de subida!
8. Assentar tubagem colectora com
diâmetro mínimo de ½" e 1% de declive!
9. Emcasodeproblemasdeauência,
instalar um tubo de eVACuação do ar.
português
Importante:
evacuaçãodoar!
Se o declive da auência não for su-
ciente, ou se houver outros problemas
de auência deve montar-se um tubo
de ventilação!
Importante:
diferençasdepressão!
Cada fonte de condensado terá que ser
drenada separadamente!
Importante:
desvio!
Quando se pretende efectuar a drena-
gem directamente através da tubagem,
deve-se prever um desvio para a cor-
rente de ar!
français
1. Tube d'amenée, au moins ½" !
(Diametre interieur > 0,51 inch)
2. Pasdeltresurl'amenée!
3. Pente de l'amenée >1% !
4. Utiliser uniquement des vannes à
boisseau sphérique !
5. Pression : minimum 12 ou 18 psi!
(relever la pression sur la plaque)
6. Flexible pression de faible longeur!
7. Pour chaque mètre de pente mon-
tante sur la conduite d'éVACuation, il
faut augmenter la pression minimale
requise de 1.5 psi!
Evacuation: longueur max. de la partie
montante : 17 feet !
8. Conduite collectrice :
au minimum ½" avec 1% de pente!
9. La conduite d'écoulement doit être
raccordée par un col de cygne sur la
conduite collectrice
1. Tubería de entrada y piezas de co-
nexión mín. ½"! (diá. interior
<_
0,51
inch)!
2.Noponganingunltroenlatubería
de entrada
3. La tubería de la entrada tiene que tener
una pendiente descendente constante
>1%
4. Utilice solamente llaves de paso
esféricas
5. Presión de funcionamiento mín. 12
psi o 18 psi (lea la presión indicada
enlaetiquetadeidenticación)
6. Tubo a presión corto
7. Por cada metro que asciende la tubería
de salida, se incrementa la presión
mínima de funcionamiento en 1.5
psi. Subida máxima de la tubería
de salida: 17 feet
8. Tubería colectora de los condensa-
dos: mín. ½" con pendiente descen-
dente constante 1%
9. Si existieran problemas de entrada,
instalar una tubería de ventilación.
español
Observe:
separacióndeloscondensados
Si se quiere purgar una tubería, es mejor,
si se realiza una desviación de la corrien-
te de aire comprimido.
Important :
chicane !
Si la purge doit s'effectuer directement sur
la tuyauterie, il faut prévoir une chicane
pour que le condensat ne soit pas entrainé
par le débit d'air comprimé !
Observe:
compensación
Si no hay suficiente pendiente des-
cendente constante en la tubería de la
entrada se tiene que montar una tubería
de compensación.
Important :
équilibraged'air!
Silapentedel'amenéen'estpassuf-
sante, il faut poser une conduite d'équi-
librage d'air !
Observe:
diferencialdepresión
Se tiene que purgar por separado cada
punto de purga.
Important :
différences de pression!
Chaque point de soutirage de condensat
doit être purgé individuellement pour éviter
le by-pass. Une purge continue ne serait
plus possible dans ces conditions !
20
ENL 6 HP
http://www.ingersollrandproducts.com
Installation • Instalación
Installation • Instalação
english
wrong • no correcto
incorrect • incorrecto
correct • correcto
correct • correcto
Note:
Continuous slope
It is important to avoid water pockets when
using a pressure hose as a feed line!
Note:
Continuous slope!
Water pockets must also be avoided
when laying a feed pipe.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Ingersoll-Rand ENL 6 HP Instructions For Installation And Operation Manual

Taper
Instructions For Installation And Operation Manual
Ce manuel convient également à

dans d''autres langues