KitchenAid YMMV6190FZ1 Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE
MICROWAVE HOOD COMBINATION SAFETY
This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See “Installation
Requirements” section for further notes.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in
these installation instructions.
Ce produit est conçu pour l’utilisation au-dessus d’appareils de cuisson électriques ou à gaz de 36" (91,4 cm) de largeur ou moins. Voir
la section “Exigences d’installation” pour d’autres remarques.
Ces instructions d’installation sont valables pour plusieurs modèles. Il se peut que l’apparence de votre propre modèle soit légèrement
différente de celle montrée sur les illustrations dans ce document.
Table of Contents / Table des matières
MICROWAVE HOOD COMBINATION SAFETY...................... 1
INSTALLATION REQUIREMENTS........................................... 2
Tools and Parts ...................................................................... 2
Remove Cardboard Template ............................................... 2
Location Requirements.......................................................... 2
Product Dimensions .............................................................. 3
Electrical Requirements ........................................................ 3
INSTALLATION INSTRUCTIONS............................................. 4
Remove Mounting Plate......................................................... 4
Rotate Blower Motor.............................................................. 4
Locate Wall Stud(s) ................................................................ 6
Mark Rear Wall....................................................................... 7
Drill Holes in Rear Wall........................................................... 7
Attach Mounting Plate to Wall ............................................... 8
Prepare Upper Cabinet.......................................................... 8
Install Damper Assembly ....................................................... 9
Install the Microwave Oven.................................................... 9
Complete Installation ........................................................... 10
VENTING DESIGN SPECIFICATIONS................................... 11
ASSISTANCE........................................................................... 12
Replacement Parts............................................................... 12
Accessories.......................................................................... 12
SÉCURITÉ DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE..........13
EXIGENCES D'INSTALLATION...........................................................13
Outillage et pièces.............................................................................13
Dépose du gabarit de carton ............................................................14
Exigences d'emplacement................................................................14
Dimensions du produit .....................................................................14
Spécifications électriques .................................................................15
INSTRUCTIONS D'INSTALLATION....................................................15
Dépose de la plaque de montage.....................................................15
Réorientation du moteur du ventilateur ............................................15
Identifier la position du/des poteau(x) du colombage mural............17
Tracé sur le mur arrière .....................................................................18
Perçage de trous dans le mur arrière................................................19
Fixation de la plaque de montage sur le mur ...................................19
Préparation du placard supérieur .....................................................20
Installation du module du clapet anti-reflux......................................21
Installation du four à micro-ondes ....................................................21
Achever l'installation..........................................................................22
SPÉCIFICATIONS/CONCEPTION DU CIRCUIT D'ÉVACUATION........23
ASSISTANCE........................................................................................24
Pièces de rechange...........................................................................24
Accessoires .......................................................................................24
W10724871A
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
2
INSTALLATION REQUIREMENTS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Parts Supplied
For information on reordering, see “Replacement Parts” section.
NOTE: The hardware items listed here are for wood studs. For
other types of wall structures, be sure to use appropriate
fasteners.
NOTE: Depending on model, aluminum grease filter and charcoal
filter may be combined.
Materials needed
Standard fittings for wall or roof venting. See “Venting Design
Specifications” section.
Remove Cardboard Template
The cardboard piece from the top of the microwave oven
packaging is perforated. The piece inside the perforation is for use
as a rear wall template.
1. Cut along the perforation to separate the template from the
rest of the cardboard packaging.
2. Set the cardboard template to the side and refer to it during
the “Mark Rear Wall” part of installation.
Location Requirements
Check the opening where the microwave oven will be installed.
The location must provide:
Minimum installation dimensions. See “Installation
Dimensions” illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum 3/8" (10 mm) thickness drywall or plaster/lath within
cabinet opening.
Support for weight of 150 lbs (68 kg), which includes
microwave oven and items placed inside the microwave oven
and upper cabinet.
Grounded electrical outlet inside upper cabinet. See
“Electrical Requirements” section.
NOTES:
If installing the microwave oven near a left sidewall, make sure
there is at least 6" (15.2 cm) of clearance between the wall and
the microwave oven, so that the door can open fully.
Some cabinet and building materials are not designed to
withstand the heat produced by the microwave oven for
cooking. Check with your builder or cabinet supplier to make
sure that the materials used will not discolor, delaminate or
sustain other damages.
Special Requirements
For Wall Venting Installation Only:
Cutout must be free of any obstructions so that the vent fits
properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If you are using a rectangular to round transition piece, the
3" (7.6 cm) clearance needs to exist above the microwave
oven so that the damper blade can open freely and fully. See
“Rectangular to Round Transition” illustration in “Venting
Design Specifications” section.
Measuring tape
Pencil
Masking tape or thumbtacks
Scissors
No. 2 Phillips screwdriver
No. 3 Phillips screwdriver for
1/4-20 x 3" bolts
Drill
3/16" (5 mm), 3/8" (10 mm),
5/8" (16 mm) drill bits
3/4" (19 mm) hole saw
Diagonal wire cutting pliers
Stud finder
7/16" socket wrench
(or box wrench) for 1/4" x
2" lag screws
1½" (3.8 cm) diam. hole
drill bit for wood or metal
cabinet
Keyhole saw
Caulking gun and
weatherproof caulking
compound
Duct tape
A. 3/16-24 x 2" round-head bolts (2)
B. 1/4-20 x 3" flat-head bolts (2)
C. Washers (2)
D. 3/16" toggle nuts (2)
E. 1/4" x 2" lag screws (2)
F. Sheet metal screws (2)
G. Power supply cord bushing (1)
H. Damper assembly (for wall or roof
venting)
Not Shown:
Upper cabinet template
Mounting plate (attached to
back of microwave oven)
Cardboard template (part of
packaging)
Aluminum grease filters
Charcoal filters (Depending
on model, charcoal filters
may not be included. See
User Instructions.)
A
B
C
D
EF
G
H
3
Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See “Electrical Requirements” section.
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop
below.
Product Dimensions
*Overall depth of product will vary slightly depending on door
design.
Electrical Requirements
Observe all governing codes and ordinances.
Required:
A 120 volt, 60 Hz, AC only, 15- or 20-amp electrical supply
with a fuse or circuit breaker.
Recommended:
A time-delay fuse or time-delay circuit breaker.
A separate circuit serving only this microwave oven.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
12" (30.5 cm) min.
14" (35.6 cm) max.
30"
(76.2 cm)
min.
A B
upper cabinet and
side cabinet depth
30"
(76.2 cm)
typical*
66" (167.6 cm) min.
29
⁷⁄₈
" (76.0 cm)
17
¹⁄₈
"
(43.5 cm)
+/-
³⁄₁₆
"
(0.5 cm)
16
¹⁄₄
"
(41.3 cm)
Up to
16
³⁄₄
"
(42.5 cm)*
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
4
INSTALLATION INSTRUCTIONS
Remove Mounting Plate
Depending on your model, the mounting plate may be in the foam
packaging, or it may be attached to the back of the microwave
oven.
NOTE: To avoid possible damage to the work surface, cover the
work surface.
1. Remove any remaining contents from the microwave oven
cavity.
2. If the mounting plate is attached to the back of the microwave
oven, remove it and set it aside.
3. Tape the microwave oven door closed so that door does not
swing open while the microwave oven is being handled.
NOTE: To avoid damage to the microwave oven, do not grip or
use the door or door handle while the microwave oven is being
handled.
Rotate Blower Motor
The microwave oven is set for recirculation installation. For wall or
roof venting, changes must be made to the venting system.
NOTE: Skip this section if you are using recirculation installation.
Keep the damper assembly in case the venting method is
changed, or the microwave oven is reinstalled in another location
where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove screws attaching damper plate to top of microwave
oven exterior. Slide damper plate toward the front of the
microwave oven and lift up.
2. Keep damper plate and screws together and set aside.
3. Remove 2 screws attaching blower motor to back of
microwave oven.
4. Lift blower motor out of microwave oven.
5. Rotate blower motor 180° so that exhaust ports face the back
of microwave oven, and lower blower motor back into the
microwave oven.
A. Screws
B. Damper plate
A
B
A. Screws (in recessed holes)
A. Blower motor
A. Exhaust port
A
A
A
5
6. Using diagonal wire cutting pliers, gently snip out the
rectangular damper vent covers at the perforations.
7. Reattach blower motor to back of microwave oven with 2
screws removed in Step 3.
8. Reattach damper plate. Make sure damper plate tabs are
inserted into the slots in the top of the microwave oven
.
9. Secure damper plate with 2 screws removed in Step 1.
Roof Venting Installation Only
1. Repeat Step 1 from “Wall Venting Installation Only.”
2. Repeat Step 2 from “Wall Venting Installation Only.”
3. Repeat Step 3 from “Wall Venting Installation Only.”
4. Repeat Step 4 from “Wall Venting Installation Only.”
5. Rotate blower motor so that exhaust ports face the top of
microwave oven, and flat sides of blower motor face back of
microwave oven. Lower blower motor back into microwave
oven.
IMPORTANT: If blower motor is not positioned with flat sides
facing the back of the microwave oven (as shown), performance
will be poor.
6. Reattach blower motor to back of microwave oven with 2
screws removed in Step 3 of “Wall Venting Installation Only.”
Securely tighten screws.
NOTE: If blower motor is not correctly oriented, the 2 screws
removed in Step 3 cannot be reattached to the microwave oven.
7. Using diagonal wire cutting pliers, gently snip out the
rectangular vent covers on the damper plate removed in
Step 1, at the perforations.
8. Reattach damper plate. Make sure damper plate tabs are
inserted into the slots in the top of the microwave oven.
9. Secure damper plate with 2 screws removed in Step 1 of “Wall
Venting Installation Only.”
A. Diagonal wire cutting pliers
B. Damper vent covers
A. Damper plate
B. Screws
C. Damper plate tabs
D. Slots
B
A
A
B
C
D
A. Exhaust port
A. Diagonal wire cutting pliers
B. Rectangular vent covers
A. Damper plate
B. Screws
C. Damper plate tabs
D. Slots
B
A
A
B
C
D
6
Locate Wall Stud(s)
NOTE: If no wall studs exist within the cabinet opening, do not
install the microwave oven.
See illustrations in “Possible Wall Stud Configurations.”
1. Using a stud finder, locate the edges of the wall stud(s) within
the opening.
2. Mark the center of each stud, and draw a plumb line down
each stud center. See illustrations in “Possible Wall Stud
Configurations.”
Possible Wall Stud Configurations
These depictions show examples of preferred installation configurations with the mounting plate.
No Wall Studs at End Holes
Figure 1
No Wall Studs at End Holes
Figure 2
NOTE: If wall stud is within 6" (15.2 cm) of the vertical
centerline (see “Mark Rear Wall” section), only recirculation or
roof venting installation can be done.
Wall Stud at One End Hole
Figure 3
Wall Studs at Both End Holes
Figure 4
A. End holes (on mounting plate)
B. Cabinet opening vertical centerline
C. Wall stud centerlines
D. Holes for lag screws
E. Support tabs
F. Mounting plate center markers
A
A
B
C
C
D
E
E
F
A
A
B
C
D
E
E
F
A
A,D
B
C
C
D
E
E
F
A,D
B
E
A,D
C
E
C
F
7
Mark Rear Wall
The microwave oven must be installed on a minimum of 1 wall
stud, preferably 2, using a minimum of 1 lag screw, preferably 2.
1. Using measuring tape, find and clearly mark the vertical
centerline of the opening.
A. Centerline
2. Align the center markers on the cardboard template (carton
top cap) to the centerline on the wall, making sure it is level,
and that the top of the cardboard template is butted up
against the bottom edge of the upper cabinet.
NOTES:
If the front edge of the upper cabinet is lower than the back
edge, lower the cardboard template so that its top is level with
the front edge of the cabinet.
If the cardboard template is damaged or unusable, measure
and mark the wall with the dimensions described in Step 4.
3. Holding the cardboard template in place, mark both holes in
the lower corners, and draw a horizontal line across the
bottom edge of the cardboard template. These represent the
mounting plate’s end holes and bottom edge.
4. Remove the cardboard template and check the markings:
The bottom edge line must be 17¹⁄₄" (43.8 cm) from the
bottom of the upper cabinet, and must be level.
The end holes must be 15³⁄₄" (40.0 cm) from the bottom
edge of the upper cabinet, and must be on a level line with
each other. They must each be 14¹⁄₈" (35.9 cm) from the
centerline.
5. With the support tabs facing forward (see illustrations in
“Locate Wall Stud(s)” section), align the mounting plate center
markers to the centerline on the wall, making sure its bottom
edge is aligned to the horizontal line drawn in Step 3, and that
the end holes are properly marked. Make sure the mounting
plate is level.
6. Holding the mounting plate in place, find the wall stud
centerline(s) drawn in Step 2 of “Locate Wall Stud(s),” and
mark at least 1, preferably 2 hole(s) through the mounting
plate, closest to the wall stud centerline(s). See figures 1, 2
and/or 3 in “Possible Wall Stud Configurations” in “Locate
Wall Stud(s)” section. The blackened holes in the shaded
areas are ideal hole locations.
7. Set the mounting plate aside.
Wall Venting Installation Only
8. Mark the centerline 3/8" (1 cm) down from the bottom edge of
the upper cabinet.
9. Using measuring tape, measure out 6" (15.2 cm) on both sides
of the centerline, and mark.
10. Measure down 4" (10.2 cm) from the mark made in Step 8,
and mark.
11. Using a straightedge, draw the 2 horizontal, level lines through
the marks made in steps 8 and 10.
12. Draw the 2 vertical, plumb lines down from the marks made in
Step 9 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle.
This is the venting cutout area.
13. Cut a 3/4" (19 mm) hole in one corner of the cutout area.
14. Using a keyhole saw, cut out the venting cutout area.
Drill Holes in Rear Wall
In addition to being installed on at least 1 wall stud, the mounting
plate must attach to the wall at both end holes. If the end holes
are not over wall studs, use two 3/16-24 x 2" round-head bolts
with toggle nuts; if 1 end hole is over a wall stud, use 1 lag screw
and one 3/16-24 x 2" round-head bolt with toggle nut; or if both
end holes are over wall studs, use 2 lag screws. Following are 3
installation configurations.
