Design & Quality Engineering GROHE Germany
93.905.131/ÄM 226062/09.12
Grohtherm 1000
Grohtherm 1000
34 438
34 439
F
.....1
I
.....5
N
.....9
GR
.....13
TR
.....17
BG
.....21
RO
.....25
GB
.....2
NL
.....6
FIN
.....10
CZ
.....14
SK
.....18
EST
.....22
RUS
.....26
D
.....3
S
.....7
PL
.....11
H
.....15
SLO
.....19
LV
.....23
RUS
.....27
E
.....4
DK
.....8
UAE
.....12
P
.....16
HR
.....20
LT
.....24
I
1
2
2
m
m
3
0
m
m
C
2
E
3
38 °C
A
B
C
D
4
G
H
J
K
L
F
L
5
min.
max.
Please pass these instructions on to the end user of the fitting.
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
34 438
34 439
II
1
F
Domaine d'application
Les robinetteries thermostatiques sont conçues pour fournir de
l'eau chaude avec des accumulateurs sous pression et
permettent d'obtenir une température de l'eau extrêmement
précise. Si la puissance est suffisante (à partir de 18 kW,
ou 250 kcal/min), des chauffe-eau instantanés électriques ou
au gaz conviennent également.
Les thermostats ne peuvent pas être utilisés avec des
accumulateurs sans pression (chauffe-eau à écoulement
libre). Tous les thermostats sont réglés en usine sur une
pression dynamique de 3 bars. Si des différences de
température devaient apparaître, régler le thermostat en
fonction des conditions locales d'utilisation (voir Réglage).
Caractéristiques techniques
Pression dynamique minimale sans
résistance hydraulique en aval 0,5 bar
Pression dynamique minimale avec
résistance hydraulique en aval 1 bar
Pression de service maxi. 10 bars
Pression dynamique recommandée 1 à 5 bars
Pression d’épreuve 16 bars
Débit à une pression dynamique de 3 bars
Robinet env. 20 l/min
Douche env. 14 l/min
Température d'eau maxi. à l'arrivée d'eau chaude 80 °C
Température d'admission maxi. recommandée
(économie d'énergie) 60 °C
Verrouillage de sécurité 38 °C
Température de l'eau chaude au raccord
d'alimentation au moins 2 °C de plus que
la température de l'eau mitigée
Raccordement eau froide à droite
Raccordement eau chaude à gauche
Débit minimal = 5 l/min
Installer un réducteur de pression en cas de pressions
statiques supérieures à 5 bars.
Installation
Bien rincer les canalisations avant et après l’installation
(respecter la norme EN 806)!
Monter les raccordements S et visser la robinetterie, voir
volet I, fig. [1].
Tenir compte de la cote du schéma sur le volet I.
La saillie peut être augmentée à l'aide d'une rallonge
de 20mm, voir volet II, pièces de rechange, réf. 07 130.
Raccordement inversé (chaud à droite - froid à gauche).
Remplacer la cartouche compacte de thermostat (U),
voir pièces de rechange, volet II, réf. 47 175 (1/2”).
Réglage
Réglage de la température, voir fig. [2] et [3.
1.Ouvrir le robinet d'arrêt et, à l'aide d'un thermomètre,
mesurer la température de l'eau mitigée, voir fig. [2].
2.Déposer le capot (A) en faisant levier, voir fig. [3].
3.Desserrer la vis (B).
4.Extraire la poignée de sélection de la température (C).
5.Tourner l'écrou de régulation (D) jusqu'à ce que l'eau
mitigée atteigne 38 °C.
6.Emboîter la poignée de sélection de la température (C) de
telle façon que le bouton (E) soit orienté vers le haut,
voir fig. [2].
7.Visser la vis (B), voir fig. [3].
8.Remettre le capot (A).
Limitation de la température
La température est limitée à 38 °C par le verrouillage de
sécurité. Il est possible d'aller au-delà de la limite des 38 °C et
d'obtenir une température plus élevée en appuyant sur la
touche (E).
Réglage de la butée économique
Réglage du débit, voir volet I, fig. [4] et [5].
Le débit d'eau est limité par une butée réglée en usine.
Appuyer sur le bouton (F) pour dépasser la butée et obtenir
une plus grande quantité d'eau, voir fig. [4].
Pour modifier la butée, procéder comme suit:
1.Fermer le robinet d'arrêt.
2.Déposer le capot (G) en faisant levier.
