MLC Plus 84 EU and MLC Plus 84 MK • Setup Guide (Continued)
Reset Modes: a Brief Summary
The MLC Plus 84 Series controllers offer the following reset modes:
• Use Factory Firmware: Press and hold the rear panel Reset button while applying power to the unit. Keep holding
the button down until the Reset LED blinks twice, or for 6 seconds, then release the button.
The control processor enters factory firmware mode. For units with firmware prior to version
2.00.0001, the LED blinks quickly. Use this mode to revert to factory firmware in the event of a
firmware failure.
Do not continue to operate the controller using the factory rmware version. If you want to use
the factory default rmware version, you must upload that version again.
• Project Recovery: See the MLC Plus 84 Series User Guide for instructions. Use this mode to recover the project in
the event of a lost user name and password.
• Run/Stop Program: Hold down the Reset button for about 3 seconds, until the Reset LED blinks once. Release
and press the Reset button momentarily (for <1second) within 1second. (Nothing happens if
the momentary press does not occur within 1second.) The LED blinks 2 times if the program is
starting. The LED blinks 3 times if the program is stopping. This mode allows you to restart any
scripts or events stopped by an IP settings reset.
• Toggle DHCP Client: Press the Reset button five times (consecutively). Release the button. Do not press the button
within 3seconds following the fifth press. Use this mode to enable or disable the DHCP client
for the LAN port.
• The Reset LED blinks 6 times if the DHCP client is enabled.
• The Reset LED blinks 3 times if the DHCP client is disabled.
NOTES:
• DHCP toggle mode is supported on firmware version 3.00.0000 or higher.
• By default DHCP is off and the unit uses a static IP address.
• When you disable DHCP, the unit uses the previous static IP address.
• Reset All IP Settings: Press and hold the rear panel Reset button for 6 seconds. After the Reset LED blinks twice,
release and momentarily press the Reset button. Use this mode to reset all network settings
to factory default values without affecting user-loaded files. This reset mode also stops any
running scripts and events.
• Reset to Factory Defaults: Press and hold the rear panel Reset button for 9 seconds. After the Reset LED blinks three
times, release and momentarily press the Reset button within 1 second. Use this mode to
return the controller to factory default settings. This mode also deletes all user-loaded files and
configurations.
For detailed information on each mode and its use, see the MLC Plus 84 Series User Guide at www.extron.com.
Resources
Obtaining Control Drivers
Extron provides an extensive selection of device
drivers available on the Extron website. If the
system requires a control driver that is not already
available, you can request a new serial (RS-232) or
Ethernet driver from Extron.
Obtaining Instructions, Information, and Assistance
A checklist of basic setup steps is provided in this guide. For
additional information see the help files and the MLCPlus84Series
User Guide, available at www.extron.com.
If you have questions during installation and setup, call the ExtronS3
Sales & Technical Support Hotline or the ExtronS3 Control
Systems Support Hotline (1.800.633.9877).
Rev. C, 08/2018: Changed wording of various items in the
reset modes summary:
For the Use Factory Firmware mode, added more text to
clarify how long to hold the button, and on LED behavior
for units with versions prior to 2.x.
Per peer reviewer (Sean), added (for IPCP guides) “
Do
not continue to operate the control processor using
the factory firmware version. If you want to use the
factory default firmware version, you must upload
that version again.
“
Added Run/Stop Program mode and DHCP toggle mode.
For the Reset All IP Settings mode, noted that the mode
stops running scripts/events.
For the Reset to Factory Defaults mode, noted that the
reset deletes user-loaded files and configs.
Rev. D: corrected
behavior when DHCP
is disabled from using
the firmware default
IP address to using
the previous static IP
address.
Rev. C, 09/2018: Removed the
“About Global Configurator (with
GC Professional and GC Plus
Modes)” section (as has been done
in the IPL Pro and IPCP Pro setup
guides), which isn’t needed here
and is partially redundant with text
earlier in this guide.