Garland MST54 Manuel utilisateur

Taper
Manuel utilisateur
Part # 4525958 (05/15/09) Page 1
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES,LLC
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD.
5E Langley Business Centre
Station Road, Langley SL3 8DS Great Britain
Phone: 01753 485900
Fax: 01753 4859011
Part # 4525958 (05/15/09) © 2008 Garland Commercial Industries, LLC
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER.
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained by consulting
your local gas supplier.
INSTALLATION AND
OPERATION MANUAL
GARLAND G-BRL & GF-BRL
SERIES BROILERS
Includes Models: G18-BRL, G24-BRL, G30-BRL,
G36-BRL, G48-BRL, GF18-BRL,GF24-BRL,GF30-BRL
and GF36-BRL
Only GF Series Broilers are CE Approved
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13
Españo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Página 27
Part # 4525958 (05/15/09)Page 2
IMPORTANT INFORMATION
WARNING:
This product contains chemicals known to the State of California to cause cancer and/or birth
defects or other reproductive harm. Installation and servicing of this product could expose you
to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/
ceramic fibers is known to the State of California to cause cancer. Operation of this product could
expose you to carbon monoxide if not adjusted properly. Inhalation of carbon monoxide is known
to the State of California to cause birth defects or other reproductive harm.
Keep appliance area free and clear of combustibles.
Part # 4525958 (05/15/09) Page 3
TABLE OF CONTENTS
IMPORTANT INFORMATION..........................................2
DIMENSIONS AND SPECIFICATIONS – BROILERS.......................4
North America & General International Markets................................4
Australian Market ............................................................4
CE Aproved Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Pressure Settings/Injector Size ................................................5
Heat Input ...................................................................5
Gas Inlet Size.................................................................5
GF Series CE Approved Gas Categories ........................................5
Approximate Total Input Ratings With All Burners Operating At LOW...........5
DIMENSIONS AND SPECIFICATIONS – STANDS ........................6
PRE INSTALLATION..................................................7
Unpacking .......................................................................7
Safety Information ...............................................................7
INSTALLATION ......................................................7
Rating Plate Location .............................................................7
Statutory Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Australia Specic Regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Gas Connections .................................................................8
Counter Line Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Location .....................................................................8
Sanitary Counter Top Seal.....................................................8
Leg Installation...............................................................9
Assembly Of Counter Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installation for Units Equipped with Casters...................................10
Cabinet Bases ...............................................................10
Assembly Of Broiler .............................................................10
Ventilation ......................................................................10
OPERATION........................................................11
Grid Rack Seasoning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Lighting Instructions ............................................................11
CLEANING AND MAINTENANCE .....................................12
Cleaning Care of the Grid Racks ..................................................12
Exterior Finish Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Part # 4525958 (05/15/09)Page 4
REAR GAS
CONNECTION
3/4-14 NPT
7-7/8"
[200mm]
2-3/8"
[61mm]
34-1/2"
[876mm]
24-1/4"
[617mm]
5"
[127mm]
5-7/8"
[149mm]
WIDTH
25-1/8"
[638mm]
3/16" [5mm] MIN
1/2" [13mm] MAX
22-3/8"
[568mm]
7/8" [21mm]
2-1/8"
[53mm]
15-7/8"
[404mm]
3"
[77mm]
22-1/8"
[562mm]
31-1/8"
[709mm]
REAR GAS CONNECTION
3/4-14 NPT
4"
[100mm]
14-3/4"
[375mm]
5"
[125mm]
DIMENSIONS AND SPECIFICATIONS – BROILERS
Product Dimensions and Shipping Specializations
North American and CE
1
Inputs
Model Width
Height
W/O Legs
Depth
Shipping
No of
Burners
Total Input Ratings
lbs/kg Cu Ft BTU/Hr kW/Hr
G18-BRL 18" (457mm) 25-1/8" (636mm) 34-1/2" (876mm) 190/86 21 3 45,000 13.2
G24-BRL 24" (610mm) 25-1/8” (636mm) 34-1/2" (876mm) 240/109 21 4 60,000 17.6
G30-BRL 30" (762mm) 25-1/8” (636mm) 34-1/2" (876mm) 290/131 29.5 5 75,000 22
G36-BRL 36" (914mm) 25-1/8” (636mm) 34-1/2" (876mm) 340/154 29.5 6 90,000 26.4
G48-BRL 48" (1219mm) 25-1/8” (636mm) 34-1/2" (876mm) 375/170 37 8 120,000 35.2
1
GF18-BRL 18" (457mm) 25-1/8” (636mm) 34-1/2" (876mm) 190/86 21 3 45,000 12.0
1
GF24-BRL 24" (610mm) 25-1/8” (636mm) 34-1/2" (876mm) 240/109 21 4 60,000 16.0
1
GF30-BRL 30" (762mm) 25-1/8” (636mm) 34-1/2" (876mm) 290/131 29.5 5 75,000 20.0
1
GF36-BRL 36" (914mm) 25-1/8” (636mm) 34-1/2" (876mm) 340/154 29.5 6 90,000 24.0
1
NOTE: Only GF series broilers with ame failure features are CE approved.
North America & General International Markets
Operating Manifold Pressure
Natural (G20)
4.5” wc
(11.2mbar)
LPG (G31)
10” wc
(24.9mbar)
G-BRL Models
Australian Market
Operating Manifold Pressure
Natural 4” wc (1.0kPa) LPG 10” wc (2.49 kpa)
Input Per Burner
MJ/H Injector Dia. MJ/H Injector Dia.
15.8 1.9 mm 15.8 1.1 mm
For use in non-combustible locations only.
