KE2 Case Controller Air Manuel utilisateur

Taper
Manuel utilisateur
KE2 Case Controller Display (Ethernet)
User Manual
The WiFi radio is normally off. To turn it on, connect the display to a display case controller. You can
connect the controller wired or wirelessly to a LAN or to a wired or wireless device. Once connected,
open a web browser and enter the IP address of the controller. Following is displayed:
To see other views, click on 3 bars in upper left corner:
Click on ‘Set Points’:
Then click on ‘Network’:
Under ‘Wireless Mesh’, select ‘Mesh Enabled’ to ‘Enabled’ and select the wireless channel that is
wanted. Then click on ‘Save’. If not logged in, controller will prompt you for Username and password:
For ‘Username’ enter ‘ke2admin’. For ‘Password’ enter KE2-CaseControl! And click on ‘Login’ Set
point changes should be saved and the wireless radio on the display should be turned on.
The Ethernet display will automatically discover any other Ethernet displays through the wifi. These
controllers can then be bonded and defrost queue as with a LAN connection.
The 4 digit alpha numeric display is used to display all variables and set points of the connected case
controller. The push buttons are used to maneuver through the various displays and to change any set
point of the display case controller.
FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer
could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.
ISED Statement
English: This device complies with Industry Canada licenseexempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not cause interference, a
nd (2) This device must accept any interference, including interference that may cause undesired
operation of the device.
The digital apparatus complies with Canadian CAN ICES3 (B)/NMB3(B).
French: Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradi
oélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement.
l'appareil numérique du ciem conforme canadien peut 3 (b) / nmb 3 (b).
This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and
compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure
and compliance.
cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du
cnr - 102 et conformité avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des
données canadiennes sur l'exposition aux champs rf et la conformité.
This equipment complies with Canada radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 20cm between the
radiator & your body.
Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement
non contrôlé.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le
radiateur et votre corps.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

KE2 Case Controller Air Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues