Baumer LBFS Mode d'emploi

Taper
Mode d'emploi
Level measurement
CleverLevel
®
LBFS
Point level detection
EN Operating Instructions 3
DE Betriebsanleitung 17
FR Manuel de mise en service 31
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
Type plate / Typenschild / Plaque d‘identication
Type
Type of sensor
Matr.
Material number
In
Input voltage and
power consumption
Out
PNP or NPN, customer-specic
Maximum external load
Tamb
Ambient temperature
S/N
Serial number
Date
Date of manufacture
Do not dispose of in household waste
Conformity with EU directives
Approvals, type-specic
Type
Sensortyp
Matr.
Materialnummer
In
Eingangsspannung und
Stromverbrauch
Out
PNP oder NPN, kundenspezisch
Maximale externe Last
Tamb
Umgebungstemperatur
S/N
Seriennummer
Date
Herstellungsdatum
Nicht im Hausmüll entsorgen
Konformität mit EU-Richtlinien

Zulassungen, typspezifisch
Type
Type de capteur
Matr.
f. mat.
In
Tension d’entrée et consommation
électrique
Out
PNP ou NPN, en fonction du client
Charge externe maximale
Tamb
Température ambiante
S/N
Numéro de série
Date
Date de fabrication
Ne pas jeter avec les ordures
ménagères
Conformité avec les directives
européennes
Autorisations, selon le type
LBFS-00100.0
2 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
Table of contents
Table of contents .................................................. 3
1. Safety .......................................................... 3
2. Construction and function ........................... 3
3. Symbols in warning signs ............................ 4
4. Transport and storage ................................. 4
5. Assembly ..................................................... 4
6. Permissions ................................................. 8
7. Electrical connection ................................... 9
8. Electrical connection in explosion hazard
areas ........................................................... 9
9. Conguration ..............................................12
10. Operation ...................................................12
11. Cleaning, maintenance and repair..............13
12. Disposal .....................................................13
13. Accessories ................................................13
14. Technical data ............................................13
15. Factory settings and user settings ............ 16
1. Safety
Intended use
The sensor must be used solely for the level
detection of liquids and solids with a dielectric
constant of at least 1.5.
The sensor must only be used for media against
which the housing material and sensor tip are
resistant.
Staff qualication
Only use staff who are trained for the activities
described. This applies in particular to assembly,
installation and explosion protection. Make sure
that the staff have read and understood these
instructions.
Technical condition
Use the sensor only when in perfect technical
condition. Only use Baumer accessories.
Baumer will accept no liability for other
manufacturers’ accessories.
Risk of burns from hot media
During operation the sensor housing may warm
up to over 50 °C. When working with hot media
provide protection against burns.
Explosion hazard areas
Ensure that safety requirements are complied with.
Do not use equipment that would be exposed to
hard impacts.
2. Construction and function
1 2 3
Fig. 1. Construction
f
L
C
µC
Fig. 2. Function
1 Sensor tip
2 LED
3 Connection using a M12-A 4-pin connector,
or a cable outlet
An electrode integrated into the sensor tip forms
a capacitor with the environment. The medium
determines the capacity value depending on
its dielectric constant (DC values). A resonant
circuit occurs together with a coil in the sensor
electronics. Depending on the resonance
frequency measured and the programmable trigger
threshold, the switch signal is activated.
www.baumer.com
3 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
3. Symbols in warning signs
Symbol Warning term Explanation
DANGER
In situations which cause death or serious injuries.
WARNING
In situations which can cause death or serious injuries.
CAUTION
In situations which can cause light or medium injuries.
ATTENTION
For material damage
4. Transport and storage
f
Check packaging and sensor for damage.
f
In the event of damage: Do not use sensor.
f
Store sensor where it will be secure against
shock.
Storage temperature: -40...+85 °C
Relative humidity: < 98 %
5. Assembly
2
4
1
3
4
4
Fig. 3. General mounting options
1 Overll protection
2 Limit level, max.
3 Limit level, min.
4 Run-dry protection
The sensor can be mounted on any point in the
vessel.
A sensor mounted at the top of the vessel (1)
ensures against overlling. Sensors attached
further down detect a maximum (2) or minimum (3)
limit level. A sensor attached at the bottom or on
the outfeed pipe (4) can protect a pump against dry
running.
4 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
1
2
3
Fig. 4. Mounting of extended sensors
1 Limit level: Mounting with a tube (version 5)
2 Overll protection (Type K, L)
3 Pasty or powdered media
limit level (version K, L)
Dip length:
Type K: 82 mm (xed)
Type L: 15…228 mm (adjustable)
The adjustable version L allows bridging across
tank insulation.
In pasty or powdered media, the greater dip depth
renders the sensor less susceptible to caking.
5.1 Installation for industrial applications
DANGER
Risk of injury from hazardous medium
f
Wear protective equipment for hazardous media (such as acids, alkalis).
f
Empty vessel and pipelines before mounting.
PTFE
1
2
LBFS with the following process connections:
G 1/2 A ISO 228-1 BSC (BCID G07)
G 3/4 A ISO 228-1 (BCID G10)
G 1 A ISO 228-1 (BCID G11)
1/2-14 NPT (BCID N02)
3/4-14 NPT (BCID N03)
9 Vessel and pipelines are free of media.
f
Seal thread on sensor with Teon tape (PTFE).
f
Screw in sensor.
Tightening torque G xx A: 30 Nm max.
Tightening torque xx-14 NPT: 20 Nm max.
www.baumer.com
5 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
LBFS with the following process connections:
G 1/2 A ISO 228-1 BSC (BCID G07) with
industrial weld-in sleeve for universal use, Ø 30 x
26 (ZPW1-711, ZPW1-721)
G 1/2 A hygienic (BCID A03) with weld-in sleeve
or adapter from Baumer
For these process connections, do not seal with
Teon tape (PTFE) or elastomer.
9 Vessel and pipelines are free of media.
9 Adapter or weld-in sleeve are mounted free of
dead space.
f
Screw in sensor.
Tightening torque: 15…20 Nm
1
2
LBFS with the following process connections:
G 1/2 A DIN 3852-E (BCID G51)
9 Vessel and pipelines are free of media.
f
Push the sealing ring on.
f
Screw in sensor.
Tightening torque: 15…20 Nm
1
2
LBFS with the following process connections:
G 1/2 A ISO 228-1 for internal installation (BCID
T10)
9 Vessel and pipelines are free of media.
f
Push the sealing ring on.
f
Screw in sensor.
Tightening torque: 15…20 Nm
6 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
LBFS with the following process connections:
M18x1 ISO 965 (BCID M11)
f
Tighten the nuts on both sides.
Tightening torque: 15…20 Nm
5.2 Installation for hygiene applications
WARNING
Danger to health from contaminated medium
f
Only use weld-in sleeves or adapters from Baumer.
f
Do not seal process connections with Teon tape (PTFE) or elastomer.
f
Welding work must only be carried out by welders trained in the area of hygiene.
LBFS with the following process connection:
G 1/2 A hygienic (BCID A03)
9 The weld-in sleeve or adapter must be
hygienically mounted and internally ush.
9 Weld seams are smoothed out to Ra < 0.8 µm.
9 Leakage hole points downwards.
f
Screw in sensor.
Tightening torque: 10…15 Nm
1
2
LBFS with the following process connection:
G 1/2 A hygienic with adjustable connection
(BCID A03)
9 The weld-in sleeve or adapter must be
hygienically mounted and internally ush.
9 Weld seams are smoothed out to Ra < 0.8 µm.
9 Leakage hole points downwards.
9 The clamping rings must be in faultless condition
(if they are deformed, replace both clamping
rings).
f
Push the wide clamping ring on to the guide
tube.
f
Push the narrow clamping ring on to the guide
tube.
f
Position the sensor.
f
Adjust the dip depth.
Projecting length: 15…228 mm
f
Tighten the screw-in pin.
Tightening torque: 10…15 Nm
www.baumer.com
7 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
Example of mounting with weld-in sleeve ZPW3-321
1
1
1
2
1
2
ZPW3-321
Leakage hole
Example of mounting with weld-in sleeve ZPW3-326 or ZPW3-327
170°
190°
6. Approvals
The EHEDG certicate is only valid in connection with the appropriate installation
parts. These are marked with the "EHEDG Certied" logo.
The 3-A Sanitary Standard requirements are only met with the appropriate
installation parts. These are marked with the 3-A logo.
Approved for explosion hazard areas when installed as specied. For barriers,
Baumer recommends: PROFSI3-B25100-ALG-LS.
Approved by Underwriter Laboratories (UL) for use in the USA and Canada as an
industrial control device.
Certied by DNV GL for ships and offshore platforms.
Approved as an electronic device for railway applications.
For more information about approvals and certication, please see the product page on www.baumer.com.
8 / 48
www.baumer.com
WHG certified for leakage and overfill protection. All documentation must be available
at the place of use and can be found on the product page on www.baumer.com
WHG
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
7. Electrical connection
9 A voltage supply of 12 V to 30 V DC is provided.
f
Switch off supply voltage.
f
Connect sensor in accordance with the pin
assignment.
Terminal assignment
1
2
43
Housing dimensions avail-
able only for a plug con-
nector in stainless steel
Output
type
Equivalent circuit Function M12-A
4-pin
Cable outlet
PNP
SW1 (NC)
GND(0V)
+Vs
SW1 (NO)
+ Vs 1 brown
SW1 (NO) 4 black
SW1 (NC) 2 white
GND (0 V) 3 blue
NPN
SW1 (NC)
GND(0V)
+Vs
SW1 (NO)
+ Vs 1 brown
SW1 (NO) 4 black
SW1 (NC) 2 white
GND (0 V) 3 blue
8. Electrical connection in explosion hazard areas
Depending on the variant, the LBFS is approved for most explosion hazard areas.
DANGER
Risk of fatal accident due to a wrongly connected sensor
f
In explosive gas atmospheres of zone 0 or 1, use Baumer isolation barriers or Zener barriers.
f
In explosive dust atmospheres, use insulated cable to IP67.
f
Allow only persons trained in explosion protection to perform the installation.
8.1 Explosive gas atmospheres zone 0 and 1
The LBFS can be used in explosion hazard areas of zone 0 or zone 1. Sensors with PNP can use Baumer
isolation barriers which are easy to install. Sensors with NPN must use Zener barriers.
Approval for LBFS-1xxxx.x: ATEX II 1G Ex ia IIC T4/T5
Approval for LBFS-4xxxx.x: ATEX II 1G Ex ia IIC T4/T5 and ATEX II 1D Ex ta IIIC T100 °C Da
www.baumer.com
9 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
LBFS-1xxx1.x (PNP):
f
Use PROFSI3-B25100-ALG-LS isolation
barriers for the connection.
LBFS-1xxx2.x (NPN):
f
Use Zener barriers for the connection.
LBFS-4xxxx.x and additional dust
atmospheres:
f
Use insulated cable to IP67.
f
Secure cables with external strain relief at a
distance 5 centimeters from the sensor.
All LBFS in zone 0 and zone 1
f
Comply with the following temperatures,
connection values and circuit diagram.
ATEX II 1 G Ex ia IIC T4/T5
Highest values for
selection of barriers
Ui: 30 V DC
Ii: 100 mA
Pi: 0,75 W
Internal capacitance: Ci: 43 nF
1)
Internal inductance: Li: 10 µH
2)
Temperature class
Standard version T4: –40 < Tamb < 85 °C
T5: –40 < Tamb < 74 °C,
Cable version T5: –25 < Tamb < 70 °C
1
3
4/2
+
-
NO/NC
Function M12-A
4-pin
+ Vs 1
GND (0V) 3
NO/NC 4/2
PNP output: PROFSI3-B25100-ALG-LS
NPN output: Zener barrier
1)
For cable version LBFS-x2xxx.x add 0.17 nF/meter to Ci for cable lengths above 5 meter.
For hanging version LBFS-xx52x.x add 0.20 nF/meter to Ci for cable lengths above 1.5 meter.
2)
For cable version LBFS-x2xxx.x add 0.27 µH/meter to Li for cable lengths above 5 meter.
For hanging version LBFS-xx52x.x add 1.13 µH/meter to Li for cable lengths above 1.5 meter.
8.2 Explosive dust atmospheres zones 20, 21 and 22
The LBFS can be used in explosion hazard areas of zone 20, 21 and 22.
Approval for LBFS-2xxxx.x: ATEX II 1D Ex ta IIIC T100 °C Da
LBFS-2xxxx.x: ATEX II 1 D Ex ta IIIC T100 °C Da
f
Use insulated cable to IP67.
f
Secure cables with external strain relief at a
distance 5 centimeters from the sensor.
f
Comply with the following temperatures,
connection values and circuit diagram.
Supply range Un: 30 V DC max.
In: 100 mA max.
Temperature class T100 °C:
Standard version 40 < Tamb < 85 °C
Cable version –25 < Tamb < 70 °C
Surface temperature 100 °C max.
Protection class for cable
accessories
IP67
10 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
1
3
4/2
+
-
NO/NC
Function M12-A
4 pin
+ Vs 1
GND (0V) 3
NO/NC 4/2
8.3 Explosive gas atmospheres zone 2
The LBFS can be used in explosion hazard areas of zone 2.
Approval for LBFS-3xxxx.x: ATEX II 3G Ex nA IIC T4/T5
LBFS-3xxxx.x: ATEX II 3 G Ex nA IIC T4/T5
f
Comply with the following temperatures,
connection values and circuit diagram
Supply range Un: 30 V DC max.
In: 100 mA max.
Temperature class
Standard version T4: –40 < Tamb < 85 °C
T5: –40 < Tamb < 74 °C
Cable version T5: –25 < Tamb < 70 °C
1
3
4/2
+
-
NO/NC
Function M12-A
4 pin
+ Vs 1
GND (0V) 3
NO/NC 4/2
www.baumer.com
11 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
9. Conguration
The sensor can be congured with the
FlexProgrammer. This allows switching points
and damping values to be selected as required. In
addition pulse width modulation can be specied
for the signal.
Examples for pulse width modulation
U 10%
t
U 50%
t
U 75%
t
Conguring with FlexProgrammer and PC
f
Connect FlexProgrammer to sensor.
f
Connect FlexProgrammer to PC and set
parameters (see FlexProgrammer instructions).
Copying conguration with FlexProgrammer
f
Copy the conguration of one sensor to
another sensor using FlexProgrammer (see
FlexProgrammer instructions)
1
2
10. Operation
Standard operation with factory settings LED indication for “Power-On”
BU
BU = blue: Switched output, active
LED does not light up: Switched output, inactive
BU GN
BU = blue: Switched output, active
GN = green: Switched output, inactive
A green LED can be activated indicating „Power-
On“ by using the FlexProgrammer.
Application-specic settings: see chapter 15. Factory settings and user settings” on page 16.
12 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
11. Cleaning, maintenance and repair
Cleaning
f
Clean, disinfect or sterilize sensor as needed
(CIP/SIP).
Maintenance
Regular maintenance is not required.
Repair
Do not repair the sensor yourself.
f
Send damaged sensor to Baumer.
12. Disposal
f
Do not dispose of in household waste.
f
Separate materials and dispose of in
compliance with nationally applicable
regulations.
13. Accessories
For adapter and other accessories see www.baumer.com.
14. Technical data
Environmental conditions Output signal
Operating temperature range
40…+85 °C Output type
PNP
NPN
Storage temperature range
40…+85 °C
Ambient humidity
< 98 % RH,
condensing
Current load
20 mA max.
Short circuit
protection
yes
Protection class
IP67
IP69K (with
appropriate cable)
Voltage drop
PNP: (+Vs –1.5 V) ± 0.5 V,
Rload = 10 kΩ
NPN: (+1.5 V) ± 0.5 V,
Rload = 10 kΩ
Oscillations (sinusoidal)
(EN 60068-2-6)
1.6 mm p-p
(2…25 Hz),
4 g (25…100 Hz),
1 octave / min.
Leakage current
± 100 μA max.
Switching logic
Normally open (NO),
active low
Normally closed (NC),
high enabled
Power supply
Voltage supply range
12…30 V DC
Reverse polarity protection
yes
Current consumption
(without load)
25 mA typ.,
50 mA max.
Cable version
Operating tempera-
ture range
–25…+70 °C (if cable is not
moved)
5…+70 °C (if cable is
moved)
Power-up time
< 2 s
Features
Repeatability
± 1 mm
Hysteresis
± 1 mm Bending radius min.
r ≥ 10 mm
Response time
0.1 s
Damping
0.0…10.0 s
(congurable)
www.baumer.com
13 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
Process conditions for ambient temperatures < 50 °C
Type Process connection BCID Process
temperature
continuous
[°C]
Process
pressure
[bar]
Process
tempera-
ture
t < 1 h
[°C]
Process
pressure
t < 1 h
[bar]
T
amb < 50 °C Tamb < 50 °C
LBFS-xx1xx.x G 1/2 A ISO 228-1 BSC G07 - 40…115 -1…10 0 135 -1…100
LBFS-xxGxx.x G 1/2 A ISO 228-1 BSC
with cooling neck
1)
G07 - 40…15 0 -1…10 0 N/A N/A
LBFS-xxAxx.x G 1/2 A DIN 3852-E,
NBR seal
G51 - 40…115 -1…10 0 135 -1…100
LBFS-xxBxx.x G 1/2 A DIN 3852-E,
FKM (Viton®) seal
G51 - 40…115 -1…10 0 135 -1…100
LBFS-xx4xx.x G1/2 A hygienic A03 - 40…115 -1…10 135 -1…5
LBFS-xxKxx.x G1/2 A hygienic, length
82 mm
A03 - 40…115 -1…100 135 -1…10 0
LBFS-xxLx.x G1/2 A hygienic,
adjustable connection
A03 -40…200 -1…5 N/A N/A
LBFS-xx5xx.x G 1/2 A ISO 228-1
for internal installation
T10 -40…85 -1…10 0 N/A N/A
LBFS-xx2xx.x G 3/4 A ISO 228-1 G10 - 40…115 -1…100 135 -1…100
LBFS-xx3xx.x G 1 A ISO 228-1 G11 - 40…115 -1…10 0 135 -1…100
LBFS-xxNxx.x 1/2-14 NPT N02 - 40…115 -1…100 135 -1…10 0
LBFS-xxMxx.x 1/2-14 NPT with cooling
neck
N02 - 40…150 -1…10 0 N/A N/A
LBFS-xx6xx.x 3/4-14 NPT N03 - 40…115 -1…10 0 135 -1…100
LBFS-xx7xx.x M18x1 ISO 965 M11 - 4 0…115 N/A N/A N/A
LBFS-xxExx.x
G 1/2 A DIN 3852-E,
FKM (Viton®) seal,
with cooling neck
G51 - 40…15 0 -1…10 0 N/A N/A
1)
Not applicable for mounting with ZPW1-7x1
The temperature specications apply to a maximum dip depth of the sensor tip into the process area of
20 mm.
14 / 48
www.baumer.com
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
Process conditions as a function of the ambient temperature
Type 1, 2, 3, 4, 6, 7, A, B, E, G, K, M, N
80
90
100
110
120
130
140
150
160
50 60 70 80 90
Tp max. (°C)
Tamb (°C)
1
2
1 without cooling neck
2 with cooling neck (version E, G, M)
Tamb Ambient temperature
Tp Process temperature
Version L (adjustable connection)
200 25 35 50 65 90 145
190 20 35 45 65 90 140
180 20 30 45 60 85 140
170 20 25 40 55 85 135
160 25 35 55 80 130
150 20 25 50 75 130
140 20 30 45 75 125
130 25 45 70 120
120 20 40 65 115
110 20 25 60 110
100 30 55 105
90 25 50 100
80 20 45 95
70 35 85
60 35 65
35 40 45 50 55 60 65
Lp (mm)
Tp max. (°C)
Tamb (°C)
1
1 Range without restrictions
Tamb Ambient temperature
Tp Process temperature
Lp min. projecting length:
Lp 15…228
15
15
≤ 228
34
34≥ 15
Lp min. projecting length:
www.baumer.com
15 / 48
Operating Instructions
Level measurement
CleverLevel
®
LBFS
Point level detection
15. Factory settings and user settings
Sensor parameter Factory setting User setting
SW1
(NO)
Switch window,
min.
0%
Switch window,
max.
75.3%
Switch window
hysteresis
2.4%
Damping
0.1 s
16 / 48
www.baumer.com
Inhaltsverzeichnis
Inhaltsverzeichnis ................................................17
1. Sicherheit ...................................................17
2. Aufbau und Funktion ..................................17
3. Symbole in Warnhinweisen ....................... 18
4. Transport und Lagerung ............................ 18
5. Montage .................................................... 18
6. Zulassungen .............................................. 22
7. Elektrischer Anschluss .............................. 23
8. Elektrischer Anschluss in
explosionsgefährdeten Bereichen ............. 23
9. Konguration ............................................. 26
10. Betrieb ....................................................... 26
11. Reinigung, Wartung und Reparatur ........... 27
12. Entsorgung ................................................ 27
13. Zubehör ..................................................... 27
14. Technische Daten ...................................... 27
15. Werkseinstellungen und
Benutzereinstellungen ............................... 30
1. Sicherheit
Bestimmungsgemässe Verwendung
Der Sensor darf ausschliesslich zur
Füllstandserkennung von Flüssigkeiten und
Feststoffen mit einer Dielektrizitätskonstante von
mindestens 1,5 verwendet werden.
Der Sensor darf nur für Medien eingesetzt
werden, gegen die das Gehäusematerial und die
Sensorspitze resistent sind.
Personalqualikation
Nur Personal einsetzen, das für die beschriebenen
Tätigkeiten geschult ist. Dies gilt insbesondere
für Montage, Installation und Explosionsschutz.
Sicherstellen, dass das Personal diese Anleitung
gelesen und verstanden hat.
Technischer Zustand
Sensor nur in einwandfreiem technischen Zustand
verwenden. Nur Zubehör von Baumer verwenden.
Für Zubehör anderer Hersteller übernimmt Baumer
keine Haftung.
Verbrennungsgefahr bei heissen Medien
Das Gehäuse des Sensors kann sich im Betrieb
auf über 50 °C errmen. Bei heissen Medien für
Verbrennungsschutz sorgen.
Explosionsgefährdeter Bereich
Sicherstellen, dass sicherheitstechnische Auagen
eingehalten werden. Geräte, die harten Stössen
ausgesetzt wurden, nicht verwenden.
2. Aufbau und Funktion
1 2 3
Abb. 1. Aufbau
f
L
C
µC
Abb. 2. Funktion
1 Sensorspitze
2 LED
3 Anschluss mit Stecker M12-A, 4-Pin oder
Kabelabgang
Eine in die Sensorspitze integrierte Elektrode
bildet zusammen mit der Umgebung einen
Kondensator. Das Medium bestimmt abhängig
von seiner Dielektrizitätskonstanten (DK-Wert)
den Kapazitätswert. Zusammen mit einer Spule in
der Sensorelektronik entsteht ein Resonanzkreis.
Abhängig von der gemessenen Resonanzfrequenz
und den programmierbaren Triggerschwellen wird
das Schaltsignal angesteuert.
www.baumer.com
17 / 48
Füllstandsmessung
CleverLevel
®
LBFS
Grenzstandsdetektion
Betriebsanleitung
3. Symbole in Warnhinweisen
Symbol Warnwort Erklärung
GEFAHR
Bei Situationen, die zum Tod oder zu schweren Verletzungen führen.
WARNUNG
Bei Situationen, die zum Tod oder zu schweren Verletzungen führen können.
VORSICHT
Bei Situationen, die zu leichten oder mittel schweren Verletzungen führen
können.
ACHTUNG
Bei Sachschäden
4. Transport und Lagerung
f
Verpackung und Sensor auf Beschädigungen
prüfen.
f
Bei Beschädigung: Sensor nicht verwenden.
f
Sensor stosssicher lagern.
