Vulcan 2GR45MF Manuel utilisateur

Catégorie
Friteuses
Taper
Manuel utilisateur
INSTALLATION &
OPERATIONAL MANUAL
GRMF SERIES GAS
FRYERS
MODELS:
2GR45MF ML-136417
2GR65MF ML-136418
2GR85MF ML-136419
3GR45MF ML-136420
3GR65MF ML-136421
3GR85MF ML-136422
4GR45MF ML-136423
2GR45MF Shown
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanequipment.com
©VULCAN 3600 NORTH POINT BLVD.
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BALTIMORE, MD 21222
WWW.VULCANEQUIPMENT.COM F-31233 REV. T (12-15)
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-2-
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL
GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND
ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE
EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN
SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER
FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-3-
TABLE OF CONTENTS
IMPORTANT FOR YOUR SAFETY…………………………....……………. 2
INTRODUCTION…………………….....…………………………………… 4
GENERAL…………………………...……………………………… 4
ORDERING PARTS…………………..………………………… 4
FRYER CAPACITIES………………..……………………………. 4
UNPACKING…………………………..…………………………… 4
INSTALLATION……………………………………......………………………. 5
Clearances…………………………………………………... 5
Location ………………..…………………...…………….…. 6
CODES AND STANDARDS……………………..………………….. 6
ASSEMBLY …………..………………………………....………… 7
FLUE CONNECTION……………………………………..…………. 7
GAS CONNECTION…………………………………………………. 8
Quick-Disconnect for Units on Casters……...…………… 8
GAS PRESSURE.......................................................................... 8
TEST GAS SUPPLY………………………………………………… 8
FRYERS WITH CASTERS………………………………………… 8
LEVELING THE FRYER…………………………..…………… 9
OPERATION…………………………………………...…….………………… 9
OVER-TEMPERATURE SHUTDOWN………….…………………. 10
BEFORE FIRST USE………………………………………………... 10
Cleaning…………………………………………………….... 10
FILLING TANK WITH SHORTENING………………....…………… 10
LIGHTING THE PILOT....................................................................11
TURNING ON THE FRYER ...................................................….12
TURNING OFF THE FRYER..........................................................12
EXTENDED SHUTDOWN…………………………………..……….. 12
BASIC FRYING INSTRUCTIONS…………………….………….. 12
Fry Basket Guidelines……………………….……..……. 13
EXTENDED SHORTENING LIFE…………………………...……… 13
DRAINING THE TANK…………………………………....…………. 14
DAILY FILTERING-ALL MODELS………………………....……. 14
CLEANING………………………………………………....…………. 15
Daily…………………………………………….……………. 15
BOIL OUT PROCEDURE……………………………………………….......... 15
KLEENSCREEN PLUS® INSTALLATION & OPERATION MANUAL....... 16
GAS KLEENSCREEN PLUS® MODELS………………………...16
FILTERING INSTRUCTIONS FOR KLEENSCREEN PLUS® FRYERS 17
GENERAL ………………………………………………………..... 17
ASSEMBLY……………………………………………………………. 17
OPERATION……………………………………………………………….…… 20
FILTERING PROCEDURE…………………………….................... 20
FILTERING TIP…………………………………………………....…. 21
REMOVING EXCESS DEBRIS FROM THE FILTER……...….. 21
FLUSH AND DISCARD…………………………………………..….. 22
BOIL OUT PROCEDURE……………………………………........ 23
THERMAL OVERLOAD PROTECTION RESET BUTTON…... 23
MAINTENANCE……………………………………………………….......….. 24
FLUE VENT INSPECTION………………………………...…….. 24
Service in the US and Canada……………………………....…... 24
TROUBLESHOOTING………………………………………………......…….. 23
Troubleshooting Chart……………………………………….………. 24
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-4-
INTRODUCTION
GENERAL
Vulcan Fryers are produced with quality workmanship and material. Proper installation,
usage and maintenance will result in years of satisfactory performance.
Before installing the fryer, thoroughly read this manual and carefully follow all instructions.
This manual is applicable to model listed on the cover page. Procedures in this manual
will apply to all models unless specified. Pictures and illustrations can be of any model
unless the picture or illustration needs to be model specific.
ORDERING PARTS
Customers may order parts directly from their local authorized service center. If not
known, call Vulcan Customer Service at 800-814-2028.
To speed up your order, provide the model number, serial number, gas type, part needed,
item part number (if known) and quantity needed.
FRYER CAPACITY
MODEL -
GMO
# of Heat Tubes
Each Fry Tank
BTU / Hour
Each Fry Tank
Width Inch (cm)
Total System
Shortening lbs. (kg)
Each Fry Tank
2GR45MF
4
120,000
31.0" (79)
45-50 (21-23)
3GR45MF
4
120,000
46.5" (118)
45-50 (21-23)
4GR45MF
4
120,000
62.0" (158)
45-50 (21-23)
2GR65MF
5
150,000
42.0" (107)
65-70 (29-32)
3GR65MF
5
150,000
63.0" (160)
65-70 (29-32)
2GR85MF
5
150,000
42.0" (107)
85-90 (39-41)
3GR85MF
5
150,000
63.0" (160)
85-90 (39-41)
UNPACKING
This fryer was carefully inspected before leaving the factory. The carrier assumes full
responsibility for the safe delivery upon acceptance of the shipment. Check for possible
shipping damage immediately after receipt.
If the fryer is found to be damaged, complete the following steps:
1. Carrier must be notified within 5 business days of receipt.
2. Carrier’s local terminal must be notified immediately upon discovery (note time,
date, and who was spoken to), and follow up and confirm with written or electronic
communication.
3. All original packing materials must be kept for inspection purposes.
4. The fryer cannot have been moved, installed, or modified.
5. Notify Vulcan Customer Service immediately at 800-814-2028.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-5-
Check that the following have been included:
Crumb Rack
Basket Hanger
Twin Fry Baskets (2)
Tank Brush
Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer
Batteries with the KleenScreen PLUS® Filtration System have casters installed
from the factory.
Drain Pipe Extension for freestanding fryers only.
Twin Fry Basket (2) per fry tank.
Cleanout Rod for freestanding fryers only.
Crumb Scoop for freestanding fryers only.
Manual and Warranty Retain for future reference.
Fryer Batteries with the KleenScreen PLUS® Filtration System
Filter Pan
Suction Tube
Screen Assembly
6’ (1829 mm) long high temperature discard hose
INSTALLATION
Do not use the door or its handle to lift the fryer.
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the
specifications on the fryer data plate, which is located on the inside of the door panel.
Make sure the fryer is configured for the proper elevation.
Record your fryer model, device, and serial numbers for future reference in the space
provided below. This information can be found on the fryer data plate.
Fryer Model No: ___________________________
Device:___________________________________
Serial No: ________________________________
Clearances
Minimum clearance from combustible construction:
6” (15 cm) from the sides of the fryer
6” (15 cm) from the back of the fryer
The fryer may be installed on combustible floors
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-6-
Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units: 16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion at fryer burners.
Do not obstruct the flow of combustion and ventilation air.
Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer.
Avoid wall-type fans, which create cross-currents within a room. Avoid open
windows next to sides or back.
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may
be obtained from The American Gas Association Accredited Standards Committee
Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards
Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,
available from the National Fire Protection Association, Batterymarch Park, Quincy,
MA.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained
from The National Fire Protection Association, Batterymarch Park, Quincy, MA.
02169-7471.
In the commonwealth of Massachusetts all gas appliances vented through a
ventilation hood or exhaust system with a damper or with a power means of
exhaust shall comply with 248 CMR.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-7-
In Canada:
Local codes
CAN/CSA-B149.1 Natural Gas and Propane Installation Code (latest
edition),available from the Canadian Standards Association, 155 Queen Street,
Suite 1300, Ottawa, Ontario Canada K1P 6L1.
CSA C22.1 Canadian Electric Code (latest edition), available from the Canadian
Standards Association, 155 Queen Street, Suite 1300, Ottawa, Ontario Canada
K1P 6L1.
ASSEMBLY
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means
of restraint may be the manner of installation, such as connection to a battery of
appliances, installing the fryer in an alcove, or by separate means such as adequate ties.
FLUE CONNECTION
Make the flue connection as follows:
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96
(latest edition), available from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.
Locate the fryer under a hood with adequate connection to an exhaust duct. The
hood must extend 6” (15 cm) beyond fryer on both sides.
Clearance above the fryer should be adequate for combustion byproducts to be
removed efficiently.
An 18” (46 cm) minimum clearance should be maintained between the flue vent
and the filters of the hood venting system.
Never make flue connections directly to the fryer.
Do not obstruct the flow of the gases from the appliance. Proper air balance should
be maintained in the room.
