Twin Eagles Power Burner Gas Conversion Instruction

Taper
Gas Conversion Instruction
In Massachuses: All gas products must be installed using a “Massachuses”
licensed plumber or gas er. A “T” handle type manual gas valve must be
installed in the gas supply line to this appliance. This applies to permanently
installed natural gas and propane installaons. This does not apply to
propane portable installaons using a 20 pound tank.
!
WARNING
BEFORE WORKING ON THIS APPLIANCE, DISCONNECT
GAS AND ELECTRICAL SUPPLIES.
!
WARNING
INSTALLATION/GAS CONVERSION MUST BE PER-
FORMED BE A QUALIFIED TECHNICIAN.
TWIN EAGLES POWER BURNER
GAS CONVERSION KIT FROM NG TO LP
PN: CKLP-TEPB
FOR MODELS: TEPB
FOR YOUR RECORDS
IMPORTANT: Retain original proof of purchase to establish warranty
period.
Please record the following informaon and refer to this informaon
when contacng the company or an authorized service agent. This
informaon is found on the rang/data plate located on the inside wall
of the rebox.
Serial No. of Power Burner:
___________________________________________________________
Date of LP Gas Conversion:
___________________________________________________________
LP Gas Conversion by:
___________________________________________________________
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the
State of California to cause cancer and reproducve harm. To minimize exposure to the by-
products of the burning fuel or from combuson, always operate this unit according to the
use and care manual and provide good venlaon. California law requires businesses to warn
customers of potenal exposure to such substances. For more informaon go to
www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L’ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne
reconnue dans l’Etat de la Californie pour causer le cancer et des problemes de ferlite. Pour
minimiser l’exposion de ces-sous produits combusbles ou de la combuson, uliser toujours
cet appareil en conformitee au manuel d’ulisaon et d’entreen en s’assurant egalement
d’une bonne venlaon. La loi de la Californie exige aux fabricants d’informer leurs clients aux
risques d’exposion potenelle a de telles substances. Pour plus d’informaon, visiter le site
www.P65Warnings.ca.gov
1. Check to make sure that you have the LP Gas Conversion Kit as follows:
A. PN: 15110-49, Orice #49 (1 pc)
B. PN: 15110-53, Orice #53 (1 pc)
C. PN: S16110, Wire Tie (2 pcs)
D. PN: 18351, Label, Conversion, Gas (1 pc)
E. PN: 18655: Gas Conversion Instrucon (1 pc)
2. Gas Conversion
A. Remove the grates and set them aside.
B. Li then pull the brass burner towards the back.
Note: Ensure that the wires for the igniter are not damage while
pulling o the burner. When removing the burner, you may need to
remove the front panel and cut the wire es that are retaining the
excess length of igniter wire. Use the wire es provided to retain the
wire aer the leak test is performed.
C. Replace the orice #41 used on NG (Inner Ring of the Burner), and
replace it with orice #53, used for LP (Inner Ring of the Burner). Use
a 1/2” Deep Socket and a Socket Wrench to remove and replace the
orice. (Fig. 1)
D. Replace the orice #30 used on NG (Outer Ring of the Burner), and
replace it with orice #49, used for LP (Outer Ring of the Burner). Use
a 1/2” Deep Socket and a Socket Wrench to remove and replace the
orice. (Fig. 1)
E. Set the air shuer opening to the following specicaon: (Fig. 2)
Inner Ring Air Shuer: 3/8”
Outer Ring Air Shuer: 3/4”
F. The regulator is located on the boom right side of the Power Burner.
Remove the cap on the regulator then remove the center plasc insert
and invert it to show the LP marking. Put the cover back. Connect LP
gas line to the regulator directly.
3. Tesng
A. Make sure the regulator has been properly connected, replaced for LP
Gas
B. Check for leaks.
C. NEVER USE THE UNIT WITHOUT FIRST LEAK TESTING THE GAS
CONNECTION.
a. Prepare a leak tesng soluon of sudsy water by mixing in a spray
bole with half liquid soap and half water.
b. Conrm that all control knobs are in the “OFF” posion.
c. Turn the main gas valve supply “ON”.
d. Apply leak tesng soluon by spraying on the pipe joints, ngs, and
hose.
e. A gas leak is detected if;
i. there is a faint gas smell and/or
ii. growing bubbles appear on any of the connecon points and/or
hose. DO NOT aempt to turn on the burners and IMMEDIATELY
turn o the gas supply valve.
F. When there is a gas leak, call a qualied service technician. DO NOT
use the unit unl the leak is corrected.
G. Fill up the Conversion Label. Next, paste it next to the original Serial
Plate.
H. The conversion is complete and the unit is ready for installaon. Refer
back to the Installaon Manual.
PN: 18655E 07/19
Before
(Set to NG)
Aer
(Set to LP)
ORIFICE BURNER
(OUTER RING)
ORIFICE BURNER
(INNER RING)
FIG. 1
FIG. 2
INNER RING AIR
SHUTTER
OUTER RING AIR
SHUTTER
  • Page 1 1
  • Page 2 2

Twin Eagles Power Burner Gas Conversion Instruction

Taper
Gas Conversion Instruction

dans d''autres langues