Stahl 8570 Mode d'emploi

Taper
Mode d'emploi
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
North American
operating instructions
Additional languages r-stahl.com
US
SolConeX
Receptacle, 20 A
Series 8570/21
– Save for future use! –
2
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Contents
1 General Information ............................................................................................3
1.1 Manufacturer .......................................................................................................3
1.2 Information regarding the Operating Instructions ................................................3
1.3 Further Documents .............................................................................................3
1.4 Conformity with Standards and Regulations .......................................................3
2 Explanation of the Symbols ................................................................................4
2.1 Symbols in these Operating Instructions ............................................................4
2.2 Warning Notes ....................................................................................................4
2.3 Symbols on the Device .......................................................................................5
3 Safety Notes .......................................................................................................5
3.1 Operating Instructions Storage ...........................................................................5
3.2 Personnel Qualification .......................................................................................5
3.3 Safe Use .............................................................................................................6
3.4 Specific Conditions of Use ..................................................................................7
3.5 Modifications and Alterations ..............................................................................7
4 Function and Device Design ...............................................................................7
4.1 Function ..............................................................................................................7
5 Technical Data ....................................................................................................8
6 Transport and Storage ......................................................................................19
7 Mounting and Installation ..................................................................................19
7.1 Dimensions / Fastening Dimensions .................................................................19
7.2 Mounting / Dismounting, Operating Position .....................................................20
7.3 Installation .........................................................................................................21
8 Commissioning .................................................................................................24
9 Operation ..........................................................................................................24
10 Maintenance, Overhaul, Repair ........................................................................25
10.1 Maintenance .....................................................................................................25
10.2 Overhaul ...........................................................................................................25
10.3 Repair ...............................................................................................................25
10.4 Returning the Device ........................................................................................26
11 Cleaning ............................................................................................................26
12 Disposal ............................................................................................................26
13 Accessories and Spare Parts ............................................................................26
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
General Information
3
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
1 General Information
1.1 Manufacturer
1.2 Information regarding the Operating Instructions
ID-No.: 287620 / 8570674300
Publication Code: 2022‐03‐28·IO00·III·en·00
The original instructions are the US-American edition.
They are legally binding in all legal affairs.
1.3 Further Documents
SolConeX plug and socket devices data sheet
Mounting instructions for auxiliary contacts
For documents in additional languages, see r-stahl.com.
1.4 Conformity with Standards and Regulations
Certificates for the USA and Canada can be downloaded via the following link:
https://r-stahl.com/en/global/support/downloads..
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 Waldenburg
Germany
R. STAHL, INC.
13259 N. Promenade Blvd.
Stafford, TX 77477
USA
Phone:
Fax:
Internet:
E-mail:
+49 7942 943-0
+49 7942 943-4333
r-stahl.com
Phone:
Fax:
Internet:
E-mail:
+1 800 782-4357
+1 281 313-9302
r-stahl.com
R. STAHL Ltd.
#303, 8925-51 Avenue
Edmonton, AB T6E 5J3
Canada
Phone:
Fax:
Internet:
E-mail:
+1 877 416 4302
+1 780 469 5525
r-stahl.com
Explanation of the Symbols
4287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
2 Explanation of the Symbols
2.1 Symbols in these Operating Instructions
2.2 Warning Notes
Warnings must be observed under all circumstances, in order to minimize the risk due to
construction and operation. The warning notes have the following structure:
Signalling word: DANGER, WARNING, CAUTION, NOTICE
Type and source of danger/damage
Consequences of danger
Taking countermeasures to avoid the danger or damage
Symbol Meaning
Tips and recommendations on the use of the device
General danger
Danger due to explosive atmosphere
DANGER
Danger to persons
Non-compliance with the instruction results in severe or fatal injuries to
persons.
WARNING
Danger to persons
Non-compliance with the instruction can result in severe or fatal injuries
to persons.
CAUTION
Danger to persons
Non-compliance with the instruction can result in light injuries to
persons.
NOTICE
Avoiding material damage
Non-compliance with the instruction can result in material damage to the device
and / or its environment.
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Safety Notes
5
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
2.3 Symbols on the Device
3 Safety Notes
3.1 Operating Instructions Storage
Read the operating instructions carefully.
Store the operating instructions at the mounting location of the device.
Observe applicable documents and operating instructions of the devices to be
connected.
3.2 Personnel Qualification
All activities on the device may only be performed by a qualified specialist.
This primarily applies to work in the following areas:
Project engineering
Mounting/dismounting the device
(Electrical) Installation
• Commissioning
Maintenance, repair, cleaning
The specialist who performs these activities must be familiar with the relevant national
standards and regulations for electrical engineering.
Additional knowledge is required for activities in hazardous areas!
R. STAHL recommends having a level of knowledge equal to that described in the
following standards:
UL 60079-17 (Inspection and maintenance of electrical installations)
National Electrical Code (NEC NFPA 70 Article 504 or ISA-RP 12.6)
Canadian Electrical Code, Part I, Safety Standard for Electrical Installations
(CSA C22.1)
Local regulations and laws
Symbol Meaning
FM test mark, proven conformity of the product with the safety regulations of
the USA and Canada
05594E00
CE marking in accordance with the current applicable directive.
02198E00
Device certified for hazardous areas in accordance with the marking.
Safety Notes
6287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
3.3 Safe Use
Before mounting
Read and observe the safety notes in these operating instructions!
Ensure that the contents of these operating instructions are fully understood by the
personnel in charge.
Use the device in accordance with its intended and approved purpose only.
Always consult with R. STAHL Schaltgeräte GmbH if using the device under operating
conditions which are not covered by the technical data.
Make sure that the device is not damaged.
We cannot be held liable for damage at the device caused by incorrect or unauthorised
use or non-compliance with these operating instructions.
For mounting and installation
Have mounting and installation performed only by qualified and authorised persons
(see chapter "Qualification of the personnel").
The device is only to be installed in areas for which it is suited based on its marking.
During installation and operation, observe the information (characteristic values and
rated operating conditions) on the rating, data and information plates located on the
device, as well as the technical data in these operating instructions.
Before installation, make sure that the device is not damaged.
Do not open the device when it is energized.
Prevent electrostatic discharge at the device.
Commissioning, maintenance, repair
Only have commissioning and repairs performed by qualified and authorised persons
(see chapter "Personnel qualification").
Before commissioning, make sure that the device is not damaged.
Perform only maintenance work described in these operating instructions.
The nature of these instructions is only informative and does not cover all of
the details, variations or combinations in which this equipment may be used,
its storage, delivery, installation, safe operation and maintenance.
Since conditions of use of the product are outside of the care, custody and
control of the manufacturer, the purchaser should determine the suitability of
the product for his intended use, and assumes all risk and liability whatsoever
in connection therewith.
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Function and Device Design
7
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
3.4 Specific Conditions of Use
Lock the hinged cover using the bayonet ring if the plug is not inserted.
The 8570/21 shall not be applied in an explosive dust atmosphere where high
electrostatic charging processes are present that could result in propagating brush
discharges. See IEC TS60079-32-1 for additional guidance.
Receptacle is suitable for connection to a 8570/22 plug of the same configuration and
electrical ratings.
The flameproof joints cannot be repaired.
3.5 Modifications and Alterations
4 Function and Device Design
4.1 Function
Application range
The receptacle 8570/21 is an explosion-protected electrical device. It is approved for
use in hazardous areas which are classified acc. to. NEC 505 for Division or Zone.
Details please see certification and the "Technical data" chapter. It connects portable and
stationary electrical equipment as well as electric lines and electrical circuits in hazardous
areas.
DANGER
Explosion hazard due to modifications and alterations to the device!
Non-compliance results in severe or fatal injuries.
Do not modify or alter the device.
No liability or warranty for damage resulting from modifications and
alterations.
DANGER
Explosion hazard due to improper use!
Non-compliance results in severe or fatal injuries.
Use the device only in accordance with the operating conditions
described in these operating instructions.
Use the device only for the intended purpose specified in these
operating instructions.
Technical Data
8287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
5 Technical Data
Please refer to the technical data on the device.
Explosion Protection
Global (IECEx)
Gas and dust IECEx PTB 05.0023
Ex db eb IIC T6 ... T5 Gb
Ex tb IIIC T73 °C Db
Europa (ATEX)
Gas and dust PTB 03 ATEX 1227
E II 2 G Ex db eb IIC T6 ... T5 Gb
E II 2 D Ex tb IIIC T73 °C Db
USA (NEC)
Gas and dust
FM20US0116X
Cl. I, Zone 1, AEx db eb IIC T6 ... T5 Gb
Cl. I, Div. 2, Groups A, B, C, D
Zone 21, AEx tb IIIC T80 °C Db
Cl. II, III, Div. 1, Groups E, F, G
Canada (CE Code)
Gas and dust FM20CA0056X
Ex db eb IIC T6 ... T5 Gb (C)
Cl. I, Div. 2, Groups A, B, C, D
Ex tb IIIC T80 °C Db (C)
Cl. II, III, Div. 1, Groups E, F, G
Cl. I, Zone 1, AEx db eb IIC T6 Gb
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Technical Data
9
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Technical Data
Electrical data
Rated operational
voltage
Main contacts 8570/21-3..: max. 480 V AC / max. 110 V DC
8570/21-4..: max. 600 V AC / max. 110 V DC
8570/21-5..: max. 600 V AC / max. 110 V DC
Auxiliary contacts max. 500 V AC / max. 110 V DC
Frequency 50/60 Hz (for frequencies ) 100 Hz reduction to 12 A required)
Voltage tolerance -10 to +10 %
Rated operational
current
Main contacts 20 A
Auxiliary contacts max. 6 A
Utilization category AC-3: 500 V/20 A
DC-1: 110 V/16 A
UL508: 600 V/20 A
Rated insulation
voltage
Main contacts 8570/21-3..: 550 V
8570/21-4..: 750 V
8570/21-5..: 750 V
Auxiliary contacts 550 V
Back-up fuse
without thermal
protection
20 A gG
with thermal
protection
35 A gG
Alternatively, a Class J fuse of suitable size can be used.
Technical Data
10 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Ambient conditions
Operating
temperature range
-50 to +65 °C
-40 to +65 °C, optional (silicone-free)
(The storage temperature corresponds to the ambient temperature)
At frequencies < 100 Hz
Technical Data
2 pole / 3 wire (1P + N + PE / 2P + PE) - without auxiliary contacts
Temperature
class
T6 T5
Ambient
temperature
Ta (
+45
°C /
+113
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
1.5
mm2 /
AWG 16
1.5
mm 2 /
AWG 16
16 A 13 A 13 A 10 A 10 A 16 A 10 A
1.5
mm
2 /
AWG 16
2.5
mm 2 /
AWG 14
16 A 13 A 13 A 10 A 10 A 16 A 10 A
2.5
mm
2 /
AWG 14
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 13 A 10 A 16 A 10 A
2.5
mm
2 /
AWG 14
4
mm 2 /
AWG 12
16 A 16 A 16 A 13 A 10 A 16 A 10 A
4
mm
2 /
AWG 12
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 10 A 16 A 10 A
4
mm
2 /
AWG 12
4
mm 2 /
AWG 12
20 A 20 A 16 A 16 A 10 A 20 A 10 A
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Technical Data
11
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Technical Data
3 pole / 4 wire (3P + PE) - with auxiliary contacts
Temperature
class
T6 T5
Ambient
temperature
Ta (
+35
°C /
+95
°F
Ta (
+40
°C /
+104
°F
Ta (
+45
°C /
+113
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
1.5
mm2 /
AWG 16
1.5
mm 2 /
AWG 16
16 A 13 A 13 A 6 A 16 A 13 A 10 A 6 A
1.5
mm
2 /
AWG 16
2.5
mm 2 /
AWG 14
16 A 13 A 13 A 10 A 16 A 13 A 10 A 6 A
2.5
mm
2 /
AWG 14
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 10 A 16 A 16 A 13 A 6 A
2.5
mm
2 /
AWG 14
4
mm 2 /
AWG 12
16 A 16 A 16 A 16 A 13 A 13 A 16 A 16 A 13 A 6 A
4
mm
2 /
AWG 12
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 13 A 6 A 16 A 16 A 10 A 6 A
4
mm
2 /
AWG 12
4
mm 2 /
AWG 12
20 A 20 A 16 A 20 A 16 A 13 A
Technical Data
12 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Technical Data
3 pole / 4 wire (3P + PE) - without auxiliary contacts
Temperature
class
T6 T5
Ambient
temperature
Ta (
+35
°C /
+95
°F
Ta (
+40
°C /
+104
°F
Ta (
+45
°C /
+113
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
1.5
mm2 /
AWG 16
1.5
mm 2 /
AWG 16
16 A 13 A 13 A 13 A 10 A 10 A 6 A 16 A 13 A 10 A 6 A
1.5
mm
2 /
AWG 16
2.5
mm 2 /
AWG 14
16 A 13 A 13 A 13 A 10 A 10 A 6 A 16 A 13 A 10 A 6 A
2.5
mm
2 /
AWG 14
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 13 A 13 A 6 A 16 A 16 A 13 A 6 A
2.5
mm
2 /
AWG 14
4
mm 2 /
AWG 12
16 A 16 A 16 A 16 A 13 A 13 A 6 A 16 A 16 A 13 A 6 A
4
mm
2 /
AWG 12
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 16 A 10 A 6 A 16 A 16 A 10 A 6 A
4
mm
2 /
AWG 12
4
mm 2 /
AWG 12
20 A 20 A 16 A 16 A 16 A 13 A 20 A 16 A 13 A
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Technical Data
13
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Technical Data
4 pole / 5 wire (3P + N + PE) - with auxiliary contacts
Temperature
class
T6 T5
Ambient
temperature
Ta (
+35
°C /
+95
°F
Ta (
+40
°C /
+104
°F
Ta (
+45
°C /
+113
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
1.5
mm2 /
AWG 16
1.5
mm 2 /
AWG 16
16 A 16 A 13 A 13 A 10 A 6 A 16 A 13 A 10 A
1.5
mm
2 /
AWG 16
2.5
mm 2 /
AWG 14
16 A 16 A 13 A 13 A 10 A 10 A 16 A 13 A 10 A 6 A
2.5
mm
2 /
AWG 14
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 13 A 13 A 16 A 16 A 13 A 6 A
2.5
mm
2 /
AWG 14
4
mm 2 /
AWG 12
16 A 16 A 16 A 16 A 13 A 13 A 16 A 16 A 13 A 6 A
4
mm
2 /
AWG 12
2.5
mm 2 /
AWG 14
16 A 16 A 13 A 13 A 10 A 10 A 16 A 10 A 10 A 6 A
4
mm
2 /
AWG 12
4
mm 2 /
AWG 12
20 A 16 A 16 A 16 A 13 A 10 A 20 A 16 A 13 A
Technical Data
14 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
The maximum rated operational current depends on the conductor
cross-section and the ambient temperature.
At frequencies ) 100 Hz reduction to 12 A required.
Technical Data
4 pole / 5 wire (3P + N + PE) - without auxiliary contacts
Temperature
class
T6 T5
Ambient
temperature
Ta (
+35
°C /
+95
°F
Ta (
+40
°C /
+104
°F
Ta (
+45
°C /
+113
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Ta (
+50
°C /
+122
°F
Ta (
+55
°C /
+131
°F
Ta (
+60
°C /
+140
°F
Ta (
+65
°C /
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
1.5
mm2 /
AWG 16
1.5
mm 2 /
AWG 16
16 A 16 A 13 A 13 A 10 A 10 A 6 A 16 A 13 A 10 A 6 A
1.5
mm
2 /
AWG 16
2.5
mm 2 /
AWG 14
16 A 16 A 13 A 13 A 10 A 10 A 6 A 16 A 13 A 10 A 6 A
2.5
mm
2 /
AWG 14
2.5
mm 2 /
AWG 14
16 A 16 A 16 A 16 A 13 A 13 A 6 A 16 A 16 A 13 A 6 A
2.5
mm
2 /
AWG 14
4
mm 2 /
AWG 12
16 A 16 A 16 A 16 A 13 A 13 A 6 A 16 A 16 A 13 A 6 A
4
mm
2 /
AWG 12
2.5
mm 2 /
AWG 14
16 A 16 A 13 A 13 A 10 A 10 A 6 A 16 A 10 A 10 A 6 A
4
mm
2 /
AWG 12
4
mm 2 /
AWG 12
20 A 16 A 16 A 16 A 13 A 13 A 20 A 16 A 13 A
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Technical Data
15
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Mechanical data
Number of poles 2 pole / 3 wire (1P + N + PE) (N-conductor switched)
2 pole / 3 wire (2P + PE)
3 pole / 4 wire (3P + PE)
4 pole / 5 wire (3P + N + PE) (N-conductor switched)
Auxiliary contacts Optional max. 2 auxiliary contacts (ON – delayed, OFF – leading)
Auxiliary contacts in Ex i version are fitted with gold-plated contacts.
Optionally in NAMUR resistor circuitry.
Switching handle lockable in 0 or I position
max. bracket
diameter
5 mm / 0.19 inch
Material
Enclosure polyamide, glass fibre reinforced
Degree of protection IP66 acc. to IEC 60529,
IP64 acc. to UL 60079,
NEMA 3, 4, 4X acc. to ANSI/NEMA 250
Impact strength IK10 as per IEC/EN 62262-0 and IEC 60309-1,
7 Joule as per UL 60079
Connection type Screw-type terminals
Connection
Terminals
Main contacts
Auxiliary contacts
Weight
Service life > 5,000 switching cycles (electrical and mechanical) acc. to UL 60309-1
Tightening torque Terminals: 1.2 Nm / 10.62 lbf inch
Connection chamber cover of the receptacle: 1.8 Nm / 15.93 lbf inch
Technical Data
solid 1 x 1.5 mm2 to 2 x 6 mm2
(1 x AWG 16 to 2 x AWG 10)
finely stranded 1 x 1.5 mm2 to 2 x 4 mm2
(1 x AWG 16 to 2 x AWG 12)
finely stranded with core end
sleeve
1 x 1.5 mm2 to 2 x 4 mm2
(1 x AWG 16 to 2 x AWG 12)
solid/finely stranded 1 x 0.5 mm2 to 2 x 2.5 mm2
(1 x AWG 20 to 2 x AWG 14)
8570/21-3 1.12 kg / 2.47 lbs
8570/21-4 1.35 kg / 2.98 lbs
8570/21-5 1.45 kg / 3.19 lbs
Technical Data
16 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Cable glands
Adaptor Internal thread 1 x NPT 3/4"
Nickel-plated brass
Stopping plug 1 x M25 x 1.5
Nickel-plated brass
(positioning on the top or at the side, according to the order)
optional: top max. 2 x NPT 3/4"; sealing plugs or metal entries are also
available
External earth
connection
Positioning at side acc. to order possible
(connection cross-section 10 mm2 / AWG 7)
Technical Data
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Technical Data
17
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Arrangement of the earth contact sleeve
Position: clock hour position, view: front side of the socket
Arrangement of socket contacts and terminal markings
Arrangement of the socket contacts and terminal markings in the 6h position
(view from the front side of the socket to the socket contacts)
02395E00
Example: Clock hour position
19178E00
200 to 250 V = 6 h
2 pole / 3 wire
(1P + N + PE)
19590E00
2 pole / 3 wire
(2P + PE)
19178E00
3 pole / 4 wire
(3P + PE)
19265E00
4 pole / 5 wire
(3P + N + PE)
19266E00
8570/21-3.. 8570/21-3.. 8570/21-4.. 8570/21-5..
Technical Data
18 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
Colour code and arrangement of socket contacts and terminal markings;
HP rating assignment
Colour code according to UL 60309-1 and arrangement relative to the polarizing slot for
different voltages and frequencies in accordance with UL 60309-2
1) Mainly for ship installations
2) Only for refrigerated containers (standardized by ISO)
For further technical data, see r-stahl.com.
No. of poles Frequency
[Hz]
Voltage
[V]
Colour
code
Position of
earth contact
sleeve
Current
[A]
Power
[HP]
2 pole /
3 wire
(1P + N + PE)
(2P + PE)
50 and 60 > 50 to 110 V DC grey 3 h 10 to 16 1.5
50 and 60 100 to 130 yellow 4 h 10 to 20 1.5
50 and 60 200 to 250 blue 6 h 10 to 20 3
50 and 60 380 to 415 red 9 h 10 to 20 5
50 and 60 480 red 7 h 10 to 20 5
50 and 60 500 black 7 h 10 to 20 5
60 277 grey 5 h 10 to 20 3
100 to 300 > 50 green 10 h 10 to 12 0.5 to 5
> 300 to 500 > 50 green 2 h 10 to 12 0.5 to 5
3 pole /
4 wire
(3P + PE)
50 and 60 100 to 130 yellow 4 h 6 to 20 3
50 and 60 200 to 250 blue 9 h 6 to 20 5
50 and 60 380 to 415 red 6 h 6 to 20 10
50 and 60 480 red 7 h 6 to 20 10
50 and 60 500 black 7 h 6 to 20 10
50 and 60 600 to 690 black 5 h 6 to 20 15
50 380 2) red 3 h 6 to 20 10
60 440 2) red 3 h 6 to 20 10
60 440 to 460 1) red 11 h 6 to 20 10
100 to 300 > 50 green 10 h 6 to 12 1.5 to 10
> 300 to 500 > 50 green 2 h 6 to 12 1.5 to 10
4 pole /
5 wire
(3P + N + PE)
50 and 60 57/100 to 75/130 yellow 4 h 6 to 20 3
50 and 60 120/208 to 144/250 blue 9 h 6 to 20 5
50 and 60 200/346 to 240/415 red 6 h 6 to 20 10
50 and 60 277/480 red 7 h 6 to 20 10
50 and 60 288/500 black 7 h 6 to 20 10
50 and 60 347/600 to 400/690 black 5 h 6 to 20 15
50 220/380 2) red 3 h 6 to 20 3
60 250/440 2) red 3 h 6 to 20 3
60 250/440 to 265/460 1) red 11 h 6 to 20 10
100 to 300 > 50 green 10 h 6 to 12 1.5 to 10
> 300 ... 500 > 50 green 2 h 6 to 12 1.5 to 10
287620 / 8570674300
2022‐03‐28·IO00·III·en·00
Transport and Storage
19
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
6 Transport and Storage
Transport and store the device only in the original packaging.
Store the device in a dry place (no condensation) and vibration-free.
Do not drop the device.
7 Mounting and Installation
7.1 Dimensions / Fastening Dimensions
Dimensional drawings (all dimensions in mm [inches]) – Subject to modification
10338E00
10333E00
8570/21-3.. 8570/21-4.. and 8570/21-5..
93 [3,66]
105 [4,13]
92,50 [3,64]
7,70 [0,30]
Ø Ø
6,20 [ 0,24]
115 [4,53]
~ 169 [~ 6,65]
~ 231 [~ 9,11]
~ 167 [~ 6,59]
38
[1,50]
12 [0,47]
23 [0,91]
~ 180 [~ 7,08]
~ 247 [~ 9,73]
~ 179 [~ 7,04]
46
[1,81]
12 [0,47]
23 [0,91]
Mounting and Installation
20 287620 / 8570674300
2022‐03‐28·IO00·III·en·00
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
SolConeX Receptacle, 20 A
Series 8570/21
7.2 Mounting / Dismounting, Operating Position
7.2.1 Mounting
This device is suitable for outdoor and indoor use.
Provide a protective roof or wall if the enclosure and explosion-protected electrical
equipment are used outdoors.
Operating position
19605E00
Hinged cover preferably facing
downwards, connection chamber facing
upwards.
21821E00
Mounting: Fasten the receptacle using
four screws and suitable washers on an
even wall.
The fastening holes are designed as elongated holes.
This allows vertical and horizontal adjustment during mounting.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Stahl 8570 Mode d'emploi

Taper
Mode d'emploi