CARLO GAVAZZI WSM2BA2D24 Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur

Ce manuel convient également à

W
ireless Entrapment Protection Device
Drahtlose Einschließ-Schutzeinrichtung
Système sans fil pour barre palpeuse
WSM 2BA2D24 / WSS 2BA2BAT
MAN WSM/WSS ENG_GER_FRA rev.01-02.2012
15-029-464
CARLO GAVAZZI INDUSTRI A/S
Over Hadstenvej 40, DK-8370 Hadsten
Phone: +45 89 60 61 00
Fax: +45 86 98 25 22
www.gavazziautomation.com
Certified in accordance with ISO 9001
Zertifiziert nach ISO 9001
Certifiée conforme ISO 9001
E
nglish - Deutsch - Français
User Manual
B
enutzerhandbuch
Manuel utilisateur
IC compliance statements
GB
"
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this devicemust
accept any interference, including interference that may cause undesired operation of the de-
v
ice.""Under Industry Canada regulations, this radio transmitter may only operate using an an-
t
enna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
To reducepotential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary
f
or successfulcommunication.""This device complies with Industry Canada RF radiation exposure
limits for general population. It must not be collocated or operating in conjunction with any other
antenna or transmitter"
F
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils ra-
d
ioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillagera-
dioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
C
onformément à la réglementation d'Industrie Canada, le présent émetteur radio peutfonctionner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pourl'émetteur par In-
dustrie Canada. Dans le but de réduire les risques de brouillage radioélectriqueà l'intention des
a
utres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que lapuissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire àl'établissement d'une com-
munication satisfaisante
Con
f
i
gu
r
a
t
i
on
de
s
c
a
n
a
u
x
(
c
on
t
r
ôl
e
u
r
m
a
î
t
re
e
t
e
s
c
l
a
v
e
)
F
C
onfigurer le canal radio du contrôleur maître et esclave, avec les lecteurs DIP 1,2, 3 et 4.
Il existe 16 canaux distincts nurotés de 1 à 16.
C
anal désiré = (Dip1)*1+(Dip2)*2+(Dip3)*4+(Dip4)*8+1
Exemple:
S
i le canal désiré est le 12, configurer les sélecteurs DIP comme suit
Canal désiré = (1)*1+(1)*2+(0)*4+(1)*8+1 = 12
Entrée de test niveau haut/bas (contrôleur maître)
L'entrée de test sur le contrôleur maître sert au système sans fil. Lorsque le système est actif, il
surveille la barre palpeuse.
L
'entrée de test peut être activée par un signal haut ou bas niveau, selon les paramètres du
sélecteur DIP switch 5.
L
es canaux Zigbee et Wi-fi se
situent dans la même bande de
fréquence. C'est pourquoi, les
réseaux WiFi avoisinants peu-
vent créer des interférences
a
vec certains canaux zigbee.
Les canaux suivants évitent les
interférences WiFi :
5, 10, 15 et 16
4 8
3 4
2 2
1 1
DIP switches
OFF
ON
Channals 1-16 Selector
Min 100 ms
0 V
1
2-24 V
1
2-24 V
0 V
Min 100 ms
DC AC
High Low
M
in 100 ms
0 V
1
2-24 V
Min 100 ms
0 V
12-24 V
TEST INPUT HIGH/LOW.
ON
OFF
OFF
DIP switch
Canal
1 2 3 4
O
FF
O
FF
O
FF
O
FF
1
ON OFF OFF OFF 2
OFF ON OFF OFF 3
ON ON OFF OFF 4
OFF OFF ON OFF 5
ON OFF ON OFF 6
O
FF
O
N
O
N
O
FF
7
ON ON ON OFF 8
OFF OFF OFF ON 9
ON OFF OFF ON 10
OFF ON OFF ON 11
ON ON OFF ON 12
OFF OFF ON ON 13
O
N
O
FF
O
N
O
N
1
4
OFF ON ON ON 15
ON ON ON ON 16
!
Une fois l'entrée test activée, le contrôleur esclave reste actif pendant le temps paramétré sur le
c
ontrôleur maître. Le temps d'activité correspond au temps de maintien du système en mode
actif. Ce temps est réglable de 10 à 80 secondes.
Bord sensible (contrôleur esclave)
Câblage et vérification de la barre palpeuse
C
ette partie du manuel détaille la procédure d'installation et de câblage d'un système pour barre
palpeuse incluant un contrôleur maître.
Durée d'activité (Contrôleur maître)
8 C
7 B
6 A
DIP switches
OFF
ON
Active time
Le contrôleur esclave comprend une entrée ESPE* NF, ESPE NO 8,2 kΩ ou le contact ESPE NF
d
es capteurs des cellules photoélectriques basse consommation. L'entrée de fin de course est
équipée d'un cavalier installé en usine. Cette entrée permet de surveiller le fin de course d'un
ensemble porte/portail.
*ESPE (équipements de sécurité électro sensibles)
8 EPD2: 8K2/NC
7
EPD2: PES/MEC
6 EPD1: 8K2/NC
5
EPD1: PES/MEC
DIP switches
OFF
ON
A B C Temps d'activité
OFF OFF OFF 10 Sec.
ON OFF OFF 20 Sec.
OFF ON OFF 30 Sec.
ON ON OFF 40 Sec.
OFF OFF ON 50 Sec.
O
N
O
FF
O
N
6
0 Sec.
OFF ON ON 70 Sec.
ON ON ON 80 Sec.
Contrôleur maître
Installer de préférence le contrôleur maître sur un mur, aussi haut que possible.
Avec le lecteur Dip switch, affecter au contrôleur maître, le canal radio désiré (1 à 16) et
p
aramétrer le mode d'entrée de test requis (haut vers bas ou bas vers haut). Sélectionner
également le temps d'activité voulu (10 – 80 s).
L
'entrée de test peut être directement raccordée au contrôleur de porte ou à faut, à un
contact.
S
i le système ne comprend pas de contrôleur de porte, câbler comme illustré ci-dessous afin
d'envoyer un signal d'entrée de test au contrôleur maître, via un contact.
Dans ce cas, le sélecteur DP switch 5 doit être positionné sur ON
Mise sous tension
Mettre le contrôleur maître sous tension. Les LED Alimentation et Charge Batterie du contrôleur
maître doivent clignoter à tour de rôle, indiquant qu'il n'est associé à aucun contrôleur esclave.
Ne pas installer le contrôleur principal près d'une borne
d'accès WiFi ; en effet le WiFi utilise la même bande de
fréquence que le système.
!
Ne pas installer le contrôleur maître dans un boîtier
métallique sous peine d'affecter la fonctionnalité de
l'antenne.
Les modifications non approuvées par la partie respons-
able peuvent annuler l'autorisation d'exploitation du
matériel accordée à l'utilisateur.
!
Câblage et vérification de la barre palpeuse
P
rocédure d'installation et câblage du contrôleur esclave.
Contrôleur esclave
Installé le contrôleur esclave sur la porte ou le portail.
Installer le contrôleur esclave aussi haut que possible.
A
vec le sélecteur Dip switch, affecter au contrôleur esclave le canal radio désiré (1 à 16) et le ou
les types de barres palpeuses voulues.
En cas d'utilisation d'une seule barre palpeuse, passer l'autre barre en mode inactif.
E
n cas d'association d'une porte et d'un portail, raccorder le fin de course au contrôleur esclave
(entrée normalement fermée).
Vérification
Raccorder au contrôleur esclave, le contact ESPE* NF, le
c
ontact ESPE N.O. 8.2 kΩ ou le contact ESPE NF de la
cellule photoélectrique basse consommation.
Raccorder un fin de course au contrôleur esclave dans le cas
d
'un ensemble porte/portail.
Appuyer brièvement sur le bouton-poussoir du contrôleur
esclave (0,5 s).
À
ce stade, les LED EPD1 et EPD2 indiquent l'état de la barre
palpeuse pour les 30 secondes à venir.
N
ota : si l'entrée fin de course n'est pas fermée ni son cava-
lier installé, les LED restent éteintes.
Tenter de court-circuiter les contacts ESPE* NF, ESPE 8.2 kΩ
N
O ou le contact ESPE NF de la cellule photoélectrique
basse consommation et constater un éventuel changement
de l'état de la LED dédiée.
A
près vérification, appuyer une fois sur le bouton-poussoir
pour quitter le mode Réglage.
*
ESPE (équipements de sécurité électro sensibles)
Procédure d'association (contrôleur maître et esclave)
1
. Appuyer plus de 3 secondes sur le bouton-poussoir du contrôleur maître jusqu'à ce que la
LED verte reste allumée en fixe et que la LED EPD2 clignote. À ce stade, le contrôleur maître
est en mode association prêt pour le raccordement aux contrôleurs esclaves.
2. Se rendre sur place et appuyer plus de 3 secondes sur le bouton-poussoir du contrôleur esclave.
À ce stade, le contrôleur esclave entre en mode association et la LED EPD2 clignote.
3. Après association, le contrôleur esclave, pilo par le contrôleur maître, quitte le mode
a
ssociation et les LED du contrôleur esclave cessent de clignoter.
4. En cas d'utilisation de plusieurs contrôleurs esclaves, répéter les opérations 2.
5. Une fois tous les contrôleurs esclaves associés, se rendre au contrôleur maître et appuyer
brièvement sur le bouton-poussoir pendant 0,5 s.
L
e contrôleur maître indique le nombre de contrôleurs esclaves raccordés.
Exemple :
Si deux contrôleurs esclaves ont été associés, deux LED doivent clignoter sur le contrôleu
m
aître.
6. Pour quitter le mode association, appuyer plus de 3 secondes sur le bouton-poussoir du
c
ontrôleur maître.
À ce stade, la procédure d'association est terminée et le système est prêt à l'exploitation.
Signalisation du niveau charge des batteries
L
es niveaux de charges des batteries sont signalés comme décrit ci-dessous:
Si la charge de la batterie de l'un des contrôleurs esclaves connectés est insuffisante, la LED
Low Batt clignote. Un relais dédié à l'insuffisance de charge signale également à l'utilisateur l'état
d
e la charge de la batterie.
En cas d'insuffisance de charge de la batterie, un contrôleur esclave l'indique comme suit :
La LED EPD1 clignote chaque seconde.
Contrôleur maître
Contrôleur esclave
Si les LED EPD1 et EPD2 du contrôleur esclave
clignotent à tour de rôle, la procédure d'associa-
t
ion a échoué.
Un échec d'association est dû à une interférence
sur le canal radio. Tenter de changer de canal
radio et reprendre à l'étape 1.
!
Questions fréquentes
1
. Pourquoi les LED verte et rouge clignotent elles à tour de rôle ?
Le contrôleur maître n'est associé à aucun contrôleur esclave.
2
. En mode association, le contrôleur maître n'indique pas le nombre de contrôleurs
esclaves associés malgré une brève sollicitation du bouton-poussoir. Pourquoi ?
Le contrôleur esclave n'a pas été associé. Tenter de modifier la fréquence du canal radio et
r
ecommencer la procédure d'association.
3. Le système reste inactif malgré l'envoi du signal d'entrée de test au contrôleur maître!
Vérifier les points suivants :
1. En se rendant sur place, constater que l’entrée fin de course de chaque contrôleur esclave
est fermé.
2. Appuyer brièvement sur le bouton-poussoir du contrôleur esclave pour passer en mode
Réglage. Observer la LED et constater le bon fonctionnement de la barre palpeuse active.
3. Assigner un canal différent aux contrôleurs maître et esclave.
4. Le dispositif de protection est parasité par une autre fréquence radio. Que faire dans ce cas?
Il suffit de commuter les contrôleurs maître et esclave sur un autre canal (il est inutile de
les réassocier).
Contrôleur maître
Contrôleur esclave
1. La LED EPD1 clignote chaque seconde. Quel est le problème ?
Remplacer la batterie.
2. Pourquoi, en mode association, les LED EPD1 et EPD2 clignotent elles à tour de rôle ?
Le canal radio est perturbé - tenter de changer de canal sur le contrôleur maître et sur le
contrôleur esclave.
3. Comment remplace-t-on les batteries ?
Appuyer sur le bouton-poussoir puis déposer les batteries. Ensuite, installer des batteries
neuves.
4. Que signifie ESPE ?
Équipement électro sensible de sécurité
5. Le dispositif de protection est perturbé par une autre fréquence radio. Que faut-il faire?
Il suffit de commuter le contrôleur maître et le contrôleur esclave sur un autre canal (il est
inutile de les réassocier).
Canaux 1-16 Sélecteur
DIP switch
OFF Sélecteur
ON
OFF sélecteur
ON
O
FF
Entrée haut/bas.
CC
Haut
CA
Bas
Temps d'activité
DIP switch
OFF sélecteur
I
nactive
Photoélectrique
ESPE NO 8,2 kΩ
E
SPE NF
Inactive
Photoélectrique
E
SPE NO 8,2 kΩ
ESPE NF
Porte dans la porte
DIP switch
OFF sélecteur
ON
Hauptcontroller
P
orte dans la porte
Contrôleur esclave
Ne pas installer le contrôleur esclave dans un
b
oîtier métallique sous peine d'affecter la fonc-
tionnalité de l'antenne.
Les modifications non approuvées par la partie
responsable peuvent annuler l'autorisation
d
'exploitation du matériel accordée à l'utilisa-
teur.
!
15-029-464_MAN WSM-WSS ENG_GER_FRA_15-029-464_MAN WSM-WSS ENG_GER_FRA 07/02/12 14.21 Page 1
Channel Setup (Main and Sub Controller) GB
In order to set the radio channel on main and sub controller use Dip 1, 2, 3 and 4.
T
here are 16 different channels from 1 to 16.
Desired channel= (Dip1)*1+(Dip2)*2+(Dip3)*4+(Dip4)*8+1
Example:
In case the desired channel is 12, the Dip switch setup should be
Desired channel= (1)*1+(1)*2+(0)*4+(1)*8+1 = 12
Test Input High/Low (Main Controller)
Test input on the main controller is used to the wireless system. When active the system monitors
the protection edge.
T
est input can be activated by a high or low signal level dependent on the DIP switch 5 settings.
Zigbee and Wi-fi channels are
p
laced at the same frequency
band. Therefore some of the
zigbee channels might be inter-
fered by nearby Wi-fi networks.
Channels with a better chance
o
f avoiding wi-fi interference
are: 5, 10, 15 and 16
4 8
3 4
2 2
1 1
DIP switches
OFF
ON
Channals 1-16 Selector
Min 100 ms
0 V
12-24 V
1
2-24 V
0 V
Min 100 ms
DC AC
High Low
M
in 100 ms
0 V
1
2-24 V
Min 100 ms
0 V
1
2-24 V
TEST INPUT HIGH/LOW.
O
N
OFF
OFF
D
ip switch
Chanel
1 2 3 4
OFF OFF OFF OFF 1
ON OFF OFF OFF 2
OFF ON OFF OFF 3
ON ON OFF OFF 4
OFF OFF ON OFF 5
ON OFF ON OFF 6
O
FF
O
N
O
N
O
FF
7
O
N
O
N
O
N
O
FF
8
OFF OFF OFF ON 9
ON OFF OFF ON 10
OFF ON OFF ON 11
ON ON OFF ON 12
O
FF
O
FF
O
N
O
N
1
3
ON OFF ON ON 14
OFF ON ON ON 15
ON ON ON ON 16
!
After the test input is activated the sub controller stays awake for the time set on the main
c
ontroller.
Active time is the period that the system stays in active mode. This time can be set from 10 to 80
seconds.
Protection Edge (Sub Controller)
Wiring and Verification of Protection Edge
T
his part of the manual explains the procedure for installation and wiring of the entrapment
protection system including main controller.
Active Time (Main Controller)
8 C
7 B
6 A
DIP switches
OFF
ON
Active time
The sub controller has input for either N.C. ESPE*, N.O. 8.2 kΩ ESPE or the low consumption
photoelectric ESPE N.C. sensors. There is also a Limit switch input, which is jumped from the
f
actory. This Limit switch input might be used to monitor a door in door switch.
*ESPE (electro-sensitive protective equipment)
A B C Active time
OFF OFF OFF 10 Sec.
ON OFF OFF 20 Sec.
O
FF
O
N
O
FF
3
0 Sec.
ON ON OFF 40 Sec.
OFF OFF ON 50 Sec.
ON OFF ON 60 Sec.
O
FF
O
N
O
N
7
0 Sec.
ON ON ON 80 Sec.
Main Controller
The main controller should be placed on a wall and the installation height should be as high as
possible.
Set the dip switch on the main controller, so that it uses the desired radio channel number (1 -16)
a
nd the required test input mode (Low to High or High to Low). In addition set the desired active
time (10 – 80 s).
T
est input can be connected directly to the door controller or connected to a contact, if no door
controller is used.
In case you do not have a door controller, then use the following wiring in order to send test input
to main controller using a contact.
In this case the Dip 5 must be in ON position.
Power ON
Set power to the main controller. The power and low batt LEDs should toggle on the main con-
troller in order to indicate that the device is not associated with any sub controllers.
The main controller should not be placed close to a Wi-Fi
access point, since Wi-Fi uses the same frequency band
a
s the system.
!
The main controller should not be placed inside a metal box.
This can affect the antenna functionality.
Changes/modifications not approved by the responsible party
could void the user’s authority to operate the equipment.
!
Wiring and Verification of Protection Edge
Procedure for installation and wiring of the sub controller.
Sub Controller
Mount the sub controller on the Door or gate. If possible place the sub controller as high as
possible.
S
et the Dip switch on the sub controller, so that it uses the desired radio channel number (1 -16)
and the desired entrapment protection device EPD type(s).
If only one EPD is used, then it is necessary to set the other EPD in Inactive mode.
I
f there is a door in door/gate, then connect the limit switch to the sub controller (n.c. input).
Verification
Connect N.C. ESPE*, N.O. 8.2 kΩ ESPE or the low
c
onsumption photoelectric ESPE N.C. contact to the sub
controller.
Connect a limit switch to the sub controller, if there is a door
i
n door/gate.
Press the push button on the sub controller shortly (½s). Now
the EPD1 and EPD2 LEDs show the status of entrapment
p
rotection for the next 30 s.
Note that if the limit swich input is not closed or jumped, then
t
he LEDs do not light. Try interrupting the N.C. ESPE*, N.O.
8.2 kΩ ESPE or the low consumption photoelectric ESPE N.C
and see if the status of dedicated LED changes. After verifi-
c
ation press the push button once more to exit the
adjustment mode.
*
ESPE (electro-sensitive protective equipment)
The sub controller should not be placed inside a metal
box. This can affect the antenna functionality.
!
C
hanges/modifications not approved by the respon-
sible party could void the user’s authority to operate
the equipment.
!
Association Procedure (Main and Sub Controller)
1
. Press the push button on the main controller for more than 3 s, until the green LED shines
continously and EPD2 starts blinking. The main controller is now in association mode, ready
to be connected to the sub controllers.
2. Go to the Sub controller and press the push button for more than 3 s. The sub controller now
enters association mode and LED EPD2 starts blinking.
3
. After association is finished, the main controller makes the sub controller leave the association
mode and the LEDs on the sub controller stop blinking.
4
. If more than one sub controller is used, then repeat step 2.
5. After having connected all sub controllers, continue to the main controller. Press the push
b
utton shortly (½ s). The main controllers show the number of connected sub controllers.
Example:
If you have associated two sub controllers then two LEDs should blink on the main controller.
6. Press the push button on the main controller for more than 3 s in order to exit the association
mode.
The association procedure is now finished and you can start using the system.
Low Battery Indication
L
ow battery status will be indicated as described here:
In case of a low battery status on one of connected sub controllers, the LED Low Batt will be
turned on. In addition, the relay dedicated to low battery will also inform about the Low battery
s
tatus.
The sub controller, that has a low battery status gives the following indication:
EPD1 LED flashes every 1 second.
Main Controller
Sub Controller
I
f LEDs EPD1 and EPD2 start toggling on the sub
controller, then the association procedure has been
aborted.
This is caused by a noisy radio channel. Try chang-
ing the radio channel and start from step 1.
!
Frequently Asked Questions
1. Why do the green and red LEDs toggle?
T
he main controller is not associated with any sub controller.
2. While in association mode, the main controller will not indicate the number of associated
s
ub controllers when pressing the push button shortly. What is the reason?
The sub controller has not been associated. Try changing the radio frequency channel and
r
estart the association procedure.
3. Sending test Input to the main controller does not get the system in active mode!
Check the following steps:
1. Go to every sub controller and check that the limit switch is closed.
2. Press the push button shortly on the sub controller to get the device in alignment mode.
Check if the active EPD works properly by verifing the LED.
3. Change the channel on the main and sub controller.
4. Protection Device is disturbed by another radio frequency. What do I do?
You simply switch the main and sub controller to another channel (you do not need to
associate the system again).
Main Controller
Sub Controller
1. EPD1 LED flashes every 1 s. What is wrong?
Battery should be changed.
2. Why are EPD1 and EPD2 toggling under association?
The RF channel is noisy - try changing it on the main and the sub controller.
3. How do I change the batteries?
Press the push button down and remove the batteries. Then replace them with new ones.
4. What ESPE stands for?
ESPE stands for Electro Sensitive Protective Equipment.
5. Protection Device is disturbed by another radio frequency. What do I do?
You simply switch the main and sub controller to another channel (you do not need to
associate the system again).
Kanalwahl (Haupt- und Nebencontroller) D
Der Funkkanal der Haupt- und Nebencontroller wird mithilfe der DIP-Schalter 1, 2, 3 und 4 festgelegt.
E
s stehen 16 verschiedene Kanäle mit den Nummern 1 bis 16 zur Verfügung.
Gewünschter Kanal = (DIP 1) × 1+(DIP 2) × 2+(DIP 3) × 4+(DIP 4) × 8+1
Beispiel:
Um Kanal 12 einzustellen, müssen die DIP-Schalter folgendermaßen geschaltet werden:
Gewünschter Kanal = (1) × 1+(1) × 2+(0) × 4+(1) × 8+1 = 12
Testeingang HIGH/ LOW Pegel (Hauptcontroller)
Der Testeingang am Hauptcontroller wird über das Funksystem übertragen. Wenn er aktiviert ist,
überwacht das System die Schließkante.
J
e nach Einstellung des DIP-Schalters 5 wird der Testeingang durch einen hohen oder einen
niedrigen Signalpegel ausgelöst.
Die Zigbee- und Wi-Fi-Kanäle
v
erwenden das gleiche
Frequenzband. Daher kann es
vorkommen, dass einige der
Zigbee-Kanäle durch in der
Nähe befindliche Wi-Fi-Netz-
w
erke gestört werden.
Bei folgenden Kanälen ist die
Wahrscheinlichkeit einer Stö-
rung durch Wi-Fi-Netzwerke
geringer: 5, 10, 15 und 16.
4 8
3 4
2 2
1 1
DIP switches
OFF
ON
Channals 1-16 Selector
M
in 100 ms
0
V
1
2-24 V
12-24 V
0 V
Min 100 ms
DC AC
High Low
Min 100 ms
0 V
12-24 V
Min 100 ms
0 V
12-24 V
TEST INPUT HIGH/LOW.
ON
OFF
OFF
D
IP-Schalter
Kanal
1 2 3 4
AUS AUS AUS AUS 1
AN AUS AUS AUS 2
AUS AN AUS AUS 3
AN AN AUS AUS 4
AUS AUS AN AUS 5
AN AUS AN AUS 6
A
US
A
N
A
N
A
US
7
A
N
A
N
A
N
A
US
8
AUS AUS AUS AN 9
AN AUS AUS AN 10
AUS AN AUS AN 11
AN AN AUS AN 12
A
US
A
US
A
N
A
N
1
3
AN AUS AN AN 14
AUS AN AN AN 15
AN AN AN AN 16
!
Nachdem der Testeingang aktiviert wurde, bleibt der Nebencontroller für die auf dem Hauptcon-
t
roller festgelegte Zeitdauer aktiv. Die Aktivierungsdauer ist der Zeitraum, für den das System im
aktiven Modus verbleibt. Für die Dauer dieses Zeitraums kann ein Wert zwischen 10 und 80
Sekunden festgelegt werden.
Schließkante (Nebencontroller)
Verkabelung und Überprüfung der Schließkanten
I
n diesem Teil des Handbuchs wird die Vorgehensweise zur Installation und Verkabelung der
Schließkantensicherung inklusive des Hauptcontrollers beschrieben.
Aktivierungsdauer (Hauptcontroller)
8 C
7 B
6 A
DIP switches
OFF
ON
Active time
Der Nebencontroller verfügt über Eingänge für den N.C.-ESPE*-Sensor, den N.O.-ESPE-
Sensor mit 8,2 kΩ und den photoelektrischen ESPE-N.C.-Sensor mit geringem
S
tromverbrauch. Des Weiteren verfügt das Gerät über einen Eingang für einen Endabschalter,
der in der Werkseinstellung überbrückt ist. Dieser Endabschaltereingang kann zur Überwachung
einer Personentür im Tor genutzt werden.
*ESPE (berührungslos wirkende Schutzeinrichtung)
8
EPD2: 8K2/NC
7
EPD2: PES/MEC
6 EPD1: 8K2/NC
5
EPD1: PES/MEC
D
IP switches
O
FF
ON
A B C Aktivierungsdauer
AUS AUS AUS 10 Sek.
AN AUS AUS 20 Sek.
A
US
A
N
A
US
3
0 Sek.
AN AN AUS 40 Sek.
AUS AUS AN 50 Sek.
AN AUS AN 60 Sek.
A
US
A
N
A
N
7
0 Sek.
AN AN AN 80 Sek.
Hauptcontroller
Der Hauptcontroller muss an einer Wand angebracht werden. Die Installationshöhe muss dabei
so hoch wie möglich sein.
Legen Sie mithilfe der DIP-Schalter am Hauptcontroller den gewünschten Funkkanal (1–16) und
d
en erforderlichen Testeingangsmodus (HIGH oder LOW Signal ) fest. Zusätzlich müssen Sie die
gewünschte Aktivierungsdauer einstellen (10–80 s).
D
er Testeingang kann direkt mit dem Türcontroller oder mit einem Kontakt verbunden werden,
falls kein Türcontroller verwendet wird.
Falls Sie keinen Türcontroller einsetzen, müssen Sie die Verkabelung nach dem folgenden
Schema vornehmen, um das Testeingangssignal bei Verwendung eines Kontaktschalters an den
Hauptcontroller zu übertragen.
In diesem Fall muss der DIP-Schalter 5 in die Position „AN“ geschaltet werden.
Einschalten
Schalten Sie die Stromversorgung des Hauptcontrollers ein. Die LED „Power“ und „Low Batt“
leuchten abwechselnd auf, um zu signalisieren, dass noch keine Nebencontroller am Gerät
angemeldet wurden.