Installation for No Wall Studs at End Holes
(Figures 1 and 2)
1. Drill 5/8" (16 mm) holes through the wall at both end holes
marked in Step 3 of “Mark Rear Wall.”
2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s)
marked in Step 6 of “Mark Rear Wall.” Refer to figures 1 and 2
in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)”
section.
Installation for Wall Stud at One End Hole (Figure 3)
1. Drill a 3/16" (5 mm) hole into the wall stud at the end hole
marked in Step 3 of “Mark Rear Wall.”
2. If installing on a second wall stud, drill a 3/16" (5 mm) hole into
the wall stud at the other hole marked in Step 6 of “Mark Rear
Wall.” Refer to Figure 3 in “Possible Wall Stud Configurations”
in “Locate Wall Stud(s)” section.
3. Drill a 5/8" (16 mm) hole through the wall at the other end hole.
Installation for Wall Studs at Both End Holes (Figure 4)
1. Drill 3/16" (5 mm) holes into the studs at the end holes marked
in Step 3 of “Mark Rear Wall.”
A. Rear wall
B. Cardboard template
C. Top of cardboard template must
align with front edge of cabinet.
D. Front edge of upper cabinet
A
A
C
B
D
Upper cabinet bottom
Bottom of mounting plate
Mounting plate end hole
15³⁄₄"
(40.0 cm)
17¹⁄₄"
(43.8 cm)
14¹⁄₈"
(35.9 cm)
14¹⁄₈"
(35.9 cm)
Centerline
6" (15.2 cm) 6" (15.2 cm)
³⁄₈" (1 cm)
Upper cabinet bottom
4" (10.2 cm)
Centerline
8
Attach Mounting Plate to Wall
NOTE: Secure the mounting plate to the wall at both end holes
drilled into the wall studs and/or drywall using either 3/16-24 x 2"
round-head bolts and toggle nuts or 1/4 x 2" lag screws.
Refer to illustrations in “Possible Wall Stud Configurations” in
“Locate Wall Stud(s)” section.
No Wall Studs at End Holes (Figures 1 and 2)
NOTE: The mounting plate must be secured to the wall on at least
1 wall stud as well as at both ends.
1. With the support tabs of the mounting plate facing forward,
insert 3/16-24 x 2" round-head bolts through both end holes
of mounting plate.
2. Start toggle nuts on bolts from the back of the mounting plate.
Leave enough space for the toggle nuts to go through the wall
and to open.
3. Position mounting plate on the wall.
4. Push the 2 bolts with toggle nuts through the drywall, and
finger tighten the bolts to make sure toggle nuts have opened
against drywall.
5. Insert lag screw(s) into the hole(s) drilled into wall stud(s) in
Step 2 of “Installation for No Wall Studs at End Holes” in the
“Drill Holes in Rear Wall” section.
6. Check alignment of mounting plate, making sure it is level.
7. Securely tighten all lag screws and bolts.
Wall Stud at One End Hole (Figure 3)
1. With the support tabs of the mounting plate facing forward,
insert a 3/16-24 x 2" round-head bolt through the end hole
that fits over the 5/8" (16 mm) hole drilled in Step 3 of
“Installation for Wall Stud at One End Hole” in the “Drill Holes
in Rear Wall” section.
2. Start a toggle nut on the bolt from the back of the mounting
plate. Leave enough space for the toggle nut to go through
the wall and to open.
3. Position mounting plate on the wall.
4. Push the bolt with toggle nut through the drywall, and finger
tighten the bolt to make sure toggle nut has opened against
drywall.
5. Insert a lag screw into the remaining end hole.
6. If installing on a second wall stud, insert a lag screw into the
other hole drilled in Step 2 of “Installation for Wall Stud at One
End Hole” in the “Drill Holes in Rear Wall” section.
7. Check alignment of mounting plate, making sure it is level.
8. Securely tighten the lag screw(s) and bolt.
Wall Studs at Both End Holes (Figure 4)
1. Position mounting plate on the wall.
2. Insert lag screws into both end holes.
3. Check alignment of mounting plate, making sure it is level.
4. Securely tighten the lag screws.
Prepare Upper Cabinet
1. Disconnect power to outlet.
2. Remove all contents from upper cabinet.
3. Place Upper Cabinet Template against the bottom of the
upper cabinet, and attach with tape or thumbtacks. Make sure
the template centerline aligns with the vertical centerline on
the rear wall.
The “rear wall” arrows must be against the rear wall so that the
holes cut into the upper cabinet align with the holes in the top
of the microwave oven.
NOTES:
If the upper cabinet has a frame around it, trim the template
edges so that it fits inside the frame, against the upper cabinet
bottom. The template has trim lines to use as guides.
If the wall behind the microwave oven (as installed) has a
partial wall covering (for example, tile backsplash), be sure the
“Rear Wall” arrows align to the thickest part of the rear wall
(for example, the thickness of the tiles rather than the drywall).
4. Make sure the 10" (25.4 cm) dimension from the rear wall to
points “D” and “E” on the template is maintained.
A. 3/16-24 x 2" round-head bolt
B. Mounting plate
C. Spring toggle nut
A. 3/16-24 x 2" round-head bolt
B. Mounting plate
C. Spring toggle nut
D. Drywall
C
A
B
A
B
C
D
D
E
G
U
p
p
e
r
-
c
a
b
i
ne
t
t
e
m
p
l
a
t
e
F
10"
(25.4 cm)
10"
(25.4 cm)
9
5. Cut the 1¹⁄₂" (3.8 cm) diameter hole at the circular shaded area
“G” on the template. This hole is for the power supply cord.
NOTE: If upper cabinet is metal, the supply cord bushing needs to
be installed around the supply cord hole, as shown.
6. Drill 3/8" (10 mm) holes at points “D” and “E” on the template.
These are for two 1/4-20 x 3" bolts and washers used to
secure the microwave oven to the upper cabinet.
For Roof Venting Installation Only
7. Cut 3/4" (19 mm) hole at one corner of the shaded rectangular
area “F” on Upper Cabinet Template.
8. Using a keyhole saw, cut out the rectangular area.
Install Damper Assembly
(for wall venting only)
1. Check that damper blade moves freely, and opens fully.
2. Position the damper assembly on the back of the microwave
oven so that the damper blade hinge is at the top, and the
damper blade opens away from the microwave oven.
3. Secure damper assembly with 2 sheet metal screws.
Install the Microwave Oven
IMPORTANT: The control side of the microwave oven is the heavy
side. Handle the microwave oven gently.
1. Place a washer on each 1/4-20 x 3" flat-head bolt and place
inside upper cabinet near the 3/8" (10 mm) holes.
2. Make sure the microwave oven door is closed and taped shut.
3. Using 2 or more people, lift microwave oven and hang it on
support tabs at the bottom of mounting plate.
NOTE: To avoid damage to the microwave oven, do not grip or
use the door or door handle while the microwave oven is being
handled.
4. With front of microwave oven still tilted, thread power supply
cord through the power supply cord hole in the bottom of the
upper cabinet.
5. Rotate microwave oven up toward upper cabinet.
NOTE: If venting through the wall, make sure the damper
assembly fits easily into the vent in the wall cutout.
6. Push microwave oven against mounting plate and hold in
place.
A. Metal cabinet
B. Power supply cord bushing
A. Back of microwave oven
B. Damper assembly
C. Damper blade
D. Sheet metal screws
A
B
A B C D
A. Mounting plate
B. Support tabs
WARNING
Excessive Weight Hazard
Use two or more people to move and install
microwave oven.
Failure to do so can result in back or other injury.
A
B
10
NOTE: If microwave oven does not need to be adjusted, skip
steps 7-9.
7. If adjustment is required, rotate microwave oven downward.
Using 2 or more people, lift microwave oven off of mounting
plate, and set aside on a covered surface.
8. Loosen mounting plate screws. Adjust mounting plate and
retighten screws.
9. Repeat steps 3-6.
10. With the microwave oven centered, and with at least one
person holding it in place, insert bolts through upper cabinet
into microwave oven. Tighten bolts until there is no gap
between upper cabinet and microwave oven.
NOTES:
Some upper cabinets may require bolts longer or shorter than
3" (7.6 cm). Longer or shorter bolts are available at most
hardware stores.
Overtightening bolts may warp the top of the microwave oven.
To avoid warping, wood filler blocks (installer to provide)
may be added. The blocks must be the same thickness as
the space between the upper cabinet bottom and the
microwave oven.
A. Bolts
For Roof Venting Installation Only
1. Insert damper assembly through the cabinet cutout so that the
long tab of the damper assembly slides under the raised tabs
of the damper plate. Then secure with sheet metal screw.
NOTE: The screw cannot be installed if the damper assembly is
not positioned as shown.
2. Connect vent to damper assembly.
Complete Installation
1. Install filters. Refer to the User Instructions for filter placement.
2. Plug microwave oven into grounded 3 prong outlet.
3. Reconnect power.
4. Check the operation of microwave oven by placing 1 cup
(250 mL) of water on the turntable, and programming a cook
time of 1 minute at 100% power. Test vent fan and exhaust by
operating the vent fan.
5. If the microwave oven does not operate:
Check that a household fuse has not blown, or that a
circuit breaker has not tripped. Replace the fuse or reset
the circuit breaker. If the problem continues, call an
electrician.
Check that the power supply cord is plugged into a
grounded 3 prong outlet.
See the User Instructions for troubleshooting information.
Installation is now complete.
Save Installation Instructions for future use.
A. Raised tabs
B. Damper assembly
C. Sheet metal screw
D. Upper cabinet cutout
E. Long tab
F. Da mpe r pla te
A
A B C
D E F
A. Vent
B. Damper assembly (under vent)
A B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
11
VENTING DESIGN SPECIFICATIONS
This section is intended for architectural designer and
builder/contractor reference only.
NOTES:
Vent materials needed for installation are not provided with
microwave hood combination.
We do not recommend using a flexible metal vent.
To avoid possible product damage, be sure to vent air outside,
unless using recirculation installation. Do not vent exhaust air
into concealed spaces, such as spaces within walls or
ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
using roof or wall caps that have back draft dampers
using a rigid metal vent
using the most direct route by minimizing the length of the
vent and number of elbows to provide efficient performance
using uniformly sized vents
using duct tape to seal all joints in the vent system
using caulking compound to seal exterior wall or roof opening
around cap
not installing 2 elbows together, for optimal hood performance
If venting through the wall, be sure that there is proper clearance
within the wall for the damper to open fully.
If venting through the roof, and rectangular to round transition is
used, be sure there is at least 3" (7.6 cm) of clearance between
the top of the microwave oven and the transition piece. See
“Rectangular to Round Transition” illustration.
Rectangular to Round Transition
NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round
transition piece so that the damper can open freely and fully.
Recommended Standard Fittings
The following length equivalents are for use when figuring vent
length. See the examples in “Recommended Vent Length.”
Roof venting Roof cap
Wall venting Wall cap
A. Roof cap
B. 6" (15.2 cm) min. diameter round vent
C. Elbow (for wall venting only)
D. Wall cap
E. 3
¹⁄₄
" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
rectangular to round transition piece
F. Vent extension piece, at least 3" (7.6 cm) high
A. Rectangular to round transition piece: 3
¹⁄₄
" x 10" to 6" = 5 ft
(8.3 x 25.4 cm to 15.2 cm = 1.5 m)
B. Roof cap: 3
¹⁄₄
" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)
C. 90° elbow: 3
¹₄
" x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)
E. Wall cap: 3
¹⁄₄
" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)
G. 90° flat elbow: 3
¹⁄₄
" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
A
B
C
E
F
D
3" (7.6 cm)
A B C
D E F G
12
Recommended Vent Length
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent
should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed the
equivalent of 140 ft (42.7 m) for either type of vent. See
“Recommended Standard Fittings” section for equivalent lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent
lengths of each vent piece used in the system. See the following
examples:
3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total
6" (15.2 cm) vent system = 73 ft (22.2 m) total
If the existing vent is round, a rectangular to round transition piece
must be used. In addition, a rectangular 3" (7.6 cm) extension vent
between the damper assembly and rectangular to round transition
piece must be installed to keep the damper from sticking.
ASSISTANCE
Call your authorized dealer or service center. When you call, you
will need the microwave oven model number and serial number.
Both numbers can be found on the model and serial number
plate, which is located behind the microwave oven door on the
front frame of the microwave oven.
If you need additional assistance, call us at our toll free number or
visit our website listed in the User Guide.
Replacement Parts
If any of the installation hardware needs to be replaced, call us at
our toll free number listed in the User Guide.
Following is a list of available replacement parts. You will need
your model number located on the front facing of the microwave
oven opening, behind the door.
Damper Assembly
Mounting Plate
Upper Cabinet Template
Mounting Screw Kit (includes parts A-G in “Parts Supplied” in
the “Tools and Parts” section)
Accessories
Filler Panel Kits are available from your dealer to use when
installing this microwave oven in a 36" (91.4 cm) or 42" (106.7 cm)
wide opening. The filler panels come in pairs. Each panel is 3"
(7.6 cm) wide.
A. Filler panels
See your authorized dealer or service center for details.
A. One 3
¹⁄₄
" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
A B
C
6 ft (1.8 m)
2 ft
(0.6 m)
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
A B
C D
6 ft (1.8 m)
2 ft
(0.6 m)
Filler Panel Kits: 8171336
8171337
8171338
8171339
99403
White
Black
Biscuit
Stainless Steel
Almond
A
13
SÉCURITÉ DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE
EXIGENCES D'INSTALLATION
Outillage et pièces
Outillage nécessaire
Rassembler les outils et pièces nécessaires avant de commencer
l'installation. Lire et suivre les instructions fournies avec les outils
mentionnés ici.
Pièces fournies
Pour la commande de pièces, voir la section “Pièces de
rechange”.
REMARQUE : Les articles de quincaillerie présentés ci-dessous
sont destinés à l'utilisation sur un colombage de bois. En
présence d'une structure de mur différente, utiliser les organes de
fixation appropriés.
REMARQUE : Selon le modèle de l'appareil, le filtre à graisse en
aluminium et le filtre à charbon peuvent être combinés.
Matériaux nécessaires
Composants standard pour décharge à travers le mur ou à
travers le toit. Voir la section “Spécifications/conception du
circuit d'évacuation”.
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Mètre ruban
Crayon
Ruban de masquage ou
punaises
Ciseaux
Tournevis Phillips n° 2
Tournevis Phillips n° 3 (pour
vis de 1/4-20 x 3")
Perceuse
Mèches de 3/16" (5 mm),
3/8" (10 mm) et 5/8"
(16 mm)
Scie-cloche de 3/4" (19 mm)
Pince à coupe diagonale
Détecteur magnétique (des
poteaux de colombage)
Clé à douille de 7/16" (ou
clé polygonale), pour vis
d'ancrage de 1/4" x 2"
Foret de 1½" (3,8 cm) de
diamètre pour placard de
bois ou métallique
Scie à guichet
Pistolet à calfeutrage et
composé de calfeutrage
résistant aux intempéries
Ruban adhésif pour
conduit
A. Vis à tête ronde de 3/16-24 x 2" (2)
B. Vis à tête plate de 1/4-20 x 3" (2)
C. Rondelles (2)
D. Écrous articulés de 3/16" (2)
E. Vis d'ancrage de 1/4" x 2" (2)
F. Vis de tôlerie (2)
G. Garniture pour trou de passage du
cordon d'alimentation (1)
H. Module de clapet anti-reflux (pour
décharge à travers le mur ou le toit)
Composants non illustrés :
Gabarit pour placard
supérieur (mural)
Plaque de montage (fixation
à l'arrière du four à micro-
ondes)
Gabarit de carton (fait partie
de l’emballage)
Filtres à graisse en aluminium
Filtres à charbon (selon le
modèle, les filtres à charbon
peuvent ne pas être inclus.
Voir les Instructions
d’utilisation.)
A
B
C
D
EF
G
H
14
Dépose du gabarit de carton
Le morceau de carton du dessus de l'emballage du four à micro-
ondes est perforé. La partie à l'intérieur des trous de perforation
est à utiliser comme gabarit de mur arrière.
1. Découper le long des trous perforés pour détacher le gabarit
du reste de l'emballage de carton.
2. Mettre le gabarit de carton de côté et s'y référer lors de l'étape
d'installation “Tracé sur le mur arrière”.
Exigences d'emplacement
Inspecter l'espace où le four à micro-ondes sera installé.
L'emplacement d'installation doit disposer de :
Dimensions minimales à respecter lors de l’installation. Voir
l’illustration “Dimensions à respecter lors de l’installation”.
Au moins un poteau de colombage en bois 2" x 4"
(50,8 x 101,6 mm), et parement de plâtre ou panneau de
gypse d'épaisseur 3/8" (10 mm) ou plus, dans l'ouverture du
placard.
Capacité de support de charge de 150 lb (68 kg), ceci incluant
le four à micro-ondes et les articles placés à l'intérieur du four
à micro-ondes et du placard supérieur.
Prise de courant électrique reliée à la terre à l'intérieur du
placard supérieur. Voir la section “Spécifications électriques”.
REMARQUES :
Dans le cas de l'installation du four à micro-ondes à proximité
d'une paroi latérale sur le côté gauche, veiller à laisser un
espace libre de 6" (15,2 cm) ou plus entre le mur et le four à
micro-ondes, pour permettre la manœuvre d'ouverture
complète de la porte.
Les matériaux de certains placards et certains matériaux de
construction ne sont pas conçus pour résister à la chaleur
émise par le four à micro-ondes lors des opérations de
cuisson. Consulter le constructeur de la maison ou le fabricant
des placards pour déterminer si les matériaux utilisés
pourraient subir un changement de couleur, une
déstratification ou d'autres dommages.
Exigences spéciales
Pour une installation avec décharge murale seulement :
L'ouverture découpée doit être exempte d'obstruction pour
l'ajustement adéquat du conduit, et pour que le clapet anti-
reflux puisse manœuvrer complètement et librement.
Pour une installation avec décharge à l'extérieur à travers
le toit seulement :
Si l’on utilise un raccord de transition rectangulaire/rond, on
doit disposer d'un espace libre de 3" (7,6 cm) au-dessus du
four à micro-ondes pour que la lame du clapet anti-reflux
puisse manœuvrer complètement et librement. Voir
l'illustration “Raccord de transition rectangulaire/rond” à la
section “Spécifications/conception du circuit d’évacuation”.
Dimensions à respecter lors de l'installation
REMARQUE : La prise de courant à 3 alvéoles reliée à la terre doit
être située à l'intérieur du placard supérieur. Voir la section
“Spécifications électriques”.
*30" (76,2 cm) est typique pour une hauteur d’installation de 66"
(167,6 cm). Les dimensions exactes peuvent varier en fonction
du type de cuisinière/table de cuisson se trouvant en-dessous.
Dimensions du produit
*La profondeur totale du produit varie légèrement selon la
conception de la porte.
A. Poteau du colombage mural de 2" x 4"
B. Prise à 3 alvéoles reliée à la terre
12" (30,5 cm) min.
14" (35,6 cm) max.
30"
(76,2 cm)
min.
A B
30"
(76,2 cm)
typique*
66" (167,6 cm) min.
profondeur du
placard supérieur et
du placard latéral
29
⁷⁄₈
" (76,0 cm)
16
¹⁄₄
"
(41,3 cm)
Jusqu'à
16
³⁄₄
"
(42,5 cm)*
17
¹⁄₈
"
(43,5 cm)
+/-
³⁄₁₆
"
(0,5 cm)
15
Spécifications électriques
Observer les dispositions de tous les codes et règlements en
vigueur.
Nécessaire :
Une alimentation électrique de 120 volts, 60 Hz, CA
seulement, 15 ou 20 ampères, protégée par un fusible ou un
disjoncteur.
Recommandé :
Un fusible temporisé ou un disjoncteur temporisé.
Un circuit distinct exclusif à ce four à micro-ondes.
INSTRUCTIONS D'INSTALLATION
Dépose de la plaque de montage
Selon votre modèle, la plaque de montage peut se trouver soit
dans l’emballage en mousse, soit fixée à l’arrière du four à
micro-ondes.
REMARQUE : Couvrir la surface de travail pour éviter de
l’endommager.
1. Retirer de la cavité du four à micro-ondes tous les articles qui
peuvent s'y trouver.
2. Si la plaque de montage est fixée sur la partie arrière du four à
micro-ondes, la retirer et la mettre de côté.
3. Utiliser du ruban adhésif pour immobiliser la porte fermée du
four à micro-ondes afin qu'elle ne puisse pas s'ouvrir durant la
manipulation du four.
REMARQUE : Pour éviter d’endommager le four à micro-ondes,
ne pas prendre prise sur la porte ou la poignée de la porte durant
la manipulation du four à micro-ondes.
Réorientation du moteur du ventilateur
Le four à micro-ondes a été configuré à l'usine pour une
installation avec recyclage de l’air. Pour la décharge de l'air aspiré
à travers le mur ou à travers le toit, on doit modifier le système de
ventilation du four.
REMARQUE : Si le produit est destiné à être utilisé avec
recyclage de l'air, ne pas tenir compte de cette section. Conserver
le module du clapet pour le cas où une autre méthode
d'évacuation serait utilisée ultérieurement ou dans le cas où le
four à micro-ondes serait réinstallé ultérieurement en un autre
endroit, avec décharge à l'extérieur à travers le mur ou à travers le
toit.
Pour une installation avec décharge murale seulement
1. Ôter les vis fixant la plaque de support du clapet anti-reflux à
la partie supérieure de l'extérieur du four à micro-ondes. Faire
glisser la plaque de support du clapet anti-reflux vers l'avant
du four à micro-ondes et la soulever.
AVERTISSEMENT
Risque de choc électrique
Brancher sur une prise à 3 alvéoles reliée à la terre.
Ne pas enlever la broche de liaison à la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un câble de rallonge.
Le non-respect de ces instructions peut causer
un décès, un incendie ou un choc électrique.
INSTRUCTIONS DE LIAISON
À LA TERRE
CONSERVEZ CES
INSTRUCTIONS
Pour tout appareil ménager connecté par un cordon
de courant électrique :
Il faut que le four à micro-ondes soit relié à la terre. En
cas de court-circuit électrique, la liaison à la terre réduit le
risque de choc électrique car le courant électrique
dispose d’un itinéraire direct d’acheminement à la terre.
Le four à micro-ondes est doté d’un cordon de courant
électrique qui comporte un fil de liaison à la terre, avec
broche de liaison à la terre. On doit brancher la fiche sur
une prise de courant convenablement installée et reliée à
la terre.
AVERTISSEMENT : L’utilisation incorrecte du
dispositif de liaison à la terre peut susciter un risque de choc
électrique. L’utilisateur qui ne comprend pas bien les
instructions de liaison à la terre, ou qui n’est pas certain que
le four à micro-ondes soit convenablement relié à la terre,
devrait consulter un électricien ou un technicien qualifié.
Ne pas utiliser un câble de rallonge. Si le cordon de
courant électrique est trop court, demander à un électricien
ou un technicien qualifié d’installer une prise de courant à
proximité du four à micro-ondes.
A. Vis
B. Plaque de support du clapet
A
B
16
2. Conserver ensemble la plaque de support du clapet et les vis;
les mettre de côté.
3. Retirer les 2 vis fixant le moteur du ventilateur à l'arrière du
four à micro-ondes.
A. Vis (dans les trous décalés)
4. Soulever le moteur du ventilateur pour le sortir du four à
micro-ondes.
A. Moteur du ventilateur
5. Faire pivoter le moteur du ventilateur de 180° pour que les
orifices de sortie soient alignés avec l'arrière du four à micro-
ondes, et rabaisser le moteur du ventilateur dans le four à
micro-ondes.
A. Orifice de sortie
6. À l’aide d’une pince à coupe diagonale, découper doucement
au niveau des perforations des couvercles rectangulaires de
fermeture du clapet.
7. Fixer à nouveau le moteur du ventilateur à l'arrière du four à
micro-ondes avec les 2 vis ôtées à l'étape 3.
8. Fixer à nouveau la plaque de support du clapet. Vérifier que
les onglets de la plaque de support du clapet sont insérés
dans les fentes situées sur la partie supérieure du four à
micro-ondes.
9. Fixer la plaque de support du clapet à l'aide des 2 vis qui ont
été retirées à l'étape 1.
Pour une installation avec décharge à l'extérieur à
travers le toit seulement
1. Répéter l'étape 1 de “Pour une installation avec décharge
murale seulement”.
2. Répéter l'étape 2 de “Pour une installation avec décharge
murale seulement”.
3. Répéter l'étape 3 de “Pour une installation avec décharge
murale seulement”.
4. Répéter l'étape 4 de “Pour une installation avec décharge
murale seulement”.
5. Faire pivoter le moteur du ventilateur pour que les orifices de
sortie soient orientés vers le haut du four à micro-ondes, et
que les côtés plats du moteur du ventilateur soient orientés
vers l'arrière du four à micro-ondes. Rabaisser le moteur du
ventilateur dans le four à micro-ondes.
A. Orifice de sortie
IMPORTANT : Si le moteur du ventilateur n'est pas positionné
avec les côtés plats orientés vers l'arrière du four à micro-ondes
(tel qu'illustré), le rendement sera médiocre.
6. Fixer à nouveau le moteur du ventilateur à l'arrière du four à
micro-ondes avec les 2 vis ôtées à l'étape 3 de la section
“Pour une installation avec décharge murale seulement”. Bien
serrer les vis.
REMARQUE : Si le moteur du ventilateur n'est pas correctement
orienté, les 2 vis ôtées à l'étape 3 ne peuvent pas être réinstallées
sur le four à micro-ondes.
A. Pince à coupe diagonale
B. Couvercles de fermeture du clapet
A
A
A
B
A
A. Plaque de support du clapet
B. Vis
C. Onglets de la plaque de support du clapet
D. Fentes
A
B
C
D
17
7. À l’aide d’une pince à coupe diagonale, découper doucement
au niveau des perforations des couvercles rectangulaires sur
la plaque de support du clapet ôtée à l’étape 1.
8. Fixer à nouveau la plaque de support du clapet. Vérifier que
les onglets de la plaque de support du clapet sont insérés
dans les fentes situées sur la partie supérieure du four à
micro-ondes.
9. Fixer la plaque de support du clapet à l'aide des 2 vis qui ont
été retirées à l'étape 1 de la section “Pour une installation
avec décharge murale seulement”.
Identifier la position du/des poteau(x) du colombage mural
REMARQUE : S'il n'y a aucun poteau du colombage mural dans
la zone délimitée par l'ouverture dans le placard supérieur, ne pas
installer le four à micro-ondes.
Voir les illustrations à la section “Configurations possibles du
colombage mural”.
1. Utiliser un détecteur magnétique pour localiser dans
l'ouverture les rives du/des poteau(x) du colombage mural.
2. Marquer la position du centre de chaque poteau du
colombage, et tracer l'axe de chaque poteau à l'aide d'un fil à
plomb. Voir les illustrations à la section “Configurations
possibles du colombage mural”.
Configurations possibles du colombage mural
Les illustrations ci-dessous présentent des exemples de configurations préférées d'installation avec la plaque de montage.
A. Pince à coupe diagonale
B. Couvercles rectangulaires de la plaque de support du clapet
B
A
A. Plaque de support du clapet
B. Vis
C. Onglets de la plaque de support du clapet
D. Fentes
A
B
C
D
Aucun poteau du colombage à la position des trous d’angle
Figure 1
Aucun poteau du colombage à la position des trous d’angle
Figure 2
REMARQUE : Si le poteau de colombage mural se trouve à 6"
(15,2 cm) ou moins de l’axe central vertical (voir la section
“Tracé sur le mur arrière”), seule une installation sans décharge
à l'extérieur (recyclage) ou une installation avec décharge par
le toit peut être réalisée.
Un trou d’angle face à un poteau du colombage mural
Figure 3
Deux trous d’angle face à des poteaux du colombage mural
Figure 4
A. Trous d’angle (sur la plaque de montage)
B. Axe vertical central de l'ouverture dans le placard
C. Axes centraux de poteau du colombage
D. Trous pour vis d’ancrage
E. Pattes de support
F. Repères centraux sur la plaque de montage
A
A
B
C
C
D
E
E
F
A
A
B
C
D
E
E
F
A
A,D
B
C
C
D
E
E
F
A,D
B
E
A,D
C
E
C
F
18
Tracé sur le mur arrière
Le four à micro-ondes doit être fixé sur au moins un poteau du
colombage mural, et de préférence sur 2 poteaux; on utilise pour
cela au moins 1 vis d'ancrage, et de préférence 2 vis.
1. Utiliser un mètre ruban; déterminer et marquer clairement la
position de l'axe central vertical de l'ouverture.
A. Axe central
2. Aligner les repères centraux sur le gabarit de carton (couvercle
supérieur du carton) avec l'axe central sur le mur; veiller au
bon aplomb, et veiller à ce que le sommet du gabarit de
carton soit en contact avec le bord inférieur du placard
supérieur.
REMARQUES :
Si la rive avant du placard supérieur est plus basse que la rive
arrière, abaisser le gabarit de carton de manière à ce que son
sommet soit au même niveau que la rive avant du placard.
Si le gabarit de carton est endommagé ou inutilisable,
mesurer et inscrire les dimensions indiquées à l'étape 4 sur
le mur.
3. Tout en maintenant le gabarit de carton en place, marquer
l'emplacement des deux trous situés dans les coins inférieurs
et tracer un axe horizontal en travers de la rive inférieure du
gabarit de carton. Ces marquages représentent les trous
d'angle de la plaque de montage ainsi que la rive inférieure.
4. Ôter le gabarit de carton et vérifier les points de tracé :
L'axe de la rive inférieure doit être situé à 17¹⁄₄" (43,8 cm)
de la partie inférieure du placard supérieur et doit être
d'aplomb.
Les trous d'angle doivent être situés à 15³⁄₄" (40,0 cm) de
la rive inférieure du placard supérieur et doivent être
alignés les uns avec les autres. Chacun doit être situé à
14¹⁄₈" (35,9 cm) de l'axe central.
5. Une fois les brides de support orientées vers l'avant (voir les
illustrations de la section “Identification de la position du/des
poteau(x) du colombage mural”), aligner le tracé du centre de
la plaque de montage avec l'axe central sur le mur, en
s'assurant que sa rive inférieure est alignée avec l'axe
horizontal tracé à l'étape 3 et que les trous d'angle sont
correctement indiqués. S'assurer que la plaque de montage
est d'aplomb.
6. Tout en maintenant la plaque de montage en place, trouver
l'axe central/les axes centraux des poteaux du colombage
marqué(s) à l'étape 2 de la section “Identification de la
position du/des poteau(x) du colombage mural”, et marquer la
position d'au moins 1, et de préférence 2, trou(s) à travers la
plaque de montage - le plus près possible de l'axe central/des
axes centraux de chaque poteau du colombage. Voir les
figures 1, 2 et/ou 3 de la section “Configurations possibles du
colombage mural” à la section “Identification de la position
du/des poteau(x) du colombage mural”. Les trous à utiliser de
préférence sont ceux qui sont marqués en noir dans les zones
grisées.
7. Conserver la plaque de montage à part.
Pour une installation avec décharge murale seulement
8. Marquer un point sur l'axe central à 3/8" (1 cm) au-dessous de
la rive inférieure du placard supérieur.
9. Utiliser un mètre ruban; marquer un point à 6" (15,2 cm) de
chaque côté de l'axe central.
10. Marquer un point à 4" (10,2 cm) au-dessous de la marque
tracée à l'étape 8.
11. Utiliser une règle; tracer 2 lignes horizontales entre les
marques tracées aux étapes 8 et 10.
12. Tracer 2 lignes verticales à partir des marques faites à
l'étape 9 à l’aide d’un fil à plomb pour obtenir un rectangle
complet de 12" x 4" (30,5 x 10,2 cm). Ce rectangle délimite la
zone à découper pour le passage du conduit d'évacuation.
13. Découper un trou de 3/4" (19 mm) dans un coin de la zone à
découper.
14. À l’aide d’une scie à guichet, découper la zone à découper
pour le passage du conduit d’évacuation.
A. Mur arrière
B. Gabarit de carton
C. Le sommet du gabarit de carton doit être
aligné avec la rive avant du placard.
D. Rive avant du placard supérieur
A
A
C
B
D
Fond du placard supérieur
Partie inférieure de
la plaque de montage
Trou d'angle de la plaque de montage
15³⁄₄"
(40,0 cm)
17¹⁄₄"
(43,8 cm)
14¹⁄₈"
(35,9 cm)
14¹⁄₈"
(35,9 cm)
Axe central
6" (15,2 cm) 6" (15,2 cm)
³⁄₈" (1 cm)
Fond du placard supérieur
4" (10,2 cm)
Axe central
19
Perçage de trous dans le mur arrière
En plus de la fixation sur au moins un poteau du colombage, on
doit également fixer la plaque de montage sur le mur au niveau
des deux trous d’angle. Si la position des trous d’angle ne
coïncide pas avec celle des poteaux du colombage mural, utiliser
deux vis à tête ronde de 3/16-24 x 2" avec écrou articulé; s'il y a
un trou d’angle en coïncidence avec le poteau de colombage,
utiliser une vis d'ancrage et une vis à tête ronde de 3/16-24 x 2"
avec écrou articulé; si les deux trous coïncident avec les poteaux
de colombage mural, utiliser deux vis d'ancrage. On présente ci-
dessous 3 configurations d'installation.
Aucun poteau du colombage à la position des trous
d’angle (Figures 1 et 2)
1. Percer des trous de 5/8" (16 mm) à travers le mur à
l'emplacement des deux trous d'angle marqués à l'étape 3 de
la section “Tracé sur le mur arrière”.
2. Percer un ou plusieurs trous de 3/16" (5 mm) dans le(s)
poteau(x) de colombage mural à l'emplacement du/des trou(s)
d'angle marqué(s) à l'étape 6 de la section “Tracé sur le mur
arrière”. Voir les figures 1 et 2 du paragraphe “Configurations
possibles du colombage mural” à la section “Identification de
la position du/des poteau(x) du colombage mural”.
Poteau du colombage mural à un trou d’angle (Figure 3)
1. Percer un trou de 3/16" (5 mm) à travers le poteau de
colombage mural à l'emplacement du trou d'angle marqué à
l'étape 3 dans “Tracé sur le mur arrière”.
2. Si l'on souhaite fixer l'appareil sur un second poteau du
colombage mural, percer un trou de 3/16" (5 mm) dans le
poteau du colombage mural à l'emplacement de l'autre trou
marqué à l'étape 6 dans “Tracé sur le mur arrière”. Voir la
figure 3 dans le paragraphe “Configurations possibles du
colombage mural” à la section “Identification de la position
du/des poteau(x) du colombage mural”.
3. Percer un trou de 5/8" (16 mm) à travers le mur au niveau de
l'autre trou d'angle.
Poteaux du colombage mural aux deux trous d’angle
(Figure 4)
1. Percer des trous de 3/16" (5 mm) à travers les poteaux du
colombage mural à l'emplacement des trous d’angle marqués
à l'étape 3 dans “Tracé sur le mur arrière”.
Fixation de la plaque de montage sur
le mur
REMARQUE : Fixer la plaque de montage sur le mur, dans les
deux trous d’angle percés dans les poteaux du colombage et/ou
à travers le panneau de gypse à l’aide de vis à tête ronde de 3/16-
24 x 2" avec écrou articulé ou vis d'ancrage de 1/4 x 2".
Voir les illustrations du paragraphe “Configurations possibles du
colombage mural” à la section “Identification de la position
du/des poteau(x) du colombage mural”.
Aucun poteau du colombage à la position des trous
d’angle (Figures 1 et 2)
REMARQUE : La plaque de montage doit être fixée sur le mur et
sur au moins un poteau de colombage, ainsi qu'aux deux angles.
1. Alors que les pattes de support de la plaque de montage sont
orientées vers l'avant, insérer des vis à tête ronde de 3/16-24
x 2" dans les deux trous d’angle de la plaque de montage.
2. Engager un écrou articulé sur chaque vis par l'arrière de la
plaque de montage. Veiller à disposer de suffisamment
d'espace pour que les écrous articulés puissent traverser le
panneau de gypse et se déployer à l'intérieur de la cavité
murale.
3. Positionner la plaque de montage sur le mur.
4. Pousser les deux vis avec écrou articulé à travers le panneau
de gypse; visser les vis à la main pour vérifier que chaque
écrou articulé s'est déployé et prend appui contre le panneau
de gypse.
5. Insérer la/les vis d'ancrage dans le/les trou(s) percé(s) dans
le(s) poteau(x) de colombage mural à l'étape 2 du paragraphe
“Aucun poteau du colombage à la position des trous d’angle”
de la section “Perçage des trous dans le mur arrière”.
6. Contrôler l'alignement de la plaque de montage; veiller à
établir un bon aplomb.
7. Serrer solidement toutes les pièces d’ancrage (vis et boulons).
A. Vis à tête ronde de 3/16-24 x 2"
B. Plaque de montage
C. Écrou articulé à ressort
A. Vis à tête ronde de 3/16-24 x 2"
B. Plaque de montage
C. Écrou articulé à ressort
D. Panneau de gypse
C
A
B
A
B
C
D
20
Poteau du colombage mural à un trou d’angle (Figure 3)
1. Alors que les pattes de support de la plaque de montage sont
orientées vers l'avant, insérer une vis à tête ronde de 3/16-24
x 2" dans le trou d'angle coïncidant avec le trou de 5/8"
(16 mm) percé à l'étape 3 du paragraphe “Poteau du
colombage mural à un trou d’angle” de la section “Perçage
des trous dans le mur arrière”.
2. Engager un écrou articulé sur la vis par l'arrière de la plaque
de montage. Veiller à disposer de suffisamment d'espace
pour que l'écrou articulé puisse traverser le panneau de gypse
et se déployer à l'intérieur de la cavité murale.
3. Positionner la plaque de montage sur le mur.
4. Pousser la vis avec écrou articulé à travers le panneau de
gypse; visser la vis à la main pour vérifier que chaque écrou
articulé s'est déployé et prend appui contre le panneau de
gypse.
5. Insérer une vis d'ancrage dans le trou d'angle restant.
6. Si l'on souhaite fixer également l'appareil sur un second
poteau du colombage mural, insérer une vis d'ancrage dans
l'autre trou percé à l'étape 2 du paragraphe “Poteau du
colombage mural à un trou d’angle” de la section “Perçage
des trous dans le mur arrière”.
7. Contrôler l'alignement de la plaque de montage; veiller à
établir un bon aplomb.
8. Serrer solidement la/les vis d'ancrage et le boulon.
Poteaux du colombage mural aux deux trous d’angle
(Figure 4)
1. Positionner la plaque de montage sur le mur.
2. Insérer les vis d'ancrage dans les deux trous d’angle.
3. Contrôler l'alignement de la plaque de montage; veiller à
établir un bon aplomb.
4. Serrer solidement les vis d'ancrage.
Préparation du placard supérieur
1. Interrompre l'alimentation électrique.
2. Retirer tout le contenu du placard supérieur.
3. Placer le gabarit du placard supérieur contre le fond du
placard supérieur, et le fixer avec du ruban adhésif ou des
punaises. Veiller à aligner l'axe central du gabarit avec l'axe
vertical central tracé sur le mur arrière.
Les flèches correspondant au mur arrière doivent être contre
le mur arrière, pour qu'on puisse obtenir l'alignement des
trous découpés dans le placard supérieur avec les trous
situés au sommet du four à micro-ondes.
REMARQUES :
Si le placard supérieur comporte un cadre périmétrique, tailler
les bords du gabarit de telle manière qu'il puisse s'ajuster
dans le cadre, contre le fond du placard supérieur. Le gabarit
comporte des lignes de découpe qu'on peut utiliser comme
guides.
Si le mur situé derrière le micro-ondes comporte un
revêtement mural partiel (par exemple, un dosseret à
carreaux), s’assurer que les flèches correspondant au mur
arrière s’alignent avec la partie la plus épaisse du mur arrière
(par exemple, l’épaisseur des carreaux plutôt que le panneau
de gypse).
4. Veiller à laisser un espace de 10" (25,4 cm) entre le mur
arrière et les points “D” et “E” sur le gabarit.
5. Percer le trou de diamètre 1½" (3,8 cm) dans la zone circulaire
grisée “G” du gabarit. Ce trou est utilisé pour le passage du
cordon d'alimentation.
REMARQUE : Si le placard supérieur est métallique, la bague de
cordon d’alimentation nécessite d’être installée autour du trou de
passage du cordon d’alimentation – voir l’illustration.
6. Percer des trous de 3/8" (10 mm) aux points “D” et “E” du
gabarit. Ces trous sont utilisés pour le passage de deux vis de
1/4-20 x 3" avec rondelle, utilisées pour la fixation du four à
micro-ondes contre le placard supérieur.
Pour une installation avec décharge à l’extérieur à
travers le toit seulement
7. Découper un trou de 3/4" (19 mm) dans un coin de la zone
ombrée rectangulaire “F” sur le gabarit du placard supérieur.
8. À l’aide d’une scie à guichet, découper la zone rectangulaire.
A. Placard métallique
B. Garniture du trou de passage du cordon d'alimentation
G
F
10"
(25,4 cm)
10"
(25,4 cm)
Ga
ba
rit
du
pl
acar
d m
ur
al
D
E
A
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

KitchenAid YMMV6190FZ1 Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues