Bradford White DH1-65T6BN Guide d'installation

Taper
Guide d'installation
238-48114-00B REV 11/14
INSTALLATION INSTRUCTIONS FOR
SOLID VENT KIT PART NUMBER
239-47810-00
239-51283-00
This vent kit is designed to bring all air for combustion from the outside and
vent all the combustion products to the outside when properly installed. This
vent kit should only be used with direct vent water heaters that were
designed to use this vent kit. Refer to the label on the water heater to
determine if this kit is the correct kit for the water heater that you are
installing. Consult the supplier of the water heater if you are not certain that
this is the correct vent kit. Refer to the information in these instructions and
the instructions provided with the water heater when determining the location
of the vent terminal and water heater.
The vent system must terminate so that proper clearances are maintained as
cited in local codes or the latest edition of the National Fuel Gas Code, ANSI
Z223.1 as follows:
1. Do not terminate near soffit vents or crawl space or other area where
condensate or vapor could create a nuisance or hazard or cause
property damage.
2. Do not terminate the exhaust vent terminal where condensate or vapor
could cause damage or could be detrimental to the operation of
regulators, relief valves, or other equipment.
3. Do not terminate the exhaust vent terminal over public area or
walkways where condensate or vapor can cause nuisance or hazard.
4. The vent shall terminate a minimum of 12 inches above expected
snowfall level to prevent blockage of vent termination.
Vent pipes serving direct vent appliances are classified by building codes as
“vent connectors”. Required clearances from combustible materials must be
provided in accordance with information in this manual under LOCATION OF
WATER HEATER and CLEARANCES, and with National Fuel Gas Code
and local code.
WARNING
The vent-air intake system must be properly installed. Failure to
properly install the vent-air intake system could result in property
damage, personal injury or death.
DO NOT install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.
2
Figure 1
Direct Vent Terminal Clearances
Canadian Installations
1
US Installations
2
A= Clearance above grade, veranda, porch, deck or balcony 12 inches (30 m) 12 inches (30 cm)
B= Clearance to widow or door that may be opened 12 inches (30 m) 9 inches (23 cm)
C= Clearance to permanently closed widow *b *b
D=
Vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 2 feet (61 cm) from
the center line of the terminal
12 inches (30 cm) *a
12 inches (30 cm)
*a
E= Clearance to unventilated soffit 12 inches (30 cm) *a 12 inches (30 cm) *a
F= Clearance to outside corner *b *b
G= Clearance to inside corner *b *b
H=
Clearance to each side of center line extended above
meter/regulator assembly
3 feet (91 cm) within a
height 15 feet (4.6 m)
above the meter/regulator
assembly
*b
I= Clearance to service regulator vent outlet or oil tank vent 36 inches (91 cm) *b
J=
Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other appliance
12 inches (30 cm) 9 inches (23 cm)
K= Clearance to a mechanical air supply inlet 6 feet (1.83 m)
3 feet (91 cm) above
if within 10 feet
horizontally
L=
Clearance above paved sidewalk or paved driveway
located on public property
7 feet (2.13 m)† *b
M= Clearance under a veranda, porch, deck, or balcony 12 inches (30 cm) ‡ *b
1
In accordance with the current CAN/CGA-B149 Installation Codes.
2
In accordance with the current ANSI Z223.1-(Latest edition)/NFPA 54 National Fuel Gas Code.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two
single-family dwellings and serves both dwellings.
‡ Permitted only if a veranda, porch, deck or balcony is fully open on a minimum of two sides beneath
the floor.
*a) A minimum clearance value determined by testing in accordance with section 2.20.
*b) “Clearance in accordance with local installation codes and the requirements of the gas supplier”.
3
IMPORTANT – Refer to parts list in the back of this manual
and become familiar with the parts named in kit.
The co-axial vent-air intake tubes of this water heater can be installed in any
360 configuration as long as the proper clearances for installation,
plumbing, operation and servicing are maintained. (See Figure 2).
Figure 2
Note: Maintain proper clearances for installation, plumbing, operation
and service.
SOLID VENT KIT INSTALLATION
WARNING
The vent-air intake system must be properly installed. Failure to
properly install the vent-air intake system could result in property
damage, personal injury or death.
DO NOT install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.
WARNING
The vent-air intake terminal must be installed through an outside wall in a
horizontal position. This direct vent water heater is not designed for through the
roof vertical venting.
4
HORIZONTAL AND VERTICAL VENT-AIR INTAKE LENGTHS
This Direct Vent Gas Water Heater may come with one (1) solid vent-air
intake “Kit C”. Optional vent-air intake kits are available that can extend the
horizontal length and/or vertical height of the vent-air intake system. Table A
lists the various vertical and horizontal vent-air intake system configurations.
The water heater may be shipped with a solid vent and air intake kit. The
components of this vent and air intake systems may be as follows:
3” Vent Tube* Vent Terminal Hardware
5” Air Intake Tube* RTV Silicone Sealant
Vent Terminal 3” Vent Elbow
Inner Wall Term. Mounting Flange 5” Vent Elbow
Outer Wall Term. Mounting Flange
*The vent and air intake telescopes from 13 3/4" to 23 11/16”.
Table A
Horizontal "X"
13 1/4
14 3/16
15
17 11/16
22 1/4
32 3/16
36
55 7/8
58 5/16
104 5/16
Vertical "Y"
10
order
kit A
order
kit B
no add'l
kit req'd
order
kit C
order
kit D
14 3/4
15 11/16
*order
kit A (2)
order
kit A & B
order
kit A
order
kit A & C
order
kit A & D
16 1/2
19 3/16
order
kit A & B
*order
kit B (2)
order
kit B
order
kit B & C
order
kit B & D
23 3/4
33 11/16
order
kit A
order
kit B
order
kit C
*order
kit C (2)
order
kit D
37 1/2
57 3/8
order
kit A & C
order
kit C & B
*order
kit C (2)
*order
kit C (3)
order
kit C & D
59 13/16
105 13/16
order
kit D & A
order
kit D & B
order
kit D
order
kit D & C
*order
kit D (2)
* (2) = Order two of the kits referenced.
* (3) = Order three of the kits referenced.
The bold text above show what kit(s) are needed in addition to the standard
vent and air intake tubes. If the standard vent and air intake tubes are not
used in the venting system (those that do not have bold text) they can be
discarded or saved.
5
Figure 3
6
VENT-AIR INTAKE SYSTEM INSTALLATION
Tools Required For Vent-Air Intake Installation
The following minimum tools are required to properly install the vent-
air intake system. Note: Wall construction will determine tool usage.
Tape Measure
Drill
3/16 inch (4.5 mm) Diameter Drill Bit(s)
1/8 inch (3.0 mm) Diameter Drill Bit(s)
Masonry Drill Bit(s) (For Poured Concrete, Concrete Block and Brick
Wall Construction)
Reciprocating Saw w/appropriate Blade(s) (Dependent on Wall
Construction)
Chisel (For Poured Concrete, Concrete Block and Brick Wall
Construction)
Hammer (For Poured Concrete, Concrete Block and Brick Wall
Construction)
1/4 & 5/16 inch Nut Drivers (Preferred) or Slotted Head Screwdriver
Phillips Head Screwdriver
WARNING
The vent-air intake system must be properly installed. Failure to
properly install the vent-air intake system could result in property
damage, personal injury or death.
Do not install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.
IMPORTANT
When the following instructions specify, to seal a vent-air intake
joint, use only Loctite Ultra Blue 587 RTV Silicone sealant. A
tube of Loctite Ultra Blue 587 RTV Silicone sealant is supplied
with every direct vent water heater and each optional vent-air
intake kit. Make sure that all joints are completely sealed.
When drilling pilot holes for the #8 sheet metal screws through
the five (5) inch (12.7 cm) diameter components, be careful not
to drill into the inner three (3) inch (7.6 cm) diameter
components.
7
1. Measure the vertical height “Y” required in your installation (See Figure
3). Reference the appropriate Table A to determine number of vent-air
intake kits required in your installation.
2. Measure the horizontal length “X” required in your installation (See
Figure 3). Reference Table A to determine number of vent-air intake kits
required in your installation.
3. Cut a 5-1/2 inch (14 cm) diameter minimum clearance hole in the wall at
the point where the vent-air intake tubes will pass through the outside
wall and connect with the direct vent-air intake terminal (See Figure 4).
4. From outside the building, position the outer wall mount plate and direct
vent-air intake terminal over the center of the opening. Mark the
mounting screw hole locations. With a 3/16 inch (4.5 mm) diameter drill
bit (not supplied), drill holes for the wall anchors (supplied). Install the
wall anchors but DO NOT affix the outer wall mount plate and direct
vent-air intake terminal to the wall at this time (See Figure 4). Note:
Certain construction of walls may require the use of a different type of
wall anchoring means than supplied. DO NOT modify the direct vent-air
intake terminal or outer wall mount plate.
Figure 4
8
5. Insert the straight end of the three (3) inch (7.6 cm) diameter
elbow into the flue reducer until firmly seated and oriented in the
correct direction. With a 1/8 inch (3.0 mm) diameter drill bit (not
supplied), drill three (3) holes, 120
o
apart, through the flue
reducer into the three (3) inch (7.6 cm) diameter elbow. Fasten
with three (3) #8 sheet metal screws (supplied). Using the
supplied special RTV silicone sealant, apply a sufficient amount
to seal the joint (See Figure 5).
Figure 5
6. Place the straight end of the five (5) inch (12.7 cm) diameter
elbow over the three (3) inch (7.6 cm) diameter elbow and
plenum collar until seated on top of the plenum box. Make
certain that the five (5) inch (12.7 cm) diameter elbow is oriented
in the same direction as the three (3) inch (7.6 cm) diameter
elbow and both are oriented in the correct direction. Drill three
(3) 1/8 inch (3.0 mm) diameter holes, 120
o
apart, through the five
(5) inch (12.7 cm) diameter elbow into the plenum collar. Fasten
with three (3) #8 sheet metal screws (supplied) (See Figure 6).
9
Figure 6
7. Extend the three (3) inch (7.6 cm) diameter telescopic tube to its
maximum length and slide the backing plate over it. Place the
large end of the three (3) inch (7.6 cm) diameter telescopic tube
through the hole in the outside wall. Insert the smaller end of the
three (3) inch diameter (7.6 cm) telescopic tube into the flared
end of the three (3) inch (7.6 cm) diameter elbow, one (1) inch
(2.5 cm) (or until seated). Drill three (3) 1/8 inch diameter holes,
120
o
apart, through the three (3) inch (7.6 cm) diameter elbow
into the three (3) inch (7.6 cm) diameter telescopic tube. Fasten
with three (3) #8 sheet metal screws (supplied). Adjust the
overall length of the three (3) inch (7.6 cm) diameter telescopic
tube so that 2-1/2 inches (6.4 cm) extends beyond the outside
wall. Drill three (3) 1/8 inch (3.0 mm) diameter holes, 120
o
apart,
through the three (3) inch (7.6 cm) diameter telescopic tubes
where the small and large sections overlap. Fasten with three (3)
#8 sheet metal screws (supplied). Using the supplied special
RTV silicone sealant, apply a sufficient amount to seal the joints
(See Figure 7).
10
Figure 7
8. Extend the five (5) inch (12.7 cm) diameter telescopic tube to its
maximum length. Place the large end of the five (5) inch (12.7
cm) diameter telescopic tube over the collar on the outer wall
mount plate. Drill three (3) 1/8 inch (3.0 mm) diameter holes,
120
o
apart, through the five (5) inch (12.7 cm) diameter telescopic
tube into the collar on the outer wall mount plate. Fasten with
three
(3) #8 sheet metal screws (supplied). Using the supplied
special RTV silicone sealant, apply a sufficient amount to seal the
joint (See Figure 8).
Figure 8
11
9. From outside the building, slide the five (5) inch (12.7 cm)
diameter telescopic tube through the opening in the wall until the
outer wall mount plate is flush with the wall (See Figure 9).
Figure 9
10. Using the supplied special RTV silicone sealant, apply a bead
one (1) inch (2.5 cm) from the end of the three (3) inch (7.6 cm)
diameter tube that is part of the vent-air intake terminal. Slide the
direct vent-air intake terminal into the three (3) inch (7.6 cm)
diameter telescopic tube that extends through the wall and
position it so it is flush with the outer wall mount plate. Make sure
that the rain guard and the word “HOT” on the end of the direct
vent-air intake terminal are oriented properly. Secure the direct
vent-air intake terminal to the outer wall mount plate and wall with
four (4) #10 x 1 inch screws (supplied) (See Figure 10). Note:
Certain construction of walls may require the use of different type
of anchoring means than supplied. DO NOT modify the direct
vent-air intake terminal or outer wall mount plate.
12
Figure 10
11. From inside the building, slide the backing plate over the five (5)
inch (12.7 cm) diameter telescopic tube until it is flush with the
wall. Adjust the length of the five (5) inch (12.7 cm) diameter
telescopic tube and insert the end into the flared end of the five
(5) inch (12.7 cm) diameter elbow one (1) inch (2.5 cm) (or until
seated). Drill three (3) 1/8 inch (3.0 mm) diameter holes, 120
o
apart, through the five (5) inch (12.7 cm) diameter elbow into the
five (5) inch (12.7 cm) diameter telescopic tube and through the
tubes where the small and large sections overlap. Fasten with
three (3) #8 sheet metal screws (supplied). Using the supplied
special RTV silicone sealant, apply a sufficient amount to seal all
joints (See Figure 11).
Figure 11
13
12. Mark the mounting screw hole locations for the backing plate.
Rotate the backing plate in order to gain access to the markings.
With a 3/16 inch diameter drill bit (not supplied), drill holes for the
supplied wall anchors. Install the wall anchors and secure the
backing plate to the wall with four (4) #10 x 1 inch screws
(supplied) (See Figure 12). Note: Certain construction of walls
may require the use of a different type of anchoring means than
supplied.
Figure 12
IMPORTANT
When the installation is complete, visually inspect the air intake
system to insure that all joints are completely sealed.
14
DIRECT VENT WATER HEATER VENTING PARTS LISTS
PART NAME & DESCRIPTION
1. Direct Vent-Air Intake Terminal 6. Inner Telescopic Vent Tube
2. Outer Wall Mounting Plate 7. Inner Elbow
3. Inner Wall Backing Plate 8. Vent Terminal Guard (Optional
not included)
4. Outer Telescopic Air Intake Tube 9. Special RTV silicone sealant
5. Outer Elbow
15
VENT-AIR INTAKE KITS
16
NOTES:
16
NOTES:
15
VENT-AIR INTAKE KITS
14
LISTES DES PIÈCES DIRECTES DE MISE À L'AIR LIBRE
DE CHAUFFE-EAU DE PASSAGE
NOM ET DESCRIPTION DE PARTIE
1.
Borne directe de prise de
Passage-Air
6.
Tube télescopique intérieur de
passage
2. Plat de support externe de mur 7. Coude intérieur
3. Plat intérieur de support de mur 8.
Garde terminale de passage
(non inclus facultatifs)
4.
Tube externe d'entrée d'air de
télescope
9.
Mastic spécial de silicone de
RTV
5. Coude externe
13
12. De l'intérieur du bâtiment, glissez le plat de support au-dessus (5) du
tube télescopique de diamètre de pouce cinq (12.7 cm) jusqu'à ce
qu'il soit affleurant du mur. Ajustez la longueur (5) du tube
télescopique de diamètre de pouce cinq (12.7 cm) et insérez
l'extrémité dans la fin évasée de cinq (5) pouces du coude un de
diamètre de pouce (12.7 cm) (1) (2.5 cm) (ou jusqu'à assis). Forez
trois (3) trous de diamètre de 1/8 pouce (3.0 mm), 120o à part, par
(5) le coude de diamètre de pouce cinq (12.7 cm) dans (5) le tube
télescopique de diamètre de pouce cinq (12.7 cm) et par les tubes
où les petites et grandes sections recouvrent. Attachez avec trois
(3) vis en métal de feuille #8 (fournies). En utilisant le mastic spécial
fourni de silicone de RTV, appliquez une quantité suffisante pour
sceller tous les joints (voir Le schéma 12).
Le schéma 12
IMPORTANT
Quand l'installation est complète, inspectez visuellement le
système d'entrée d'air pour assurer que tous les joints sont
complètement scellés.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Bradford White DH1-65T6BN Guide d'installation

Taper
Guide d'installation

dans d''autres langues