Der Hauptcontroller darf nicht in der Nähe eines Wi-Fi-
Access-Points platziert werden, da Wi-Fi auf dem gleichen
F
requenzband wie die Einschließ-Schutzeinrichtung arbeitet.
!
Der Hauptcontroller darf nicht innerhalb eines
Metallgehäuses platziert werden. Dies kann die
Antennenleistung beeinträchtigen.
Änderungen bzw. Modifikationen, die ohne Zustimmung
der verantwortlichen Stelle vorgenommen werden,
können zum Verlust der Betriebserlaubnis führen.
!
Verkabelung und Überprüfung der Schließkanten
Im Folgenden wird die Vorgehensweise zur Installation und Verkabelung des Nebencontrollers
b
eschrieben.
Nebencontroller
Befestigen Sie den Nebencontroller an der Tür bzw. am Tor. Bringen Sie den Nebencontroller
dabei so hoch wie möglich an.
L
egen Sie mithilfe der DIP-Schalter am Nebencontroller den gewünschten Funkkanal (1–16) und
den bzw. die gewünschten EPD-Typ(en) (Entrapment Protection Device, Schließkantensicherung)
fest.
W
enn nur ein EPD verwendet wird, muss der andere EPD in den inaktiven Modus geschaltet werden.
Falls Sie eine Personentür im Tor mit einem NC Endschalter überwachen, verbinden Sie bitte den
NC Ausgang des Endschalters mit dem NC Eingang am Nebencontroller.
Überprüfung
Schließen Sie den N.C. ESPE*-Sensor, den N.O.-ESPE-Sen-
sor mit 8,2 kΩ oder den photoelektrischen ESPE-N.C.-Sen-
s
or mit geringem Stromverbrauch am Nebencontroller an.
Verbinden Sie den Endabschalter mit dem Nebencontroller,
falls Sie eine Personentür im Tor überwachen.
D
rücken Sie kurz den Drucktaster des Nebencontrollers (0,5
s). Die LED „EPD1“ und „EPD2“ zeigen nun 30 s lang den
Status der Schließkantensicherungen an.
Beachten Sie, dass die LEDs nicht aufleuchten, falls der End-
abschalter nicht geschlossen oder überbrückt ist. Versuchen
S
ie nun, den N.C. ESPE*-Sensor, den N.O.-ESPE-Sensor mit
8,2 kΩ oder den photoelektrischen ESPE-N.C.-Sensor mit
geringem Stromverbrauch zu unterbrechen, und überprüfen
S
ie, ob sich der Zustand der entsprechenden LED ändert.
Drücken Sie nach der Überprüfung erneut den Drucktaster,
um den Einstellungsmodus zu beenden.
*
ESPE (berührungslos wirkende Schutzeinrichtung)
Der Nebencontroller darf nicht innerhalb eines
M
etallgehäuses platziert werden. Dies kann die
Antennenleistung beeinträchtigen.
!
Änderungen bzw. Modifikationen, die ohne
Zustimmung der verantwortlichen Stelle
vorgenommen werden, können zum Verlust
der Betriebserlaubnis führen.
!
Anmeldevorgang (Haupt- und Nebencontroller)
1. Halten Sie den Drucktaster an der Haupteinheit mindestens 3 s lang gedrückt, bis die grüne
LED dauerhaft leuchtet und „EPD2“ zu blinken beginnt. Der Hauptcontroller befindet sich jetzt
i
m Anmeldemodus und kann mit den Nebencontrollern verbunden werden.
2. Begeben Sie sich nun zum Nebencontroller und halten Sie dessen Drucktaster mindestens 3 s
lang gedrückt. Der Nebencontroller wechselt zum Anmeldemodus, und die LED „EPD2
b
eginnt zu blinken.
3
. Nachdem die Verbindung hergestellt wurde, beendet der Hauptcontroller den Anmeldemodus
des Nebencontrollers, und die LEDs am Nebencontroller blinken nicht länger.
4
. Wenn Sie mehr als einen Nebencontroller verwenden, wiederholen Sie Schritt 2.
5. Begeben Sie sich wieder zum Hauptcontroller, nachdem Sie alle Nebencontroller angemeldet
h
aben. Drücken Sie den Drucktaster kurz (0,5 s). Am Hauptcontroller wird die Anzahl der
angemeldeten Nebencontroller angezeigt.
Beispiel:
W
enn Sie zwei Nebencontroller angemeldet haben, sollten am Hauptcontroller zwei LED
blinken.
6
. Drücken und halten Sie den Drucktaster am Hauptcontroller mindestens 3 s lang, um den An
meldemodus zu beenden.
D
er Anmeldevorgang ist nun abgeschlossen, und Sie können mit der bestimmungsgemäßen
Nutzung des Systems beginnen.
Anzeige für niedrigen Batterieladestand
Ein niedriger Batterieladestand wird, wie im Folgenden beschrieben, signalisiert:
W
enn einer der verbundenen Nebencontroller einen niedrigen Batterieladestand aufweist, wird
die LED „Low Batt“ aktiviert. Zusätzlich wird das dem niedrigen Batterieladestand zugeordnete
Relais aktiviert.
A
m Nebencontroller, dessen Batterieladestand niedrig ist, wird Folgendes angezeigt:
Die LED „EPD1“ blinkt im Sekundentakt.
Hauptcontroller
Nebencontroller
Wenn die LED „EPD1“ und „EPD2“ am Nebencon-
troller abwechselnd zu leuchten beginnen, wurde
der Anmeldevorgang abgebrochen.
D
ies wird durch Störungen des Funkkanals verur-
sacht. Wählen Sie in diesem Fall einen anderen
Funkkanal, und fahren Sie mit Schritt 1 fort.
!
Häufig gestellte Fragen
1. Warum leuchten die grüne und die rote LED abwechselnd auf?
Dies bedeutet, dass der Hauptcontroller mit keinem Nebencontroller verbunden ist.
2. Wenn sich der Hauptcontroller im Anmeldemodus befindet, wird bei kurzem Drücken
des Drucktasters nicht die Anzahl der verbundenen Nebencontroller angezeigt. Warum
nicht?
Der Nebencontroller wurde nicht angemeldet. Wählen Sie einen anderen Funkkanal, und
führen Sie den Anmeldevorgang erneut durch.
3. Beim Senden des Testeingangs an den Hauptcontroller wird das System nicht aktiviert!
Führen Sie folgende Schritte aus:
1. Überprüfen Sie an allen Nebencontrollern, ob der Endschalter geschlossen ist.
2. Drücken Sie kurz den Drucktaster des Nebencontrollers, um das Gerät in den Einstel
lungsmodus zu versetzen. Stellen Sie sicher, dass der aktive EPD ordnungsgemäß
funktioniert, indem Sie die LED überprüfen.
3. Wechseln Sie den Kanal am Haupt- und Nebencontroller.
4. Die Schutzeinrichtung wird durch eine andere Funkfrequenz gestört. Was kann ich tun?
Wechseln Sie einfach am Haupt- und Nebencontroller auf einen anderen Kanal (der
Anmeldevorgang muss nicht erneut durchgeführt werden).
Hauptcontroller
Nebencontroller
1. Die LED „EPD1“ blinkt im Sekundentakt. Was stimmt nicht?
Die Batterie muss ausgetauscht werden.
2. Warum leuchten „EPD1“ und „EPD2“ während der Anmeldung abwechselnd?
Der Funkkanal ist verrauscht. Wählen Sie am Haupt- und Nebencontroller einen anderen Kanal
aus.
3. Wie kann ich die Batterien wechseln?
Drücken und halten Sie den Drucktaster, und entnehmen Sie die Batterien. Setzen Sie dann
die neuen Batterien ein.
4. Was bedeutet ESPE?
ESPE steht für berührungslos wirkende Schutzeinrichtung (Electro Sensitive Protective
Equipment).
5. Die Schutzeinrichtung wird durch eine andere Funkfrequenz gestört. Was kann ich tun?
Wechseln Sie einfach am Haupt- und Nebencontroller auf einen anderen Kanal (der Anmelde-
vorgang muss nicht erneut durchgeführt werden).
Auswahl der Kanäle 1–16
DIP-Schalter
AUS
AN
AUS
AN
AUS
Testeingang HIGH/ LOW Pegel
D
C
Hoch
A
C
Niedrig
Aktivierungsdauer
DIP-Schalter
AUS
AN
Inaktiv
Photoelektrisch
N.O.-ESPE, 8,2 kΩ
N.C.-ESPE
Inaktiv
Photoelektrisch
N.O.-ESPE, 8,2 kΩ
N.C.-ESPE
AN AN
A
US
A
US
AUS AN
AN AUS
AN AN
AUS AUS
A
US
A
N
AN AUS
Tür im Tor
DIP-Schalter
AUS
A
N
Hauptcontroller
T
ür im Tor
N
ebencontroller
15-029-464_MAN WSM-WSS ENG_GER_FRA_15-029-464_MAN WSM-WSS ENG_GER_FRA 07/02/12 14.21 Page 2
  • Page 1 1
  • Page 2 2

CARLO GAVAZZI WSM2BA2D24 Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur
Ce manuel convient également à