3.Desserrer la vis (H) et déposer la poignée d’arrêt (J).
4.Retirer l'adaptateur rainuré (K) et la butée économique (L).
5.Mettre en place la butée économique (L) dans la position
voulue, voir fig. [5] pour connaître les réglages possibles.
6.Insérer l'adaptateur rainuré (K), voir fig. [4].
7.Emboîter la poignée d'arrêt (J) de telle façon que le
bouton (F) soit orienté vers le haut.
8.Visser la vis (H).
9.Insérer à nouveau le capot (G).
Vérifier le fonctionnement de l'inverseur automatique (M),
voir volet III, fig. [6].
La fermeture du mitigeur entraîne l'inversion automatique de la
douche au bec.
Attention en cas de risque de gel
En cas de mise hors gel, la purge simple de l’installation n’est
pas suffisante pour protéger la robinetterie. Lors de la purge
de l’installation principale, vous devez vider le corps
thermostatique dont les raccordements d'eau froide et d'eau
chaude sont équipés de clapets anti-retour. Pour cela, ôter le
thermostat du mur.
Maintenance
Vérifier toutes les pièces, les nettoyer, les remplace éventuel-
lement et les lubrifier avec la graisse spéciale pour robinets.
Couper l'alimentation en eau chaude et en eau froide.
I. Clapet anti-retour (R) ou (S), voir volet III fig. [7].
Dévisser l'ergot de raccordement (P) en tournant vers la
droite avec une clé Allen de 12mm (pas de vis à gauche).
Le montage s'effectue dans l'ordre inverse de la dépose.
II. Cartouche compacte de thermostat (U), voir volet III,
fig. [8].
Desserrer l’anneau fileté (T) à l’aide d’un outil de 34mm.
Déposer la cartouche compacte de thermostat (U) via
l’encoche (U1) en faisant levier.
Dévisser l’anneau fileté (T).
Le montage s'effectue dans l'ordre inverse de la dépose.
Respecter la position de montage de la cartouche
compacte de thermostat (U), voir détail (U2).
Après tout travail de maintenance sur la cartouche compacte
de thermostat, un réglage est nécessaire (voir Réglage).
III. Tête en céramique (V), voir volet III, fig. [9].
Le montage s'effectue dans l'ordre inverse de la dépose.
IV. Mousseur (13 941), le dévisser et le nettoyer, voir volet II.
Pièces de rechange, voir volet II ( * = accessoires spéciaux).
Entretien
Les indications relatives à l'entretien de cette robinetterie
figurent sur la notice jointe à l'emballage.
2
GB
Application
Thermostat mixers are designed for hot water supply via
pressurised storage heaters and, utilised in this way, provide
the best temperature accuracy. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in conjunction with
non-pressurised storage heaters (displacement water
heaters).
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting).
Specifications
Minimum flow pressure without
downstream resistances 0.5 bar
Minimum flow pressure with
downstream resistances 1 bar
Max. operating pressure 10 bar
Recommended flow pressure 1 - 5 bar
Test pressure 16 bar
Flow rate at 3 bar flow pressure
Bath approx. 20 l/min
Shower approx. 14 l/min
Max. water temperature at hot water supply 80 °C
Recommended max. flow temperature (energy saving) 60 °C
Safety stop 38 °C
Hot water temperature at supply connection min. 2 °C higher
than mixed water temperature
Cold water connection right
Hot water connection left
Minimum flow rate = 5 l/min
If static pressure exceeds 5 bar, a pressure reducing valve
must be fitted.
Installation
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Install S-unions and screw-mount the mixer, see fold-out page I,
Fig. [1].
Refer to the dimensional drawing on fold-out page I.
The projection can be increased by 20mm with an extension,
see Replacement Parts, fold-out page II, Prod. no. 07 130.
Reversed connection (hot on right - cold on left).
Replace thermostatic compact cartridge (U), see Replacement
parts, fold-out page II, Prod. no.: 47 175 (1/2”).
Adjusting
Temperature adjustment, see Figs. [2] and [3].
1.Open the shut-off valve and check the temperature of the
water with a thermometer, see Fig. [2].
2.Lever out cap (A), see Fig. [3].
3.Remove screw (B).
4.Detach temperature control handle (C).
5.Turn regulating nut (D) until the water temperature has
reached 38 °C.
6.Install temperature control handle (C) so that button (E)
points towards the front, see Fig. [2].
7.Screw in screw (B), see Fig. [3].
8.Refit cap (A).
Temperature limitation
The safety stop limits the temperature range to 38 °C. The 38 °C
limit can be overridden by pressing the button (E).
Adjusting the economy stop
Volume adjustment, see fold-out page I, Figs. [4] and [5].
The flow rate is limited by a stop adjusted at the factory. If a
higher flow rate is desired, the stop can be overridden by
pressing the button (F), see Fig. [4].
To adjust the stop, proceed as follows:
1.Close shut-off valve.
2.Lever out cap (G).
3.Remove screw (H) and detach shut-off handle (J).
4.Remove splined adapter (K) and economy stop (L).
5.Reinstall economy stop (L) in the desired position. For
adjustment range, see Fig. [5].
6.Fit splined adapter (K), see Fig. [4].
7.Fit shut-off handle (J) so that the button (F) points towards
the front.
8.Screw in screw (H).
9.Refit cap (G).
Check operation of automatic diverter (M), see fold-out
page III, Figs. [6].
Flow is diverted automatically from shower outlet to bath inlet
when the fitting is closed.
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Maintenance
Inspect and clean all parts, replace if necessary and lubricate
with special valve grease.
Shut off the hot and cold water supply.
I. Non-return valve (R) or (S), see fold-out page III, Fig. [7].
Remove connection nipple (P) by turning clockwise (left-hand
thread) using a 12mm allen key.
Install in reverse order.
II. Thermostatic compact cartridge (U), see fold-out page III,
Fig. [8].
Loosen screw ring (T) using a 34mm tool.
If necessary, lever out thermostatic compact cartridge (U)
via recess (U1).
Remove screw ring (T).
Install in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (U), see detail (U2).
Readjustment is necessary after every maintenance operation
on the thermostatic compact cartridge (see Adjusting).
III. Ceramic headpart (V), see fold-out page III, Fig. [9].
Install in reverse order.
IV. Unscrew and clean mousseur (13 941) see fold-out
page II.
Replacement Parts, see fold-out pages II( * = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
3
D
Anwendungsbereich
Thermostat-Batterien sind für eine Warmwasserversorgung
über Druckspeicher konstruiert und bringen so eingesetzt
die beste Temperaturgenauigkeit. Bei ausreichender Leistung
(ab 18 kW bzw. 250 kcal/min) sind auch Elektro- bzw. Gas-
durchlauferhitzer geeignet.
In Verbindung mit drucklosen Speichern (offene Warmwasser-
bereiter) können Thermostate nicht verwendet werden.
Alle Thermostate werden im Werk bei einem beidseitigen
Fließdruck von 3 bar justiert.
Sollten sich aufgrund von besonderen Installations-
bedingungen Temperaturabweichungen ergeben, so ist der
Thermostat auf die örtlichen Verhältnisse zu justieren (siehe
Justieren).
Technische Daten
Mindestfließdruck ohne
nachgeschaltete Widerstände 0,5 bar
Mindestfließdruck mit
nachgeschalteten Widerständen 1 bar
Max. Betriebsdruck 10 bar
Empfohlener Fließdruck 1 - 5 bar
Prüfdruck 16 bar
Durchfluss bei 3 bar Fließdruck
Wanne ca. 20 l/min
Brause ca. 14 l/min
Max. Wassertemperatur am Warmwassereingang 80 °C
Empfohlene max.Vorlauftemperatur (Energieeinsparung)60 °C
Sicherheitssperre 38 °C
Warmwassertemperatur am Versorgungsanschluss min. 2 °C
höher als Mischwassertemperatur
Kaltwasseranschluss rechts
Warmwasseranschluss links
Mindestdurchfluss = 5 l/min
Zur Einhaltung der Geräuschwerte nach DIN 4109 ist bei
Ruhedrücken über 5 bar ein Druckminderer einzubauen.
Installation
Rohrleitungssystem vor und nach der Installation
gründlich spülen (DIN 1988/DIN EN 806 beachten)!
S-Anschlüsse montieren und Batterie anschrauben, siehe
Klappseite I, Abb. [1].
Maßzeichnung auf Klappseite I beachten.
Die Ausladung kann mit einer Verlängerung um 20mm
vergrößert werden, siehe Ersatzteile Klappseite II, Bestell-
Nr.: 07 130.
Seitenverkehrter Anschluss (warm rechts - kalt links).
Thermostat-Kompaktkartusche (U) austauschen, siehe
Ersatzteile Klappseite II, Best.-Nr.: 47 175 (1/2”).
Justieren
Temperatur-Einstellung, siehe Abb. [2] und [3].
1.Absperrventil öffnen und Temperatur des auslaufenden
Wassers mit Thermometer messen, siehe Abb. [2].
2.Abdeckkappe (A) aushebeln, siehe Abb. [3].
3.Schraube (B) lösen.
4.Temperaturwählgriff (C) abziehen.
5.Reguliermutter (D) solange drehen, bis das auslaufende
Wasser 38 °C erreicht hat.
6.Temperaturwählgriff (C) so aufstecken, dass die Taste (E)
nach vorn zeigt, siehe Abb. [2].
7.Schraube (B) einschrauben, siehe Abb. [3].
8.Abdeckkappe (A) wieder aufstecken.
Temperaturbegrenzung
Der Temperaturbereich wird durch die Sicherheitssperre
auf 38 °C begrenzt. Durch Drücken der Taste (E) kann
die 38 °C-Sperre überschritten werden.
Einstellen des Sparanschlages
Mengen-Einstellung, siehe Klappseite I Abb. [4] und [5].
Die Wassermenge wird durch einen werkseitig eingestellten
Anschlag begrenzt. Wird eine größere Wassermenge
gewünscht, so kann durch Drücken der Taste (F) der
Anschlag überschritten werden, siehe Abb. [4].
Soll der Anschlag verstellt werden, ist wie folgt vorzugehen:
1.Absperrventil schließen.
2.Abdeckkappe (G) aushebeln.
3.Schraube (H) lösen und Absperrgriff (J) abziehen.
4.Riefenadapter (K) und Sparanschlag (L) abziehen.
5.Sparanschlag (L) in der gewünschten Position aufstecken,
möglicher Verstellbereich siehe Abb. [5].
6.Riefenadapter (K) aufstecken, siehe Abb. [4].
7.Absperrgriff (J) so aufstecken, dass die Taste (F) nach vorn
zeigt.
8.Schraube (H) einschrauben.
9.Abdeckkappe (G) wieder aufstecken.
Funktion der automatischen Umstellung (M) prüfen, siehe
Klappseite III Abb. [6].
Schließen der Armatur bewirkt automatisches Umschalten von
Brauseauslauf auf Wanneneinlauf.
Achtung bei Frostgefahr
Bei Entleerung der Hausanlage sind die Thermostate
gesondert zu entleeren, da sich im Kalt- und Warmwasser-
anschluss Rückflussverhinderer befinden. Hierbei ist der
Thermostat von der Wand abzunehmen.
Wartung
Alle Teile prüfen, reinigen evtl. austauschen und mit Spezial-
Armaturenfett einfetten.
Kalt- und Warmwasserzufuhr absperren.
I. Rückflussverhinderer (R) oder (S), siehe
Klappseite III Abb [7].
Anschlussnippel (P) mit Innensechskantschlüssel 12mm
durch Rechtsdrehung ausschrauben (Linksgewinde).
Montage in umgekehrter Reihenfolge.
II. Thermostat-Kompaktkartusche (U), siehe Klappseite III
Abb. [8].
Schraubring (T) mit Werkzeug 34mm lösen.
Thermostat-Kartusche (U) gegebenenfalls über die
Ausnehmung (U1) aushebeln.
Schraubring (T) abschrauben.
Montage in umgekehrter Reihenfolge.
Einbaulage der Thermostat-Kompaktkartusche (U)
beachten, siehe Detail (U2).
Nach jeder Wartung an der Thermostat-Kartusche ist eine
Justierung erforderlich (siehe Justieren).
III. Keramik-Oberteil (V), siehe Klappseite III Abb. [9].
Montage in umgekehrter Reihenfolge.
IV. Mousseur (13 941) ausschrauben und säubern, siehe
Klappseite II.
Ersatzteile, siehe Klappseite II ( * = Sonderzubehör).
Pflege
Die Hinweise zur Pflege dieser Armatur sind der beiliegenden
Pflegeanleitung zu entnehmen.
III
6
M
V
1
7
m
m
9
P
R
S
3
0
m
m
1
2
m
m
7
8
U
U
U1
U2
T
3
4
m
m
*19 332
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE Grohtherm 1000 34 438 Guide de démarrage rapide

Catégorie
Articles sanitaires
Taper
Guide de démarrage rapide