Chief OMNDBF55 Guide d'installation

Catégorie
Mur
Taper
Guide d'installation

Ce manuel convient également à

I N S T A L L A T I O N I N S T R U C T I O N S
Bolt-Down Stand
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
OMNDBF46-55
OMNDBF46-55 Installation Instructions
2
DISCLAIMER
Legrand | AV and its affiliated corporations and subsidiaries
(collectively “Legrand | AV”), intend to make this manual
accurate and complete. However, Legrand | AV makes no claim
that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Legrand | AV
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Legrand | AV
assumes no responsibility for accuracy, completeness or
sufficiency of the information contained in this document.
Chief® is a registered trademark of Legrand AV Inc.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems
are properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this mounting system can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to
make sure the structure to which this mounting system is
attached can support five times the combined weight of all
equipment. Reinforce the structure as required before
installing the mounting system.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the mounting system does not
exceed 80 lbs (36.3 kg) for the OMNDBF46 or 100 lbs (45.3
kg) for the OMNDBF55.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this mounting system outdoors.
WARNING: Do NOT install OMNDBF46/55 mounts to any
surface other than concrete or wood!
Concrete flooring must be at least 4" in thickness
and NOT be covered with any other type of
flooring material. Concrete anchors must be
installed directly into concrete surface.
Wood flooring must be at least 1 1/2" in total
depth which may include the subfloor.
--SAVE THESE INSTRUCTIONS--
Installation Instructions OMNDBF46-55
3
DIMENSIONS
915.09
36.0
2178.05
85.8
2227.80
87.7
6.25
740.96
29.2 10.16
.4
39.37
1.6
127
5.0
127
5.0
OMNDBF55
36.1
916.0
80.2
2037.5
25.0
634.6
A
1.90
48.3
2.75
69.9
CABLE ACCESS
REMOVABLE POST
CAP FOR CABLE
ACCESS
5.0
127.0
5.0
127.0
0.40
10.2
6.25
158.7
1.55
39.4
DETAIL A
SCALE 1 : 8
46" SAMSUNG OMN
DISPLAY SHOWN
NOT INCLUDED
OMNDB46
OMNDBF46-55 Installation Instructions
4
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Remove
Quitar
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Installation Instructions OMNDBF46-55
5
TOOLS REQUIRED FOR INSTALLATION
PARTS
25/64" (10mm) - concrete
1/2" (12.7mm)
3/16"
7/32" (5.5mm) - wood
(concrete only)
A (2)
[Floor post]
B (4)
[Bolt hole cap]
C (2)
[Pipe cap] D (2)
[Post cover]
E (4)
M8x20mm F (8)
5/16"
G (8)
5/16 x 2 1/2" H (8)
UX10x60R
J (1)
3/16"
OMNDBF46-55 Installation Instructions
6
Assembly And Installation
1. Slide two post covers (D) onto two floor posts (A). (See
Figure 1)
Figure 1
2. Use four M8x20mm button head cap screws (E) to attach
floor posts (A) to display. (See Figure 2)
Figure 2
3. Using floor post bases (A) as templates, mark four holes at
outside hole locations for each column. (See Figure 3)
WARNING: Do NOT install OMNDBF46/55 mounts to any
surface other than concrete or wood! Concrete flooring must
be at least 4" in thickness and NOT be covered with any other
type of flooring material. Concrete anchors must be installed
directly into concrete surface. Wood flooring must be at least
1 1/2" in depth which may include the subfloor.
IMPORTANT ! : Make sure columns will be installed far
enough away from any walls so that displays may be
installed.
4. Using a 25/64" (10mm) (CONCRETE) or a 7/32" (5.5mm)
(WOOD) drill bit, drill a hole 3 1/2” in depth at each marked
location. (See Figure 3) and (See Figure 4)
5. Blow each hole clean of any debris with a large air hose or
compressed air in a can. (See Figure 3) and (See Figure 4)
6. (CONCRETE ONLY) Use a hammer to install concrete
anchors (H) into the drilled holes. (See Figure 3)
7. Place each floor post base (A) on top of installed anchors
(H) or drilled holes making sure holes on plate are aligned
with holes. (See Figure 3) and (See Figure 4)
8. Install four 5/16 x 2 1/2" hex head cap screws (G) through
5/16" washers (F) and into four anchors (H) or drilled holes
to secure each column base to floor. (See Figure 3) and
(See Figure 4)
9. Tighten each anchor by turning the head three to four turns
past finger tight. (See Figure 4)
Figure 3
Figure 4
(D) x 2
(A) x 2
1
1
(E) x 4
2
(A) x 2
x
x
x
x
xx
x
x
x
xx
3 4
10mm
8
(H) x 4
6
(G) x 4
(F) x 4
(concrete
only)
4
3/8
3 1/2” deep
5
air hose
(H) x 4
6
(A)
(G) x 4
8
(A)
(concrete only)
Installation Instructions OMNDBF46-55
7
10. Route cables as desired. See Cable Management Section
for details.
11. Snap post covers (D) over floor post bases. (See Figure 5)
Figure 5
12. Install top cover (included with television) onto display. (See
Figure 6)
13. Snap two pipe caps (C) into side covers. (See Figure 6)
14. Snap four bolt hole caps (B) into holes on side covers. (See
Figure 6)
Figure 6
Cable Management
1. Route cables through floor posts (A) as desired. (See
Figure 7)
Figure 7
(D) x 2
11
11
(C) x 2
(B) x 4
14
13
12
12
1
1
1
1
OMNDBF46-55 Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
8800-003156 Rev02
2019 Legrand | AV
www.legrandav.com
11/19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief OMNDBF55 Guide d'installation

Catégorie
Mur
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues