In Massachuses: All gas products must be installed using a “Massachuses” licensed plumber
or gas er. A “T” handle type manual gas valve must be installed in the gas supply line to this
appliance. This applies to permanently installed natural gas and propane installaons. This
does not apply to propane portable installaons using a 20 pound tank.
PN: 18981E 04/19
GAS CONVERSION KIT FROM NG TO LP (PROPANE), P/N CKLP-TEBQ54
FOR MODELS: TWIN EAGLES GRILLS, TEBQ54
1. All gas connecons/conversions should be made by a qualied technician and in
accordance with local codes and ordinances.
2. Before conducng a conversion to a gas appliance, verify that the main gas is shut
o and disconnected from the appliance.
3. Ensure that you have the LP Gas Conversion Kit , as follows:
A. P/N 15110-53, Orice #53, LP, Grill Burner (4 pcs.)
B. P/N 15108-57, Orice #57, Ros (2 pc.)
C. P/N 15302, LP Regulator with 24” Hose (1 pc.)
D. P/N 12602, Coupling, 3/8 M are X ½ FIP (1 pc.)
E. P/N 18351, Label, Conversion Gas (1 pc.)
4. Replace burner valve orices.
A. Grill Burner:
a. Remove cooking grates
b. Remove briquee trays
c. Remove grill burners
d. Remove grill burner orices, #41 drill size
e. Replace grill burner orices with #53 drill size
f. Adjust the burner shuer for the appropriate gas type. (An “L” and an “N” are
stamped on the air shuer to indicate the appropriate gas type.)
g. Install back the burners, briquee trays & cooking grates. WARNING! IT IS
CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED WITH THEIR
ORIFICES INSIDE THE BURNERS AIR SHUTTERS. If not properly installed,
gas may leak outside of the burner that could lead to re, potenal
damage to your grill and bodily injury.
B. Infrared Rosserie Burner
a. Remove rear hood cover to expose infrared burner gas orice
b. Remove ros burner orice #50.
c. Replace ros burner orice with #57.
d. Replace rear hood cover.
5. Replace the NG regulator with the factory supplied LP regulator.
A. Disconnect regulator from grill
B. Install the brass coupling ½ female pipe x 3/8 male are
C. Install the factory-supplied regulator and hose assembly. Connect the 3/8”
are end of the hose to the grill coupling using a ¾” open wrench. Do not
apply pipe sealant to the 3/8” are connecon. Connect the regulator to the
LP cylinder hand ghten it, do not use a wrench.
D. Check for gas leaks using soapy water soluon.
6. NEVER USE THE GRILL WITHOUT FIRST LEAK TESTING THE GAS CONNECTION.
A. Prepare a leak tesng soluon of sudsy water by mixing in a spray bole with
half liquid soap and half water.
B. Conrm that all control knobs are in the “OFF” posion.
C. Turn the main gas valve supply “ON”.
D. Apply leak tesng soluon by spraying on the pipe joints, ngs, and hose.
E. A gas leak is detected if;
a. there is a faint gas smell and/or
b. growing bubbles appear on any of the connecon points and/or hose. DO
NOT aempt to ignite the grill and IMMEDIATELY turn o the gas supply
valve.
F. When there is a gas leak, call a qualied service technician. DO NOT use the
grill unl the leak is corrected.
7. Calibrate burner low ame seng
A. The grill must be hooked up to the gas supply in order to calibrate burner.
B. Turn on burner and set to low. At low seng, all ports of the burner must
remain lit. If the ames are too high or too low, calibrate burner valve.
C. To calibrate burner valve, pull o valve knob. Insert a skinny at screwdriver
into the valve stem
D. Turn the adjusng screw inside the stem clockwise to decrease ame or
counter clockwise to increase ame.
E. Perform leak test on the valve stem using the soapy water soluon.
8. The conversion is complete. Fill up the Conversion Label. Next, paste it next to
the original Serial Plate.
9. The unit is ready for installaon. Please refer back to the User’s Manual to insure
safety, proper care and operaon.
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the
State of California to cause cancer and reproducve harm. To minimize exposure to the by-
products of the burning fuel or from combuson, always operate this unit according to the
use and care manual and provide good venlaon. California law requires businesses to warn
customers of potenal exposure to such substances. For more informaon go to
www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L’ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne
reconnue dans l’Etat de la Californie pour causer le cancer et des problemes de ferlite. Pour
minimiser l’exposion de ces-sous produits combusbles ou de la combuson, uliser toujours
cet appareil en conformitee au manuel d’ulisaon et d’entreen en s’assurant egalement
d’une bonne venlaon. La loi de la Californie exige aux fabricants d’informer leurs clients aux
risques d’exposion potenelle a de telles substances. Pour plus d’informaon, visiter le site
www.P65Warnings.ca.gov