Extron XTP R HWP 201 Manuel utilisateur

Taper
Manuel utilisateur
1
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
XTP R HWP 201 • Setup Guide
The XTP R HWP 201 is a single output XTP decorator-style wallplate receiver that can be installed into the provided mud ring or an optional UL
Listed metal junction box. This guide provides instructions for an experienced installer to install and connect the XTP R HWP 201.
Throughput,
Power, and Control
Connectors
Input, Control, and
Front Panel Features
A
XTP input
connector
B
DC power
connector
C
LAN connector
D
RS-232 and
IR Over XTP
connector
E
Analog audio
output connector
F
HDMI output
connector
G
USB configuration
connector
H
HDMI audio switch
I
Reset button
Figure 1. XTP R HWP 201 Rear (Left) and Front (Right) Panel Features
Installation
NOTE: If a junction box is required, use a metal box only.
Ensure the installation meets building, electrical, and safety codes.
For additional mounting considerations, see the XTP R HWP 201
User Guide at www.extron.com. For metal junction boxes, refer
to the manufacturer for additional mounting instructions and
considerations.
ATTENTION:
Do not mount multiple devices adjacent to each other
in the same metal junction box. Add at least a one gang
space between devices.
Ne procédez pas à une installation juxtaposée des
appareils dans le même boîtier de dérivation métallique.
Veuillez laisser un espace d’un gang minimum entre
chaque appareil.
Wall Mount Preparation
1. Using a soft pencil, mark cut guidelines on the mounting surface. For
accuracy, use a template or the mounting enclosure.
NOTE: Install junction boxes against a wall stud (see figure 2).
2. Cut a hole in the wall. To avoid making the hole too big, cut inside
the marked lines.
3. If using the mud ring in a wall with insulation inside, remove at least
6 inches of the insulation in all directions around the cutout. If a wall
stud interferes with removing the insulation, remove as much as
possible between the cutout and the wall stud.
4. Test the t by inserting the mud ring or metal junction box into the
hole in the wall. If necessary, enlarge the hole as needed.
5. Install the UL Listed junction box or provided mud ring.
UL Listed metal junction box — Use mounting screws to
fasten the box to a wall stud (see gure 2).
Provided mud ring — Attach the mounting screws to the mud
ring and loosely attach backing clips to the ends of the screws
(see gure 3). Fit the mud ring in the opening and then rotate
the backing clips to t snugly against the back of the wall.
XTP R HWP 201
12V
0.7 A MAX.
POWER
XTP IN
HDMI OUT
LAN
CONFIG
HDMI
AUDIO
ON
OFF
RESET
AUDIO
Tx
LR
IRRS-232
Rx Tx RxG
OVER XTP
Rear Front
A
B
F
G
H
I
D
E
C
XTP R HWP 201
Signal Output
Cable
Cable
Clamp
Decorator-Style Faceplate
Screws or
Nails
Wall opening is
flush with edge
of box.
Wall Stud
e
Figure 2. Metal Junction Box Installation
Backing Clip
Mounting Screw
Rotate the backing clip
out of the way to insert
the mud ring into the wall.
XTP R HWP 201
Decorator-Style Faceplate
e
Figure 3. Mud Ring Installation
2
Rear Panel Connections
1. Connect a twisted pair cable between the XTP connector (see figure 1,
A
on the previous page) of the XTP R HWP 201 and an XTP
transmitter.
ATTENTION:
Do not connect this connector to a computer data or telecommunications network.
Ne connectez pas ces port à des données informatiques ou à un réseau de
télécommunications.
The XTP R HWP 201 is compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) cable. Extron
recommends using the following practices to achieve full transmission distances up to 330 feet
(100 meters) and reduce transmission errors.
Use Extron XTP DTP 24 SF/UTP cable for the best performance. At a minimum, Extron recommends
24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points, punch down
connectors, couplers, and power injectors. If these pass-through points are required, use shielded
couplers and punch down connectors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the following:
Do not exceed 40% ll capacity in conduits.
Do not comb the cable for the rst 20 meters, where cables are straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
2. Power the XTP R HWP 201 in one of the following methods:
Connect the provided external power supply to the 2-pole captive screw connector for local 12 V power (see figure 1,
B
).
Connect an XTP Power Injector to the XTP connection between the transmitter and a locally powered XTP receiver or XTP matrix switcher.
Connect the XTP R HWP 201 to an XTP matrix switcher and enable the remote power feature on the XTP matrix switcher.
Device Installation
1. Using the provided screws, attach the XTP R HWP 201 to the mud ring or metal junction box through the inner screw holes (see
figure 2 or 3 on the previous page).
2. Using the provided screws, attach the faceplate to the XTP R HWP 201 through the outer screw holes (see figure 2 or 3).
NOTE: For configuration, control, and firmware upgrades, connect a host device to the USB mini-B connector before attaching the
faceplate (see figure 1,
G
, and see the XTP R HWP 201 User Guide for details).
Front Panel Connections
For LAN models, connect a host device or control LAN or WAN to the LAN RJ-45 connector for pass-through
10/100 Base-T Ethernet communication (see figure 1,
C
). This is an Ethernet pass-through port.
1. To pass bidirectional serial, infrared, or other control signals, connect a control device or controllable device
to the RS-232 and IR Over XTP connector (see figure 1,
D
). Wire the connector as shown to the right.
NOTE: RS-232 and IR data can be transmitted simultaneously.
2. Connect a balanced or unbalanced, stereo or
mono audio output device to the 3.5 mm, 5-pole
captive screw connector (see figure 1,
E
) for
2-channel stereo analog audio.
3. Connect a digital video display to the female
HDMI connector (see figure 1,
F
).
Configuration and Control
After the receiver and all connected devices are properly connected and powered on, the system is fully operational. To congure the receiver,
connect a host device to the front panel USB conguration port (see figure 1,
G
). On the host device, use the Extron System Conguration
Software or SIS commands in DataViewer (see the XTP R HWP 201 User Guide at www.extron.com for more information).
TIA/EIA-T568B
Pin Wire Color
1 White-orange
2 Orange
3 White-green
4 Blue
5 White-blue
6 Green
7 White-brown
8 Brown
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Pins:
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A T568B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Tx/Rx
Pins
Tx
Rx
Rx Tx
IR Device
RS-232 Device
G
G
Tx Rx
G
OVER XTP
RS-232 IR
Tx
Rx
Do not tin
the wires!
Balanced Audio Output
Tip
Ring
Tip
Ring
Slee
ves
Unbalanced Audio Output
Tip
No Ground Here
No Ground Here
Tip
Sleeves
LR
LR
68-2339-50 Rev. C
04 17
© 2017 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
  • Page 1 1
  • Page 2 2

Extron XTP R HWP 201 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues