Microlife BPB6 Manuel utilisateur

Catégorie
Unités de pression artérielle
Taper
Manuel utilisateur
IB BP B6 Connect S-V11 4023
Revision Date: 2023-09-05
BPB6 Connect
Bluetooth® Blood Pressure Monitor
EN
ES
1
12
FR
IT
24
36
DE
TR
48
60
PT
NL
71
83
GR
AR
95
108
FA 118
B6 Connect
Preparation
Sit on a back-supported chair and keep your legs uncrossed. / Siéntese en una silla con
respaldo y mantenga las piernas descritas. / Asseyez-vous sur une chaise (avec dossier)
et ne croisez pas les jambes. / Sedere su una sedia con schienale e non accavallare le
gambe. / Setzen Sie sich auf einen Stuhl mit Rückenlehnen und kreuzen Sie die Beine
nicht. / Arkası destekli bir sandalyeye oturunuz ve bacak bacak üzerine atmayınız. /
Sente-se numa cadeira com encosto e não cruze as pernas. /
Ga op een stoel zitten
met rugleuning en kruis uw benen niet. / Καθίστε σε καρέκλα με πλάτη και
μην σταυρώνετε τα πόδια σας. /
1.
3.
5.
2.
4.
6.
Fit the cuff closely, but not too tight. / Ajuste el brazalete de cerca, pero no demasiado
apretado. / Ajustez le brassard mais ne pas trop serrer. / Indossare il bracciale e
stringerlo, ma non troppo. / Legen Sie die Manschette eng aber nicht zu stramm an.
/ Manşonu yakın bir şekilde kapatınız ancak çok sıkmayınız. / Aperte corretamente
a braçadeira, mas não demasiado.
/ Breng de manchet aan rondom uw arm,
maar niet te strak. / Τοποθετήστε την περιχειρίδα εφαρμοστά αλλά όχι πολύ
σφιχτά. /
Avoid thick or close-fitting garments on the upper arm. / Evite prendas gruesas o
ajustadas en la parte superior del brazo. / Évitez les vêtements épais ou ajustés sur
le haut du bras. / Evitare di indossare abiti pesanti o aderenti intorno al braccio. /
Vermeiden Sie dicke oder eng anliegende Kleidungsstücke am Oberarm. / Kolun üst
kısmında sıkan ve dar giysilerden uzak durunuz. / Evite usar roupa grossa ou justa no
braço. / Vermijd dikke of strak zittende kleding aan uw bovenarm.
/ Αποφύγετε να
φοράτε χοντρά ή στενά ενδύματα στο μπράτσο σας. /
Place the artery-mark on the cuff over your artery. / Coloque la marca de la arteria en
el brazalete sobre su arteria. / Placez le repère d'artère du brassard au niveau de votre
artère. / Posizionare l’indicatore giallo dell’arteria posto sul bracciale in corrispondenza
dell’arteria del braccio./ Platzieren Sie die Arterienmarkierung auf der Manschette über
Ihrer Arterie. / Manşonun üzerindeki arter işaretinini, kolunuzun üzerindeki artere denk
getiriniz. / Coloque a marca existente na braçadeira sobre a artéria do braço. / Plaats
de manchet met arteriemarkering op uw arterie. / Τοποθετήστε την ένδειξη αρτηρίας
που βρίσκεται στην περιχειρίδα πάνω από την αρτηρία σας. /
Position the cuff 1-2 cm above your elbow. / Coloque el brazalete 1-2 cm por
encima del codo. / Installez le brassard 1 à 2 cm au dessus de la pliure du coude.
/ Posizionare il bracciale 1-2 cm sopra il gomito. / Positionieren Sie die Manschette
1-2 cm über Ihrem Ellbogen. / Manşonu dirseğinizden 1-2 cm yukarıya yerleştirin. /
Coloque a braçadeira 1-2 cm acima do cotovelo
. / Positioneer de manchet 1-2
cm boven uw elleboog. / Τοποθετήστε την περιχειρίδα 1-2 εκατοστά πάνω
από τον αγκώνα σας. /
Keep your arm still and do not speak during the measurement. / Mantenga su
brazo quieto y no hable durante la medición. / Ne pas parler et ne pas bouger votre
bras pendant la prise de mesure. / Tenere il braccio fermo e non parlare durante la
misurazione. / Halten Sie Ihren Arm ruhig und sprechen Sie während der Messung
nicht. / Kolunuzu sabit tutunuz ve ölçüm sırasında konuşmayınız. / Mantenha o braço
imóvel e não fale durante a medição. / Houd uw arm stil en spreek niet tijdens de
meting. / Κρατήστε το χέρι σας ακίνητο και μην μιλάτε κατά τη διάρκεια της μέτρησης.
/




/





1-2

- 


Microlife AG
Espenstrasse 139
9443 Widnau
Switzerland
www.microlife.com
Microlife UAB
P. Lukšio g. 32
08222 Vilnius
Lithuania
EMBALLAGE
Microlife BP B6 ConnectMicrolife BP B6 Connect Guarantee CardBefore each measurementMicrolife BP B6 Connect
1.
2.
3.
Avoid eating, bathing, smoking or caffeine (approx. 30 min).
Evite comer, bañarse, fumar o cafeína (aproximadamente 30 minutos).
Évitez de manger, de vous baigner, de fumer ou do consommer des produits contenant de
la caféine pendant environ 30 minutes.
Evitare di mangiare, fare il bagno, fumare o bere caffè (almeno 30 min.)
Vermeiden Sie essen, baden, rauchen oder Koffein (ca. 30 min).
Yeme, içme, duş alma, sigarak içme ve kefeinden uzak durunuz (yaklaşık 30 dak.)
Evite comer, tomar banho, fumar ou ingerir cafeína (cerca de 30 min).
Vermijd eten, baden, roken of het nuttigen van caffeine (ca. 30 minuten).
Αποφύγετε τη κατανάλωση φαγητού, το μπάνιο, το κάπνισμα ή την καφεΐνη
(περίπου 30 λεπτά)

30


Avoid activity and relax for 5-10 min.
Evite la actividad y relájese durante 5-10 min.
Évitez toute activité et détendez-vous pendant 5 à10 min.
Evitare di fare attività fisica e rilassarsi per 5-10 minuti.
Vermeiden Sie Bewegung und entspannen Sie sich für 5-10 Min.
Spordan kaçınınız ve 5-10 dakika dinlenmiş olunuz.
Evite a atividade física e relaxe 5-10 min.
Vermijd beweging en ontspan voor 5-10 minuten.
Αποφύγετε τη σωματική δραστηριότητα και χαλαρώστε για 5-10 λεπτά

5-10


Measure before medication intake.
Mida antes de tomar medicamentos.
Ne pas prendre de médicament avant de mesurer votre tension.
Effettuare la misurazione prima di assumere farmaci.
Messen Sie bevor Sie Medikamente einnehmen.
İlaç alımından önce ölçüm yapınız.
Proceda à medição antes de tomar medicação.
Meet alvorens u medicatie inneemt.
Πραγματοποιήστε τη μέτρηση πριν από τη λήψη φαρμάκων


Name of Purchaser / Nombre del comprador/
Nom de l'acheteur / Nome del rivenditore / Name
des Käufers / Alıcının adı / Nome do comprador /
Naam koper / Ονοματεπώνυμο αγοραστή /
/
Serial Number / Número de serie/ Numéro
de série / Numero di serie / Serien-Nr. / Seri
numarası / Número de série / Serienummer /
Αριθμός σειράς / /
Date of Purchase / Fecha de compra/ Date
d'achat / Data d’acquisto / Kaufdatum / Satın
alma tarihi / Data da compra / Datum van
aankoop / Ημερομηνία αγοράς / /
Specialist Dealer / Distribuidor especializado/
Revendeur / Categoria rivenditore / Fachhändler /
Uzman satıcı / Revendedor autorizado / Specialist
Dealer / Εξειδικευμένος αντιπρόσωποςa /
/
BP W100 ١٢ AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
FA
BP W100 ١٢ AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100 ١٢ AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100 ١٢ AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا



1Microlife BP B6 Connect EN
Display
Microlife BP B6 Connect EN
1ON/OFF button
2Display
3M-button (memory)
4Bluetooth/Time Button
5User Button
6Cuff socket
7MAM Switch
8Traffic light indicator
9USB Port
AT Mains Adapter Socket
AK Battery compartment
AL Cuff
AM Cuff tube
AN Cuff connector
AO Active Bluetooth®
AP Systolic value
AQ Diastolic value
AR Pulse rate
AS Battery display
BT Cuff fit check
-A: Suboptimal cuff fit
-B: Arm movement indicator «Err 2»
-C: Cuff pressure check «Err 3»
BK Cuff signal indicator «Err 1»
BL Irregular heartbeat (IHB) symbol
BM Atrial Fibrillation Indicator (AFIB)
BN User indicator
BO MAM Mode
BP Stored value
BQ Clinical Blood Pressure Average «MyBP»
BR Date/Time
BS Pulse indicator
CT Average Indicator «MyCheck»
Read the important information in these
instructions for use before using this
device. Follow the instructions for use for
your safety and keep it for future reference.
Type BF applied part
Keep dry
Manufacturer
Batteries and electronic devices must be
disposed of in accordance with the locally
applicable regulations, not with domestic
waste.
Authorized representative
in the European Community
Catalogue number
Serial number
(YYYY-MM-DD-SSSSS;
year-month-day-serial number)
Caution
Humidity limitation
Temperature limitation
Medical device
Keep away from children of age 0 - 3
CE Marking of Conformity
S
N
2
Intended use:
This oscillometric blood pressure monitor is intended for
measuring non-invasive blood pressure in people aged
12 years or older.
It is clinically validated in patients with hypertension, hypotension,
diabetes, pregnancy, pre-eclampsia, atherosclerosis, end-stage
renal disease, obesity and the elderly.
The device can detect an irregular pulse suggestive of Atrial Fibril-
lation (AF). Please note that the device is not intended to diagnose
AF. A diagnosis of AF can only be confirmed by ECG. The patient
is advised to see a physician.
Dear Customer,
This device was developed in collaboration with physicians and
clinical tests carried out prove its measurement accuracy to be of
a very high standard.*
Microlife AFIBsens is the world’s leading digital blood pressure
measurement technology for the detection of atrial fibrillation (AF)
and arterial hypertension. These are the two top risk factors of
getting a stroke or heart disease. It is important to detect AF and
hypertension at an early stage, even though you may not experi-
ence any symptoms. AF screening in general and thus also with
the Microlife AFIB algorithm, is recommended for people of 65
years and older. The AFIB algorithm indicates that atrial fibrillation
may be present. For this reason, it is recommended that you visit
your doctor when the device gives an AFIB signal during your
blood pressure measurement. The AFIB algorithm of Microlife has
been clinically investigated by several prominent clinical investiga-
tors and showed that the device detects patients with AFIB at a
certainty of 97-100%. 1,2
If you have any questions, problems or want to order spare parts
please contact your local Microlife-Customer Service. Your dealer
or pharmacy will be able to give you the address of the Microlife
dealer in your country. Alternatively, visit the internet at
www.microlife.com where you will find a wealth of invaluable infor-
mation on our products.
Stay healthy – Microlife AG!
* This device uses the same measuring technology as the award
winning «BP 3BTO-A» model tested according to the British and
Irish Hypertension Society (BIHS) protocol.
1 Kearley K, Selwood M, Van den Bruel A, Thompson M, Mant D,
Hobbs FR et al.: Triage tests for identifying atrial fibrillation in
primary care: a diagnostic accuracy study comparing single-lead
ECG and modified BP monitors. BMJ Open 2014; 4:e004565.
2 Wiesel J, Arbesfeld B, Schechter D: Comparison of the Microlife
blood pressure monitor with the Omron blood pressure monitor for
detecting atrial fibrillation. Am J Cardiol 2014; 114:1046-1048.
Table of contents
1. Appearance of the Atrial Fibrillation Indicator for early
Detection (Active only in MAM mode)
What is Atrial Fibrillation (AF)?
Who should be screened for Atrial Fibrillation?
Risk factors you can control
2. Using the device for the first time
Inserting the batteries
Setting the date and time
Selecting the correct cuff
Selecting the user
Selecting standard or MAM mode
3. Checklist for taking a reliable measurement
4. Taking a blood pressure measurement
Manual inflation
How not to store a reading
How do I evaluate my blood pressure
Average Indicator «MyCheck»
Appearance of the irregular heartbeat (IHB) symbol
5. Data memory
Viewing the average of the last 28 days
Viewing the clinical blood pressure average «MyBP»
Viewing the stored single values
Clearing all values
6. Battery indicator and battery change
Low battery
Flat battery - replacement
Which batteries and which procedure?
Using rechargeable batteries
7. Using a mains adapter
8. Bluetooth® Function
Bluetooth® operations
Bluetooth® pairing & app setup
Bluetooth® status
9. PC-Link functions
10. Error Messages
11. Safety, care, accuracy test and disposal
Device care
Cleaning the cuff
3Microlife BP B6 Connect EN
Accuracy test
Disposal
12. Guarantee
13. Technical Specifications
1. Appearance of the Atrial Fibrillation Indicator for
early Detection (Active only in MAM mode)
This device is able to detect atrial fibrillation (AF). This symbol BM
indicates that atrial fibrillation was detected during the measure-
ment. Please refer to the next paragraph for information regarding
the consultation with your doctor.
What is Atrial Fibrillation (AF)?
Normally, your heart contracts and relaxes to a regular beat.
Certain cells in your heart produce electrical signals that cause the
heart to contract and pump blood. Atrial fibrillation occurs when
rapid, disorganized electrical signals are present in the heart’s two
upper chambers, called the atria; causing them to contract irregu-
larly (this is called fibrillation). Atrial fibrillation is the most common
form of heart arrhythmia. It often causes no symptoms, yet it
significantly increases your risk of stroke. You’ll need a doctor to
help you control the problem.
Who should be screened for Atrial Fibrillation?
AF screening is recommended for people over 65 years of age,
since the chance of having a stroke increases with age. AF
screening is also recommended for people from the age of 50
years who have high blood pressure (e.g. SYS higher than 159 or
DIA higher than 99) as well as those with diabetes, coronary heart
failure or for those who have previously had a stroke.
In young people or in pregnancy AF screening is not recom-
mended as it could generate false results and unnecessary
anxiety. In addition, young individuals with AF have a low risk of
getting stroke as compared to elder people.
Risk factors you can control
Early diagnosis of AF followed by adequate treatment can signifi-
cantly reduce the risk of getting stroke. Knowing your blood pres-
sure and knowing whether you have AF is the first step in proactive
stroke prevention.
For more information visit our website: www.microlife.com/afib.
2. Using the device for the first time
Inserting the batteries
After you have unpacked your device, first insert the batteries. The
battery compartment AK is on the bottom of the device. Insert the
batteries (4 x 1.5 V, size AA), thereby observing the indicated
polarity.
Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button 3. To
confirm and then set the month, press the Bluetooth/Time
button 4.
2. Press the M-button to set the month. Press the Bluetooth/Time
button to confirm and then set the day.
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the Bluetooth/Time
button, the date and time are set and the time is displayed.
Information for the doctor on frequent appearance
of the atrial fibrillation indicator
This device is an oscillometric blood pressure monitor that also
analyses pulse irregularity during measurement. The device is
clinically tested.
The AFIB symbol is displayed after the measurement, if atrial
fibrillation occurred during measuring. If the AFIB symbol
appears after having performed a full blood pressure measure-
ment episode (triplicate measurements), the patient is advised
to perform another measurement episode (triplicate measure-
ments). If the AFIB symbol appears again, we recommend the
patient to seek medical advice.
If the AFIB-symbol appears on the screen of the blood pressure
monitor, it indicates the possible presence of atrial fibrillation.
The atrial fibrillation diagnosis however, must be made by a
cardiologist based on ECG interpretation.
Keep the arm still during measuring to avoid false readings.
This device may not or wrongly detect atrial fibrillation in
people with pacemakers or defibrillators.