Installation Clearances From
Non Combustible Materials (all models)
Rear Sides
0” 0”
Part # 4525958 (05/15/09) Page 5
DIMENSIONS AND SPECIFICATIONS – BROILERS continued
CE Aproved Models
Pressure Settings/Injector Size
MODEL
2nd Family, Groups H, L & E 3rd Family, Group 3P
Setting Pressure
Injector Size
Setting Pressure
Injector Size
G20 @ 20
mbar inlet
G25 @ 25
mbar inlet
G31 @ 37/50 mbar
inlet
mbar “WC mbar WC DMS mm mbar “WC DMS mm
GF18-BRL 11.2 4.5 14.9 6 50 1.78 24.9 10 58 1.07
GF24-BRL 11.2 4.5 14.9 6 50 1.78 24.9 10 58 1.07
GF30-BRL 11.2 4.5 14.9 6 50 1.78 24.9 10 58 1.07
GF36-BRL 11.2 4.5 14.9 6 50 1.78 24.9 10 58 1.07
Heat Input
MODEL
2nd Family, Groups H & E 2nd Family, Group L 3rd Family, Group 3P
# Of
Burners
(G20 @ 20/25 mbar) NAT (G25 @ 25 mbar) NAT (G31 @ 37/50 mbar) PROPANE
Per Burner / Total Per Burner / Total Per Burner / Total
kW BTU/HR kW BTU/HR kW BTU/HR
GF18-BRL 4.0 / 12.0 15,000 / 45,000 4.0 / 12.0 15,000 / 45,000 4.0 / 12.0 15,000 / 45,000
3
GF24-BRL 4.0 / 16.0 15,000 / 60,000 4.0 / 16.0 15,000 / 60,000 4.0 / 16.0 15,000 / 60,000
4
GF30-BRL 4.0 / 20.0 15,000 / 75,000 4.0 / 20.0 15,000 / 75,000 4.0 / 20.0 15,000 / 75,000
5
GF36-BRL 4.0 / 24.0 15,000 / 90,000 4.0 / 24.0 15,000 / 90,000 4.0 / 24.0 15,000 / 90,000
6
Gas Inlet Size
Model Width Connection Connection CE Models (ISO7-1)
23-5/8” (600mm) & 35-1/2” (900mm) 3/4” NPT Rear Gas Connection 3/4” (19.1mm) BSPT
A*
REAR GAS
CONNECTION
1-3/8"
[45mm]
34-1/2"
[876mm]
24-1/4"
[617mm]
5"
[127mm]
5-7/8"
[149mm
WIDTH
25-1/8"
[638mm]
3/16"
[5mm] MIN
1/2"
[13mm] MAX
22-3/8"
[568mm]
7/8" [21mm]
5-5/8"
[143mm]
2"
[53mm]
15-7/8"
[404mm]
3"
[77mm]
22-1/8"
[562mm]
31-1/8"
[91mm]
14-3/4"
[375mm]
3-5/8"
[94mm]
REAR GAS
CONNECTION
GF-BRL Models
*For units supplied with regulator dimension A is 7-7/8” (200mm) with a 3/4” – 14 NPT connection.
European (CE) units are not supplied with regulator, but include with an adaptor 3/4” –14 BSPT.
GF Series CE Approved Gas Categories
Country
Gas
Category
Gas
Type
Pressure
(mbar)
GB, IE, ES, PT, GR I2H G20 20
BE, FR I2E+ G20 20/25
DE I2E G20 20
GB, IE, ES, PT, BE, FR I3P G31 37
GB, FR, NL, DE, ES I3P G31 50
NL I3P G31 30
Approximate Total Input Ratings
With All Burners Operating At Low
kW BTU/h
GF18-BRL 4.5 16,875
GF24-BRL 6.0 22,500
GF30-BRL 7.5 28,125
GF36-BRL 9.0 33,750
Part # 4525958 (05/15/09)Page 6
DIMENSIONS AND SPECIFICATIONS – STANDS
Model
Number
Description
Use With
Broiler Model
Cu. Ft.
Ship
Weight
Lb/ Kg
G18-BRL-STD Floor Stand 18” (457mm) Wide G18-BRL & GF18-BRL 4.5 30/14
G24-BRL-STD Floor Stand 24” (610mm) Wide G24-BRL & GF24-BRL 4.5 40/18
G30-BRL-STD Floor Stand 30” (762mm) Wide G30-BRL & GF30-BRL 4.5 50/23
G36-BRL-STD Floor Stand 36” (914mm) Wide G36-BRL & GF36-BRL 4.5 55/25
G48-BRL-STD Floor Stand 48” (1219mm) Wide G48-BRL 5.5 58/26
G18-BRL-CAB Closed Cabinet 18” (457mm) Wide G18-BRL & GF18-BRL 21 40/18
G24-BRL-CAB Closed Cabinet 24” (610mm) Wide G24-BRL & GF24-BRL 21 45/20
G30-BRL-CAB Closed Cabinet 30” (762mm) Wide G30-BRL & GF30-BRL 29.5 50/23
G36-BRL-CAB Closed Cabinet 36” (914mm) Wide G36-BRL & GF36-BRL 29.5 60/27
G48-BRL-CAB Closed Cabinet 48” (1219mm) Wide G48-BRL 37 65/29.5
• Manylocalcodesexist,anditistheresponsibilityoftheOwnerandtheInstallertocomplywiththosecodes.
• Garlandreservestherighttochangeorimproveproductspecificationswithoutnotification.
• Garlandproductsarenotapprovedorauthorizedforhomeorresidentialuse,butareintendedforcommercialapplica-
tions only. Garland will not provide service, warranty, maintenance or support of any kind other than in commercial
applications.
WIDTH
21"
[534mm]
LEG MAX
20"
[ 509mm]
LEG MIN
20"
[508mm]
NON ADJ
CASTER
20-7/16"
[529mm]
MAX ADJ
CASTER
20-3/16"
[513mm]
MIN ADJ
CASTER
31-3/16"
[719mm]
DEPTH
G24-BRL-CAB
WIDTH
20-5/16"
[516mm]
LEG MAX
19-7/16"
[504mm]
LEG MIN
20"
[508mm]
CASTERS
31-3/16"
[792mm]
DEPTH
G24-BRL-STD
Part # 4525958 (05/15/09) Page 7
Unpacking
GARLAND strongly recommends this unit be inspected for
possible freight damage while carrier driver is on site.
1. Remove carton. In case of damage, all packing materials
must be retained for carrier inspection.
2. Carefully inspect the broiler for any physical signs of
damage, such as scratches, dents and missing knobs.
3. With carrier driver on your site, note damage on freight
bill. Call carrier for inspection.
If you are checking equipment after carrier has departed,
you have approximately fteen (15) days to request a freight
damage inspection be made by the carriers agent.
If concealed damage claim is led with carrier beyond 15
days, GARLAND cannot be held responsible and carrier will
make it incumbent upon the consignee to oer reasonable
evidence that the carrier was at fault.
Safety Information
WARNING: Accessible parts may become hot during use.
Young children should be kept away.
This appliance is for professional use and should only be
used by qualied personnel.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
PRE INSTALLATION
INSTALLATION
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prex and sux
letters and numbers) and the warranty serial number. The
rating plate axed to the unit contains this information.
We suggest installation, maintenance, and repairs should be
performed by your local authorized service agency listed in
your information manual pamphlet.
In the event you have any questions concerning the
installation, use, care or service of the product, write or call
our Product Service Department.
This product must be installed by professional personnel as
specied. Garland/U.S. Range products are not approved or
authorized for home or residential use, but are intended for
commercial applications only. Garland / U.S. Range will not
provide service, warranty, maintenance, or support of any
kind other than in commercial applications.
Rating Plate Location
The rating plate is located by removing the grease tray, it is
located on left hand side grease slide support.
Statutory Regulations
Installation must be carried out by a competent person and
in accordance with the relevant regulations, codes of practice
and the related publications of the country of destination.
In European countries, installation must be carried out by
a competent person and in accordance with the relevant
regulations, codes of practice and the related publications of
the country of destination.
In The United States of America, the installation must
conform to the National Fuel Gas Code ANSI Z223.1, or latest
edition, NFPA No.54 - latest edition/or local code to assure
safe and ecient operation. In Canada, the installation must
comply with CSA B149.1 and local codes.
Australia Specic Regulation
This appliance must be installed in accordance with the
manufacturer’s instructions, local gas tting regulations and
requirements of AS 5601/AG 601 installation code. All burner
adjustments and setting should be made by a qualied gas
technician.
Part # 4525958 (05/15/09)Page 8
INSTALLATION continued
Gas Supply
A. The type of gas for which the unit is equipped is stamped
on the rating plate. Connect a unit stamped “NAT” only
to natural gas; connect those stamped “PRO” only to
propane gas.
B. If it is a new installation, have gas authorities check meter
size and piping to assure that the unit is supplied with
sucient amount of gas pressure required to operate the
unit.
C. If it is additional equipment or replacement, have a
qualied gas technician check the gas pressure to make
certain that existing gas facilities (meter, piping, etc.) will
deliver the BTU’S of gas required at the unit with no more
than 1/2” water column pressure drop. When checking
pressure, be certain that other equipment on the same
gas line is on at full rate.
NOTE: When checking pressure, be sure that all other
equipment on the same gas line is on. If the broiler has
been supplied with a regulator it has been preset to
match specications on the unit’s rating plate. All units
require regulators and should be adjusted accordingly to
manufacturer specications.
D. The appliance and its individual shut o (supplied by
others) must be disconnected from the gas supply piping
system during any pressure testing of that system at
pressures in excess of 1/2 PSI (3.45 KPa).
E. Gas supply connection is made in back lower left hand
corner of unit. A readily accessible approved type of hand
valve should be installed on each supply line. Test for
leaks – Do Not Use An Open Flame.
F. A pressure tap plug is supplied with the units and it
is installed on the manifold. The valve panel must be
removed to use the pressure tap. The gas pressure must
be checked when the unit is installed, to insure that the
unit gas pressure is the same as specied on the rating
plate. If necessary, pressure adjustments must be made at
the pressure regulator.
G. If it is a completely new installation, have gas lines,
meter size piping and piping installed and checked by a
qualied gas technician.
H. Make certain that the new piping, joints, and connections
have been made in a clean manner and have been
purged, so that the piping compound, chips, etc., will not
clog pilots, valves, and/or controls. Use pipe joint sealant
that is resistant to liqueed petroleum gas.
WARNING: Check gas connections for leaks. Use a soap
solution or similar means. Do Not Use An Open Flame!
Gas Connections
All broilers have a rear gas 3/4” NPT or 3/4”-14NPT
connections. CE models have 3/4”-14 BSPT thread adapter.
NOTE: Adequate clearance must be provided for servicing
and proper operation.
Counter Line Installations
Location
Unpack units carefully and provide the necessary space
on counter or back bar. All units must be installed in non-
combustible locations.
A. Location of the unit should be in an area where
make-up air is available to support proper combustion.
Make-up air should be supplied in such a manner as to
pass through the front of the unit. Do not obstruct front-
air ow.
B. In accordance with standard gas appliance operation,
the unit should be located under a ventilation hood of
applicable size and capacity. See ventilation instructions.
Sanitary Counter Top Seal
When the broiler is installed on a counter top, the National
Sanitation Foundation, (NSF), recommends that it be
sealed in accordance with NSF standards per the following
instructions:
1. Unit should be located on a non-combustible, level
counter top surface.
2. Thoroughly clean the bottom perimeter of the broiler and
the counter top around the bottom of the broiler.
3. Apply a generous bead of silicone sealant around the
entire outside perimeter of the broiler bottom.
4. The broiler can be secured to the counter top by inserting
the 3/8-inch diameter crating bolts through the counter
from the bottom, (via predrilled 1/2” diameter holes), and
threading them into the nut inserts in the bottom of the
unit.
5. Smooth the silicone sealant with a nger or tool to
provide a cover seal.
Part # 4525958 (05/15/09) Page 9
INSTALLATION continued
Leg Installation
1. All units are shipped with N.S.F. approved legs. These legs
must be installed to provide a minimum clearance of
four (4) inches between the counter top and bottom of
the unit in order to meet National Sanitation Foundation
requirements.
2. When using the legs described above, raise front of unit
and screw leg into leg retaining nut provided at each
corner of unit, repeat at rear.
3. Unit may be leveled by adjusting legs. Use a spirit level
and level unit (by cooking grids) four (4) ways: across the
front and back and down the sides.
Assembly Of Counter Stand
SLEEVE ASSEMBLY
SHELF
SIDE LEG
ASSEMBLY
DETAIL 2
DETAIL 1
1. Slide the side leg assembly into the sleeve assembly and
fasten with a screw and a nut in 8 places (2 per joint) as
shown in detail 1.
DETAIL 1
10-24 X 3/8"
MACHINE SCREW
10-24
LOCK NUT
2. Place the center support bracket inside of the sleeve
assembly. Mount the center support to the bracket with
2 screws and nuts (detail 2). Repeat for the other side.
Sleeve assemblies should be sandwiched between the
center support and center support bracket. Repeat for
other center support.
10-24 X 3/8"
MACHINE SCREW
10-24
LOCK NUT
CENTER
SUPPORT
BRACKET
DETAIL 2
3. Prior to placing the unit on the stand:
a. Remove levelling feet from unit.
b. Remove grates/rods/burners etc. to lighten unit and
team lift onto stand.
4. Attach the broiler to the stand at the back with (2) 1/4”
bolts, washers and lock nuts as shown. (One for each
corner.)
NOTE: for 48” broiler there are (4) mounting locations at
the back.
1/4-20 LOCK NUT
1/4 WASHER
1/4-20 X 5/8 BOLT
FASTER ON BROILER
3/8 LOCK WASHER
3/8-16 X 5/8 BOLT
GF24 BROILER STAND
WITH LEGS SHOWN
5. Attach the broiler to the stand at the front with (2) 3/8”
bolts & lock washers as shown. Bolt with thread into
fasteners attached to the bottom side of the broiler (one
for each corner).
NOTE: for 48” broiler there are (4) mounting locations at
the back.
Part # 4525958 (05/15/09)Page 10
Installation for Units Equipped with Casters
A. The installation shall be made with a connector that
complies with the Standard for Connectors for Moveable
Gas Appliances, ANSI Z./CSA ., Addenda
Z.B-/CSA .B- (or latest edition), and a
quick-disconnect device that complies with the Standard
for Quick Disconnects for Use with Gas Fuel, ANSI Z./
CSA ., Addenda Z.A-/CSA .A- (or latest
edition).
B. Raise the front of the appliance and block. Do not lay the
appliance on its back.
C. Caster are threaded to be easily screwed into the holes
provided on the bottom of the range. It is important to
add the washers supplied to help distribute force on the
range when being moved.
BOTTOM
OF
APPLIANCE
WASHER
PROTECTIVE
PLASTIC ON
THIS SIDE
FIXED CASTER
(SHOWN W/O BRAKE)
ADJUSTABLE CASTER
(SHOWN W/O BRAKE)
BOTTOM
OF
APPLIANCE
D. Place the washer on the caster stem as shown. Since
the washer is slightly cupped, it is critical that the side
with the plastic is up and mates with the bottom of the
appliance. With the washer in place, thread the caster
onto the appliance tightly. It is not necessary to remove
the plastic from the washer.
E. The front casters of the unit are equipped with brakes
to limit the movement of the unit without depending
on the connector and any quick-disconnect device or its
associated piping to limit the appliance movement.
F. Please be aware, there is a restraint on the unit and if
disconnection of the restraint is necessary, be sure to
reconnect the restraint after the unit has been returned
to its originally installed position.
Cabinet Bases
Cabinet base options are available for all broiler models.
Cabinets are pre-assembled at time of delivery except legs or
casters.
INSTALLATION continued
Assembly Of Broiler
Steel Grate Rods
Each broiler is supplied with (14) 15”/381mm, (18-BRL),
21”/533mm, (24-BRL), 26” /660mm, (30-BRL), 31”/787mm,
(36-BRL) or 2 sets of 21”/533mm (48-BRL) long steel rods.
These rods are to be installed in the grooves on the support
brackets, which are atop the burners.
Briquettes
For best cooking results, it is recommended that the correct
amount of briquettes are installed in the broiler. Refer to
the table and drawing below for the proper arrangement
of briquettes. When all the briquettes have been placed as
instructed, install the top grate sections.
MODEL 18-BRL 24-BRL 30-BRL 36-BRL 48-BRL
Rows
front
to rear
7 7 7 7 7
Rows
left
to right
7 11 14 17 22
Ventilation
The following notes are intended to give general guidance.
For detailed recommendations, refer to the applicable
code(s) in the country of destination.These appliances shall
be installed in a room with sucient ventilation to prevent
the occurrence of hazardous concentrations of combustion
by-products.
A good ventilation system is important for satisfactory
performance and it is recommended to install the broiler
under a power vented canopy.
Local and/or National Codes dictate the need of ventilation
system to be used with this type of equipment. The following
information is provided to give examples of available
ventilation system concepts.
Part # 4525958 (05/15/09) Page 11
INSTALLATION continued
OPERATION
Grid Rack Seasoning Instructions
To insure long life and service, it is imperative that the
cooking surface be carefully broken in or seasoned in the
following manner:
1. Remove all factory applied protective material by
washing with hot water and a mild detergent or soap
solution. Rinse and dry thoroughly.
2. Apply a thin coat of olive oil or other high grade salt free
cooking oil to the cooking surface. Wipe away excess.
3. Turn all valves to a low setting and allow grid racks to
heat slowly for thirty (30) minutes. Allow oil to remain on
cooking surface three (3) to four (4) minutes, then wipe o.
4. Reset valves to desired operating temperature and apply
a second coat of oil and leave for two (2) or three (3)
minutes after grid rack reaches temperature. Then wipe
o surplus.
Your broiler is now ready to use.
NOTE: Unless products contain sucient fat, grid racks must
be seasoned before each use. Re-season after thorough
cleaning of the cooking surface.
Lighting Instructions
Models G(18,24,39,36,48)-BRL
1. One pilot serves two burners and is located between
those burners.
2. Push red spark buttons several times to ignite pilot
burners.
3. Ensure pilots are lit by viewing through pilot view hole on
front of unit.
Models GF(18,24,30.36)-BRL
1. Push in the valve knob and turn counter-clockwise to the
ignition position.
2. While holding the knob fully in, depress the ignitor
button and visually conrm that the pilot lights are on.
If the pilot does not light, repeatedly press the ignitor
button until ignition is achieved.
3. After the pilot is lit, continue to hold the valve knob in for
at least 20 seconds, then release it. If the pilot goes out,
wait ve, (5), minutes, then repeat the procedure.
4. When the pilot is established, push in the valve knob
again and turn it counter-clockwise to the full ame
position, igniting the main burner.
5. For low ame or simmer, push in the valve knob and turn
it to the low ame position.
6. To turn the burner o, push in and turn the valve knob to
the circular “OFF” symbol.
Shut down
1. Turn all gas valves o.
2. If the unit is to be shut down for an extended period of
time, turn the in-line service valve to the “OFF” position,
(this valve is not factory supplied).
Two basic types of power ventilations are in use today. One
type is the overhead hood or canopy and the other is the
under shelf exhaust system. The latter oers simplicity of
installation and minimum cleaning expense. Both require
ame-proof lters for easy grease removal.
The ventilator must be connected to a duct of suitable size
with an exhaust blower capable of removing a minimum of
325 CFM’S of air per square foot of broiler surface.
Part # 4525958 (05/15/09)Page 12
CLEANING AND MAINTENANCE
Cleaning Care of the Grid Racks
Establish a regular cleaning schedule. It is necessary to
avoid obstruction and to allow proper combustion and
performance.
1. Grid racks should be wiped daily while still warm, using a
heavy cloth or other grease absorbing material to remove
grease and burnt food before they burn into the grid.
Remove burnt materials, such as carbonized grease or
food, with a sti wire brush. Do Not use Any Type Of Steel
wool. Small particles may be left on the grid surface and
get into food products.
2. Grid racks should be washed thoroughly using a wire
brush and a hot, mild detergent or soap solution. Rinse
with clear, warm water.
3. Dry thoroughly.
4. Re-season grid racks as outlined in seasoning
instructions.
5. Empty grease tray(s) frequently and wash daily in hot,
mild detergent or soap solution.
6. Do not waste gas or abuse equipment by leaving
valves at high temperature settings while not in
use. Throughout all idling periods, set valves as low
temperature setting to keep grids warm. Re-set valves as
required for periods of heavy load. Turn valves to OFF at
end of daily operation.
7. When the grill is running, never use objects such as
sheet pans to cover the gill in order to hold in heat in an
attempt to burn o grease or other debris.
Exterior Finish Cleaning
Establish a regular schedule. Any spills should be wiped o
immediately.
1. Wipe exposed, clean-able surface when cool with a mild
detergent and hot water. Stubborn residue spots may be
removed with a light weight non-metallic scouring pad.
Dry thoroughly with a clean cloth.
2. Stainless steel should be cleaned using a mild detergent,
a soft cloth, and hot water. If it is necessary to use a
non-metallic scouring pad, always rub in the direction of
the grain in the metal to prevent scratching. Use a water
based stainless steel cleaner (such as Drackett Twinkle), if
you want a high shine.
3. The side splash or main top of the broiler can be cleaned
with hot water and a soap solution. A degreaser may
be used as well. To make the cleaning easier, you may
remove the main top assembly. To remove the main top,
rst lift and remove all grids, then lift the main top o.
When nished cleaning, dry thoroughly and lightly coat
with cooking oil or spray with cooking oil such as PAM. If
not coated, rust will form.
Pièce nº 4525958 (05/15/09) Page 13
Part # 4525958 (05/15/09) © 2008 Garland Commercial Industries, LLC
L’attention des utilisateurs est attirée sur le fait que l’entretien et les réparations doivent être effectués par un agent
d’entretien autorisé par Garland utilisant des pièces de rechange d’origine Garland. Garland n’aura aucune obligation
en ce qui concerne nimporte quel produit mal installé, réglé, utilisé ou qui n’aurait pas été entretenu conformément
aux codes nationaux et locaux ou aux instructions d’installation fournies avec le produit ou nimporte quel produit
dont le numéro de série aurait été mutilé, oblitéré ou supprimé ou qui aurait été modifié ou réparé avec des pièces
non autorisées ou par des agents d’entretien non autorisés. Pour obtenir la liste des agents de service autorisés,
consulter le site web de Garland à : http://www.garland-group.com. Les renseignements contenus dans le présent
document (y compris la conception et les spécifications des pièces) peuvent être remplacés ou modifiés sans préavis.
POUR VOTRE SÉCURITÉ:
NE PAS STOCKER NI UTILISER D’ESSENCE OU
D’AUTRES VAPEURS OU LIQUIDES INFLAM-
MABLES À PROXIMITÉ DE CET APPAREIL OU
DE TOUT AUTRE APPAREIL.ER
APPLIANCE
AVERTISSEMENT :
UNE INSTALLATION, DES RÉGLAGES, DES
MODIFICATIONS, DES RÉPARATIONS OU UN
ENTRETIEN MAL FAITS PEUVENT CAUSER
DES DOMMAGES MATÉRIELS, DES BLES-
SURES OU LA MORT. LIRE SOIGNEUSEMENT
LES INSTRUCTIONS D’INSTALLATION,
D’UTILISATION ET D’ENTRETIEN
AVANT D’INSTALLER OU DE RÉPARER
L’ÉQUIPEMENT.
LIRE TOUTES LES SECTIONS DU PRÉSENT MAN-
UEL ET LE CONSERVER POUR S’Y REPORTER
ULTÉRIEUREMENT.
CE PRODUIT A ÉTÉ HOMOLOGUÉ EN TANT
QU’ÉQUIPEMENT PROFESSIONNEL DE CUISSON
ET DOIT ÊTRE INSTALLÉ PAR DU PERSONNEL
PROFESSIONNEL TEL QUE SPÉCIFIÉ.
DANS L’ÉTAT DU MASSACHUSETTS, CE PRODUIT
DOIT ÊTRE INSTALLÉ PAR UN PLOMBIER OU UN
MONTEUR D’INSTALLATION AU GAZ CERTIFIÉ.
Pour votre sécurité :
Placer dans un endroit bien en vue les instruc-
tions à suivre en cas d’odeur de gaz détectée
par l’utilisateur. Cette information peut être
obtenue auprès du fournisseur de gaz local.
MANUEL
D’INSTALLATION ET
D’UTILISATION
TISSOIRES GARLAND
SÉRIES G-BRL ET GF-BRL
Comprend les modèles : G18-BRL, G24-BRL,
G30-BRL, G36-BRL, G48-BRL, GF18-BRL,
GF24-BRL,GF30-BRL et GF36-BRL
Seules les rôtissoires série GF sont agréées CE
GARLAND COMMERCIAL INDUSTRIES, LLC
185 East South Street
Freeland, Pennsylvanie 18224
Téléphone : (570) 636-1000
Télécopieur : (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Téléphone : 905-624-0260
Télécopieur : 905-624-5669
Enodis UK LTD.
5E Langley Business Centre
Station Road, Langley SL3 8DS Great Britain
Téléphone : 01753 485900
Télécopieur : 01753 485901
Pièce nº 4525958 (05/15/09)Page 14
INFORMATIONS IMPORTANTES
AVERTISSEMENT :
Ce produit contient des produits chimiques reconnus par l’état de Californie comme causant le
cancer et/ou des malformations congénitales ou d’autres problèmes de reproduction. Linstallation
et l’entretien de ce produit peut vous exposer aux poussières de laine de verre/fibres céramiques.
Linhalation de ces particules de laine de verre ou de fibres céramiques est reconnue par l’état de
Californie comme causant le cancer. L’utilisation de ce produit peut vous exposer au monoxyde
de carbone en cas de mauvais réglage. Linhalation de monoxyde de carbone est reconnue par
l’état de Californie comme pouvant causer des malformations congénitales ou d’autres problèmes
reproductifs.
Maintenir les abords de l’appareil dégagés et
ne pas y stocker de produits combustibles.
Pièce nº 4525958 (05/15/09) Page 15
TABLE DES MATIÈRES
INFORMATIONS IMPORTANTES .....................................14
DIMENSIONS ET SPÉCIFICATIONS - RÔTISSOIRES .....................16
Marchés Nord-Américain Et Internationaux Généraux .........................16
Marché Australien ...........................................................16
Modèles homologués CE ........................................................17
Réglages De Pression/Taille Des Injecteurs....................................17
Débit Calorique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dimension D’entrée Du Gaz..................................................17
Série GF - Homologué CE - Catégories de gaz.................................17
DIMENSIONS ET SPÉCIFICATIONS - SOCLES ..........................18
PRÉINSTALLATION .................................................19
Déballage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Informations De Sécurité ........................................................19
INSTALLATION .....................................................19
Emplacement De La Plaque Signalétique .........................................19
Réglementation Légale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Clause Spécique à l’Australie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Alimentation En Gaz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Gas Connections ................................................................20
Installations Sur Plan De Travail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Emplacement ...............................................................20
Joint Sanitaire De Plan De Travail ............................................21
Installation des pieds ........................................................21
Montage Des Socles De Plan De Travail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Installation Des Appareils Équipés De Roulettes...............................22
Bases De Meuble ............................................................22
Montage De La Rôtissoire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Ventilation ......................................................................23
FONCTIONNEMENT ................................................24
Instructions D’apprêtage De La Crémaillère De Grille . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Instructions dallumage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
ENTRETIEN ET NETTOYAGE .........................................25
Nettoyage des crémaillères de grille . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Nettoyage Du Fini Extérieur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Pièce nº 4525958 (05/15/09)Page 16
DIMENSIONS ET SPÉCIFICATIONS - RÔTISSOIRES
Dimensions Des Produits Et Spécialisations D’expédition
Amérique du Nord et CE
1
Entrées
Modèle Largeur
Hauteur
Sans Pieds
Profondeur
Expédition
Nb De
Brûleurs
Débits Caloriques
Totaux
lbs/kg Cu Ft BTU/Hr kW/Hr
G18-BRL 18 po(457mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 190/86 21 3 45,000 13.2
G24-BRL 24 po(610mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 240/109 21 4 60,000 17.6
G30-BRL 30 po(762mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 290/131 29.5 5 75,000 22
G36-BRL 36 po(914mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 340/154 29.5 6 90,000 26.4
G48-BRL 48 po(1219mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 375/170 37 8 120,000 35.2
1
GF18-BRL 18 po(457mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 190/86 21 3 45,000 12.0
1
GF24-BRL 24 po(610mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 240/109 21 4 60,000 16.0
1
GF30-BRL 30 po(762mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 290/131 29.5 5 75,000 20.0
1
GF36-BRL 36 po(914mm) 25-1/8 po(636mm) 34-1/2 po(876mm) 340/154 29.5 6 90,000 24.0
1
NOTA : Seules les rôtissoires série GF avec fonctions de détection de amme sont agréées CE
Marchés Nord-Américain Et
Internationaux Généraux
Pression De Fonctionnement Du Collecteur
Natural (G20)
4,5 po CE
(11,2 mbars)
LPG (G31)
10 po wc
(24,9mbar)
Modèles G-BRL
Marché Australien
Pression De Fonctionnement Du Collecteur
Natural 4 po CE (1.0kPa) LPG 10po CE (2,49 kpa)
Entrée par brûleur
MJ/H Dia. Injecteur. MJ/H Dia. Injecteur.
15,8 1,9 mm 15,8 1,1 mm
Pour utilisation dans des emplacements
incombustibles uniquement.
Dégagements d’installation par rapport aux
matériaux non combustibles(Tous les modèles)
Arrière Côtés
0 po 0 po
Pièce nº 4525958 (05/15/09) Page 17
DIMENSIONS ET SPÉCIFICATIONS – RÔTISSOIRES (suite)
Modèles homologués CE
Réglages De Pression/Taille Des Injecteurs
MODÈLE
2ème Famille Groupes H L et E 3ème Famille Groupe 3p
Pression De Réglage
Taille Injecteur
Pression De Réglage
Taille Injecteur
Entrée G20 à
20 mbar
Entrée G25 à
25 mbar
Entrée G31 à 37/50
mbar
mbar po CE mbar po CE DMS mm mbar po CE DMS mm
GF18-BRL 11,2 4,5 14,9 6 50 1,78 24,9 10 58 1,07
GF24-BRL 11,2 4,5 14,9 6 50 1,78 24,9 10 58 1,07
GF30-BRL 11,2 4,5 14,9 6 50 1,78 24,9 10 58 1,07
GF36-BRL 11,2 4,5 14,9 6 50 1,78 24,9 10 58 1,07
Débit Calorique
MODÈLE
2ème Famille, Groupes H Et E 2ème famille, Groupe, L 3ème Famille, Groupe 3P
Nb De
Brûleurs
(G20 à 20/25 mbar) Gaz nat. (G25 à 25 mbar) Gaz nat. (G31 à 37/50 mbar) PropaneE
Par Brûleur / Total Par Brûleur / Total Par Brûleur / Total
kW BTU/H kW BTU/H kW BTU/H
GF18-BRL 4,0 / 12,0 15 000 / 45 000 4,0 / 12,0 15 000 / 45 000 4,0 / 12,0 15 000 / 45 000
3
GF24-BRL 4,0 / 16,0 15 000 / 60 000 4,0 / 16,0 15 000 / 60 000 4,0 / 16,0 15 000 / 60 000
4
GF30-BRL 4,0 / 20,0 15 000 / 75 000 4,0 / 20,0 15 000 / 75 000 4,0 / 20,0 15 000 / 75 000
5
GF36-BRL 4,0 / 24,0 15 000 / 90 000 4,0 / 24,0 15 000 / 90 000 4,0 / 24,0 15 000 / 90 000
6
Dimension D’entrée Du Gaz
Largeur Du Modèle Connexion Connexion Modèles CE (ISO7-1)
23-5/8 po (600mm) & 35-1/2 po (900mm) Connexion Arrière Du Gaz 3/4 Po NPT 3/4 po (19,1mm) BSPT
A*
CONNEXION
ARRIÈRE DU GAZ
CONNEXION
ARRIÈRE
DU GAZ
1-3/8"
[45mm]
34-1/2"
[876mm]
24-1/4"
[617mm]
5"
[127mm]
5-7/8"
[149mm
LARGEUR
25-1/8"
[638mm]
3/16"
[5mm] MIN
1/2"
[13mm] MAX
22-3/8"
[568mm]
7/8" [21mm]
5-5/8"
[143mm]
2"
[53mm]
15-7/8"
[404mm]
3"
[77mm]
22-1/8"
[562mm]
31-1/8"
[91mm]
14-3/4"
[375mm]
3-5/8"
[94mm]
Modèles GF-BRL
*Pour les unités livrées avec régulateur, la dimension «A» est de 7-7/8 po (200 mm) avec une connexion 3/4 po – 14 NPT.
Les unités destinées à l’Europe (CE) ne sont pas livrées avec régulateur, mais avec un adaptateur 3/4 po –14 BSPT.
Série GF - Homologué CE - Catégories de gaz
Pays
Catégorie
De Gaz
Type De
Gaz
Pression
(mbar)
GB, IE, ES, PT, GR I2H G20 20
BE, FR I2E+ G20 20/25
DE I2E G20 20
GB, IE, ES, PT, BE, FR I3P G31 37
GB, FR, NL, DE, ES I3P G31 50
NL I3P G31 30
Rapprochez Les Estimations Totales D’entrée Avec
Tous Les Brûleurs Fonctionnant Au BAS
kW BTU/H
GF18-BRL 4.5 16,875
GF24-BRL 6.0 22,500
GF30-BRL 7.5 28,125
GF36-BRL 9.0 33,750
Pièce nº 4525958 (05/15/09)Page 18
DIMENSIONS ET SPÉCIFICATIONS - SOCLES
Numéro De
Modèle
Description
À Utiliser Avec
Rôtissoire Modèle
pi³
Poids
d’expédition
Lb/ Kg
G18-BRL-STD Socle De Plancher 18 po (457 mm) De Large G18-BRL & GF18-BRL 4,5 30/14
G24-BRL-STD Socle De Plancher 24 Po (610mm) De Large G24-BRL & GF24-BRL 4,5 40/18
G30-BRL-STD Socle De Plancher 30 Po (762mm)De Large G30-BRL & GF30-BRL 4,5 50/23
G36-BRL-STD Socle De Plancher 36 Po (914mm) De Large G36-BRL & GF36-BRL 4,5 55/25
G48-BRL-STD Socle De Plancher 48 Po (1219mm) De Large G48-BRL 5,5 58/26
G18-BRL-CAB Meuble Fermé 18 po (457 mm) De Large G18-BRL & GF18-BRL 21 40/18
G24-BRL-CAB Meuble Fermé 24 Po (610mm) De Large G24-BRL & GF24-BRL 21 45/20
G30-BRL-CAB Meuble Fermé 30 Po (762mm) De Large G30-BRL & GF30-BRL 29,5 50/23
G36-BRL-CAB Meuble Fermé 36 Po (914mm) De Large G36-BRL & GF36-BRL 29,5 60/27
G48-BRL-CAB Meuble Fermé 48 Po (1219mm)De Large G48-BRL 37 65/29.5
• Ilexistedenombreuxcodeslocaux,etilestdelaresponsabilitédupropriétaireetdel’installateurderespecterces
codes.
• Garlandseréserveledroitdemodifieroud’améliorerlesspécificationsdesproduitssanspréavis.
• LesproduitsGarlandnesontpasagréésniautoriséspouruneutilisationpersonnelleourésidentielle,maissontdesti-
nés à des applications commerciales seulement.. Garland n’offre pas de services de paration, garantie, entretien ou
soutien de n’importe quelle sorte pour des applications autres que commerciales.
LARGEUR
21"
[534mm]
PIED MAX
20"
[ 509mm]
PIED MIN
20"
[508mm]
ROULETTE
NON RÉGL
20-7/16"
[529mm]
RÉGL. MAX.
ROULETTE
20-3/16"
[513mm]
RÉGL. MIN.
ROULETTE
31-3/16"
[719mm]
PROFONDEUR
G24-BRL-CAB
LARGEUR
20-5/16"
[516mm]
PIED MAX
19-7/16"
[504mm]
PIED MIN
20"
[508mm]
ROULETTES
31-3/16"
[792mm]
PROFONDEUR
G24-BRL-STD
Pièce nº 4525958 (05/15/09) Page 19
Déballage
GARLAND recommande fortement d’inspecter l’appareil
en présence du transporteur pour vérier la présence de
dommages causés pendant le transport.
1. Retirer la carton. En cas de dommage, tous les matériaux
d’emballage doivent être conservés pour inspection par
le transporteur.
2. Inspecter soigneusement la rôtissoire pour déceler les
signes de dommages comme des rayures, bosses et
boutons manquants.
3. Pendant que le conducteur du camion est sur place, noter
les dommages sur la facture de transport. Appeler le
transporteur pour demander une inspection.
En cas de vérication de l’équipement après le départ du
transporteur, vous avez environ quinze (15) jours pour
demander une inspection de dommages de transport par
l’agent du transporteur.
Si une réclamation de dommages non apparents est
déposée auprès du transporteur au-delà de 15 jours,
GARLAND ne peut pas être tenue pour responsable et le
transporteur demandera au destinataire de fournir la preuve
que le transporteur était responsable.
Informations De Sécurité
AVERTISSEMENT : Des pièces accessibles peuvent devenir
chaudes pendant l’utilisation. Maintenir les jeunes enfants
éloignés.
Cet appareil est pour à usage professionnel et devrait
seulement être employé par le personnel qualié.
Cet appareil n’est pas destiné à être utilisé par des
personnes (y compris des enfants) ayant des capacités
physiques, sensorielles ou mentales réduites ou un manque
d’expérience et de connaissances à moins quelles n’aient
reçu une supervision ou des instructions concernant
l’utilisation de cet appareil d’une personne responsable de
leur sécurité.
PRÉINSTALLATION
INSTALLATION
Pour correspondre avec l’usine ou le centre de service agréé
local concernant des problèmes de service ou des pièces de
rechange, bien faire référence à l’appareil avec le numéro de
modèle correct (comprenant les lettres et chires du préxe
et du suxe) et le numéro de série de garantie. La plaque
signalétique xée à l’appareil contient ces renseignements.
Nous suggérons de faire faire l’installation, l’entretien et les
réparations par une agence de service agrée locale gurant
dans la manuel d’informations.
En cas de questions concernant linstallation, l’utilisation,
l’entretien ou la réparation du produit, écrire ou
communiquer avec le département de service des produits.
Ce produit doit être installé par du personnel professionnel
tel que spécié. Les produits Garland/U.S. Range ne sont
pas agréés ni autorisés pour une utilisation personnelle
ou résidentielle, mais sont destinés à des applications
commerciales seulement. Garland / U.S. Range n’ore pas
de services de réparation, garantie, entretien ou soutien
de nimporte quelle sorte pour des applications autres que
commerciales.
Emplacement De La Plaque Signalétique
On découvre la plaque signalétique en retirant le plateau à
graisse; elle est située sur le support gauche de glissière du
plateau à graisse.
Réglementation Légale
Linstallation de cet appareil doit être faite par une personne
compétente et conformément aux règlements concernés,
codes de pratique et publications connexes du pays de
destination.
Dans les pays européens, linstallation doit être faite par une
personne compétente et conformément aux règlements
concernés, codes de pratique et publications connexes du
pays de destination.
Aux États-Unis, l’installation doit être conforme au National
Fuel Gas Code Code ANSI Z223.1, ou la dernière édition, la
norme NFPA No.54 – dernière édition/ou le code local pour
assurer un fonctionnement sécuritaire et ecace. Au Canada,
l’installation doit être conforme à la norme CSA B149.1 et aux
codes locaux.
Pièce nº 4525958 (05/15/09)Page 20
INSTALLATION (suite)
Clause Spécique à l’Australie
Cet appareil doit être installé conformément aux instructions
du fabricant, aux règlements locaux relatifs aux raccords de
gaz et aux exigences du code d’installation AS 5601 / AG
601. Tous les réglages des brûleurs doivent être faits par un
technicien qualié spécialiste des appareils à gaz.
Alimentation En Gaz
A. Le type de gaz pour lequel l’appareil est équipé
est estampillé sur la plaque signalétique située
(modèles G80) derrière le panneau supérieur avant,
(modèles 80B-40SD & ESD) à l’intérieur des portes du
compartiment. Brancher un appareil estampillé “ NAT ”
au gaz naturel et un appareil estampillé “ PRO ” au gaz
propane.
B. S’il s’agit d’une installation neuve, faire vérier par
le fournisseur de gaz le diamètre du compteur et
des conduites an de s’assurer que l’appareil reçoit
une pression de gaz susante pour fonctionner
correctement.
C. S’il s’agit d’un équipement supplémentaire ou de
remplacement, faire vérier la pression du gaz par un
technicien qualié an de s’assurer que les installations
de gaz existantes (compteur, tuyauteries, etc.) fourniront
les BTU dont l’appareil a besoin avec une chute de
pression ne dépassant pas 1/2 po de colonne d’eau. Lors
de la vérication de la pression, s’assurer que les autres
équipements sur la même conduite de gaz fonctionnent
à leur débit maximal.
NOTA : Pour vérier la pression du gaz, s’assurer que tous les
autres équipements branchés sur la même conduite de gaz
sont allumés. Si la rôtissoire a été livrée avec un régulateur,
celui-ci a été préréglé pour correspondre aux spécications
de la plaque signalétique de l’unité. Toutes les unités ont
besoin de régulateurs et doivent être ajustées conformément
aux spécications du fabricant.
D. Cet appareil et son robinet d’arrêt du gaz individuel (non
fourni par Garland) doivent être débranchés du système
d’alimentation en gaz lors de tout essai de pression de ce
système à des pressions dépassant 1/2 lb/po
2
(3,45 kPa).
E. Le branchement d’alimentation en gaz est situé dans
le coin arrière inférieur gauche de l’appareil. Un robinet
manuel facilement accessible et de type homologué
devrait être installé sur chaque conduite d’alimentation.
Vérications des fuites – Ne pas utiliser de amme nue.
F. Un bouchon de prise de pression est fourni avec les
appareils et est installé sur le collecteur. Le panneau des
robinets doit être retiré pour utiliser la prise de pression.
Il est nécessaire de vérier la pression du gaz quand
l’appareil est installé, pour s’assurer que la pression
d’alimentation de l’appareil est identique à celle indiquée
sur la plaque signalétique. Si nécessaire, des réglages de
pression doivent être faits au régulateur de pression.
G. S’il s’agit d’une installation complètement nouvelle,
faire installer et vérier les conduites de gaz, la taille du
compteur et celles des tuyauteries par un technicien en
gaz qualié.
H. S’assurer que les tuyauteries, joints et branchements
neufs ont été exécutés proprement et ont été purgés
de façon à ce que la graisse à letage, les copeaux,
etc. ne bouchent pas les robinets des veilleuses ni les
commandes. Utiliser du produit détanchéité pour joint
qui résiste au gaz de pétrole liquéé.
AVERTISSEMENT : Vérier la présence de fuites sur les
connexions de gaz. Utiliser une solution savonneuse ou une
méthode similaire. Ne pas utiliser de amme nue!
Gas Connections
Toutes les rôtissoires ont des connexions du gaz arrière
3/4 po NPT ou 3/4 po-14NPT. Les modèles CE ont un letage
3/4 po 14 NPT qui comprend un adaptateur.
NOTA : Un dégagement susant doit être prévu pour
l’entretien et l’utilisation.
Installations Sur Plan De Travail
Emplacement
Déballer soigneusement les appareils et prévoir l’espace
nécessaire sur le plan de travail ou la barre arrière. Tous
les appareils doivent être installés dans des endroits
incombustibles.
A. Lemplacement des appareils est vital et ils devront être
placés à un endroit où il y a susamment d’air d’appoint
pour assurer une combustion correcte. L’air d’appoint
devra être fourni de façon à passer par l’avant de
l’appareil. Ne pas obstruer le débit d’air par l’avant.
B. Conformément aux normes d’utilisation des appareils
à gaz, l’appareil devrait être placé sous une hotte de
ventilation de taille et de capacité correspondantes. Voir
les instructions de ventilation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Garland MST54 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues