Johnson Controls TE-63xS Series Guide d'installation

Taper
Guide d'installation
TE-63xS Series Strap-Mount Temperature Sensors Installation Instructions 1
Refer to the QuickLIT website for the most up-to-date version of this document.
Applications
Installation
Dimensions
Mounting
Location Considerations
Consider the following mounting location guidelines:
Avoid areas subject to excessive vibration,
electrical noise, direct sunlight, or the effects of
radiant heat.
Keep electrical wiring as short as possible to
minimize temperature error.
Mounting the Sensor
See Figure 2 and mount the temperature sensor as
follows:
1. Mount the probe to the pipe using cable ties (three
included) or adjustable pipe clamps. Use thermal
conductive compound, F-1000-182 (order
separately), or equivalent, between the sensor and
pipe for best performance.
Note: Use Accessory Kit TE-6300-615 for pipe sizes
larger than 2 in. (51 mm) and up to 10 in. (250 mm)
and -40 to 220°F (-40 to 104°C) temperature range.
2. Wire the sensor to the controller.
IMPORTANT: The TE-63xS Series Strap-Mount
Temperature Sensors is intended to provide an input
to equipment under normal operating conditions.
Where failure or malfunction of the sensor could
lead to personal injury or property damage to the
controlled equipment or other property, additional
precautions must be designed into the control
system. Incorporate and maintain other devices,
such as supervisory or alarm systems or safety or
limit controls, intended to warn of or protect against
failure or malfunction of the sensor.
IMPORTANT : Le TE-63xS Series Strap-Mount
Temperature Sensor est destiné à transmettre des
données entrantes à un équipement dans des
conditions normales de fonctionnement. Lorsqu'une
défaillance ou un dysfonctionnement du sensor
risque de provoquer des blessures ou
d'endommager l'équipement contrôlé ou un autre
équipement, la conception du système de contrôle
doit intégrer des dispositifs de protection
supplémentaires. Veiller dans ce cas à intégrer de
façon permanente d'autres dispositifs, tels que des
systèmes de supervision ou d'alarme, ou des
dispositifs de sécurité ou de limitation, ayant une
fonction d'avertissement ou de protection en cas de
défaillance ou de dysfonctionnement du sensor.
IMPORTANT: Do not install the TE-63xS Series
Strap-Mount Temperature Sensor probe in ambient
temperatures beyond the specified -50 to 220F
(-46 to 104C) temperature range. Installing the
temperature sensor in ambient temperatures
beyond this range may damage the unit and void the
warranty.
Figure 1: Sensor Dimensions, in. (mm)
F
I
G
:
s
n
s
_
d
i
m
3.0 (76)
IMPORTANT: If using adjustable metal pipe
clamps, do not overtighten the clamps.
Overtightening the clamps may damage the sensor
or cable.
Figure 2: Installing the Strap-Mount Sensor
F
I
G
:
s
n
s
_
i
n
s
t
To Controller
TE-63xS Series Strap-Mount Temperature Sensors
Installation Instructions
TE-631S-1, TE-635S-1
TE-636S-1
Part No. 24-4034-239, Rev. D
Issued March 2016
24- 4034-239, Rev. D
TE-63xS Series Strap-Mount Temperature Sensors Installation Instructions2
Wiring
For 1k ohm nickel temperature sensors, wire
resistance can cause approximately 1F° (0.56C°) of
error for every 250 ft (76 m) run of 18 AWG (1.0 mm
diameter) wire, or every 100 ft (31 m) run of 22 AWG
(0.6 mm diameter) wire. To minimize error due to field
wiring, limit total resistance of all nickel temperature
sensor wiring to 3 ohms.
The 10k ohm thermistor applications tolerate relatively
long wiring before the wire resistance adds significantly
to total resistance measured at the controller. As a
general rule, a 150 ft (46 m) two-wire 18 AWG
(1.0 mm diameter) run contributes 2 ohms of error, or
less than 1F° (0.56C°) error over the sensor operating
temperature range.
Refer to the appropriate controller documentation for
recommended sensor wiring.
Repair Information
If the TE-63xS Series Strap-Mount Temperature
Sensor fails to operate within its specifications, replace
the unit. For a replacement sensor, contact the nearest
Johnson Controls
® representative.
!
CAUTION: Risk of Property Damage.
Do not apply power to the system before
checking all wiring connections. Short
circuited or improperly connected wires
may result in permanent damage to the
equipment.
MISE EN GARDE : Risque de dégâts
matériels.
Ne pas mettre le système sous tension
avant d'avoir vérifié tous les raccords de
câblage. Des fils formant un court-circuit
ou connectés de façon incorrecte
risquent d'endommager
irrémédiablement l'équipement.
IMPORTANT: Use copper conductors only. Make
all wiring connections in accordance with local,
national, and regional regulations. Do not exceed
the TE-63xS Series Strap-Mount Temperature
Sensor’s electrical ratings.
Published in U.S.A. www.johnsoncontrols.com
TE-63xS Series Strap-Mount Temperature Sensors Installation Instructions 3
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners. © 2016 Johnson Controls, Inc.
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Technical Specifications
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or
misuse of its products.
TE-63xS Series Strap-Mount Temperature Sensors
Models TE-631S-1 1k ohm Thin-Film Nickel Temperature Sensor
TE-635S-1 1k ohm Thin-Film Platinum Temperature Sensor
TE-636S-1 10k ohm Thermistor Johnson Controls Type II Temperature Sensor
Sensor Reference
Resistance
1k ohm Nickel 1k ohms at 70°F (21°C)
1k ohm Platinum 1k ohms at 32°F (0°C)
10k ohm Thermistor 10.0k ohms at 77F (25C)
Sensor Accuracy 1k ohm Nickel 0.34F° at 70F (0.19C at 21C)
1k ohm Platinum 0.35F° at 70F (0.19C at 21C), DIN Class A
10k ohm Thermistor 0.9F (0.5C) in the Range: 32 to 158F (0 to 70C)
Sensor Temperature
Coefficient
1k ohm Nickel Approximately 3 ohms/F° (5.4 ohms/C°)
1k ohm Platinum Approximately 2 ohms/F° (3.9 ohms/C°) 3850 ppm/K
10k ohm Thermistor Nonlinear Negative Temperature Coefficient, Johnson Controls Type II
Electrical Connections 22 AWG (0.6 mm Diameter) x 10 ft (3 m) Long Plenum-Rated Cable,
White Leads
Probe Materials 1/4 in. (6.4 mm) Outside Diameter x 3 in. (76 mm) Stainless Steel
Operating Temperature
Limits
Cable -50 to 140F (-46 to 60C)
Probe -50 to 220F (-46 to 104C)
European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact:
JOHNSON CONTROLS
WESTENDHOF 3
45143 ESSEN
GERMANY
JOHNSON CONTROLS
507 E MICHIGAN ST
MILWAUKEE WI 53202
USA
JOHNSON CONTROLS
C/O CONTROLS PRODUCT
MANAGEMENT
NO. 22 BLOCK D NEW DISTRICT
WUXI JIANGSU PROVINCE 214142
CHINA
  • Page 1 1
  • Page 2 2
  • Page 3 3

Johnson Controls TE-63xS Series Guide d'installation

Taper
Guide d'installation

dans d''autres langues