QUICK INSTALL GUIDE (Model IQPLUS-B1200-LL-I-US00-RV1)
Installing the Enphase IQ Battery
To install the Enphase
IQ Battery™ and the Enphase Wall-Mount Bracket, read and follow all warnings and instructions in this guide and in the Enphase IQ
Battery Installation and Operation Manual at enphase.com/support. Safety warnings are listed on the back of this guide. These instructions are not meant
to be a complete explanation of how to design and install an energy storage system. All installations must comply with national and local electrical codes
and standards. Only qualied electricians shall install, troubleshoot, or replace the IQ Battery.
The Enphase Storage System includes the
Enphase IQ Battery with integrated Enphase
Microinverter™. The system uses the Enphase
IQ Envoy™ to measure PV production and home
energy consumption. The system senses when it
is optimal to charge or discharge the battery so
that energy is stored when it is abundant and used
when scarce.
Enphase Storage System
Microinverters
IQ Envoy
Metered
Load center
Router
Enlighten
To Internet
IQ Batteries
INSTALLATION
Choose a location for the IQ Battery array
The IQ Battery housing is a NEMA type 2 metallic enclosure. The termi-
nal blocks on the wall-mount bracket accept a maximum conductor size
of 12 AWG.
A ) Following local standards, choose a well-ventilated, indoor location
(like a garage), which is out of direct sunlight and where the ambient
temperature and humidity are within -4° F to 113° F (-20° C to 45° C)
and 5% to 95% RH, non-condensing.
B ) Ensure that the mounting location can sustain the weight of the IQ
Battery and mounting bracket (60 lbs per battery).
C ) Plan the mounting location to be at least one foot off the ground
and one foot from the ceiling. Keep the battery(ies) away from
falling or moving objects, including motor vehicles.
* WARNING: If mounted in the direct path of a motor vehicle, we
recommend a 36-inch minimum (91 cm) mounting height.
D ) Ensure that there are no pipes or electrical wires where you plan to
drill.
E ) Plan to maintain at least one foot of clearance in front of each
battery.
F ) Consider the dimensions of the IQ Battery, easy access, height, and
length of cable when selecting the location.
G ) Do not block the vents or allow liquids to contact the IQ Battery. The
IQ Battery is not waterproof.
H ) Select a location where you can interconnect to the sites load center
using an appropriate branch circuit.
I ) Following local standards, decide whether to connect using
external conduit or by wiring inside the walls. This determines which
knockouts to use in the junction box.
J ) If you are installing more than one IQ Battery, continue to maintain
minimum required clearances as shown in Step 2.
1
PREPARATION
A ) Inspect the packaging and the IQ Battery for damage. Do not install or
use the IQ Battery if it has been damaged in any way.
B ) Ensure that you have the following:
One or more Enphase IQ Battery(ies): The IQ Battery shipping box
contains an Enphase IQ Battery and an access panel cover.
NOTE: Check the “Must Energize By” label on the shipping box to
verify that the IQ Battery will be installed by the date shown.
An equal number of Enphase Wall Mount Brackets (BWM-16IN-B):
The wall-mount bracket shipping box includes only the bracket. The
brackets accommodates 16-inch stud-spacing.
C ) Make sure you have the following required items:
Enphase IQ Envoy communications gateway with production CT(s)
and consumption CT(s) installed and congured as described in
the Enphase IQ Envoy Quick Install Guide. The Enphase IQ Battery
requires an Internet connection (through the Envoy). Failure to
maintain an Internet connection may have an impact on the
warranty. See enphase.com/warranty for full terms and services.
Mounting location that is structurally suited to bearing the weight of
the IQ Battery. The wall must have appropriately spaced studs (16
inches) or can be of masonry or other suitable structure.
Tools: conduit (with ttings and tting tools), drill, 5/32 inch pilot
bit, screwdriver, socket, wrench, adjustable wrench, torque wrench,
level, 5/32 inch Allen key, and wire stripper.
Four 1/4 inch diameter lag bolts/screws, 1 to 2 inches long
(depending on attachment wall), for each wall-mount bracket. Check
with a structural engineer and local standards for requirements for
your site.
Washers for use between fastener heads and wall-mount bracket.
12 AWG to 20 AWG
(7/16 inch strip length) copper conductors
(rated at 75° C or 90° C) for push terminals.
Gland or strain relief tting (one for each used conduit opening in
the AC junction box).
20A maximum over current protection in accordance with local
standards.
Personal protective equipment (PPE) for handling lithium ion
batteries as required by local safety standards.
Stud nder.
D ) Install the PV system and the IQ Envoy as directed by the installation
manuals.
E ) To record the location(s) of the IQ Battery(ies), peel the removable
serial number label from each battery and afx it to the respective
location on a paper installation map. You will scan this map later
using Enphase Installer Toolkit™ and your mobile device. You can nd
an example installation map at the back of any Enphase Microinverter
manual.
Install the wall-mount bracket
A ) Make sure that the wall-mount bracket matches the wall stud spacing
and that the lowest wall-mount bracket position meets clearance
requirements as shown.
* WARNING! Risk of injury and equipment damage. Protect the IQ
Battery from impact damage and improper use.
B ) Remove the appropriate knockout(s) for the planned entry into the
wall-mount bracket junction box:
If wiring inside the walls, use the knockout(s) in the back of each
junction box. If using conduit, use the knockouts at the bottom of
the junction box.
If installing only one battery or when installing the last battery in the
array, use only one knockout.
Loosen the screw securing the junction box cover and remove the
cover. Keep the cover handy as you will need it later.
C ) Starting at battery position closest to the power source, mark a level
line on the wall as a guide.
* WARNING! Multiple risks. Make sure not to drill or attach into
electric wiring or pipes that are in the wall!
2
D ) Place the wall-mount bracket on the wall so that the mark on the
bracket aligns with the center of the stud. Use a level to keep the
top of the wall-mount bracket at, and attach each corner of the
wall-mount bracket using one screw and washer for each slot.
E ) Verify that the wall-mount bracket is solidly attached to the wall.
* WARNING! Risk of injury and equipment damage. Do not mount
an IQ Battery on a bracket that is not properly mounted.
F ) If installing additional batteries, install the adjacent wall-mount
brackets in an interleaved fashion, as needed. Be sure to align the
mark on the adjacent wall-mount bracket to the center of the wall
stud. A small overlap in adjacent brackets is normal. You may install
another row of brackets above the one already installed. Maintain at
least one foot clearance between rows.
Dimensions for the 16-inch wall-mount bracket (BWM-16IN-B):
Wire the junction box
A ) Size the conductors (Line, Neutral and Ground) depending on
the upstream breaker or fuse. Use 12 AWG to 20 AWG wire with
maximum 20A branch circuit protection.
+ DANGER! Risk of electric shock. Check that the dedicated
circuit breaker protecting the branch where the IQ Battery will be
connected is turned off before wiring.
* WARNING! Risk of equipment damage. Always connect to two
Lines (active) and to one Neutral.
B ) Using the conductors and suitable conduits, connect the AC
isolator (if used) and the rst adjacent IQ Battery junction box. Use
the openings provided by the knockouts to connect the conduit and
pass the wires through them.
NOTE: Do not modify or rewire the pre-installed wiring or bonding
connections in the junction box.
C ) Connect each wire in the junction box to its corresponding conduc-
tor (Line, Neutral and Ground). Each push terminal accepts two 12
AWG to 20 AWG
conductors (7/16 inch strip length). For each, use
a screw driver to depress and open the terminal, then insert the
stripped conductor.
D ) After all wires in the junction box are connected and secured, check
that there are no exposed conductors.
E ) If connecting additional IQ Batteries, use another conduit and
another set of wires to connect between junction boxes.
F ) Gently arrange all the wires and connectors inside the junction
box and replace the cover. Tighten the cover screw using a Phillips
screw driver.
+
DANGER! Risk of electric shock. The system is not ready to
be energized! Do not close the circuit breaker yet.
4
Mounting
slots
Junction box
Junction box
cover screw
One foot
(minimum)
spacing
Wall-mount brackets
shown interleaved
Mounting
slots
One foot minimum
height from ground
One foot minimum
from ceiling
KEY:
1. Terminal block
2. Ground from previous junction box
3. Ground to next junction box, if needed
4. Neutral from previous junction box
5. Neutral to next junction box, if needed
6. L1 from previous junction box
7. L1 to next junction box, if needed
8. L2 from previous junction box
9. L2 to next junction box, if needed
10. L2 from this junction box, to connector
11. L1 from this junction box, to connector
12. Neutral from this junction box to connector
13. Ground from this junction box, to chassis screw
N
L1
L2
1
2
3
4
5
6
7
8
9
10
11
12
13
16.0 in
14.0 in
19.2 in
35.2 in
Install the AC disconnect, if required
Following all local codes and standards:
A ) Choose an AC disconnect that can break the maximum rated current
of the branch circuit under load (20 A maximum).
B ) Connect one side of the disconnect to the load center.
C ) Verify that AC voltage at the site is within range: single-phase L1 to L2
voltage must measure between 211 and 264 VAC, while L-N should
measure between 106 and 132 VAC.
3
Energize the system
* WARNING: Before energizing, make sure that ALL IQ
Batteries in the system are properly installed and conductors
terminated.
A ) Check that the IQ Battery bottom access plates on all IQ Batteries
in the system are closed and secured.
B ) Turn on the circuit feeding the IQ Battery(ies).
C ) Flip the switch on the AC junction box to the on position.
D ) The IQ Battery LED should now be solid red for the duration of
the startup process. If the LED is not solid red, see the following
section on Troubleshooting.
6
Use the Enphase Installer Toolkit to commission the IQ Battery(ies).
Once connected to the Envoy, refer to the Installer Toolkit help topics
for more information.
After the IQ Envoy has detected the IQ Battery(ies), the IQ Battery LEDs
operate as described in the following section.
CONFIGURE and ACTIVATE
OPERATION
a
LED overview
The LED ashes yellow while the IQ Battery boots up. If the LED rapidly
ashes green for more than two minutes, the battery is in trickle
charge mode and will remain so until it reaches a minimum state of
charge (up to 30 minutes). After the IQ Battery is booted up, the LED
becomes blue or green depending on the charge level. If the LED ash-
es yellow after one hour or changes to a ashing red state, contact
Enphase Customer Support at enphase.com/en-us/support/contact.
State Description
Rapidly ashing yellow Starting up / Establishing communications
Red ashes in sequences of 2 Error. See “Troubleshooting”.
Solid yellow Not operating due to high temperature. See
“Troubleshooting”.
Solid blue or green Idle. Color transitions from blue to green as
state of charge increases. You can check
Enlighten for charge status.
Slowly ashing blue Discharging
Slowly ashing green Charging
Slowly ashing yellow Sleep mode activated
Off Not operating. See “Troubleshooting”.
b
Troubleshooting
If the IQ Battery is not operating correctly, perform the following steps.
If the issue persists, contact Enphase Customer Support at
enphase.com/en-us/support/contact.
A ) If the IQ Battery does not operate, check the temperature in the
room and increase cooling and/or ventilation as required. Check
that the front, top, and sides of the IQ Battery array have at least
one foot of unobstructed clearance.
B ) If the IQ Battery LED is off, turn off the breaker for the branch
circuit, wait for at least one minute, and turn it back on.
NOTE: During a brownout or blackout, the IQ Battery powers down
automatically. This is normal. When power is restored, it automati-
cally starts up again.
C ) If you do not see IQ Battery information in Enlighten, check that
the IQ Envoy and the Internet connection are working.
D ) Refer to the IQ Battery Installation and Operation Manual at
enphase.com/support to read more about troubleshooting IQ
Battery operation.
Mount the IQ Battery on the wall
* WARNING! Risk of injury and equipment damage. Avoid drop-
ping the IQ Battery. Doing so may create a hazard, cause serious
injury, and/or damage the equipment.
* WARNING: Before mounting the Enphase IQ Battery, ensure
that the junction box cover is secured!
* WARNING: Take care when lifting the IQ Battery. The IQ Bat-
tery is heavy and may require two persons to lift.
A ) Using both hands, take the IQ Battery from the packaging and place
it right side up on a at surface. Be sure that the AC connector is not
pinched underneath.
5
B ) Begin by installing the IQ Battery located closest to the main supply.
Using the two grip insets on the side of the IQ Battery, lift and carry
the IQ Battery to the installed wall-mount bracket.
C ) While setting the IQ Battery onto the wall-mount bracket, ensure that
the four tabs on the IQ Battery are inserted into their corresponding
openings in the wall-mount bracket. After the tabs are inserted,
begin lowering the IQ Battery slowly to ensure that the tabs have
latched onto the wall-mount bracket.
* WARNING! Risk of injury and equipment damage. Do not
release the IQ Battery until you ensure that all four tabs have safely
latched onto the wall-mount bracket.
* WARNING! Risk of equipment damage. When placing the IQ
Battery on the wall-mount bracket, ensure that the junction box does
not pinch the DC connector, the AC connector, or its cable.
D ) Use a Phillips #2 screwdriver to secure the two bond screws into the
wall-mount bracket. The bond screws are accessible through the
bottom access compartment. The bond screws provide a grounding
bond between the IQ Battery and the wall-mount bracket.
* WARNING! Always secure the bond screws to ensure a ground-
ing bond and rm mechanical attachment of IQ Battery to wall-
mount bracket.
E ) Plug the DC connector into the DC socket. Listen for a clicking
sound as the connectors engage.
* WARNING! Risk of equipment damage. Do not connect the AC
connector until the DC connector is completely engaged.
NOTE: This action connects the internal battery to the internal elec-
tronics; you must disconnect it if you
move the IQ Battery.
NOTE: Check that the wall-mount
bracket junction box is fully inside the
access compartment of the IQ Battery.
The IQ Battery must not rest on the
junction box or rely on it for support.
F ) Connect the battery AC connector
into the AC connector on the junction
box. Listen for a clicking sound as the
connectors engage.
G ) Attach the bottom access plate and
secure the two compression half-turn
latches using a 5/32-inch Allen key.
DC socket
DC connector
AC connector
Bond screw
Bond screw
Bottom view (access plate removed)
AC
connector
on/off
switch
Enphase Customer Support: enphase.com/en-us/support/contact
Safety and Advisory Symbols
+
DANGER: This indicates a hazardous situation, which if not avoided, will
result in death or serious injury.
*
WARNING: This indicates a situation where failure to follow instructions
may be a safety hazard or cause equipment malfunction. Use extreme
caution and follow instructions carefully.
NOTE: This indicates information particularly important for optimal system
operation. Follow instructions carefully.
Safety Instructions
+
DANGER: Risk of electric shock. Risk of re. Only qualied electricians should
install, troubleshoot, or replace the IQ Battery.
+
DANGER: Risk of re or explosion. Only qualied personnel, using personal
protective equipment (PPE) should transport or handle the IQ Battery.
+
DANGER: Risk of explosion. Do not dispose of IQ Battery(ies) in a re or by
burning. The IQ Battery(ies) can explode.
+
DANGER: Risk of re. During use, when stored, or during transport, keep the
IQ Battery in an area that is well ventilated and protected from the elements,
where ambient temperature is between -4° F and 113° F, and where relative
humidity is between 5 and 95 percent. Do not install the IQ Battery at eleva-
tions over 6,000 feet (1,829 m) above sea level.
+
DANGER: Risk of re. If the IQ Battery generates smoke, remove AC power
from the Enphase System so that charging/discharging stops.
+
DANGER: Risk of electric shock. Risk of re. Do not attempt to repair the IQ
Battery; it contains no user-serviceable parts. Tampering with or opening
the IQ Battery will void the warranty. Warranty void if the battery housing
is removed. If the IQ Battery fails, contact Enphase Customer Support for
assistance at enphase.com/en-us/support/contact.
+
DANGER: Risk of electric shock. Do not use Enphase equipment in a manner
not specied by the manufacturer. Doing so may cause death or injury to
persons, or damage to equipment.
+
DANGER: Risk of electric shock. Do not install the IQ Battery without rst
removing AC power from the photovoltaic system. Disconnect the power
coming from the photovoltaics before servicing or installing.
+
DANGER: Risk of electric shock. Always de-energize the AC branch circuit
during an emergency and/or before servicing the IQ Battery. Never discon-
nect the DC connectors under load.
+
DANGER: Risk of electric shock. Risk of high short-circuit current. Observe
the following precautions when working on batteries:
Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Wear rubber gloves and boots.
Do not lay tools or metal parts on top of batteries.
+
DANGER: Risk of electric shock. Risk of re. Do not work alone. Someone
should be in the range of your voice or close enough to come to your aid
when you work with or near electrical equipment.
+
DANGER: Risk of re. Do not allow or place ammable, sparking, or explosive
items near the IQ Battery.
+
DANGER: Risk of electric shock. In areas where ooding is possible, install
the IQ Battery at a height that prevents water ingress.
*
WARNING: Risk of equipment damage. During use, storage, transport, or
installation, always keep the IQ Battery in an upright position.
*
WARNING: You must install the IQ Battery only on a suitable wall using an
Enphase wall-mount bracket.
*
WARNING: Before installing or using the IQ Battery, read all instructions and
cautionary markings in this guide and on the equipment.
*
WARNING: Do not install or use the IQ Battery if it has been damaged in any
way.
*
WARNING: Do not exceed the maximum number (14) of IQ Batteries in a
20 A AC branch circuit.
*
WARNING: Do not sit on, step on, place objects on, or insert objects into the
IQ Battery.
*
WARNING: The IQ Battery is not waterproof. Do not place beverages or liquid
containers on top of the IQ Battery. Do not expose the IQ Battery to liquids or
ooding.
*
WARNING: Damage to the battery can occur from over-discharge. While in
storage, the IQ Battery will discharge. If the battery state of charge falls to 0%,
the IQ Battery can be damaged or destroyed. Because of this, the IQ Battery
must only be stored for a limited amount of time.
• The IQ Battery must be installed and energized by the “Must Energize By”
date on the shipping box label.
• The IQ Battery must have a charge state of no more than 30% when placed
in storage. To do this, the IQ Battery must be placed in Sleep Mode.
• If the IQ Battery has already been installed, it must be placed into
Sleep Mode prior to uninstalling. A battery in Sleep Mode can be stored
a maximum of two months from the date it was placed into Sleep Mode.
• When placing the IQ Battery in storage, ensure that AC power is not
present and that the DC connector is unplugged.
*
WARNING: Risk of equipment failure. Size the AC conductor gauge to ac-
count for voltage rise for both the branch circuit and all upstream conductors
leading back to the PCC (point of common coupling). Refer to the technical
brief on voltage rise at enphase.com/support.
NOTE: Perform installation and wiring in accordance with all applicable local
electrical codes and standards.
NOTE: Protection against lightning and resulting voltage surge must be in
accordance with local standards.
NOTE: Using unapproved attachments or accessories could result in dam-
age or injury.
NOTE: Use Class 1 wiring methods for eld wiring connections to terminals
of a Class 2 circuit. Use only 12 AWG to 20 AWG wire in the junction box
terminal block. Select the wire size based on the protection provided by the
circuit breakers / fuses. Install properly rated over current protection as part
of the system installation.
NOTE: To ensure optimal reliability and to meet warranty requirements, the
IQ Battery must be installed and/or stored according to the instructions in
this guide.
NOTE: The IQ Battery is compatible only with the IQ Envoy communications
gateway properly tted with production and consumption CTs. This Envoy
is required for operation of the IQ Battery. Earlier versions of the Enphase
Envoy communications gateway, and the Envoy-S gateway are incompatible.
NOTE: The Enphase IQ Battery is intended to operate with an Internet
connection. Failure to maintain an Internet connection may have an impact
on the warranty. See Limited Warranty for full terms and services (enphase.
com/warranty).
NOTE: When replacing an Enphase IQ Battery, you must replace it with an IQ
Battery of the same type, with the same AC current rating.
NOTE: When stored, the IQ Battery is not connected to the grid and no auto-
matic charge of the battery is possible.
NOTE: Never leave the battery on its back for more than ve minutes. The
battery cells are meant to be in the upright position.
NOTE: Properly mount the IQ Battery or place it on a at, plain surface that
can bear heavy weights. Ensure that the mounting location is structurally
suited to bearing the weight of the IQ Battery.
NOTE: During use, storage, and transport, keep the IQ Battery:
Properly ventilated
Away from water, other liquids, heat, sparks, and direct sunlight
Away from excessive dust, corrosive and explosive gases, and oil smoke
Away from direct exposure to gas exhaust, such as from motor vehicles
Free of vibrations
Away from falling or moving objects, including motor vehicles. If mounted
in the direct path of a motor vehicle, we recommend a 36-inch minimum
(91 cm) mounting height
At an elevation of fewer than 6,000 feet (1829 m) above sea-level
In a location compliant with re safety regulations (has a smoke
detector)
In a location compliant with local building codes and standards
NOTE: Conditions for the IQ Battery installation site apply also to storage
conditions.
SAFETY
IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This guide contains important instructions that you must follow during installation
and maintenance of the Enphase IQ Battery. Failing to follow any of these instructions may void the warranty (enphase.com/warranty).
In Case of Fire or Other Emergency
In all cases:
If safe to do so, switch off the AC breaker for the IQ Battery circuit, and if an
isolator switch is present, switch off the AC isolator for the IQ Battery circuit.
Contact the re department or other required emergency response team.
Evacuate the area.
In case of re:
When safe, use a re extinguisher. Suitable types are A, B, and C dry chemical
re extinguishers. Additional extinguishing media include carbon dioxide, or
alcohol-resistant foams.
In case of ooding:
Stay out of water if any part of the IQ Battery or wiring is submerged.
If possible, protect the system by nding and stopping the source of the
water, and pumping it away.
If water has contacted the battery, call your installer to arrange a replace-
ment. If not, let the area dry completely before use.
In case of unusual noise, smell or smoke:
Ensure nothing is in contact with the IQ Battery or in the venting area on top
of the IQ Battery.
Ventilate the room.
Contact Enphase Customer Support at enphase.com/en-us/support/contact.
Safety Instructions, continued
© 2017 Enphase Energy. All rights reserved.
Environmental Protection
ELECTRONIC DEVICE: DO NOT THROW AWAY. Waste elec-
trical products should not be disposed of with household
waste. Proper disposal of batteries is required. Refer to your
local codes for disposal requirements.
Assistance clientèle Enphase: enphase.com/en-us/support/contact
Symboles de sécurité et d’alerte
+
DANGER: ce symbole indique une situation dangereuse qui, si elle n’est pas évitée,
peut entraîner la mort ou des blessures graves.
*
AVERTISSEMENT: ce symbole indique une situation où le non-respect des con-
signes peut endommager l’appareil ou constituer un risque pour la sécurité. Soyez
extrêmement prudent et suivez attentivement les instructions.
REMARQUE: ce symbole indique une information particulièrement importante pour
le fonctionnement optimal du système. Suivez attentivement les instructions.
Instructions relatives à la sécurité
+
DANGER: risque d’électrocution. Risque d’incendie. L’installation, le dépannage ou le
remplacement de la batterieIQ doivent être réservés aux électriciens qualiés.
+
DANGER: risque d’incendie ou d’explosion. Le transport et la manipulation de la
batterieIQ doivent être réservés au personnel qualié, utilisant des équipements de
protection individuelle.
+
DANGER: risque d’explosion. Ne vous débarrassez pas des batteries IQ en les jetant
au feu ou en les brûlant. Celles-ci peuvent exploser.
+
DANGER: risque d’incendie. Lors de son utilisation, de son stockage ou de son
transport, conservez la batterieIQ dans une zone bien ventilée et protégée des
intempéries, dont la température est comprise entre -20°C et 50°C, et l’humidité rel-
ative, entre 5 et 95%. N’installez pas la batterieIQ à une altitude supérieure à 1829m
au-dessus du niveau de la mer.
+
DANGER: risque d’incendie. Si de la fumée s’échappe de la batterieIQ, coupez
l’alimentation du système Enphase an d’arrêter la charge/décharge.
+
DANGER: risque d’électrocution. Risque d’incendie. N’essayez pas de réparer la bat-
terieIQ; elle ne contient pas de pièces remplaçables par l’utilisateur. L’altération ou
l’ouverture de la batterieIQ annulera la garantie. La garantie est annulée si le boîtier
de la batterie est retiré. Si la batterieIQ tombe en panne, contactez l’assistance cli-
entèle Enphase pour obtenir de l’aide à la page enphase.com/en-us/support/contact.
+
DANGER: risque d’électrocution. N’utilisez jamais le matériel Enphase d’une manière
non spéciée par le fabricant. Cela peut entraîner la mort ou des blessures graves, ou
endommager l’équipement.
+
DANGER: risque d’électrocution. N’installez pas la batterieIQ sans avoir auparavant
débranché l’alimentationAC du système photovoltaïque. Débranchez l’alimentation
provenant des modules photovoltaïques avant de procéder à un dépannage ou à une
installation.
+
DANGER: risque d’électrocution. Débranchez toujours le circuit de dérivationAC en
cas d’urgence et/ou avant une maintenance de la batterieIQ. Ne débranchez jamais
les connecteursDC sous tension.
+
DANGER: risque d’électrocution. Risque de courant élevé de court-circuit. Prenez les
précautions suivantes lorsque vous manipulez des batteries:
Retirez votre montre, vos bagues ou tout autre objet métallique.
Utilisez des outils isolés.
Portez des gants et des bottes en caoutchouc.
Ne placez pas d’outils ni de pièces métalliques sur la partie supérieure des
batteries.
+
DANGER: risque d’électrocution. Risque d’incendie. Ne travaillez pas seul. Lorsque
vous travaillez sur ou à proximité d’un équipement électrique, quelqu’un doit se
trouver à portée de voix ou sufsamment près de vous pour pouvoir vous venir en
aide en cas de problème.
+
DANGER: risque d’incendie. Ne placez pas d’objets inammables, d’objets explosifs
ni d’objets générant des étincelles à proximité de la batterieIQ.
+
DANGER: risque d’électrocution. Dans les zones à risque d’inondation, installez la
batterieIQ à une hauteur qui empêche l’entrée d’eau.
*
AVERTISSEMENT: risque d’endommagement de l’équipement. Lors de son utili-
sation, de son transport ou de son installation, conservez toujours la batterieIQ en
position verticale.
*
AVERTISSEMENT: la batterieIQ doit être xée uniquement sur un mur adapté, en
utilisant une platine de xation murale Enphase.
*
AVERTISSEMENT: avant d’installer ou d’utiliser la batterieIQ, lisez toutes les instruc-
tions et tous les avertissements présents dans ce guide ou sur l’équipement.
*
AVERTISSEMENT: n’installez pas et n’utilisez pas la batterieIQ si celle-ci a été
endommagée de quelque manière que ce soit.
*
AVERTISSEMENT: n’installez pas plus de 14batteriesIQ par circuit de dériva-
tion AC de 20A.
*
AVERTISSEMENT: ne vous asseyez pas sur la batterieIQ, ne marchez pas dessus,
et ne placez pas d’objets sur ni dans cette dernière.
*
AVERTISSEMENT: la batterieIQ n’est pas étanche. Ne posez pas de boissons ni de
contenants de liquide sur la batterieIQ. N’exposez pas la batterieIQ aux liquides ni
aux inondations.
*
AVERTISSEMENT: une décharge excessive peut endommager la batterie. Lor-
squ’elle est entreposée, la batterieIQ se décharge. Si son niveau de charge tombe à
0%, la batterieIQ peut être endommagée ou devenir inutilisable. Pour cette raison, la
batterieIQ ne doit être entreposée que pour une durée limitée.
La batterieIQ doit être installée et alimentée avant la date «Must Energize By» («À
alimenter avant le») indiquée sur l’étiquette d’expédition.
Le niveau de charge de la batterie doit être supérieur à 30% lorsque
celle-ci est entreposée. Pour ce faire, la batterieIQ doit être placée en Mode veille.
Si la batterieIQ a déjà été installée, elle doit être placée en Mode veille avant d’être
désinstallée. Une batterie placée en Mode veille peut être entreposée pour une durée
de deux mois maximum, à compter du moment elle a été mise en Mode veille.
Lorsque vous entreposez la batterieIQ, assurez-vous que le courantAC est
absent et que le connecteurDC est débranché.
*
AVERTISSEMENT: risque de défaillance de l’équipement. Dimensionnez la sec-
tionAC des conducteurs en tenant compte de l’augmentation de tension à la fois
sur le circuit de dérivation et pour tous les conducteurs en amont qui sont reliés au
PCC (point de couplage commun). Reportez-vous à notre dossier technique sur les
augmentations de tension à la page enphase.com/support.
REMARQUE: réalisez toutes les installations et tous les câblages électriques en
respectant l’ensemble des normes et des codes électriques locaux en vigueur.
REMARQUE: la protection contre la foudre et la surtension qui en résulte doit être
conforme aux normes locales.
REMARQUE: l’utilisation de systèmes de xation ou d’accessoires non autorisés
peut entraîner des dégâts ou des blessures.
REMARQUE: utilisez des méthodes de câblage de classe1 pour les raccorde-
ments extérieurs à des terminaux d’un circuit de classe2. Utilisez uniquement des
conducteurs de diamètre 2,05mm (12AWG) à 0,812mm (20AWG) dans le bornier
du boîtier de raccordement. Choisissez la section des conducteurs en fonction du
calibre des disjoncteurs ou des fusibles. Utilisez une protection contre les surinten-
sités correctement calibrée pour l’installation du système.
REMARQUE: pour assurer une abilité optimale et répondre aux exigences de la
garantie, la batterieIQ doit être installée et/ou entreposée conformément aux instruc-
tions fournies dans le présent manuel.
REMARQUE: la batterieIQ est compatible uniquement avec la passerelle de
communication IQ Envoy, convenablement équipée de transformateurs de courant
de production et de consommation. Cet Envoy est requis pour que la batterieIQ
fonctionne. Les versions antérieures des passerelles de communication Enphase
Envoy et Envoy-S ne sont pas compatibles.
REMARQUE: la batterieIQ Enphase est conçue pour fonctionner avec une connexion
Internet. Si une connexion Internet ne peut être maintenue, cela peut avoir un impact sur
la garantie. Consultez la garantie limitée pour prendre connaissance de l’ensemble de
ses conditions et services (enphase.com/warranty).
REMARQUE: lorsque vous remplacez une batterieIQ Enphase, vous devez utiliser
une batterieIQ de même type et possédant le même courant nominalAC.
REMARQUE: lors de son stockage, la batterieIQ n’étant pas connectée au réseau
électrique, il n’y a pas de recharge automatique possible.
REMARQUE: ne laissez jamais la batterie sur sa face arrière pendant plus de cinqmin-
utes. Les cellules de la batterie sont conçues pour être placées en position verticale.
REMARQUE: xez correctement la batterieIQ, ou placez-la sur une surface plane
et lisse, capable de supporter un poids important. Veillez à ce que la structure de
l’emplacement de montage soit adaptée pour supporter le poids de la batterieIQ.
REMARQUE: lors de son utilisation, de son stockage et de son transport, veillez à ce
que la batterieIQ soit:
Correctement aérée
À distance de l’eau, d’autres liquides, de la chaleur, des étincelles et de la lumière
directe du soleil
À distance d’une poussière excessive, de gaz corrosifs et explosifs et defumée d’huile
À distance d’une exposition directe aux gaz d’échappement, comme ceux d’un
véhicule à moteur
Exempte de vibrations
À distance d’objets pouvant tomber ou se déplacer, notamment les véhicules à
moteur (si elle est montée directement à proximité d’un véhicule à moteur, nous
recommandons de la placer à une hauteur minimale de 91cm)
À une altitude de moins de 1829m au-dessus du niveau de la mer
Dans un emplacement conforme à la réglementation sur la sécurité-incendie (doté
d’un détecteur de fumée)
Dans un endroit répondant aux exigences des normes et des codes de
construction locaux
REMARQUE: les conditions relatives au site d’installation pour la batterieIQ s’ap-
pliquent également aux conditions de stockage.
SÉCURI
INSTRUCTIONS IMPORTANTES RELATIVES À LA SÉCURITÉ CONSERVEZ SOIGNEUSEMENT CES INSTRUCTIONS. Ce guide contient des instructions
importantes que vous devez suivre lors de l’installation et de la maintenance de la batterieIQ Enphase. Ne pas en tenir compte pourrait annuler
la garantie (enphase.com/warranty).
En cas d’incendie ou autre situation d’urgence
Dans tous les cas:
Si vous pouvez le faire sans danger, mettez le disjoncteurAC du circuit de la
batterieIQ hors tension, et s’il y a un interrupteur sectionneur sur le circuit de la
batterie IQ, mettez-le hors tension.
Contactez les pompiers ou toute autre équipe d’intervention d’urgence requise.
Évacuez la zone.
En cas d’incendie:
Lorsque cela ne présente pas de risque, utilisez un extincteur. Les extincteurs
adaptés sont les extincteurs à poudre chimique de type A, B et C. Vous pouvez
également utiliser du dioxyde de carbone ou des mousses résistant aux alcools.
En cas d’inondation:
Tenez-vous à l’écart de l’eau si une partie de la batterieIQ ou du câblage est
submergée.
Si possible, protégez le système en pompant l’eau après avoir identié et
bloqué la source d’écoulement.
Si votre batterie est entrée en contact avec de l’eau, appelez votre installateur
pour convenir d’un remplacement. Autrement, laissez la zone sécher
complètement avant utilisation.
En cas d’odeurs, de fumées ou de bruits inhabituels:
Veillez à ce que rien ne soit en contact avec la batterieIQ ni avec la zone de
ventilation située sur la partie supérieure de la batterieIQ.
Aérez la pièce.
Contactez l’assistance clientèle Enphase à l’adresse enphase.com/en-us/
support/contact.
Instructions relatives à la sécurité (suite)
©2017 Enphase Energy. Tous droits réservés.
Protection environnementale
DISPOSITIF ÉLECTRONIQUE: NE PAS JETER. Les déchets
de produits électriques ne doivent pas être jetés avec les
déchets ménagers. Les batteries doivent être mises au rebut
de manière adéquate. Reportez-vous aux règlements locaux
en matière de traitement des déchets.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

enphase IQ Battery Quick Installation Guide

Taper
Quick Installation Guide

dans d''autres langues