Astria Fireplaces DRC3000 Instruction Sheet

Catégorie
Cheminées
Taper
Instruction Sheet

Ce manuel convient également à

INNOVATIVE HEARTH PRODUCTS • DIRECT VENT GAS FIREPLACES • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
900285-06B IHP.us.com 1
INSTALLATION INSTRUCTIONS FOR GAS CONVERSION KITS
FOR USE WITH DIRECT VENT GAS FIREPLACES
[MODELS ASTRIA GEMINI AND SUPERIOR DRT-DRC3000 AND MHD SERIES]
P/N 900285-06
Rev. B 10/2020
HEARTH PRODUCTS
KITS AND ACCESSORIES
GAS CONVERSION KIT
DIRECT GAS FIREPLACES
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may
result; causing property damage, personal injury, or loss of life. The qualified service agency is responsible
for the proper installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. The
qualified service agency performing this installation assumes responsibility for this conversion.
AVERTISSEMENT
Cette trousse de conversion doit être installée par un technicien agréé, selon les instructions du fabricant et
selon toutes les exigences et tous les codes pertinents de l’autorité compétente. Assurez-vous de bien suivre
les instructions dans cette notice pour réduire au minimum le risque d’incendie, d’explosion ou la production
de monoxyde de carbone pouvant causer des dommages matériels, des blessures ou la mort. Le tecnicien
agréé est responsable de l’installation de cette trousse. L’installation n’est pas adéquate ni complète tant que
le bon fonctionnement de l’appareil converti n’a pas été vérifié selon les instructions du fabricant fournies
avec la trousse. Le fournisseur de service qualifié ayant réalisé l’installation assume les responsabilités
liées à la conversion.
In Canada:
The conversion shall be carried out in accordance with the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements of the CAN/CGA-B149.1 Installation code.
La conversion devra être effectuée conformément aux recommandations des autorités provinciales ayant
juridiction et conformément aux exigences du code d’installation CAN/CGA-B149.1.
Gas conversion kits are available to adapt your fireplace from the use of one type of gas to the use of another. These
kits contain all the necessary components needed to complete the task including labeling that must be affixed to
ensure safe operation.
Refer to the instructions provided with the conversion kit when performing any gas conversion.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
INNOVATIVE HEARTH PRODUCTS • DIRECT VENT GAS FIREPLACES • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
IHP.us.com 900285-06B2
WARNING
The gas supply shall be shut OFF prior to disconnecting the electrical power, before
proceeding with the conversion.
AVERTISSEMENT
Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez
l’alimentation electrique.
Table 1: Millivolt Systems,Natural Gas To Propane Gas Conversion Kits Table 2: Millivolt Systems, Propane Gas to Natural Gas Conversion Kits
Models Catalog Number Models Catalog Number
33” Models F2168 33” Models F2166
35” Models F2173 35” Models F2171
40” Models F2174 40” Models F2172
45” Models F2180 45” Models F2178
Table 3: Electronic Systems, Natural Gas To Propane Gas Conversion Kits Table 4: Electronic Systems, Propane Gas To Natural Gas Conversion Kits
Models Catalog Number Models Catalog Number
33” Models F2167 33” Models F2165
35” Models F2175 35” Models F2169
40” Models F2176 40” Models F2170
45” Models F2179 45” Models F2177
KIT CONTENTS
Pilot Orifice, Burner Orifice, Gas Conversion Kit (containing Pressure Regulator Assembly, split-flow orifice (in electronic
models), two (2) screws, Gas Conversion Identification Label, Installation Instructions
REQUIRED TOOLS
5/32 Allen Wrench, Torx Bit (T20 with 1/4” shank and center hole) or Flat Blade Screwdriver, 1/2” Open-End Wrench
Installing Gas Conversion Kits
1. TURN OFF THE GAS SUPPLY TO THE FIREPLACE and disconnect power supply at the circuit breaker. Ensure
fireplace is cold.
2. Open the lower control compartment at the bottom front of the fireplace door by holding the control
compartment door by the top and gently lifting it up, then rotating it away from the fireplace.
3. Remove the barrier and front glass door/frame from the fireplace.
4. Remove the logs / glass media. If necessary, remove the log grate.
NOTE: Exercise care so as not to break the logs.
5. If your unit has ceramic or porcelain panels, please remove. If there are no panels, please skip to the next step.
6. Remove the sub floor screws and subfloor.
7. Remove the two (2) screws securing the burner assembly with attached shutter assembly. Remove the burner
assembly and air shutter assembly with the attached venturi tube by carefully sliding the burner tube to the left -
clear the burner from the orifice.
8. Rotate the burner to release the air shutter adjustment rod from the air shutter lever. Set screws and burner
aside for later reinstallation.
INNOVATIVE HEARTH PRODUCTS • DIRECT VENT GAS FIREPLACES • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
900285-06B 3
IHP.us.com
9. Refer to the instructions provided with the SIT Regulator Conversion Kit, and Figure 1. Using a Torx T20
driver (with 1/4” shank) or slotted screwdriver, remove and discard the three pressure regulator mounting
screws, pressure regulator tower, the diaphragm assembly (if applicable) and the spring. Discard all removed
components.
Figure 1: Valve Regulator Conversion
Pressure
Regulator
Remove
These
Components
Figure 2: Electronic (left) and Millivolt (right) Pilots Figure 3: Burner Orifice
10. Remove the burner orifice from the manifold and replace it with the one provided in the kit (Figure 3).
NOTE: See Table 5 for burner orifice sizes.
11. Remove and replace split-flow orifice (in electronic units, see Table 8).
12. Use pipe joint compound or Teflon® tape on all pipe fittings before installing.
NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds
on flare fittings.
13. Retrieve the burner and hold the venturi tube above the orifice. Place the shutter adjusting rod in the slot of the
shutter arm (Figure 4). Set the burner assembly into its position and secure with the two screws previously
removed.
Pilot
Orifice
Clip
Pilot
Oriface
Figure 4: Air shutter adjustment rod
Burner
Tube
Adjustment
Set-Screw
Air Shutter
Adjustment
Rod Down
(Fully-Open
Position)
Adjustment
Rod Up
(Fully-Closed
Position)
NOTE: ALWAYS REFER TO YOUR
INSTALLATION INSTRUCTION AND
CARE AND OPERATIONS MANUAL
(IICO) FOR COMPREHENSIVE IN-
STRUCTIONS ON THIS INSTALLA-
TION AS IT MAY RELATE TO OTHER
TOPICS.
Parts to be
removed
Electronic Millivolt
Pressure
Regulator
Remove
these
components
INNOVATIVE HEARTH PRODUCTS • DIRECT VENT GAS FIREPLACES • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
IHP.us.com 900285-06B
4
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 900285-06 Rev. B 10/2020
Innovative Hearth Products reserves the right to make changes at any time, without notice, in design,
materials, specifications, and prices, and also to discontinue colors, styles, and products.
Consult your local distributor for fireplace code information.
Figure 5: Conversion Label (sample)
14. Reinstall the sub floor with screws.
15. Reassemble the remaining components.
16. Turn on gas supply and test for gas leaks. Never check for leaks with a flame!
17. Relight the main burner. Verify proper burner ignition and operation.
18. Inspect the pilot system for proper flame. The pilot flame should engulf the flame sensor.
19. Using a manometer, test the inlet and manifold gas pressures (Table 4 and Table 5). NOTE: Always test
pressures with the valve regulator control at the highest setting.
20. Affix the appropriate conversion label (See Figure 5).
21. Replace door and barrier - insure proper operation with both door and barrier in place.
Table 5: Burner Orifice Sizes, Elevation 0–4500 ft ( 0–1372 m)
Model Natural Gas
drill size
Propane
drill size
33” Models #49 (0.073”)* #57 (0.043”)*
35” Models #48 (0.076”)* #56 (0.0465”)*
40” Models #44 (0.086”)* #55 (0.052”)*
45” Models #43 (0.089”)* #54 (0.055”)*
* Standard size installed at factory
Table 6: Inlet Gas Supply Pressure
Fuel Minimum Maximum
Natural Gas 5” WC / (1.25 kPa) 10.5” WC / (2.61 kPa)
Propane 11.0” WC / (2.74 kPa) 13.0” WC / (3.23 kPa)
Table 7: Manifold Gas Supply Pressure
Fuel Pressure
Natural Gas 3.5” WC / (0.87 kPa)
Propane 10.0” WC / (2.49 kPa)
Table 8: Split Flow Orifices in Electronic Models
Fuel 33” and 35” Models 40” and 45” Models
Natural Gas #51 (0.067”) #49 (0.073”)
Propane #61 (0.039”) #56 (0.047”)
1769 East Lawrence Street • Russellville, AL 35654