Installation Preparation - Electrical Supply
PREPARE ELECTRICAL WIRING
FOR PERSONAL SAFETY: Remove house fuse
or open circuit breaker before beginning
installation. Do not use an extension cord or
adapter plug with this appliance.
PARA SEGURIDAD PERSONAL: Retire el
fusible de la casa o abra el interruptor de
circuitos antes de empezar la instolaci6n.
No use un cable de extensi6n o enchufe
adaptador con este aparato.
Electrical Requirements
• This appliance must be supplied with 120V, 60 Hz.,
and connected to an individual properlg grounded
branch circuit, protected bg a 15- or 20-ampere
circuit breaker or time-delag fuse.
• Wiring must be 2 wire with ground.
• If the electrical supplg does not meet the above
requirements, call a licensed electrician before
proceeding.
Grounding Instructions - Permanent Connection
This appliance must be connected to a grounded-
metal, permanent wiring sgstem, or an equipment-
grounding conductor must be run with the circuit
conductors and be connected to the equipment-
grounding terminal or lead on the appliance.
Grounding Instructions - Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce
the risk of electric shock bg providing a path of
least resistance for electric current. This appliance
is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug
must be plugged into an appropriate outlet that is
installed and grounded in accordance with all local
codes and ordinances.
The improper connection of the equipment-
grounding conductor can result in electric
shock. Check with a qualified electrician or
service representative if gou are in doubt that
the appliance is properlg grounded,
Do not modifg the plug provided with the
appliance; if it will not fit the outlet° have
a proper outlet installed bg a qualified
technician.
_La conexi6n incorrecta del conductor
de conexi6n a tierra del equipo puede
resuitar en choque el_ctrico. Consulte con
un electricista calificado o representante
de servicio si tiene dudas de la conexi6n
a tierra del aparato. No modifique el
enchufe qua se suministra con el aparato;
si no colza en el tomacorrientes0 haga
qua un t_cnico calificado le instale un
tomacorrientes adecuado.
,,f- Alternate ]'\
// I
I Receptacle ij \\
_,, " Location
Cabinet
Figure E
White
Cabinet Preparation and Wire Routing
, The wiring mag enter the opening from either side,
rear or floor within the shaded area illustrated
above in Figure Eand defined in Figure A.
• Cut a 2-1/2" maximum diameter hole to insert the
electrical cable. Permanent wiring connections
mag pass through the same hole as the drain
hose and hot water line, if convenient. Hole edges
must be smooth and rounded, if the cabinet wall is
metal, the hole edge must be covered with a cord
protector.
NOTE: Power cords with plug must pass through a
separate hole.
Protector
(Provided
with Power
Cord Hodels Onlg)
Hole Diameter
1-1/2" Haximum
Electrical Connection to Dishwasher
Electrical connection is on the right front of
dishwasher.
, For permanent connections, the cable must be
routed as shown in Figure E.The cable must extend
a minimum of 24" from the rear wall.
, For power cord connections, install a 3-prong
grounding-tgpe receptacle in the adjacent cabinet
rear wall, between 6" and 18" from the opening, 6"
to 18" above the floor as shown in Figure E.
5