In the presence of atrial fibrillation the diastolic blood pres-
sure value may not be accurate.
In the presence of atrial fibrillation using MAM-mode is
recommended for more reliable blood pressure measure-
ment.
4
5. If you want to change the date and time, press and hold the
Bluetooth/Time button for approx. 7-8 seconds until the year
number starts to flash. Now you can enter the new values as
described above.
Selecting the correct cuff
Microlife offers different cuff sizes. Select the cuff size to match the
circumference of your upper arms (measured by close fitting in the
centre of the upper arm).
Contact your local Microlife Service if the enclosed cuff AL
does not fit.
Connect the cuff to the device by inserting the cuff connector AN
into the cuff socket 6 as far as it will go.
Selecting the user
This device allows to store the results for 2 individual users.
Select the intended user (user 1 or user 2 BN) by pressing the
user button 5.
Selecting standard or MAM mode
Before each measurement, select standard (single measurement)
or MAM mode (automatic triple measurement). In MAM mode,
3 measurements are automatically taken in succession and the
result is then automatically analysed and displayed. Because the
blood pressure constantly fluctuates, a result obtained in this way
is more reliable than when a single measurement is performed.
To select MAM mode, slide the MAM switch 7 upwards to
position «3» until the MAM-symbol BO appears on the display.
To change to standard mode (single measurement), slide the
MAM switch downwards to position «1».
The bottom, right hand section of the display shows a 1, 2 or 3
to indicate which of the 3 measurements is currently being
taken.
There is a break of 15 seconds between the measurements.
A count down indicates the remaining time.
The individual results are not displayed. Your blood pressure
will only be displayed after all 3 measurements are taken.
Do not remove the cuff between measurements.
If one of the individual measurements was questionable, a
fourth one is automatically taken.
3. Checklist for taking a reliable measurement
Avoid activity, eating or smoking immediately before the
measurement.
Sit down on a back-supported chair and relax for 5 minutes.
Keep your feet flat on the floor and do not cross your legs.
Always measure on the same arm (normally left). It is recom-
mended that doctors perform double arm measurements on a
patients first visit in order to determine which arm to measure in
the future. The arm with the higher blood pressure should be
measured.
Remove close-fitting garments from the upper arm. To avoid
constriction, shirt sleeves should not be rolled up - they do not
interfere with the cuff if they are laid flat.
Always ensure that the correct cuff size is used (marking on the
cuff).
Fit the cuff closely, but not too tight.
Make sure that the cuff is positioned 1-2 cm above the
elbow.
The artery mark on the cuff (ca.3 cm long bar) must lie over
the artery which runs down the inner side of the arm.
Support your arm so it is relaxed.
Ensure that the cuff is at the same height as your heart.
4. Taking a blood pressure measurement
Select standard (single measurement) or MAM mode (auto-
matic triple measurement): see details in chapter 2.»
Cuff size for circumference of upper arm
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
Only use Microlife cuffs.
If you buy a spare Microlife cuff, please remove the cuff
connector AN from the cuff tube AM from the cuff supplied
with the original device and insert this cuff connector into
the tube of the spare cuff (valid for all cuff sizes).
Before each measurement, ensure that the correct user
is selected.
AF detection is only activated in MAM mode.
5Microlife BP B6 Connect EN
Press the ON/OFF button 1 to start the measurement.
The cuff will now pump up automatically. Relax, do not move
and do not tense your arm muscles until the measurement
result is displayed. Breathe normally and do not talk.
The cuff fit check BT on the display indicates that the cuff is
perfectly placed. If the icon BT-A appears, the cuff is fitted
suboptimally, but it is still ok to measure.
When the correct pressure is reached, the pumping stops and
the pressure falls gradually. If the required pressure was not
reached, the device will automatically pump some more air into
the cuff.
During the measurement, the pulse indicator BS flashes in the
display.
The result, comprising the systolic AP and the diastolic AQ blood
pressure and the pulse rate AR are displayed. Note also the
explanations on further display symbols in this booklet.
When the device has finished measuring, remove the cuff.
Switch off the device. (The monitor does switch off automati-
cally after approx. 1 min.).
Manual inflation
In case of high systolic blood pressure (e.g. above 135
mmHg), it can be an advantage to set the pressure individually.
Press the ON/OFF button after the monitor has been pumped up
to a level of approx. 30 mmHg (shown on the display). Keep the
button pressed until the pressure is about 40 mmHg above the
expected systolic value – then release the button.
How not to store a reading
As soon as the reading is displayed press and hold the ON/OFF
button 1 until «M» BP is flashing. Confirm to delete the reading by
pressing the Bluetooth/Time button 4.
How do I evaluate my blood pressure
The LED traffic light indicator on the left-hand side of the display
8 indicates within which range the measured blood pressure lies.
The value is either within the optimum (green), elevated (yellow) or
high (red) range. The classification corresponds to the following
ranges defined by international guidelines (ESH, ESC, JSH). Data
in mmHg.
The higher value is the one that determines the evaluation.
Example: a blood pressure value of 140/80 mmHg or a value of
130/90 mmHg indicates «blood pressure too high».
Average Indicator «MyCheck»
This symbol CT indicates after each measurement, if the most
recent measured value lies below, above or on the same level as
your stored average value (see also chapter «5. Data memory»).
AF detection is only activated in MAM mode.
You can stop the measurement at any time by pressing the
ON/OFF button or open the cuff (e.g. if you feel uneasy or
an unpleasant pressure sensation).
This monitor is specially tested for use in pregnancy and
pre-eclampsia. When you detect unusual high readings in
pregnancy, you should measure after a short while again
(eg. 1 hour). If the reading is still too high, consult your
doctor or gynecologist.
In pregnancy the AFIB symbol can be ignored.
«CL» is displayed when the reading is deleted from the
memory successfully.
Range Systolic Diastolic Recommendation
1. blood pressure
too high
≥135 ≥85 Seek medical
advice
2. blood pressure
elevated
130 - 134 80 - 84 Self-check
3. blood pressure
normal
<130 <80 Self-check
If the measured Systole or Diastole is more than 5mmHg
higher than the stored average, the arrow shows upwards.
If the measured Systole or Diastole is more than 5mmHg
lower than the stored average, the arrow shows down-
wards.
If the measured Systole and Diastole do not differ by more
than 5mmHg from the stored average, the arrow shows
straight on.
6
Appearance of the irregular heartbeat (IHB) symbol
This symbol BL indicates that an irregular heartbeat was detected.
In this case, the measured blood pressure may deviate from your
actual blood pressure values. It is recommended to repeat the
measurement.
5. Data memory
This device automatically stores up to 99 measurement values for
each of the 2 users.
Select either user 1 or 2 by pressing the user button 5.
Viewing the average of the last 28 days
Press the M-button 3 again. The display first shows «M» BP and
«28A», which stands for the average measurement values of the
last 28 days.
Viewing the clinical blood pressure average «MyBP»
Pressing the M-button 3 briefly when the device is switched off,
allows you to see the average clinically relevant blood pressure
«MyBP». The display first shows «M» BP and «MyBP» BQ. This
average is only shown when 12 clinically relevant measurement
values in the last 28 days have been performed.
Viewing the stored single values
Pressing the M-button again, allows you to see the last performed
measurement. The display first shows «M» BP and a value, e.g.
«M17». This means that there are 17 single values in the memory.
Pressing the M-button again displays the previous value. Pressing
the M-button repeatedly enables you to move from one stored
value to another.
Clearing all values
Make sure the correct user is activated.
If you are sure that you want to permanently remove all stored
values, hold down the M-button (the device must have been
switched off beforehand) until «CL ALL» appears and then
release the button. To permanently clear the memory, press the
Blutetooth/Time button while «CL ALL» is flashing. Individual
values cannot be cleared.
6. Battery indicator and battery change
Low battery
When the batteries are approximately ¾ empty the battery symbol
AS will flash as soon as the device is switched on (partly filled
battery displayed). Although the device will continue to measure
reliably, you should obtain replacement batteries.
If the measured systole and diastole differ in different direc-
tions from the stored average, this is indicated first with the
systole figure flashing, together with the up or down arrow
for two seconds. Thereafter, the diastole figure flashes with
the arrow pointing up or down for two seconds.
Information for the doctor in case of repeated appearance of
the IHB symbol:
This device is an oscillometric blood pressure monitor that also
measures the pulse during blood pressure measurement and
indicates when the heart rate is irregular.
Blood pressure readings with suboptimal cuff fit BT-A are
not considered in the average value.
Only measurements that were performed in the morning
between 05:00-10:59 or in the evening between 17:00-
22:59 are considered.
A maximum of 4 readings per day are considered (2 from
the morning and 2 from the evening).
Measurements performed in standard mode and in MAM-
mode are considered in the average, when they have been
performed during the right time of the day.
Measurements performed in MAM-mode or single standard
mode are both classed as single measurements for working
out the «MyBP average».
Blood pressure readings with suboptimal cuff fit BT-A are
not considered in the average value.
Pay attention that the maximum memory capacity of
99 memories is not exceeded. When the 99 memory is
full, the oldest value is automatically overwritten with
the 100 value. Values should be evaluated by a doctor
before the memory capacity is reached – otherwise data
will be lost.
Cancel deletion: press ON/OFF button 1 while «CL
ALL» is flashing.
7Microlife BP B6 Connect EN
Flat battery - replacement
When the batteries are flat, the battery symbol AS will flash as soon
as the device is switched on (flat battery displayed). You cannot
take any further measurements and must replace the batteries.
1. Open the battery compartment AK at the back of the device.
2. Replace the batteries ensure correct polarity as shown by the
symbols in the compartment.
3. To set date and time, follow the procedure described in Section
«2. Using the device for the first time».
Which batteries and which procedure?
Using rechargeable batteries
You can also operate this device using rechargeable batteries.
7. Using a mains adapter
You can operate this device using the Microlife mains adapter (DC
6V, 600 mA).
1. Plug the adapter cable into the mains adapter socket AT in the
blood pressure monitor.
2. Plug the adapter plug into the wall socket.
When the mains adapter is connected, no battery current is
consumed.
8. Bluetooth® Function
Use the Bluetooth® function to transfer data to «Microlife
Connected Health+» App on a smartphone (Android OS or iOS).
Information available on: www.microlife.com/technologies/
connect
Bluetooth® operations
Manually turn on Bluetooth®: Press Bluetooth/Time button 4
to activate Bluetooth®, Bluetooth® symbol AO on display will
blink.
Automatically turn on Bluetooth®: Bluetooth® will activate auto-
matically after a measurement. Bluetooth® symbol AO on
display will blink.
Manually turn off Bluetooth®: Press ON/OFF button 1 to turn
off Bluetooth®.
Automatically turn off Bluetooth®: Bluetooth® will turn off auto-
matically after 2 minutes if a smartphone does not connect to
the device.
Bluetooth® pairing & app setup
1. Open «Microlife Connected Health+» App on the smartphone
(Make sure the app is running in the foreground, not in the back-
ground.)
2. Turn on Bluetooth® manually to connect device to smartphone.
3. When smartphone finds the device, the smartphone will show a
message to pair with the device. Confirm on smartphone to
complete pairing. Cancel to abort pairing.
4. After pairing, the app will show a message to setup the device
user selection (1 or 2) to the app user profile. Confirm to
proceed with setup. Cancel to abort setup (if user selection is
incorrect).
5. After setup, the device will automatically exchange measure-
ment data and date/time settings with the app. Bluetooth® turns
off automatically after data exchange.
The memory retains all values although date and time must
be reset – the year number therefore flashes automatically
after the batteries are replaced.
Use 4 new, long-life 1.5 V, size AA alkaline batteries.
Do not use batteries beyond their date of expiry.
Remove batteries if the device is not going to be used for a
prolonged period.
Only use «NiMH» type reusable batteries.
Batteries must be removed and recharged when the flat
battery symbol appears. They should not remain inside the
device as they may become damaged (total discharge as a
result of low use of the device, even when switched off).
Always remove the rechargeable batteries if you do not
intend to use the device for a week or more.
Batteries cannot be charged in the blood pressure monitor.
Recharge batteries in an external charger and observe the
information regarding charging, care and durability.
Only use the Microlife mains adapter available as an orig-
inal accessory appropriate for your supply voltage.
Ensure that neither the mains adapter nor the cable are
damaged.
8
Bluetooth® status
Bluetooth® symbol AO blinking slowly: Bluetooth® is activated
and waiting for connection.
Bluetooth® symbol AO not blinking: Bluetooth® connection
established.
Bluetooth® symbol AO blinking rapidly: Bluetooth® connection
error.
9. PC-Link functions
This device can be used in conjunction with a personal computer
(PC) running the Microlife Blood Pressure Analyzer+ (BPA+) soft-
ware. The memory data can be transferred to the PC by
connecting the monitor via a cable.
If no download-voucher and cable is included download the BPA+
software from www.microlife.com/software and use a Micro-USB
cable.
10.Error Messages
If an error occurs during the measurement, the measurement is
interrupted and an error message, e.g. «Err 3», is displayed.
* Please immediately consult your doctor, if this or any other
problem occurs repeatedly.
11.Safety, care, accuracy test and disposal
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
In case of Bluetooth® connection error, turn off device Blue-
tooth®, wait for a minute, then re-try Bluetooth® connection.
Refer to chapter «10. Error Messages» for details.
Error Description Potential cause and remedy
«Err 1»
BK
Signal too
weak
The pulse signals on the cuff are too
weak. Re-position the cuff and repeat
the measurement.*
«Err 2»
BT-B
Error signal During the measurement, error signals
were detected by the cuff, caused for
instance by movement or muscle
tension. Repeat the measurement,
keeping your arm still.
«Err 3»
BT-C
Abnormal
cuff pressure
An adequate pressure cannot be
generated in the cuff. A leak may have
occurred. Check that the cuff is
correctly connected and is not too
loose. Replace the batteries if neces-
sary. Repeat the measurement.
«Err 5» Abnormal
result
The measuring signals are inaccurate
and no result can therefore be
displayed. Read through the checklist
for taking a reliable measurement and
then repeat the measurement.*
«Err 6» MAM Mode There were too many errors during the
measurement in MAM mode, making it
impossible to obtain a final result. Read
through the checklist for taking a reli-
able measurement and then repeat the
measurement.*
«HI» Pulse or cuff
pressure too
high
The pressure in the cuff is too high
(over 299 mmHg) OR the pulse is too
high (over 200 beats per minute).
Relax for 5 minutes and repeat the
measurement.*
«LO» Pulse too low The pulse is too low (less than 40 beats
per minute). Repeat the measure-
ment.*
Bluetooth®
symbol AO
blinks rapidly
Bluetooth® connection error. Turn off
the device Bluetooth® and close the
app on the smartphone. Wait for 1
minute, open the app on the smart-
phone and manually activate Blue-
tooth® on the device, to re-try Blue-
tooth® connection and data transfer.
«Err bt» Bluetooth®
self check
error
Bluetooth® is malfunctioning. Contact
your local Microlife distributor.
Safety and protection
Error Description Potential cause and remedy
9Microlife BP B6 Connect EN
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
The cuffs are sensitive and must be handled with care.
Only pump up the cuff once fitted.
Do not use this device if you think it is damaged or notice
anything unusual.
Never open this device.
Read the additional safety information provided within the indi-
vidual sections of this instruction manual.
The measurement results given by this device is not a diag-
nosis. It is not replacing the need for the consultation of a physi-
cian, especially if not matching the patient’s symptoms. Do not
rely on the measurement result only, always consider other
potentially occurring symptoms and the patient’s feedback.
Calling a doctor or an ambulance is advised if needed.
Do not use this device if the patient’s condition meets the following
contra-indications, to avoid inaccurate measurements or injuries.
The device is not intended for measuring blood pressure in
pediatric patients of age younger than 12 years old (children,
infant, or neonates).
Presence of significant cardiac arrhythmia during measurement
may interfere with blood pressure measurement and affect the
reliability of blood pressure readings. Consult with your doctor
about whether the device is suitable for use in this case.
The device measures blood pressure using a pressured cuff. If
the measuring limb suffers from injuries (for example open
wounds) or under conditions or treatments (for example intrave-
nous drip) making it unsuitable for surface contact or pressur-
ization, do not use the device, to avoid worsening of the injuries
or conditions.
Patient motions during measurement may interfere with the
measurement process and influence results.
Avoid taking measurements of patients with conditions,
diseases, and susceptible to environment conditions that lead
to incontrollable motions (e.g. trembling or shivering) and
inability to communicate clearly (for example children and
unconscious patients).
The device uses oscillometric method to determine blood pres-
sure. The arm being measure should have normal perfusion.
The device is not intended to be used on a limb with restricted
or impaired blood circulation. If you suffer with perfusion or
blood disorders, consult your doctor before using the device.
Avoid taking measurement on the arm on the side of a mastec-
tomy or lymph node clearance.
Do not use this device in a moving vehicle (for example in a car
or on an aircraft).
Indicates a potentially hazardous situation, which if not avoided,
could result in death or serious injury.
This device may only be used for the intended uses described
in this Instructions for Use. The manufacturer cannot be held
liable for damage caused by incorrect application.
Do not change the patient medication and treatment based the
result of one or multiple measurements. Treatment and medica-
tion changes should be prescribed only by a medical profes-
sional.
Inspect the device, cuff, and other parts for damage. DO NOT
USE the device, cuff or parts if they appear damaged or oper-
ating abnormally.
Blood flow of the arm is temporarily interrupted during measure-
ment. Extended interruption of blood flow reduces peripheral
circulation and may cause tissue injury. Beware of signs (for
example tissue discoloration) of impeded peripheral circulation
if taking measurements continuously or for an extended period
of time.
Prolonged exposure to cuff pressure will reduce peripheral
perfusion and may lead to injury. Avoid situations of extended
cuff pressurization beyond normal measurements. In the case
of abnormally long pressurization, abort the measurement or
loose the cuff to depressurize the cuff.
Ensure that children do not use this device unsupervised;
some parts are small enough to be swallowed. Be aware of
the risk of strangulation in case this device is supplied with
cables or tubes.
Contra-indications
WARNING
10
Do not use this device in oxygen rich environment or near
flammable gas.
The device is not water resistant or water proof. Do not spill or
immerse the device in water or other liquids.
Do not dissemble or attempt to service the device, accessory
and parts, during use or in storage. Access to the device
internal hardware and software is prohibited. Unauthorized
access and servicing of the device, during use or in storage,
may compromise the safety and performance of the device.
Keep the device away from children and people incapable of
operating the device. Beware of the risks of accidental ingestion
of small parts and of strangulation with the cables and tubes of
this device and accessories.
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient, or
cause damage to the device or other property.
The device is intended only for measuring blood pressure at
upper arm. Do not measure other sites because the reading
does not reflect your blood pressure accurately.
After a measurement is completed, loosen the cuff and rest for
> 5 minutes to restore limb perfusion, before taking another
measurement.
Do not use this device with other medical electrical (ME) equip-
ment simultaneously. This may cause device malfunction or
measurement inaccuracies.
Do not use this device in proximity of high frequency (HF)
surgical equipment, magnetic resonance imaging (MRI) equip-
ment, and computerized tomography (CT) scanners. This may
cause device malfunction and measurement inaccuracies.
Use and store the device, cuff and parts in temperature and
humidity conditions specified in the «Technical Specifications».
Usage and storage of the device, cuff and parts in conditions
outside ranges given in the «Technical Specifications» may
results in device malfunction and the safety of usage.
Protect the device and accessories from the following to avoid
damaging the device:
water, other liquids, and moisture
extreme temperatures
impacts and vibrations
direct sunlight
contamination and dust
This device has 2 user settings. Please ensure it is cleaned and
disinfected between users to prevent any cross contamination.
Stop using this device and cuff and consult with your doctor if
you experience skin irritation or discomfort.
Electromagnetic Compatibility Information
This device is compliant with EN60601-1-2: 2015 Electromagnetic
Disturbances standard.
This device is not certified to be used in vicinity of High Frequency
(HF) medical equipment.
Do not use this device close to strong electromagnetic fields and
portable radio frequency communication devices (for example
microwave oven and mobile devices). Keep a minimum distance
of 0.3 m from such devices when using this device.
Device care
Clean the device only with a soft, dry cloth.
Cleaning the cuff
Carefully remove spots on the cuff with a damp cloth and
soapsuds.
Accuracy test
We recommend this device is tested for accuracy every 2 years or
after mechanical impact (e.g. being dropped). Please contact your
local Microlife-Service to arrange the test (see foreword).
Disposal
12.Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. During this guarantee period, at our discretion,
Microlife will repair or replace the defective product free of charge.
Opening or altering the device invalidates the guarantee.
The following items are excluded from the guarantee:
Transport costs and risks of transport.
Damage caused by incorrect application or non-compliance
with the instructions for use.
Damage caused by leaking batteries.
Damage caused by accident or misuse.
CAUTION
WARNING: Under no circumstances may you wash the
inner bladder!
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
11Microlife BP B6 Connect EN
Packaging/storage material and instructions for use.
Regular checks and maintenance (calibration).
Accessories and wearing parts: Batteries, power adapter
(optional).
The cuff is covered by a functional guarantee (bladder tightness)
for 2 years.
Should guarantee service be required, please contact the dealer
from where the product was purchased, or your local Microlife
service. You may contact your local Microlife service through our
website: www.microlife.com/support
Compensation is limited to the value of the product. The guarantee
will be granted if the complete product is returned with the original
invoice. Repair or replacement within guarantee does not prolong
or renew the guarantee period. The legal claims and rights of
consumers are not limited by this guarantee.
13.Technical Specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
The Bluetooth® word mark and logos are registered trademarks
owned by Bluetooth SIG, Inc. and any use of such marks by Micro-
life Corp. is under license. Other trademarks and trade names are
those of their respective owners.
Operating
conditions:
10 - 40 °C / 50 - 104 °F
15 - 90 % relative maximum humidity
Storage conditions: -20 - +55 °C / -4 - +131 °F
15 - 90 % relative maximum humidity
Weight: 415 g (including batteries)
Dimensions: 157.5 x 105 x 61.5 mm
Measuring
procedure:
oscillometric, corresponding to
Korotkoff method: Phase I systolic,
Phase V diastolic
Measurement range: SYS: 60 - 255 mmHg, DIA:
40 - 200mmHG
Pulse: 40 - 199 beats per minute
Cuff pressure display
range:
0 - 299 mmHg
Resolution: 1 mmHg
Static accuracy: within ± 3 mmHg
Pulse accuracy: ± 5 % of the readout value
Wireless
Communication: Bluetooth® Low Energy
Compatibility: iOS: iOS 13.0 or newer
Android: Android 8 or newer
Voltage source: 4 x 1.5 V alkaline batteries; size AA
Mains adapter DC 6V, 600 mA
(optional)
Battery lifetime: approx. 920 measurements
(using new batteries)
IP Class: IP 20
Reference to
standards:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life: Device: 5 years or 10000 measurements,
whichever comes first
Accessories: 2 years or 5000 measure-
ments, whichever comes first
Pantalla
Microlife BP B6 Connect ES
1Botón ON/OFF (Encendido/Apagado)
2Pantalla
3Botón M (Memoria)
4Bluetooth/Botón Hora
5Botón de usuario
6Enchufe para manguito
7Interruptor MAM
8Indicador de semáforo
9Puerto USB
AT Enchufe para adaptador de corriente
AK Compartimento de baterías
AL Brazalete
AM Tubo de brazalete
AN Conector del manguito
AO Bluetooth® activo
AP Valor sistólico
AQ Valor diastólico
AR Frecuencia del pulso
AS Indicador de batería
BT Control de ajuste del brazalete
-A: Ajuste subóptimo del brazalete
-B: Indicador de movimiento del brazo «Err 2»
-C:Comprobación de la presión del brazalete «Err 3»
BK Indicador de señal del brazalete «Err 1»
BL Símbolo de latidos irregulares (IHB)
BM Indicador de la fibrilación auricular (AFIB)
BN Indicador de usuario
BO Modo MAM
BP Valor guardado
BQ Promedio Presión Arterial Clínica «MyBP»
BR Fecha/Hora
BS Indicador del pulso
CT Indicador de promedio «MyCheck»
Antes de utilizar el dispositivo lea estas
instrucciones de uso, ya que contienen
información importante. Siga las instruc-
ciones por su seguridad y consérvelas para
poder consultarlas en el futuro.
Pieza aplicada tipo BF
Mantener en lugar seco
Fabricante
Las baterías y los dispositivos electrónicos
se deben eliminar según indique la norma-
tiva local pertinente y no se deben
desechar junto con la basura doméstica.
Representante autorizado en la
Comunidad Europea
Número de referencia
Número de serie (AAAA-MM-DD-SSSSS;
año-mes-día-número de serie)
Precaución
Limitación de humedad
Limitación de temperatura
Dispositivo médico
Mantenga el dispositivo fuera del alcance
de los niños de 0 a 3 años de edad.
Marca de conformidad CE
S
NN
12
13Microlife BP B6 Connect ES
Uso previsto:
Este monitor de presión arterial oscilométrico está diseñado para
medir la presión arterial no invasiva en personas de 12 años o
más.
Está clínicamente validado en pacientes con hipertensión, hipo-
tensión, diabetes, embarazo, preeclampsia, aterosclerosis, enfer-
medad renal en etapa terminal, obesidad y adultos mayores.
El dispositivo puede detectar un pulso irregular sugestivo de fibri-
lación atrial (FA). Tenga en cuenta que el dispositivo no está dise-
ñado para diagnosticar FA. El diagnóstico de FA solo puede
confirmarse mediante ECG. Se le aconseja al paciente que vea a
un médico.
Estimado cliente,
Este dispositivo ha sido desarrollado en colaboración con médicos
y su muy alta precisión ha sido probada en ensayos clínicos.*
Microlife AFIBsens es la tecnología de medición digital de presión
arterial líder en el mundo para la detección de la fibrilación atrial
(FA) y la hipertensión arterial. Estos son los dos principales
factores de riesgo de sufrir un derrame cerebral o una enfermedad
cardíaca. Es importante detectar la FA y la hipertensión en una
etapa temprana, aunque es posible que no experimente ningún
síntoma. La detección de FA en general y por lo tanto, también con
el algoritmo Microlife AFIB, se recomienda para personas de 65
años en adelante. El algoritmo AFIB indica que la fibrilación atrial
puede estar presente. Por esta razón, se recomienda que visite a
su médico cuando el dispositivo emita una señal AFIB durante la
medición de la presión arterial. El algoritmo AFIB de Microlife ha
sido investigado clínicamente por varios investigadores clínicos
destacados y demostró que el dispositivo detecta pacientes con
AFIB con una certeza de 97-100%. 1,2
Si tiene cualquier pregunta o problema o si desea pedir piezas de
recambio, no dude en contactar con su servicio de atención al
cliente de Microlife local. Su distribuidor o farmacia podindicarle
la dirección del distribuidor de Microlife en su país. También puede
visitarnos en Internet en www.microlife.com donde encontrará
información útil sobre nuestros productos.
¡Cuide su salud con Microlife AG!
* Este dispositivo usa la misma tecnología de medición que el
premiado modelo «BP 3BTO-A» probado de acuerdo con el proto-
colo de la Sociedad Británica e Irlandesa de Hipertensión (BIHS).
1 Kearley K, Selwood M, Van den Bruel A, Thompson M, Mant D,
Hobbs FR et al.: Triage tests for identifying atrial fibrillation in
primary care: a diagnostic accuracy study comparing single-lead
ECG and modified BP monitors. BMJ Open 2014; 4:e004565.
2 Wiesel J, Arbesfeld B, Schechter D: Comparison of the Microlife
blood pressure monitor with the Omron blood pressure monitor for
detecting atrial fibrillation. Am J Cardiol 2014; 114:1046-1048.
Índice
1. Aspecto del indicador de fibrilación atrial para la
detección temprana (activo solo en modo MAM)
¿Qué es fibrilación auricular (FA)?
¿Quién debe ser examinado para fibrilación atrial?
Factores de riesgos que le permite controlar
2. Uso del dispositivo por primera vez
Colocar las baterías
Ajuste de fecha y hora
Elegir el manguito correcto
Seleccionar el usuario
Seleccionando el modo estándar o MAM
3. Lista de chequeo para efectuar una medición fiable
4. Medición de la presión arterial
Inflación manual
Procedimiento para no guardar la lectura
¿Cómo he de evaluar mi presión arterial?
Indicador medio «MyCheck»
Apariencia del símbolo de latidos irregulares (IHB)
5. Memoria de datos
Visualización del promedio de los últimos 28 días
Visualización del promedio clínico de presión arterial «MyBP»
Visualización de los valores individuales almacenados
Borrar todos los valores
6. Indicador de baterías y cambio de baterías
Baterías con poca carga
Baterías descargadas – cambio
¿Qué baterías y qué procedimiento?
Uso de baterías recargables
7. Uso de un adaptador de corriente
8. Función Bluetooth®
Operaciones con Bluetooth®
Configuración de la aplicación y emparejamiento
de Bluetooth®
Estado de Bluetooth®
9. Funciones de conexión con el PC
10. Mensajes de error
14
11. Seguridad, cuidado, control de precisión y eliminación
de residuos
Cuidado del dispositivo
Limpieza del brazalete
Control de precisión
Eliminación de residuos
12. Garantía
13. Especificaciones técnicas
1. Aspecto del indicador de fibrilación atrial para la
detección temprana (activo solo en modo MAM)
Este dispositivo puede detectar la fibrilación atrial (FA). Este
símbolo BM indica que se detectó fibrilación atrial durante la medi-
ción. Consulte el párrafo siguiente para obtener información sobre
la consulta con su médico.
¿Qué es fibrilación auricular (FA)?
Normalmente, el corazón se contrae y relaja con un ritmo regular.
Ciertas células del corazón producen señales eléctricas que
hacen que el órgano se contraiga y bombee la sangre. La fibrila-
ción auricular se produce cuando en las dos aurículas (las
cámaras superiores del corazón) se dan señales rápidas e irregu-
lares. Esto hace que las aurículas se contraigan de manera irre-
gular (fibrilación). La fibrilación auricular es la forma más común
de arritmia cardiaca. Si bien a menudo no se manifiesta mediante
síntomas, hace que el riesgo de infarto cerebral aumente signifi-
cativamente. Necesitará la ayuda de un médico para controlar
este problema.
¿Quién debe ser examinado para fibrilación atrial?
La detección de FA se recomienda para personas mayores de 65
años, ya que la posibilidad de tener un accidente cerebrovascular
aumenta con la edad. La detección de FA también se recomienda
para personas mayores de 50 años que tienen presión arterial alta
(por ejemplo, SYS superior a 159 o DIA superior a 99), así como
aquellos con diabetes, insuficiencia cardíaca coronaria o para
aquellos que han tenido un accidente cerebrovascular.
En personas jóvenes o en el embarazo no se recomienda el
examen de detección de FA, ya que podría generar resultados
falsos y ansiedad innecesaria. Además, las personas jóvenes con
fibrilación atrial tienen un riesgo bajo de sufrir un derrame cerebral
en comparación con las personas mayores.
Factores de riesgos que le permite controlar
El diagnóstico precoz de FA seguido de un tratamiento adecuado
puede reducir significativamente el riesgo de sufrir un accidente
cerebrovascular. Conocer su presión arterial y saber si tiene FA es
el primer paso en la prevención proactiva del accidente cerebro-
vascular.
Para más información, visite nuestra web: www.microlife.com/afib.
2. Uso del dispositivo por primera vez
Colocar las baterías
Después de desembalar el dispositivo, en primer lugar, inserte las
baterías. El compartimento de las baterías AK está en la parte infe-
Información para su médico en caso de indicación de
fibrilación auricular frecuente
Este dispositivo es un tensiómetro oscilométrico que también
analiza la frecuencia de las pulsaciones durante la medición. El
dispositivo ha sido probado clínicamente.
El símbolo AFIB se muestra después de la medición, si se
produjo fibrilación atrial durante la medición. Si aparece el
símbolo AFIB después de haber realizado un episodio completo
de medición de la presión sanguínea (mediciones por tripli-
cado), se recomienda al paciente realizar otro episodio de
medición (mediciones por triplicado). Si el símbolo AFIB
aparece nuevamente, recomendamos que el paciente busque
asistencia médica.
Si el símbolo AFIB aparece en la pantalla del monitor de presión
arterial, indica la posible presencia de fibrilación atrial. Sin
embargo, el diagnóstico de fibrilación atrial debe ser realizado
por un cardiólogo según la interpretación del ECG.
Mantenga el brazo quieto durante la medición para evitar
lecturas falsas.
Este dispositivo puede detectar o no detectar la fibrilación
atrial en personas con marcapasos o desfibriladores.
En presencia de fibrilación auricular, el valor de la presión
arterial diastólica puede no ser exacto.
En presencia de fibrilación auricular se recomienda usar el
modo MAM para una medición más confiable de la presión
arterial.
15Microlife BP B6 Connect ES
rior del dispositivo. Inserte las baterías (4 x 1,5 V, tamaño AA) de
acuerdo con las marcas de polaridad indicadas.
Ajuste de fecha y hora
1. Una vez activadas las baterías, el número del o parpadea en
la pantalla. Ajuste el año pulsando el botón M 3. Para confir-
marlo y ajustar a continuacn el mes, pulse el Bluetooth/botón
Hora 4.
2. Ahora puede ajustar el mes usando el botón M. Pulse el Blue-
tooth/botón Hora para confirmar y, a continuacn, ajuste el día.
3. Por favor, siga las instrucciones anteriores para ajustar el día,
la hora y los minutos.
4. Una vez que haya ajustado los minutos y pulsado el Blutooth/
botón Hora, la fecha y la hora quedan establecidas y se visua-
liza la hora.
5. Si desea cambiar la fecha y la hora, pulse y mantenga pulsado
el Bluetooth/botón Hora durante aprox. 7-8 segundos hasta
que comience a parpadear el número del año. Ahora, podrá
introducir los nuevos valores tal como se ha descrito anterior-
mente.
Elegir el manguito correcto
Microlife ofrece diferentes tamaños de manguitos. Elija el tamaño
de manguito adecuado según la circunferencia de su brazo
(medida de forma ajustada en el centro del brazo).
Contacte su servicio al cliente de Microlife local, si el manguito
AL incluido no es el adecuado para usted.
Conecte el manguito al dispositivo insertando el conector AN
del manguito en el enchufe 6 del manguito hasta que no entre
más.
Seleccionar el usuario
Este dispositivo permite almacenar los resultados de 2 usuarios.
Seleccione el usuario deseado (usuario 1 o usuario 2 BN)
presionando el botón de usuario 5.
Seleccionando el modo estándar o MAM
Antes de cada medición, seleccione estándar (medición única) o
modo MAM (triple medición automática). En modo MAM, 3 medi-
ciones se toman automáticamente en sucesión y la el resultado se
analiza automáticamente y se muestra. Debido a que la presión
arterial fluctúa constantemente, un resultado obtenido de esta
manera es más confiable que cuando se realiza una única medi-
ción.
Para seleccionar el modo MAM, deslice el interruptor MAM 7
hacia arriba hasta la posición «3» hasta que aparezca el
símbolo MAM BO en la pantalla. Para cambiar al modo estándar
(medición única), deslice el interruptor MAM hacia abajo hasta
la posición «1».
En la parte inferior izquierda de la pantalla aparecen 1, 2 o 3
para indicar cuál de las 3 mediciones se está realizando en ese
momento.
Hay un descanso de 15 segundos entre las mediciones. Una
cuenta regresiva indica el tiempo restante.
Los resultados individuales no se visualizan. Su presión arterial
sólo se visualizará una vez que se hayan efectuado las 3 medi-
ciones.
No retire el manguito entre las mediciones.
Si una de las mediciones individuales ha sido dudosa, se toma
automáticamente una cuarta.
Tamaño de manguito para una circunferencia del brazo
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm
Use únicamente manguitos Microlife.
Si compra un brazalete de repuesto Microlife, retire el
conector del brazalete AN del tubo del brazalete AM del
brazalete suministrado con el dispositivo original e inserte
este conector en el tubo del brazalete de repuesto (válido
para todos los tamaños de brazaletes).
Antes de cada medición, asegúrese de seleccionar el
usuario correcto.
La detección de AF solo se activa en modo MAM.
16
3. Lista de chequeo para efectuar una medición fiable
Evite comer o fumar, así como cualquier otra actividad inmedia-
tamente antes de la medición.
Siéntese en una silla con respaldo y relájese durante 5 minutos.
Mantenga los pies planos sobre el piso y no cruce las piernas.
Efectúe la medición siempre en el mismo brazo (normal-
mente en el izquierdo). Es recomendable que su médico realice
dos mediciones en cada brazo durante la primera visita para
determinar de qué brazo se tomarán las mediciones en el
futuro. Las mediciones se deben efectuar en el brazo con
presión arterial más alta.
Quítese las prendas de vestir ajustadas a su brazo. Para evitar
la constricción, no se deben arremangar las mangas de
camisa, ya que no interfieren con el manguito si se encuentran
en contacto con el brazo.
Asegúrese de utilizar el tamaño correcto del manguito
(marcado en el manguito).
Coloque el manguito de tal forma que esté ajustado, pero
que no quede demasiado apretado.
Asegúrese de que el manguito esté colocado 1-2 cm por
encima del codo.
La marca de la arteria en el manguito (barra larga de 3 cm)
debe descansar sobre la arteria que va en el lado interior del
brazo.
Coloque el brazo de tal forma que esté relajado.
Asegúrese de que el manguito se encuentre a la misma
altura que su corazón.
4. Medición de la presión arterial
Seleccione el modo estándar (medición única) o MAM (auto-
mático medición triple): ver detalles en el capítulo 2.».
Presione el botón ON/OFF 1 para iniciar la medición.
Ahora, el manguito se inflará automáticamente. Relájese, no se
mueva y no tense los músculos del brazo hasta que se visua-
lice el resultado de la medición. Respire normalmente y no
hable.
La comprobación de ajuste del brazalete AR en la pantalla
indica que el brazalete está perfectamente colocado. Si
aparece el icono BT-A, el brazalete se ajusta de forma subóp-
tima, pero todavía está bien para medir.
Una vez alcanzada la presión correcta, el inflado se detiene y
la presión disminuye gradualmente. Si no se alcanzó la presión
necesaria, el dispositivo bombeará automáticamente más aire
al manguito.
Durante la medición, el indicador de pulso BM parpadea en la
pantalla.
Se visualiza el resultado compuesto por la presión arterial sistó-
lica AP, diastólica AQ, y la frecuencia del pulso AR. Tenga en
cuenta también las explicaciones de otras indicaciones en este
manual.
Retire el manguito cuando la medición haya terminado.
Desconecte el dispositivo. (El tensiómetro se apaga automáti-
camente al cabo de aprox. 1 min).
Inflación manual
En caso de presión arterial sistólica alta (por ejemplo, más de
135 mmHg), puede ser una ventaja establecer la presión indivi-
dualmente. Presione el botón ON/OFF después de que el monitor
haya sido bombeado hasta un nivel de aprox. 30 mmHg (mostrado
en la pantalla). Mantenga presionado el botón hasta que la presión
sea aproximadamente 40 mmHg por encima del valor sistólico
esperado, luego suelte el botón.
Procedimiento para no guardar la lectura
Tan pronto como se muestre la lectura, mantenga presionado el
botón de ON/OFF 1 hasta que parpadee «M» BP. Confirme para
eliminar la lectura presionando el botón Bluetooth/Time 7.
¿Cómo he de evaluar mi presión arterial?
El indicador LED de semáforo en el lado izquierdo de la pantalla
8 indica dentro de qué rango se encuentra la presión arterial
medida. El valor está dentro del óptimo (verde), elevado (amarillo)
La detección de AF solo se activa en modo MAM.
Puede detener la medición en cualquier momento presion-
ando el botón ON/OFF o abriendo el manguito (por ejemplo
si nota una sensación de presión molesta o desagradable).
Este monitor está especialmente probado para su uso en el
embarazo y la preeclampsia. Cuando detecta altas lecturas
inusuales en el embarazo, debe medir después de un
tiempo breve (por ejemplo, 1 hora). Si la lectura es
demasiado alta, consulte a su médico o ginecólogo.
En el embarazo, se puede ignorar el símbolo AFIB.
«CL» se muestra cuando la lectura se elimina de la
memoria con éxito.
17Microlife BP B6 Connect ES
o rango alto (rojo) La clasificación corresponde a la siguiente
rangos definidos por las directrices internacionales (ESH, ESC,
JSH). Datos en mmHg.
El valor superior es el que determina la evaluación. Ejemplo: un
valor de la presión arterial de 140/80 mm Hg o 130/90 mm Hg
indica «presión arterial demasiado alta».
Indicador medio «MyCheck»
Este símbolo CT indica después de cada medición, si es el másel
valor medido reciente se encuentra debajo, arriba o en el mismo
nivel que su valor promedio almacenado (ver también el capítulo
«5. Memoria de datos»).
Apariencia del símbolo de latidos irregulares (IHB)
Este símbolo
AN
indica que se detectó un latido cardíaco irregular.
En este caso, la presión arterial medida puede diferir de sus valores
reales de presión arterial. Se recomienda repetir la medición.
5. Memoria de datos
Este dispositivo almacena automáticamente hasta 99 mediciones
por cada usuario.
Seleccione el usuario 1 o 2 presionando el botón de usuario 5.
Visualización del promedio de los últimos 28 días
Presione el botón M 3 nuevamente. La pantalla muestra primero
«M» BP y «28A», que representa los valores de medición
promedio de los últimos 28 días.
Visualización del promedio clínico de presión arterial
«MyBP»
Al presionar brevemente el botón M 3 cuando el dispositivo está
apagado, le permite ver la presión sanguínea media clínicamente
relevante «MyBP». La pantalla muestra primero «M» BP y
«MyBP» BQ. Este promedio solo se muestra cuando se han reali-
zado 12 valores de medición clínicamente relevantes en los
últimos 28 días.
Nivel Sistólico Diastólico Recomendación
1. presión arterial
demasiado alta
≥135 ≥85 Acudir al médico
2. presión arterial
elevada
130 - 134 80 - 84 Autocontrol
3. presión arterial
normal
<130 <80 Autocontrol
Si la sístole o diástole medida es superior a 5 mmHg
más alto que el promedio almacenado, la flecha muestra
hacia arriba.
Si la sístole o diástole medida es más de 5 mmHg más baja
que el promedio almacenado, la flecha muestra hacia
abajo.
Si la sístole y la diástole medidas no difieren en más de 5
mmHg del promedio almacenado, la flecha se muestra en
línea recta.
Si la sístole y la diástole medidas difieren en diferentes
direcciones del promedio almacenado, esto se indica
primero con la figura de la sístole parpadeando, junto con
la flecha hacia arriba o hacia abajo durante dos segundos.
A partir de entonces, la figura de diástole parpadea con la
flecha apuntando hacia arriba o hacia abajo durante dos
segundos.
Información para su doctor en caso de aparición repetida
del símbolo IHB
Este dispositivo es un monitor oscilométrico de presión arterial
que también mide el pulso durante la medición de la presión
arterial e indica cuándo el ritmo cardiaco es irregular.
Las lecturas de presión arterial con ajuste de manguito
subóptimo BT-A no se consideran en el valor promedio.
Solo se consideran las mediciones que se realizaron
en la mañana entre las 05:00-10:59 o en la tarde entre las
17:00-22:59.
Se consideran un máximo de 4 lecturas por día (2 deLa
mañana y 2 de la tarde).
Mediciones realizadas en modo estándar y en modo MAM
se consideran en el promedio, cuando se han realizado en
el momento adecuado del día.
Mediciones realizadas en modo MAM o estándar único.
El modo se clasifica como medidas individuales para
trabajarel «promedio de MyBP».
Las lecturas de presión arterial con ajuste de manguito
subóptimo BT-A no se consideran en el valor promedio.
18
Visualización de los valores individuales almacenados
Al presionar nuevamente el botón M, le permite ver la última medi-
ción realizada. La pantalla muestra primero «M» BP y un valor, p.
Ej. «M17». Esto significa que hay 17 valores únicos en la
memoria.
Al volver a pulsar el botón M se vuelve a visualizar el valor anterior.
Pulsando el botón M repetidamente se puede cambiar de un valor
guardado a otro.
Borrar todos los valores
Asegúrese que el usuario correcto está activado.
Si está seguro de que desea eliminar permanentemente todos los
valores almacenados, mantenga presionado el botón M (el dispo-
sitivo debe haberse apagado previamente) hasta que aparezca
«CL ALL» y luego suelte el botón. Para borrar la memoria de
forma permanente, presione el Bluetooth/botón de tiempo mien-
tras parpadea «CL ALL». Los valores individuales no se pueden
borrar.
6. Indicador de baterías y cambio de baterías
Baterías con poca carga
Cuando las baterías están gastadas aproximadamente ¾, el
símbolo de baterías AS parpadea al momento de encender el
dispositivo (se visualiza una batería parcialmente cargada).
Aunque el dispositivo seguirá midiendo de manera fiable, tenga a
mano baterías de recambio.
Baterías descargadas – cambio
Cuando las baterías están gastadas, el símbolo de baterías AS
parpadea al momento de encender el dispositivo (se visualiza una
batería descargada). Ya no se puede realizar ninguna medición y
es preciso cambiar las baterías.
1. Abra el compartimento de baterías AK situado en la parte
posterior del dispositivo.
2. Sustituya las baterías; asegúrese de que la polaridad sea la
correcta, tal como lo indican los signos en el compartimiento.
3. Para ajustar la fecha y la hora, siga el procedimiento descrito
en el Apartado «2. Uso del dispositivo por primera vez».
¿Qué baterías y qué procedimiento?
Uso de baterías recargables
Este dispositivo también se puede usar con baterías recargables.
7. Uso de un adaptador de corriente
Este dispositivo se puede hacer funcionar utilizando el adaptador
de corriente de Microlife (DC 6V, 600 mA).
Tenga cuidado de no exceder la capacidad máxima de la
memoria que es de 99 valores. Cuando la memoria está
llena, el valor más antiguo es reemplazado por el valor
número 100. Los valores deberán ser evaluados por un
médico antes de alcanzar la capacidad máxima de la
memoria; en caso contrario, se perderán los datos.
Cancelar eliminación: presione el botón ON/OFF 1
mientras «CL ALL» está parpadeando.
La memoria retiene todos los valores, aunque haya que
resetear la fecha y la hora; para este fin, el número del año
parpadea automáticamente después de cambiar las
baterías.
Utilice 4 baterías alcalinas nuevas de tamaño AA, de 1,5 V,
de larga duración.
No utilice baterías caducadas.
Si no va a usar el dispositivo durante un período prolon-
gado, extraiga las baterías.
Utilice únicamente baterías reutilizables del tipo «NiMH».
Las bateas se deben extraer y recargar, cuando aparezca
el símbolo de batería (batería descargada). No deben
permanecer en el interior del dispositivo, ya que se pueden
dañar (descarga total como resultado de un uso poco
frecuente del dispositivo, incluso estando apagado).
Retire siempre las baterías recargables si no va a usar el
dispositivo en una semana o más.
¡Las baterías NO se pueden recargar dentro del
tensiómetro! Recargue las baterías en un cargador externo
y observe la información relativa a la recarga, el cuidado y
a la duración.
Utilice únicamente el adaptador de corriente de Microlife
disponible como accesorio original, apropiado para su
voltaje de alimentación.
Asegúrese de que no estén dañados ni el adaptador
ni el cable.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131

Microlife BPB6 Manuel utilisateur

Catégorie
Unités de pression artérielle
Taper
Manuel utilisateur