Lagertemperatur: –40…+85 °C
Relative Luftfeuchtigkeit: < 98 %
5. Montage
2
4
1
3
4
4
Abb. 3. Generelle Einbaumöglichkeiten
1 Überfüllsicherung
2 Grenzstand max.
3 Grenzstand min.
4 Trockenlaufschutz
Der Sensor kann in jeder beliebigen Lage am
Behälter montiert werden.
Ein oben am Behälter montierter Sensor (1) sichert
gegen Überfüllung. Weiter unten angebrachte
Sensoren erkennen einen maximalen (2) oder
minimalen (3) Grenzstand. Ein unten oder am
Auslaufrohr angebrachter Sensor (4) kann eine
Pumpe vor Trockenlauf schützen.
18 / 48
www.baumer.com
Füllstandsmessung
CleverLevel
®
LBFS
Grenzstandsdetektion
Betriebsanleitung
1
2
3
Abb. 4. Einbau verlängerter Sensoren
1 Grenzstand: Einbau mit Rohr (Version 5)
2 Überfüllsicherung (Version K, L)
3 Pastöse oder pulverförmige Medien
Grenzstand (Version K, L)
Eintauchlänge:
Version K: 82 mm (x)
Version L: 15…228 mm (verschiebbar)
Mit der verschiebbaren Version L kann eine
Tankisolierung überbrückt werden.
Bei pastösen oder pulverförmigen Medien wird
der Sensor durch eine grössere Eintauchtiefe
unempndlicher gegen Anbackungen.
5.1 Montage bei Industrieanwendungen
GEFAHR
Verletzungsgefahr durch gefährliches Medium
f
Bei gefährlichen Medien (z. B. Säuren, Laugen) Schutzausrüstung tragen.
f
Behälter und Rohrleitungen vor der Montage leeren.
PTFE
1
2
LBFS mit folgenden Prozessanschlüssen:
G 1/2 A ISO 228-1 BSC (BCID G07)
G 3/4 A ISO 228-1 (BCID G10)
G 1 A ISO 228-1 (BCID G11)
1/2-14 NPT (BCID N02)
3/4-14 NPT (BCID N03)
9 Behälter und Rohrleitungen sind medienfrei.
f
Gewinde am Sensor mit Teonband (PTFE)
abdichten.
f
Sensor einschrauben.
Anzugsmoment G xx A: 30 Nm max.
Anzugsmoment xx-14 NPT: 20 Nm max.
www.baumer.com
19 / 48
Füllstandsmessung
CleverLevel
®
LBFS
Grenzstandsdetektion
Betriebsanleitung
LBFS mit folgenden Prozessanschlüssen:
G 1/2 A ISO 228-1 BSC (BCID G07)
mit industrieller Einschweissmuffe für
Universaleinsatz Ø 30 x 26 (ZPW1-711,
ZPW1-721)
G 1/2 A hygienegerecht (BCID A03) mit
Einschweissmuffe oder Adapter von Baumer
Bei diesen Prozessanschlüssen wird nicht mit
Teonband (PTFE) oder Elastomer abgedichtet.
9 Behälter und Rohrleitungen sind medienfrei.
9 Adapter oder Einschweissmuffe sind totraumfrei
montiert.
f
Sensor einschrauben.
Anzugsmoment: 15…20 Nm
1
2
LBFS mit folgenden Prozessanschlüssen:
G 1/2 A DIN 3852-E (BCID G51)
9 Behälter und Rohrleitungen sind medienfrei.
f
Dichtring aufschieben.
f
Sensor einschrauben.
Anzugsmoment: 15…20 Nm
1
2
LBFS mit folgenden Prozessanschlüssen:
G 1/2 A ISO 228-1 für Innenmontage (BCID T10)
9 Behälter und Rohrleitungen sind medienfrei.
f
Dichtring aufschieben.
f
Sensor einschrauben.
Anzugsmoment: 15…20 Nm
20 / 48
www.baumer.com
Füllstandsmessung
CleverLevel
®
LBFS
Grenzstandsdetektion
Betriebsanleitung
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Baumer LBFS Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues