LG ARNU183VJA2.ANWALUS Le manuel du propriétaire

Catégorie
Climatiseurs mobiles
Taper
Le manuel du propriétaire

Ce manuel convient également à

P/NO : MFL42803023
www.lg.com
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : Ceiling Suspended
ENGLISH
FRANÇAIS
ESPAÑOL
2 Indoor Unit
Ceiling Suspended Type Indoor Unit Ownerʼs Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
The air conditioner is not intended for use by young
children or invalids without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
Safety Precautions.................3
Prior to Operation ..................8
Operating Instructions...........9
Maintenance and Service ....12
Before you Call for Service
............................................14
ENGLISH
Safety Precautions
Ownerʼs Manual 3
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.
• There is risk of fire or electric
shock.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• Do not disassemble or repair
the product. There is risk of fire
or electric shock.
Always ground the product.
• There is risk of fire or electric
shock.
Install the panel and the
cover of control box
securely.
• There is risk of fire or electric
shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or installation
may cause fire or electric shock
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
Safety Precautions
4 Indoor Unit
Operation
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
Do not install, remove, or
re-install the unit by
yourself (customer).
• There is risk of fire, electric
shock, explosion, or injury.
Be cautious when
unpacking and installing
the product.
• Sharp edges could cause injury.
Be especially careful of the
case edges and the fins on the
condenser and evaporator.
For installation, always contact the
dealer or an Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the product on
a defective installation stand.
• It may cause injury, accident, or
damage to the product.
Be sure the installation area
does not deteriorate with age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.
Do not plug or unplug the
power supply plug during
operation.
• There is risk of fire or electric
shock.
Do not touch(operate) the
product with wet hands.
• There is risk of fire or electrical
shock.
Do not place a heater or
other appliances near the
power cable.
• There is risk of fire and electric
shock.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open
.
• Moisture may condense and
wet or damage furniture.
Take care to ensure that power
cable could not be pulled out
or damaged during operation.
• There is risk of fire or electric
shock.
Do not place anything on
the power cable.
• There is risk of fire or electric
shock.
ENGLISH
Do not allow water to run
into electric parts.
• It may cause There is risk of
fire, failure of the product, or
electric shock.
Do not store or use flammable
gas or combustibles near the
product.
• There is risk of fire or failure of
product.
Do not use the product in a
tightly closed space for a
long time.
• Oxygen deficiency could occur.
When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turn the product on.
• Do not use the telephone or
turn switches on or off.
There is risk of explosion or fire
If strange sounds, or small or
smoke comes from product. Turn
the breaker off or disconnect the
power supply cable.
• There is risk of electric shock or
fire.
Stop operation and close the window
in storm or hurricane. If possible,
remove the product from the window
before the hurricane arrives.
• There is risk of property
damage, failure of product, or
electric shock.
Do not open the inlet grill of the
product during operation.
(Do not touch the electrostatic
filter, if the unit is so equipped.)
• There is risk of physical injury,
electric shock, or product
failure.
When the product is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of fire or electric
shock.
Be cautious that water
could not enter the product.
• There is risk of fire, electric
shock, or product damage.
G
asolin
Ventilate the product from time to time
when operating it together with a stove, etc.
• There is risk of fire or electric shock.
Turn the main power off when cleaning or
maintaining the product.
• There is risk of electric shock.
Safety Precautions
Ownerʼs Manual 5
Safety Precautions
6 Indoor Unit
Installation
CAUTION
Operation
Always check for gas
(refrigerant) leakage after
installation or repair of product.
• Low refrigerant levels may
cause failure of product.
Install the drain hose to ensure
that water is drained away
properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
Do not install the product where the
noise or hot air from the outdoor unit
could damage the neighborhoods.
• It may cause a problem for your
neighbors.
Use two or more people to lift
and transport the product.
• Avoid personal injury.
Do not install the product
where it will be exposed to
sea wind (salt spray) directly.
It may cause corrosion on the product.
Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation
.
90
When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody could step
on or fall onto the outdoor unit.
• This could result in personal injury and product
damage.
Do not expose the skin directly to cool air
for long periods of time.
(Don't sit in the draft.)
• This could harm
to your health.
Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer
air conditioner, not a precision refrigeration system.
• There is risk of
damage or
loss of property.
Do not recharge or
disassemble the batteries.
Do not dispose of batteries
in a fire.
• They may burn or explode.
If the liquid from the batteries gets
onto your skin or clothes, wash it
well with clean water. Do not use the
remote if the batteries have leaked.
The chemicals in batteries could
cause burns or other health hazards.
If you eat the liquid from the
batteries, brush your teeth and see
doctor. Do not use the remote if the
batteries have leaked.
• The chemicals in batteries could cause
burns or other health hazards.
ENGLISH
Safety Precautions
Ownerʼs Manual 7
Do not block the inlet or
outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.
• There is risk of fire, electric
shock, or damage to the plastic
parts of the product.
Do not touch the metal parts of
the product when removing the
air filter. They are very sharp!
• There is risk of personal injury.
Wax
Thinner
Do not step on or put
anyting on the product.
(outdoor units)
• There is risk of personal injury
and failure of product.
Always insert the filter
securely. Clean the filter
every two weeks or more
often if necessary.
A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
Do not insert hands or other
objects through the air inlet
or outlet while the product
is operated.
• There are sharp and moving
parts that could cause personal
injury.
Do not drink the water
drained from the product.
• It is not sanitary and could
cause serious health issues.
Use a firm stool or ladder
when cleaning or
maintaining the product.
• Be careful and avoid personal
injury.
Replace the all batteries in the
remote control with new ones
of the same type. Do not mix
old and new batteries or
different types of batteries.
• There is risk of fire or explosion
Prior to operation
8 Indoor Unit
Prior to Operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision
devices, food, pets, plants, and art objects). Such usage could damage the items.
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unitʼs power is
accidentally triggered on while cleaning inner parts of the unit.
For repair and maintenance, contact your authorized service dealer.
Preparing for operation
Usage
Cleaning and maintenance
Service
Operating Instructions
Ownerʼs Manual 9
ENGLISH
Operating Instructions
1
4
5
7
11
10
9
8
2
3
6
13
12
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
14
15
Name and function of wired remote controller(Accessory)
※ Some functions may not be operated and displayed depending on the product type.
※ It will display strange value to the room temperature if wired remote controller is not connected.
Model : PQRCVSL0 (Black Color)
PQRCVSL0QW (White Color)
1. Operation indication screen
2. Set temperature button
It will set not room temperature but outlet air temperature.
3. Fan speed button
• Fan Speed have 3 Steps.
• Middle and Low step is same
4. ON/OFF button
5. Opration mode selection button
6. Wireless remote controller receiver
• Some products don't receive the wireless signals.
7. Air flow button
8. Subfunction button
9. Function setting button
10. Ventilation button
11. Reservation
12. Up,down,left,right button
To check the indoor temperature, press button.
13. Room temperature button
• Displays only the room temperature of the remote
controller perception.
• There is no control of room temperature.
• In case of fresh air intake unit, displays only the
temperature around remote controller.
14. Setting/Cancel button
15. Exit button
Operating Instructions
10 Indoor Unit
Wireless Remote Controller
(Optional)
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
Cooling Model( ), Heat Pump Model( )
Operation Mode
PQWRCDF0 (Heat pump)
PQWRHDF0 (Cooling only)
13
14
15
16
1
8
9
10
11
12
2
3
4
5
6
7
1. Plasma button (Optional)
Used to start or stop the plasma-purification
function.
2. Jet cool button
Speed cooling operates super high fan speed.
3. Operation mode selection button
Used to select the operation mode.
4. Function setting button
Used to set or clear auto clean or smart clean.
5. LCD luminosity button (Optional)
Used to adjust LCD luminosity
6. Smart clean button (Optional)
Used to start or stop smart clean.
7. Clear all button
Used to clear all timer.
8. Room temperature setting button
Used to select the room temperature.
9. ON/OFF button
Used to turn off/on the unit.
10. Indoor fan speed selection button
Used to select fan speed in four steps low,
medium, high and chaos.
11. Auto swing button
Used to stop or start louver movement and set the
desired up/down airflow direction.
12. Horizontal airflow direction control button
(Optional)
Used to set the desired horizontal airflow direction.
13. Timer and time setting button
Used to set the time of starting or stopping and
sleeping operation.
14. Room temperature checking button
Used to check the room temperature.
15. °C/°F switch button
Used to switch temperature reading from Celsius
to Fahrenheit.
16. Reset button
Used to reset the remote controller.
Operating Instructions
Ownerʼs Manual 11
ENGLISH
Forced operation�
(Tact switch)
Forced Operation
Auto Restart Function
Tips for Filter sign LED
Operation procedures when the remote control can't be used.
Press the tact switch (Forced operation) for 2 seconds.
If you want to stop operation, press again the tact switch.
In case the power comes on again after power failure on the Forced
Operation mode, the operating conditions are automatically set as
follows:
During Forced Operation, the initial mode continues.
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
1. Filter sign lamp (LED) is ON.
2. If LED indicating filter sign lamp is ON, clean the filter.
3. After cleaning the filter, press the Timer button and button of wired remote controller at the same time for 3 sec.
Then filter sign LED is OFF.
Heat pump Model
Cooling Model
Room Temp. ≥ set Temp.4 °F(2°C) Room Temp. < set Temp.4 °F(2°C)
Operating mode Cooling Cooling Heating
Indoor FAN Speed High set available set available
Setting Temperature 72 °F(22°C) set available set available
Maintenance and Service
12 Indoor Unit
B
e
n
z
e
n
e
S
C
O
U
R
I
N
G
C
L
B
A
R
G
E
R
S
I
N
N
E
R
Horizontal louver
Vertical louver
Air outlet vent
Air filters�
(Behind inlet grille)
Air inlet vent�
(Inlet grille)
Maintenance and Service
Grille, Case, and Remote Control
Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
Supply power must be disconnected before
cleaning the indoor unit.
NOTICE
1. Remove the Air filters.
Take hold of the tab and pull slightly forward
to remove the filter.
CAUTION:
When the air filter is
to be removed, do not touch the
metal parts of the indoor unit.
It may cause an injury.
2. Clean dirt from the air filter using a vacuum
cleaner or washing with water.
If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
If hot water (50°C or more) is used, it may be
deformed.
3. After washing with water, dry well in
the shade.
Do not expose the air filter to direct
sunlight or heat from a fire when drying
it.
4. Install the air filter.
Air Filters
The air filters behind the front grille should be checked and
cleaned once every 2 weeks or more often if neccessary.
CAUTION: Before performing any maintenance, turn off the main power to
the system.
Never use any of the followings:
Water hotter than 40°C.
Could cause deformation and/or discoloration.
Volatile substances.
Could damage the
surfaces of the air
conditioner.
ENGLISH
Maintenance and Service
Ownerʼs Manual 13
When the air conditioner is not going to be used for a long time.
Operation Tips
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the electricity
used to operate the air conditioner will be wasted.
When it is not going to be used for
a long time.
When the air conditioner is to be used again.
Operate the air conditioner at the
following settings for 2 to 3 hours.
• Type of operation: Fan operation mode.
• This will dry out the internal mechanisms.
Turn off the breaker.
Turn off the breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Clean the air filter and install it in the
indoor unit.
(Refer to page 12 for cleaning it.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Check that the ground wire is
connected correctly. It may be connect
to the indoor unit side.
Do not overcool the room.
This is not good for the health
and wastes electricity.
Keep blinds or curtains
closed.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature
in the room.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and
windows as much as possible
to keep the cool air in the
room.
Clean the air filter regularly.
Blockages in the air filter
reduce the airflow and lower
cooling and dehumidifying
effects. Clean at least once
every two weeks.
Ventilate the room
occasionally.
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
Maintenance and Service
14 Indoor Unit
Before you call for service...
?
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
Troubleshooting Tips! Save time and money!
• Have you made a
mistake in timer
operation?
• Has the fuse blown
or has the circuit
breaker been
tripped?
• Check that this is not
a damp smell exuded
by the walls, carpet,
furniture or cloth
items in the room.
• Condensation occurs
when the airflow from
the air conditioner
cools the warm room
air.
• This is the protector
of the mechanism.
• Wait about three
minutes and
operation will begin.
The air conditioner
does not operate.
The room has a
peculiar odor.
It seems that
condensation is
leaking from the air
conditioner.
Air conditioner does
not operate for about
3 minutes when
restart.
Does not cool or heat
effectively.
The air conditioner
operation is noisy.
Crack sound is
heard.
Remote control
display is faint, or no
display at all.
• Is the air filter dirty?
See air filter cleaning
instructions.
• The room may have
been very hot when
the room air
conditioner was first
turned on. Allow time
for it to cool down.
• Has the temperature
been set incorrectly?
• Are the indoor unit's
air inlet or outlet vents
obstructed?
• For a noise that
sounds like water
flowing.
-This is the sound of
freon flowing inside
the air conditioner
unit.
• For a noise that
sounds like the
compressed air
releasing into
atmosphere.
-This is the sound of
the dehumidifying
water being
processed inside the
air conditioning unit.
• This sound is generated
by the expansion/
constriction of the front
panel, etc. due to
changes of
temperature.
• Cleaning the filter,
press the Timer button
and button of wired
remote controller at
the same time for 3
sec.
• Are the batteries
depleted?
• Are the batteries
inserted in the
opposite (+) and (-)
directions? 
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to
excess water.
NOTICE
Filter sign lamp
(LED) is ON.
www.lg.com
MODE D’EMPLOI
CLIMATISEUR
Veuillez lire attentivement ce manuel avant d’utiliser votre
appareil, et le conserver pour toute consultation ultérieure.
TYPE : Suspendu au plafond
FRANÇAIS
2 Unité Interieure
Suspendu au plafond-Manuel d'utilisation
TABLE DES MATIÈRES
POUR VOS ARCHIVES
Écrivez les numéros de modèle et de série ici :
Modèle #
Série #
Vous les trouverez sur la plaque signalétique située sur
le côté de chaque unité.
Nom du Distributeur:
Date dʼachat
Agrafez votre reçu à cette page au cas où vous en auriez
besoin pour démontrer la date d'achat du produit ou pour
avoir droit à la garantie.
LISEZ CE MANUEL
Vous trouverez à lʼintérieur de ce manuel beaucoup de
conseils utiles sur la façon dʼutiliser et dʼentretenir
correctement votre climatiseur. Quelques petites
mesures préventives vous permettront dʼépargner
beaucoup de temps et dʼargent pendant la durée de vie
de votre climatiseur. Vous trouverez beaucoup de
réponses aux problèmes les plus fréquents dans le
tableau du guide de dépannage. Si vous passez en
revue notre Guide de Dépannage d'abord, il se peut que
vous nʼayez pas du tout besoin dʼappeler le Service
Après-Vente.
PRÉCAUTION
• Contactez le service technique agréé pour la réparation ou
l'entretien de cette unité.
• Contactez un technicien autorisé pour l'installation de cette unité.
• Le climatiseur ne doit pas être actionné par des petits enfants ou
par des personnes infirmes sans surveillance.
• Veillez toujours à surveiller les petits enfants pour éviter quʼils
jouent avec l'appareil.
• Si le cordon dʼalimentation doit être remplacé, ce travail ne doit
être accompli que par du personnel autorisé utilisant uniquement
des pièces de rechange authentiques.
• Conformément aux standards nationaux sur le câblage,
lʼinstallation ne doit être effectuée que par du personnel qualifié
et autorisé.
Mesures de sécurité...............3
Avant de le faire fonctionner
....8
Instructions de
fonctionnement. .....................9
Entretien et Service..............12
Avant d'appeler le service
Technique...........................14
Mesures de sécurité
Manuel d'utilisation 3
FRANÇAIS
Les instructions ci-après doivent être observées dans le but de prévenir tout risque de
dommages corporels ou matériels.
L'utilisation non conforme, résultant de la négligence des instructions, est susceptible de
provoquer des dommages corporels ou matériels dont la gravité est signalée par les
Les significations des symboles utilisés dans ce manuel sont indiquées ci-dessous.
ATTENTION
PRECAUTION
Ce symbole indique un risque de blessure grave, voire mortelle.
Ce symbole indique un risque de blessure ou des
dommages matériels seulement.
Veillez à ne pas faire cela.
Veillez à suivre les instructions de ce manuel.
ATTENTION
Installation
N'utilisez pas un coupe-circuit
défectueux ou à valeur
nominale insuffisante. Utilisez
cet appareil sur un circuit dédié.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Pour un travail électrique, contactez
le distributeur, le vendeur, un
électricien qualifié ou un Centre de
Service Après Vente Agrée.
• Ne démontez ni réparez le produit.
Ceci risquerait de provoquer un
incendie ou un choc électrique.
Faites toujours une
connexion reliée à la terre.
• Autrement vous risquez de
provoquer un incendie ou un
choc électrique.
Installez fermement le
panneau et le couvercle du
tableau de commande.
Autrement vous risquez de
provoquer un incendie ou un choc
électrique.
Installez toujours un circuit
et un disjoncteur dédiés.
• Un câblage ou une installation
inappropriés peuvent provoquer
un incendie ou un choc
électrique.
Utilisez un disjoncteur ou
fusible à valeur nominale
appropriée.
• Autrement vous risquez de
provoquer un incendie ou un
choc électrique.
Mesures de sécurité
Mesures de sécurité
4 Unité Interieure
Fonctionnement
Ne modifiez ni prolongez le
cordon d'alimentation.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
N'installez pas, n'enlevez pas, ne
remettez pas en place l'unité
vousmême (si vous êtes un utilisateur).
• Vous pourriez provoquer un
incendie, un choc électrique, une
explosion ou vous blesser.
Prenez soin lorsque vous
déballez et installez ce
produit.
Les bords aiguisés peuvent provoquer
des blessures. Faites attention en
particulier aux bords du boîtier et aux
ailettes du condenseur et de
l'évaporateur.
Contactez toujours le revendeur ou un
centre de service après vente agréé
pour effectuer l'installation.
• Autrement, vous pourriez
provoquer un incendie, un choc
électrique, une explosion ou
vous blesser.
N'installez pas le produit sur
un support d'installation
défectueux.
• Ceci peut provoquer des
blessures, un accident ou bien
endommager le produit.
Vérifiez que la zone
d'installation n'est pas abîmée
par le temps.
Si la base s'écroule, le climatiseur
pourrait tomber avec elle, provoquant
des dommages matériels, une
défaillance du produit et des blessures.
Ne branchez ni débranchez
la fiche d'alimentation en
cours de fonctionnement.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Ne touchez pas (ne faites
pas fonctionner)le produit
avec les mains humides.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Ne placez pas de radiateurs
ou d'autres appareils près
du cordon d'alimentation.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Ne laissez pas le climatiseur marcher trop
longtemps lorsque l'humidité est très élevée et
qu'il y a une porte ou une fenêtre ouverte.
• De l'humidité peut se condenser
et innonder ou endommager le
mobilier.
Assurez-vous qu'on ne puisse pas
tirer des câbles ou les endommager
en cours de fonctionnement.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Ne placez aucun objet sur le
cordon d'alimentation.
• Ceci risquerait de provoquer un
incendie ou un choc électrique.
Mesures de sécurité
Manuel d'utilisation 5
FRANÇAIS
Veillez à ne pas faire couler
d'eau sur les parties
électrique.
• Ceci pourrait provoquer un
incendie, une défaillance de
l'appareil ou un choc électrique.
N'emmagasinez ni utilisez de
substances inflammables ou
combustibles près de ce produit
.
• Ceci entraînerait un risque
d'incendie ou de défaillance du
produit.
N'utilisez pas ce produit dans un
espace fermé hermétiquement pendant
une longue période de temps.
• Il peut se produire un manque
d'oxygène.
S'il y a une fuite de gaz inflammable,
fermez le robinet à gaz et ouvrez une
fenêtre pour ventiler la pièce avant
de mettre en marche le climatiseur.
• N'utilisez pas le téléphone ni déplacez les
interrupteurs sur les positions marche/arrêt.
Ceci risquerait de provoquer une explosion
ou un incendie.
Si le climatiseur dégage des sons, des
odeurs ou de la fumée, mettez le
disjoncteur sur la position arrêt (off) ou
débranchez le cordon d'alimentation.
• Il y a risque de choc électrique ou
d'incendie.
Arrêtez le climatiseur et fermez la fenêtre
en cas de tempête ou d'ouragan. Si
possible, enlevez le produit de la fenêtre
avant que l'ouragan arrive.
• Il y a risque de dommages à la
propriété, de défaillance du produit
ou de choc électrique.
N'ouvrez pas la grille d'entrée d'air du
produit en cours de fonctionnement.
(Ne touchez pas le filtre électrostatique,
si l'unité en est équipée.)
Autrement, vous risquez de subir des
blessures physiques, un choc
électrique ou de provoquer une
défaillance du produit.
Contactez le centre de
service après vente agréé si
le produit est trempé(rempli
d'eau ou submergé).
• Ceci risque de provoquer un
incendie ou un choc électrique.
Veuillez à ce que l'eau ne
pénètre pas dans le produit.
• Ceci risquerait de provoquer un
incendie, un choc électrique ou
d'endommager le produit.
Gasolin
Ventilez la pièce de temps en temps lorsque
vous l'utilisez simultanément avec une poêle,
etc.
• Autrement, vous risquez de provoquer un incendie ou
un choc électrique.
Arrêtez le climatiseur avant de procéder à des
opérations de nettoyage ou de maintenance
du produit.
• Autrement, vous risquez de provoquer un incendie ou
un choc électrique.
Mesures de sécurité
6 Unité Interieure
Installation
PRECAUTION
Fonctionnement
Vérifiez toujours s'il y a des fuites de
gaz (frigorigène) suite à l'installation
ou réparation du produit.
• Des niveaux de frigorigène trop
bas peuvent provoquer une
défaillance du produit.
Installez le raccord de drainage de
manière à assurer un drainage
approprié.
• Une mauvaise connexion peut
provoquer des fuites d'eau.
Maintenez le produit de niveau
lors de son installation.
• Installation de niveau afin d'éviter
vibrations ou des fuites d'eau.
N'installez pas le produit à un endroit
où le bruit ou l'air chaud dégagés de
l'unité extérieure dérangent les voisins.
• Ceci pourrait entraîner des
problèmes de voisinage.
Faites appel à deux ou plusieurs
personnes pour enlever et
transporter ce produit.
• Evitez des blessures.
N'installez pas ce produit à un endroit
où il serait exposé directement au vent
de la mer (pulvérisation d'eau de mer).
Ceci peut provoquer de la corrosion sur le
produit. La corrosion, particulièrement sur
les ailettes du condenseur et de
l'évaporateur, peut provoquer un
dysfonctionnement ou un fonctionnement
inefficace du produit.
90
Si vous n'utiliser pas le produit pendant une longue
période de temps, débranchez le cordon d'alimentation
ou mettez le disjoncteur sur la position Arrêt (off).
• Autrement, vous risquez d'endommager le produit ou
de provoquer une défaillance de celui-ci ou bien une
mise en marche involontaire.
Assurez-vous que personne ne peut
marcher ou tomber sur l'unité extérieure.
• Ceci pourrait provoquer des blessures personnelles
et des dommages au produit.
N'exposez pas la peau directement sous le jet d'air
froid pendant des longues périodes de temps (Ne
vous asseyez pas sous le courant d'air).
• Ceci peut nuire à votre santé.
N'utilisez pas ce produit pour des objectifs spéciaux tels que la
préservation d'aliments, d'oeuvres d'art, etc. C'est un climatiseur de
confort, pas un système frigorifique de précision.
• Il y a risque de dommage à
la propriété ou pertes
matérielles.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

LG ARNU183VJA2.ANWALUS Le manuel du propriétaire

Catégorie
Climatiseurs mobiles
Taper
Le manuel du propriétaire
Ce manuel convient également à