Ensure that your ventilation system does not cause a down draft at the fryer’s flue
opening. Down draft will not allow the fryer to exhaust properly and will cause
overheating which may cause permanent damage. Damage caused by down draft
will not be covered under equipment warranty. Never allow anything to obstruct the
flue or ventilation exiting from the fryer flue. Do not put anything on top of flue area.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-8-
GAS CONNECTION
All gas supply connections and any pipe joint compound must be
resistant to the action of propane gases.
The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff
valve be installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single
units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose,
¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.
Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A
battery requires one or two connections of appropriate size for the gas requirement.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
After piping has been checked for leaks, fully purge gas pipes to remove air.
GAS PRESSURES (ALL MODELS):
The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and
10 W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an
additional pressure regulator must be installed.
TESTING THE GAS SUPPLY PIPING SYSTEM:
When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve
must be disconnected from the gas supply piping system.
When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas
supply piping system by closing its individual shutoff valve.
Fryers with Casters:
Separate instructions for installing casters are included with the casters:
The installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA-
6.16, and a quick-disconnect device that complies with the Standard for Quick-
Disconnect Devices for Use with Gas Fuel, ANSI z21.41 CSA 6.9 or Quick-
Disconnect Devices for Use with Gas Fuel,
When installing a quick disconnect you must also install a means for
limiting the movement of the fryer. This device will prevent the gas line or quick
disconnect from being strained. The restraining device should be attached to the
cutout on the back panel. See illustration for location.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-9-
The fryer must be installed with a connector (not supplied by Vulcan) complying
with the above codes.
The fryer must be installed with restraining means to guard against transmission of
strain to the connector. See illustration.
The fryer must be installed with the casters provided.
If the restraint is ever to be disconnected, first turn the gas supply off. If
disconnection of the restraint is necessary, to reconnect this restraint after the fryer
has been returned to its originally installed position.
LEVELING THE FRYER
Check the level of the fryer by placing a level on top of the fryer after gas connections
have been made.
Ensure that the fryer is level front-to-back and side-to-side in the final installed position.
Lock the wheels after unit is level.
OPERATION
Hot oil and parts can cause burns. Use care when operating,
cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move
fryer without draining all frying compound from the tank.
Fryer is not to be used during a power outage
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-10-
OVER-TEMPERATURE SHUTDOWN
If the shortening becomes overheated, a high-temperature shutoff device will turn the gas
valve off and extinguish the pilot.
If the fryer shuts down due to overheating, DO NOT relight the pilot until the shortening
temperature is below 300 F (149 C).
If an overheating situation persists, contact your local Vulcan-Hart authorized service
office.
BEFORE FIRST USE
Cleaning
New units are wiped down at the factory to remove any visible signs of dirt, oil, grease,
etc. remaining from the manufacturing process.
Before any food preparation, thoroughly wash the protective oil from all surface parts and
the tank interior with hot soapy water to remove any film residue and dust or debris.
Do not use chlorine or sulfate/sulfide cleaners.
Wash any accessories shipped with unit.
Rinse fryer and accessories thoroughly and drain the fryer.
Wipe tank completely dry with a soft, clean cloth.
FILLING TANK WITH SHORTENING
Solid shortening must NOT be used with GRM fryers. Melting solid
shortening will damage the tank and void your warranty.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-11-
Close the drain valve.
Fill the fryer tank with liquid shortening.
Shortening level should be between the min and max lines in the fryer tank.
Shortening will expand when heated. Do not fill the fryer tank past the
MAX line.
Add fresh shortening as needed to maintain oil level.
LIGHTING THE PILOT
A C
B
A Gas Control Lever
B Gas Valve
C Thermostat
1. Open the door.
2. Turn the thermostat to OFF The thermostat is located behind the door.
3. Push the gas control valve knob and turn to OFF (see figure below, view A). Wait 5
minutes for unburned gas to vent.
4. Push and turn gas control valve knob to the L in PILOT (see figure below, view B).
5. While still holding the knob in, light the pilot with a lit flame. Continue to depress
the knob until pilot remains lit when knob is released. If the pilot does not remain lit,
repeat step 3 through 5.
6. Depress and turn gas control knob to ON (See figure below, view C).
7. If gas supply is interrupted, repeat steps 2 through 6.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-12-
TURNING ON THE FRYER
Set the temperature knob to desired temperature.
After the set temperature has been reached, the thermostat shuts off the gas flow
to burners.
The pilot remains lit. The burners will cycle on and off, maintaining the set
temperature.
TURNING OFF THE FRYER
1. Turn the thermostat OFF.
2. To keep the pilot lit, turn the gas valve to “L” in Pilot.
3. To shut off all gas to the system, including the pilot, turn the gas valve knob to
the OFF position.
EXTENDED SHUTDOWN
1. Turn the thermostat knob to OFF.
2. Push in the pilot knob and turn to OFF.
3. Thoroughly drain the fryer. Refer to DRAINING THE FRYER.
4. Clean the fryer according to CLEANING.
5. Turn off the main gas shutoff valve.
BASIC FRYING INSTRUCTION
Set the desired temperature and allow shortening to heat up to that temperature.
Fry items that are the same size to ensure equal doneness.
Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot
shortening.
Add fresh shortening as needed.
Fry Basket Guidelines
Do not overfill baskets. (See table for recommended basket capacities below)
Carefully lower basket into oil.
When frying doughnuts and fritters, turn product only once during frying.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-13-
When cooking French fries or onion rings, shake the basket several times.
Batter-covered foods should be dropped carefully, one by one, into shortening or
basket. If you use the basket, first dip the basket into the shortening to
reduce batter-build up on basket surfaces.
When frying is completed, remove basket or product. Hang basket on rear
hanger.
Fry Basket Capacity:
1GR35M: Recommended pounds per basket are 1.5 lbs. (0.7 kg).
1GR45M: Recommended pounds per basket are 2.5 lbs. (1.1 kg).
1GR65M: Recommended pounds per basket are 3.0 lbs. (1.4 kg).
1GR85M: Recommended pounds per basket are 3.5 lbs. (1.6 kg).
EXTENDING SHORTENING LIFE
Shortening life can be extended by the following guidelines:
Do not salt foods over the fryer.
Use good-quality shortening.
Filter shortening daily (at a minimum).
Replace shortening if it becomes poorly flavored.
Keep equipment and surrounding clean. Use tank covers when not in use.
(accessory).
Set thermostat correctly.
Remove excess moisture and particles from food products before placing on fryer.
Use a fitted tank cover (accessory) to keep oil covered from light and oxygen
DRAINING THE OIL Free Standing Fryers Only
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
1. Turn the thermostat knob to the OFF position. .
2. Insert the drain extension into the drain valve. Tighten only hand tight.
3. Direct the drain extension into the mobile filtering device that you want to use.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-14-
4. Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan. Then open
the drain valve all the way.
5. When fry tank is empty use the tank brush to remove any additional debris.
6. Close the drain valve.
7. Fill tank with new shortening. Fill to a minimum of the MIN level but no higher than halfway
between MIN and MAX. Oil will expand as it is heated.
8. After the fry tank is filled with new oil, turn the thermostat knob to the desired set
temperature. The burners will come on and will heat the oil.
CLEANING
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Daily
Clean your fryer regularly with the tank brush along with a damp cloth, and polish with a
soft dry cloth. If regular cleaning is neglected, grease will be burned on and discolorations
may form.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-15-
Fingerprints are sometimes a problem on highly polished surfaces of stainless steel. They
can be minimized by applying a cleaner that will leave a thin oily or waxy film.
Clean all exterior surfaces of your fryer at least once daily.
Use a damp cloth with warm water and a mild soap or detergent.
Do not use chlorine or sulfate/sulfide cleaners.
Rinse thoroughly, and then polish with a soft dry cloth.
Keep the fryer exterior clean and free of accumulated grease to prevent stubborn
stains from forming. If regular cleaning is neglected, grease will be burned on and
discolorations may form.
Remove discolorations by washing with any detergent or soap and water.
Use a self-soaping, non-metallic scouring pad for particularly stubborn
discolorations.
Always rub with the grain of the stainless steel.
Do not use a metallic scoring pad or harsh cleaners.
BOIL OUT PROCEDURE
Weekly or as required:
1. Drain the tank as described under DRAINING THE TANK.
2. Once the shortening has been drained, flush out scraps and sediment using the
provided tank brush.
3. Close the drain valve and fill tank water. Use a low foaming cleaner/degreaser to
clean the fry tank. Follow the instructions on the side of the package.
Do not use chlorine or sulfate/sulfide cleaners.
4. Solution level must be between the MIN and MAX levels on the fryer tank.
5. Set the temperature knob to 200°F or for the recommended solution being used.
Allow solution to simmer for about 15 to 20 minutes.
6. Drain the cleaning solution from the tank.
7. Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to
neutralize alkaline left by the cleaner. Solution level must be between the MIN and
MAX level on the fryer tank.
8. Bring the solution to a simmer only, turn the thermostat off. Allow to stand for a few
minutes.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-16-
9. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear,
hot water. All traces of cleaner must be removed. Dry the tank thoroughly.
10. Close the drain valve and add shortening. Follow the FILLING TANK WITH
SHORTENING procedure in this manual. The fryer is now ready for use.
KleenScreen PLUS® Filtration System
Installation and Operational Manual
For GRMF Models
2GR45MF ML-136417
2GR65MF ML-136418
2GR85MF ML-136419
3GR45MF ML-136420
3GR65MF ML-136421
3GR85MF ML-136422
4GR45MF ML-136423
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-17-
Filtering Instructions for KleenScreen PLUS® Fryers
General
The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective
tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both
tanks be drained at the same time.
Assembly
1. After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure
you remove the insert located inside the filter screen. Use dishwashing detergent and
warm water, (parts are dishwasher safe). Rinse the filter pan, crumb basket and filter
screen components completely and wipe all parts dry with a clean cloth.
2. Pull out the filter drawer all the way leaving the filter pan opening exposed.
3. Place the filter tank into the filter drawer making sure that the pins on the bottom of the filter
pan line up with the holes in the filter drawer. Position the filter screen assembly into the
suction tube clip in the filter pan positioning the filter screen assembly flat on the bottom of
the filter pan. Place the primary crumb basket onto the left handle of the filter pan.
4. Carefully line up the suction tube nozzle so that it mates with the oil receptacle block
mounted on the frame of the fryer battery. Close the drawer. See Figures 1, 2 3 and 4.
Suction Tube
Filter Screen
Filter Insert
Knurled Bottom
Fitting
Fig. 1
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-18-
Fully assembled filter screen assembly:
Fig. 2
Secure Tube with
Suction Tube Clip
Filter Screen Lays
Flat On Bottom of
Filter Pan
Fig. 3
Micro-Filtration Fabric Envelope Accessory Assembly: Same Suction Tube
Fabric Envelope Insert
(Different from Screen Assembly)
Fabric Envelope
Same Clip
Same Knurled Knob
Fig. 4
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-19-
INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE ACCESSORY
FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER
ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
Step 1
Discard all oil from the filter vessel, (see pages 23 or 24). When the
filter pan is empty, use a spatula and scrape off all debris left on the
filter envelope and in the filter pan.
Step 2
Unscrew “S” Tube from filter by turning the Bottom Knurled fitting
counter- clockwise.
Step 3
Remove SST Closure Clip by lifting off one side.
Step 4
Remove SST Filter Screen Insert and wash insert with hot water and
dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the
insert into a new KleenScreen PLUS® Filter envelope.
DO NOT WASH FABRIC ENVELOPE
Step 5
Place Filter Screen Insert into the fabric envelope making sure that the
holes line up. Fold over the other end of the envelope and place SST
Closure Clip on hinge over and firmly press clip all the way down to
secure and seal filter assembly. Making sure that the folded end is face
down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the
Bottom Knurled fitting. When tightened, the “S” Tube assembly should
be perpendicular to the long side of the filter assembly.
Step 6
Reposition the filter tube into the provided clip. Align filter tube so that
the end of the “S” Tube engages the Oil Receptacle fitting each time the
drawer is opened and closed.
GRMF SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. T (12-15)
-20-
Operation
Hot oil and parts can cause burns. Use care when operating,
cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move
fryer without draining all frying compound from the tank.
Never run water or boil out solution through filter and motor / pump. Doing so
will void your fryer warranty.
Solid shortening should NOT be used with GRM fryers. Melting solid
shortening will damage the tank and void your warranty.
Filter ONLY one fry tank at a time.
FILTERING PROCEDURE WHEN USING LIQUID SHORTENING:
Oil Temperature should be 300-350° F. Use the provided crumb scoop to remove and suspend
crumbs on the bottom of the tank before proceeding to Step 1.
1. Turn the Fryer temperature knob to the OFF position.
Do NOT heat the fryer during the filtering procedure. Permanent damage to your
fry tank may occur and warranty may be voided.
2. Vulcan recommends adding an oil treatment media to the oil prior to filtering.
3. Turn the Gas Valve Lever to the PILOT Position as shown in Fig. 5a.
4. Press the Filter Power switch to the ON position, Fig. 5b. Make sure that the filter drawer is
closed completely and that the suction tube and receptacle block are in the correct position.
Fig. 5c.
Fig 5a Fig. 5b Fig. 5c
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49

Vulcan 2GR45MF Manuel utilisateur

Catégorie
Friteuses
Taper
Manuel utilisateur

dans d''autres langues