Premier Mounts P2642F Mode d'emploi

Catégorie
Supports muraux à panneau plat
Taper
Mode d'emploi
Installation Guide
P2642F
premiermounts.com | p. 800.368.9700 | e. [email protected]
500 W Central Ave, Suite A, Brea, CA 92821 USA
Warning Statements
Weight Limit
Maximum Flat Panel Weight: 130 lbs. THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING AT
LEAST FOUR TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, THE
WALL STRUCTURE MUST BE REINFORCED.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND COMPLETELY
UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED IN THESE
INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR
EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY
EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR
PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR
MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION
OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR
MODIFICATIONS.
If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs or ceiling studs.
It is recommended that a maximum of ⅝˝ plaster board be used when mounting to wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a water or gas line
may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.
AVERTISSEMENT
AVANT L’INSTALLATION DE CE PRODUIT, LES CONSIGNES D’INSTALLATION DOIVENT ÊTRE LUES ET PLEINEMENT COMPRISES.
CONSERVER CES CONSIGNES D’INSTALLATION DANS UN ENDROIT FACILEMENT ACCESSIBLE POUR RÉFÉRENCE FUTURE.
LA PROCÉDURE D’INSTALLATION CORRECTE PAR UN TECHNICIEN QUALIFIÉ DOIT ÊTRE OBSERVÉE, COMME DÉCRIT DANS
CES CONSIGNES D’INSTALLATION. FAUTE DE QUOI DES DOMMAGES MATÉRIELS, BLESSURES GRAVES, VOIRE MÊME LA MORT
PEUT SUBVENIR.
DES MESURES DE SÉCURITÉ DOIVENT ÊTRE PRATIQUÉES À TOUT MOMENT DURANT L’ASSEMBLAGE DE CE PRODUIT.
UTILISER L’ÉQUIPEMENT ET OUTILS DE SÉCURITÉ APPROPRIÉ POUR LA PROCÉDURE D’ASSEMBLAGE AFIN D’ÉVITER DES
BLESSURES.
LES SUPPORTS PREMIER MOUNTS NE GARANTISSENT PAS CONTRE LES DOMMAGES CAUSÉS PAR L’USAGE DU PRODUIT
DE MONTAGE PREMIER MOUNTS À D’AUTRES FINS QUE CELLES POUR LESQUELLES IL A ÉTÉ CONÇU OU DES DOMMAGES
CAUSÉS PAR DES ACCESSOIRES OU DES MODIFICATIONS NON AUTORISÉS, ET NOUS NE POUVONS PAS ÊTRE TENUS
RESPONSABLES DES DOMMAGES, PLAINTES, RÉCLAMATIONS, POURSUITES, ACTIONS OU CAUSES D’ACTION DE N’IMPORTE
QUELLE MANIÈRE RÉSULTANT DE, DÉCOULANT DE OU TOUCHANT DE N’IMPORTE QUELLE MANIÈRE UN TEL USAGE,
ACCESSOIRE OU MODIFICATION
Au moins deux pe s
matériels dû à la chute ou à la manipulation incorrecte de l’écran plat.
Si le montage s’effectue sur des rivets, assurez-vous que les vis de montage sont ancrées au centre des rivets. L’usage d’un détecteur de
rivet bord-à-bord est recommandé.
Il est recommandé qu’un maximum de plaque-plâtre de 5/8" soit utilisé lors d’un montage sur des rivets à bois.
Familiarisez-vous avec l’environnement de montage. Si un perçage et/ou une coupe est opéré sur la surface de montage, assurez-vous
S’assurer qu’il n’y a pas de canalisation d’eau ou de gaz naturel dans le mur où le montage doit être localisé. Une coupe ou un perçage
dans une canalisation d’eau ou de gaz naturel peut causer des dommages matériels ou des blessures graves.
Ce produit n’est destiné qu’à être utilisé à l’intérieur. L’utilisation de ce produit à l’extérieur pourrait entraîner des défauts matériels et/ou des
blessures graves.
Ne pas installer près de sources de forte chaleur. Ne pas installer sur une structure soumise aux vibrations, aux mouvements ou aux chocs.
Page 2
Installation Guide
P2642F
5/16” x 3” Lag Bolts
(Qty 4)
Thread Depth Indicator
(Qty 1)
Universal Spacers
(Qty 8)
Lock-it Barrel
(Qty 1)
Finned Anchor
(Qty 4)
5/16” Flat Washers
(Qty 4)
Universal Washers
(Qty 4)
Pencil Protective Eyewear
Electronic Stud Finder M6 or 1/4” Drill Bit 3/8” Masonry Drill Bit
Portable DrillPhillips Head Screwdriver Socket Wrench
13mm or 1/2” SocketLevel
M4 x 12mm (Qty 4)
M4 x 16mm (Qty 4)
M4 x 25mm (Qty 4)
M6 x 12mm (Qty 4)
M6 x 16mm (Qty 4)
M6 x 25mm (Qty 4)
M8 x 12mm (Qty 4)
M8 x 16mm (Qty 4)
M8 x 25mm (Qty 4)
Wall Mount
(Qty 1)
Bracket
(Qty 2)
M6 x 75 mm
(Qty 4)
Included Components
Required for installation
Page 3
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
2
3
1
XX
Wood Stud Installation
Introduction
1) Place the wall plate against the wall in the desired viewing location.
2) Use a pencil to mark the upper right mounting location along the center of
the wall stud.
Directional Mounting Arrow
The Directional Mounting Arrow stamped into the top of the P2642F wall
mount indicates which edge is the top.
You must secure the wall plate to two (2) wall studs with a minimum of four (4) lag bolts
(2 lag bolts for each stud found).
2) Use a pencil to mark the center of each of the wall studs.
Vous devez assembler la sablière sur deux (2) rivets de mur avec un minimum
de quatre (4) tirefonds (2 tirefonds pour chaque rivet trouvé).
Minimum of 2 by 4 wood stud to be used
Minimum de 2 par 4 bois goujon pour être utilisé
Drill a “pilot hole” in the center of the upper right mark using a 1/4” drill bit and
power drill.
Only use a 1/4″ drill bit when drilling the pilot holes.
N’utiliser qu’un foret de 1/4˝ lors du forage de guidage.
Page 4 premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
6
7
5
4
Éviter de trop serrer le tirefond.
1) Place the wall plate against the wall and align it with the pilot hole.
2) Insert one (1) 5/16″ x 3″ lag bolt and one (1) 5/16″ washer into the
up per right mounting hole and tighten using a socket wrench and 1/2” socket.
Do not overtighten the lag bolt.
1) Level the wall plate.
2) Use a pencil to mark the remaining three (3) mounting locations along the
Center of each wall stud.
Two people are recommended for this step; one person to level the wall
plate and another person to drill the pilot holes.
Drill a “pilot hole” in the center of each of the marks with a power drill and a 1/4″
drill bit.
Only use 1/4″ drill bit when drilling the pilot holes.
Il est recommandé deux personnes pour cette étape : une per-
sonne pour niveler la sablière et une autre personne pour percer
le forage de guidage.
N’utiliser qu’un foret de 1/4” lors du forage de guidage.
mur. Une installation incorrecte peut entraîner des blessures ou
des dommages matériels.
1) Insert one (1) 5/16” x 3” lag bolt and one (1) 5/16” washer into each pilot hole.
2) Tighten all lag bolts using a socket wrench and 1/2” socket.
Do not overtighten the lag bolts when attaching the mount to the wall. Improper
Installation may result in personal injury or property damage.
Page 5
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
10
11
9
8
Concrete Installation
Two people are recommended for this step: one person to level the wall
plate and another person to mark the mounting locations.
Il est recommandé deux personnes pour cette étape : une personne pour
niveler la sablière et une autre personne pour marquer les emplacements
de montage.
Drill four (4) pilot holes of each mark using a drill and 3/8” masonry drill bit.
Drill 3 inches deep.
Only use a 3/8" masonry drill bit when drilling pilot holes.
N’utiliser qu’un foret de 3/8” lors du forage de guidage.
Insert the Finned Anchors into each pilot hole.
Lightly tap each Finned Anchors into place with a hammer.
1) Insert one (1) 5/16” x 3” Lag Bolt and one (1) 5/16” washer into each
pilot hole.
2) Tighten all lag bolts using a socket wrench and 1/2” socket.
mur. Une installation incorrecte peut entraîner des blessures ou des
dommages matériels.
Do not overtighten the lag bolts when attaching the mount to the
wall. Improper installation may result in personal injury or property
damage.
Page 6 premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
1) Insert a small straw or toothpick into the threaded inserts found on the
2) Use a pencil to mark the depth of the threaded insert on the small straw
or toothpick.
3) Mark the straw or toothpick 1/8” above the depth of the threaded insert,
as shown in Figure 1.
4) Insert the small straw or toothpick into the remaining threaded inserts
to compare and verify their depth using the straw or toothpick’s 1/8”
allowance mark.
5) Locate the correct diameter screw for the threaded insert.
If the screw you selected is longer than the 1/8” allowance mark on
the small straw or toothpick, as shown in Figure 2 and Figure 3, do
not use this screw. The screw length must not bypass the mark.
6) Test each size of the screws provided.
The correct screws should thread easily into themounting point and
not pull out when tension is applied.
Small Straw or Toothpick
Marking the 1/8”
Allowance
Small Straw
or Toothpick Small Straw
or Toothpick Depth Plus 1/8” Allowance
Mark
Depth Plus 1/8” Allowance
Mark
Selecting the Mounting Hardware
Si la vis que vous sélectionnez est plus longue que la marque du
jeu maximal de 1/8” sur le paillon ou le cure-dents, comme illustré
sur le schéma 2 et le schéma 3, veuillez ne pas utiliser cette vis. La
longueur de la vis doit dévier la marque.
Page 7
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
Universal Washer Installation
Universal Spacer Installation
1˝ ¼˝
M8
M5, M6
M4
Premier Mounts’ Universal Washers are designed to accommodate the various
Do not place excess
The Universal Washer must be installed between the head of the
mounting screw and the mounting bracket as shown.
Recessed mount points?
Uneven mount points?
A curved back?
Any obstruction near the mount point?
If Yes, you must install Universal Spacers. Remove the mounting brackets,
Proceed to the “Universal Spacer Installation” section.
If No, skip to the “Leveling and Locking Screw Installation” section.
Éviter de placer une pression excessive à l’arrière de l’écran plat, car
cela risque d’endommager votre écran plat.
La rondelle tous usages doit être installée entre le chapeau de la vis de
Votre écran plat est-il muni de :
Points de montage encastrés ?
Points de montage inégaux ?
Un plan arrière arrondi ?
Une obstruction à l’emplacement du point d’assemblage ?
Si Oui, il vous faut installer des entretoises tous usages. Aller à la section
« Installation d’entretoise tous usages ».
Si non, aller à la section « Verrouillage et mise à niveau de l’installation de
la vis ».
Premier Mounts’ Universal Spacers allow you to attach the mounting bracket
panel.
The Universal Spacers must be stacked and oriented as shown.
The Universal Spacers must only be installed between the mounting
Proceed to the “Locking and Leveling Screw Installation” section.
Les entretoises tous usages doivent être empilées et orientées
comme illustré.
Les entretoises tous usages ne doivent être installées qu’entre le
support de montage et votre écran plat.
Flat Panel
Universal Washer
Universal Spacer
Mounting Bracket
Mount Point
Mounting Screw
Page 8 premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
Locking and Leveling Screw Installation
Leveling Screw Installation
You must install the leveling screws before you attach the mounting
(2) M6 x 75mm screws.
Thread one (1) leveling screw into the top mounting hole on each of the
mounting brackets. Make sure the leveling screw is securely threaded into the
mounting tab before proceeding.
Do not thread the leveling screw any further once it is even with the
mounting tab. Threading the leveling screw any further will prevent you
Locking Screw Installation
You must install the locking screws before you attach the mounting
(2) M6 x 75mm screws.
Thread one (1) locking screw into the bottom mounting hole on each of the
mounting brackets. Make sure the locking screw is securely threaded into the
mounting tab before proceeding.
Do not thread the locking screw any further once it is even with the
mounting tab. Threading the locking screw any further will prevent you
de montage à l’arrière de l’écran plat. Les vis de réglage se
composent de deux (2) vis de M6 x 75 mm.
sur la sablière.
la sablière.
support de montage à l’arrière de l’écran plat. Les vis de
blocage comportent deux (2) vis M6 x 75 mm.
Locking Screw
Correctly Threaded
Locking Screw
Threaded Too Far
Leveling Screw
Correctly Threaded
Leveling Screw
Threaded Too Far
Page 9
premiermounts.com | p. 800.368.9700 | e. [email protected]
Installation Guide
P2642F
Lock-it™ Security Barrel Installation (Optional)
Attaching the Mounting Bracket to the Flat Panel
Do not overtighten the locking screw.
Please read the following directions to install the security barrel:
1) Remove the locking screw from the mounting bracket.
2) Place the locking screw into and through the security barrel (see illustration below).
3) Re-insert the locking screw and security barrel into the mounting bracket.
4) Tighten the locking screw and security barrel until seated in the mounting tab.
clude:
- PCB-CSL1 (sold separately)
- Padlock (Combination or Keyed; commercially
available)
Lock-It™ Security
Barrel
Locking Screw
Do not thread the locking screw any further once it is even with the
mounting tab (see illustration to the right). Threading the locking screw
wall plate.
Mounting Tab
Proceed to the “Attaching the Mounting Bracket to the Flat Panel”
section.
sablière.
Éviter de trop serrer la vis de blocage.
This section presumes that you have read and understood these sections:
Selecting the Proper Mounting Hardware
Universal Washer Installation
Universal Spacer Installation
2) Identify the number and location of the thread inserts on the back of your
3) Aligning the holes on each mounting bracket with the thread inserts on the
two (2) screw per bracket.
Do not overtighten the mounting hardware.
Proceed to the “Attaching the Flat Panel to the Wall Plate” section.
Éviter de trop serrer le dispositif de montage.
Page 10
premiermounts.com | p. 800.368.9700 | e. [email protected]
Attaching the Flat Panel to the Wall Plate
Mounting Bracket Adjustment
Leveling Screw Adjustment
Locking Screw Adjustment
P2642F
Installation Guide
This section requires two people.
Do not release your
brackets are securely seated on the upper and lower mounting rails of the wall panel.
3) Engage the top and bottom mounting brackets to the rails of the wall plate.
Proceed to the “Mounting Bracket Adjustments” section.
Cette section exige deux personnes.
Éviter de relâcher votre écran plat jusqu’à ce que vous vous assuriez que les crochets
de haut et de bas de tous les deux supports de montage sont bien posés sur les rails
de montage hauts et bas de la sablière.
M6 x 75mm
Locking Screw
(1 per Bracket)
M6 x 75mm
Leveling Screw
(1 per Bracket)
compensate for this tilt by simply adjusting the screws with a screwdriver.
1) Loosen both locking screws.
3) Tighten both locking screws.
Caution!
Use extreme caution until you tighten the locking screws.
Attention !
C’est possible de retirer votre écran plat pendant son réglage. User d’une extrême
prudence jusqu’au moment du serrage des vis de blocage.
locking screws.
Do not overtighten the locking screws.
Éviter de trop serrer les vis de blocage.
Page 11
premiermounts.com | p. 800.368.9700 | e. [email protected]
Ultilizing the Security Barrel
Installation Guide
P2642F
Your P2642F Mount includes one (1) Security Barrel which can provide
PCB-CSL1 Security Cable -
Thread the cable through the hole on the security
barrel.
Attach the PCB-CSL1 locking mechansim and
secure it using the supplied key.
Padlock -
Place the locking hook through the hole of the
security barrel.
Snap lock and locking hook together.
Padlock
(Combination or Keyed)
PCB-CSL1
Page 12 premiermounts.com | p. 800.368.9700 | e. [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Premier Mounts P2642F Mode d'emploi

Catégorie
Supports muraux à panneau plat
Taper
Mode d'emploi

dans d''autres langues