Modern Forms FM-60211 Catalonia Mode d'emploi

Catégorie
Mur
Taper
Mode d'emploi
1
INSTALLATION INSTRUCTIONS

FM-60211/FM-60217
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Sep. 2021
CAUTION: To prevent electrical shock, ensure electricity has been turned o at the circuit breaker before beginning.
• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de lélectricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chion humide.
Wire Connector
Qty: 3pcs+1 Extra
Mounting Screw
Qty:1 Extra Plastic Anchor
Qty: 3pcs+1 Extra
Wood Screw
Qty: 3pcs+1 Extra
C
ABD
Fixed Screw
Qty: 6pcs+1 Extra
E
2
INSTALLATION INSTRUCTIONS

FM-60211/FM-60217
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Sep. 2021
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) and back plate from the xture.
4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchor (E).
5. Secure the mounting back plate to the junction box using standard junction box screws that comes with the junction box,fasten it to the
ceiling using wood screw (D).
 (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting plate marked “GND” must face out.
6. Properly secure the safety cord to the bracket on mounting back plate to temporary hang the xture in place.
CONNECTING THE WIRES (Fig. 2)
7. Connect the driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet
box has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly to
the back plate using the screw provided. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION
8. Fasten the two brackets to the xture using screw ( C ), position the alabaster so it sits in the notch of the bracket, nally secure it with the
third bracket . (Fig. 3)
9. Secure the xture by mounting the canopy onto the back plate. Turn and rotate the canopy in the direction of the arrow until it stops (Fig1).
10. Fasten the canopy to the mounting back plate with mounting screws(B).
DIMMING WIRING INFORMATION (Fig. 4)
11. This xture features electronic low voltage (ELV or TRIAC) or 0-10V dimming capabilities. See notes below for specic dimming wires
information.
12. To utilize ELV or TRIAC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground).
13. To utilize 0-10V dimming: use wire purple (dim+), pink or gray (dim-), black (hot), white (neutral) and bare copper ground wire (ground).
: Make sure to connect 0-10V prior to power-up the xture in order to allow the 0-10V dimming to function properly.
FIG. 1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)

Junction Box
Plastic Anchor
E
Mounting Back Plate
Wire Connector
Junction Box Screw
Wood Screw
Mounting screw
Bracket
Alabaster
(FM-60211 RPL-GLA-60211
FM-60217 RPL-GLA-60217)
Fixture
Fixed screw
Safety Cords
(Only FM-60217)
Driver(Canopy Inside)
4"L*4"W*5/8"H
A
D
C
B
(Only FM-60217)
(Only FM-60217)
Alabaster
(FM-60211 RPL-GLA-60211
FM-60217 RPL-GLA-60217)
FIG. 3
White - Neutral
Black - Hot
Purple - Dim+
Pink or Gray - Dim-
Red - Fixture+
Black - Fixture-

Ø5
"
FM-60211 Back Plate
Ø
8
1/8
"
1
3/8
"
1
3/4
"
Ø
6
1/4
"
1
3/8
"
1
3/4
"
FM-60217 Back Plate
  • Page 1 1
  • Page 2 2

Modern Forms FM-60211 Catalonia Mode d'emploi

Catégorie
Mur
Taper
Mode d'emploi