Extron TLP Pro 525C Manuel utilisateur

Taper
Manuel utilisateur
1
TLP Pro 525C Series • Setup Guide
Overview
The Extron TLP Pro 525C is a 5-inch Cable Cubby touchpanel. It has a ip-up, 800x480 (WVGA), LCD touchscreen with
24-bit color depth. The TLP Pro 525C NC is a streamlined model, with a set of features that adhere to government and military
security protocols.
These touchpanels are suitable for any AV application requiring a Cable Cubby touchpanel with a customizable interface.
This guide provides instructions for experienced installers to mount and install these touchpanels. For more complete instructions,
see the TLPPro 525C and 725C Series User Guide at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces.
Global Configurator
®
Professional and Global Configurator Plus — For setting up and conguring the control
processor and touchpanel.
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings,
system utilities, and user management for TouchLink Pro devices.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user.
Password — The factory congured passwords for all accounts on this device have been set to the device serial
number. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password will be the default password conguration. The default
password is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Make sure you are familiar with all the included parts and have all the necessary Tools Required for Installation (see
page 4) for installing the cable cubby.
Included Parts
Check that all the following parts are included:
3/8” Hole Plug (4)1/4” Hole Plug (1)
#6-32 Screw (4)#6 Star Washer (4)
TLP Pro 525C or
TLP Pro 525C NC (1)
2-space
MAAP Frame (1)
TLP Pro 525C
Connectivity
Bracket (1)
Short Clevis Pin (1)
Cotter Pin (1)
HDMI Lockit (1)
Tie wrap (1)
5-cable Pass-through
Plate (1)
Figure 1. TLP Pro 525C Included Parts
NOTE: Active or passive MAAPs must be purchased separately (see www.extron.com).
2
TLP Pro 525C Series • Setup Guide (Continued)
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels until you have read the attention notication in the “Base Features” section of the
TLPPro 525C and 725C Series User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde de la section «Base Features » du TLPPro 525C and
725C Series User Guide.
Cut a hole in the table (see Step 1 — Verify Cut-out Dimensions on page 4 and Step 2 — Cut the Surface on
page 5).
Run cables to the cable cubby (see Step 3 — Run all Cables on page 5).
Install modules into the Cable Cubby enclosure. Multiple optional modules can be installed in the TLP Pro 525C Cable Cubby
in a variety of congurations. Decide which modules and which conguration best serve your needs. Options include:
Cable Retractors (see Step 4 — Install Cable Retractors (Optional) on page 5).
Pass-through Cable Modules (see Step 5 — Assemble the Pass-through Cable Module (Optional) on page 6).
AAP Modules (see Step 6 — Assemble the MAAP Module (Optional) on page 6).
Power Modules (see Step 7 — Install Modules on page 7).
Use the setup menu for initial conguration of the touchpanel (see Setup Menu on page 10).
Mount the units (see Step 8 — Mounting the Enclosure on page 9).
Connect the touchpanel to a Power over Ethernet (PoE) injector (see figure 13 on page 10).
Connect the power injector to the LAN and power it on (see figure 13).
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 10) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a
project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript
®
) and Global Scripter modules to get you started.
3
Front Panel Features
A
LCD screen — The TLP Pro 525C series has a 5-inch
touchscreen with a 800x480 resolution.
B
Motion sensor — Detects motion between three to ve
feet from the touchpanel, and at least 15° from the center
axis.
When no motion has been detected for a user-
dened period of time, the touchpanel enters sleep
mode.
When motion is detected by the sensor, the screen
display is restored and active.
C
Communication LED — This LED shows the
conguration and connection status of the touchpanel:
Unlit during normal operation (the touchpanel is
congured and connected to an IP Link Pro control
processor).
Blinks red if the touchpanel has been congured but
is not connected to an IP Link Pro control processor.
Permanently lit if the touchpanel has not been
congured and is not connected to an IP Link Pro
control processor.
The indicator can be toggled between enabled and
disabled, using the Setup Menu (see page 10).
D
Light sensor — This sensor monitors ambient light level
and adjusts screen brightness, based on the settings
congured using the Setup Menu.
gure 2
A
A
A
B
B
B
C
C
C
D
D
D
B
B
B
F
F
F
E
E
E
Figure 2. TLP Pro 525C Front Panel and Enclosure
Features
Enclosure Features
E
Activation switch – The left side of the lid hinge mechanism contains a switch. When the lid is closed, the switch sends the
screen into sleep mode. When the lid is opened, the screen display is restored and active.
When the lid is shut, the screen is not activated by motion near the touchpanel.
F
Speaker — A single speaker, located on the side of the enclosure, provides audible feedback for the user.
Base Panel Features
These features are accessed from underneath the touchpanel.
A
Menu button — Pressing the Menu button activates the setup
menu (see Setup Menu).
B
Reset button — Pressing the Reset button allows the unit to be
reset in any of three different modes (for an overview, see Reset
Modes: a Brief Summary on page 10).
C
Reset LED — Provides feedback about the reset status when
the user presses the Reset button (see Reset Modes: a Brief
Summary).
D
USB port — Compatible with USB 2.0.
E
LAN/PoE port — The TLP Pro 525C must be powered
through this port (see Step 9 — Connecting the Power to the
Touchpanel on page 10 for details).
gure 3
MENU
RESET
USB
275 mA
LAN / PoE
D
D
DE
E
EA
A
AB
B
BC
C
C
Figure 3. TLP Pro 525C Base Panel
ATTENTION:
Do not power on the touchpanel until you have read the attention notication in the “Base Features” section of the TLPPro
525C and 725C Series User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde de la section «Base Features » du TLPPro 525C and
725C Series User Guide.
NOTE: Once the enclosure is permanently mounted, the Menu and Reset buttons are under the table and may be difcult to
access. Use the setup menu to congure the TLP Pro 525C before mounting the unit.
4
TLP Pro 525C Series • Setup Guide (Continued)
Installation Overview
Tools Required for Installation
The installer must provide the following tools, required for installation:
Safety Glasses
Phillips Screw Driver
Tape Measure
Marking Pen
Vacuum Cleaner
Figure 4. Tools Required for Installation
Planning
Before making any cuts, select the best location for the touchpanel.
Ensure that the edge that opens on the lid is oriented correctly.
Ensure there is enough space for all the system cables and components, including cable retractors, if they are to be installed.
The space requirements for retractors are shown in the TLPPro 525C and 725C Series User Guide, which is available at
www.extron.com.
Decide on the method for cutting a hole in the table:
Hand router and template
CNC wood router
Jigsaw and paper template
Verify that you have the correct template or dimensions.
Check all relevant regulations.
Ensure that the installation complies with local, state, and national building and electrical codes.
Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.
Step 1 — Verify Cut-out Dimensions
ATTENTION:
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to
prevent scarring or damaging the furniture.
L’ouverture dans la table pour le CableCubby doit être coupée uniquement par un ouvrier détenteur d’une licence. Veillez
à ne pas laisser de marques ni à détériorer le mobilier.
Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the
furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined
(see Using a CNC wood router on the next page). Extron is not responsible for miscut mounting holes.
Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface
indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la direction dans
laquelle l’unité sera dirigée. Le côté pour accéder au connecteur est souligné. Extron décline toute responsabilité en cas
d’erreurs de coupe.
Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.
Assurez vous que la position du CableCubby et les dimensions du trou soient correctes avant de couper la table.
Ensure the table surface is at least 0.375 inch (9.5 mm) thick.
Assurez vous que la surface de la table est au moins 9,5 mm (0,375 pouce) d’épaisseur.
If using a hand router, you should purchase the appropriate Extron routing template (see “Installation Routing Templates for Cable
Cubby Series/2 Enclosures” at www.extron.com).
If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood router on the next page).
If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 525C
product page at www.extron.com).
5
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment.
ATTENTION : Risque de dommages corporels: Portez des lunettes de sécurité lorsque vous utilisez l’équipement
électrique.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying
and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table”
in the TLPPro 525C and 725C Series User Guide). There are three methods for cutting the hole in the table:
USER ACCESS
EXTRON ELECTRONICS
TLP
710CV ROUTER GUIDE - ALL MO
DELS
STANDARD
0
.625 IN OUTSIDE DIAMETER GUIDE BUSHING
0.500 IN CUT DIAME
TER STRAIGHT ROUTER BIT
METRIC
16 MM O
UTSIDE DIAMETER GUIDE BUSHING
12 MM OR 12.7 MM CUT DIAME
TER STRAIGHT ROUTER BIT
ANDA
Figure 5. Using a Hand Router
Using a hand router
Recommended method — Use the appropriate Extron routing template
(see “Installation Routing Templates” at www.extron.com). Refer to the
Routing Template User Guide, available at www.extron.com, to prepare
the template and use the template to cut the hole.
NOTE: The metal routing template must be purchased separately.
It is reusable and should not be discarded when the installation is
complete.
Using a CNC wood router
Recommended method — Use the exact cut-out dimensions:
7.50 +0.00/-0.02 inches W x 6.00 +0.00/-0.02 inches D
(191 +0.0/-0.1 mm W x 152 +0.00/-0.1 mm D)
NOTE: The underlined dimension is the connector or AAP access
side for the unit.
Using a reciprocating saw or jigsaw
Acceptable method — Use the paper cut-out template (available
under the Downloads tab on the TLPPro 525C product page at
www.extron.com).
Cut-Out Template for the Extron
TLP Pro 720C and TLP Pro 725C
1. Confirm the product to be installed.
2. Double-check the print settings,
before printing, and make sure
the page is not scaled.
3. Remove the surface cut-out area
(gray) from the template by cutting
along the red line.
DO NOT CUT the gray dotted lines.
4. Measure the cutout and template.
Make sure the dimensions are the
same as those shown.
5. Place the template and mark the
position on the mounting surface
where the RWM 2 is being installed.
6. Double ch
eck position and
dimensions, then cut the opening
in the wall.
68-2179-02 Rev. B
Trim Ring Outer Edge
(Do not cut this line.)
Page size: 11" x 17"
Print scale 1:1
Do not shrink.
User Access
User Access
R = 0.25" (6.4 mm)
7.10"
(180 mm)
8.90"
(226 mm)
+ 0.0
0" (0.00 cm)
-
0.02"
(0.05 cm)
SURFACE
CUT-OUT
AREA
Trim Ring Lip
Width = 0.325" (8.3 mm)
Trim Ring O
Trim
r Edge
r Edg
ter Ed
uter E
(Do not cut
(Do
his line.
his l
his li
this li
this l
this
)
Figure 6. Using a Reciprocating Saw or Jigsaw
Step 3 — Run all Cables
Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the
cables below the table and through the hole that was cut in Step 2 — Cut the Surface (see above). Leave enough slack in the
cables to connect or route them before the cubby is installed in the table. Leave enough space under the TLPPro 525C enclosure
for the external power supply and connection of AV cables and the network connection.
Step 4 — Install Cable Retractors (Optional)
If required, Extron cable retractors must be purchased separately. It is difcult to mount the Cable Cubby into the table after the
retractors have already been installed so Extron recommends installing the empty retractor bracket at this point. The bracket
should be secured using the lowest level of mounting holes inside the touchpanel enclosure.
A 525C module can accommodate two retractors. A triple-space module can accommodate three retractors.
The retractors should be added to the bracket after Step 8 — Mounting the Enclosure on page 9. For complete information
about retractors and how to install them, see the TLPPro 525C and 725C Series User Guide and Retractors User Guide at
www.extron.com.
6
TLP Pro 525C Series • Setup Guide (Continued)
Step 5 — Assemble the Pass-through Cable Module (Optional)
1. Insert the cable into the grommet plate (see gure 7,
1
).
Step 6 — Assemble the MAAP Module (Optional)
Figure 8 shows how to mount the double-space USB HUB4
MAAP. Mount two single-space MAAPs in a similar way.
NOTE: If required, MAAPs must be purchased separately.
Go to www.extron.com to see the full range of products
that are available.
1. Insert cables through the bottom of the connectivity
module and connect them to the MAAP (gure 8,
1
).
2. Secure two single-space or one double-space MAAPs
in the provided MAAP frame, using the provided #4-40
screws (
2
).
If you are using one single-space MAAP, ll the unused
space with a blank MAAP plate.
3. Slot the two projections of the MAAP frame into the two
outside holes at the top of the connectivity module (
3
).
4. Secure the MAAP frame to the connectivity module, using
the screw (
4
) that is provided with the MAAP frame.
To secure the MAAP module to the touchpanel enclosure, see
Step 7 — Install Modules.
e
21-918
1
2
3
Figure 7. Installing a Pass-through Cable
Module for the TLP Pro 525C
2. Pass the cables through the connectivity module from the
bottom.
3. Fill any unused holes with the provided plugs.
4. Slot the four projections of the grommet plate into the four
holes at the bottom of the connectivity module (
2
).
5. Secure the grommet plate to the connectivity module using
the screw (
3
) that is provided with the grommet plate.
Figure 7 shows the grommet plate attached to the bottom of the
connectivity module. To attach it to the top of the module, turn
over the grommet plate and insert the two outer projections into
the holes at the top of the module (see gure 8, below).
To secure the pass-through cable module to the touchpanel
enclosure, see Step 7 — Install Modules on page 7.
USB HUB4 MAAP
ACTIVITY
Mini Type
B
USB
Extron
USB HUB4 MAAP
USB Hub
(4) #4 - 40 Screws
1
1
1
2
2
2
3
3
3
4
4
4
Figure 8. Assemble the MAAP Module
7
Step 7 — Install Modules
Several types of modules can be installed in the touchpanel Cable Cubby. In addition to retractors, MAAPs, and pass-
through modules, power modules are also available. Power modules must be purchased separately. See the Extron website
(www.extron.com) to select a power module that is suitable for your location.
ATTENTION:
For units that are used in North America, only use AC power modules that are UL Listed Model “Cable Cubby AC Power
Module”.
Pour les unités qui sont utilisées en Amérique du Nord, utilisez seulement les modules d’alimentation secteur qui sont
listés UL, modèle « Cable Cubby AC Power Module ».
The unit is not UL Listed if it uses any AC power module other than Model “Cable Cubby AC Power Module”.
L’unité n’est pas certifiée UL si elle utilise tout autre module d’alimentation secteur autre que le modèle «Cable Cubby AC
Power Module ».
The holes to secure the 525C modules to the Cable Cubby are only in the longer sides of the module. Because of this, the
modules can only be installed at the ends of the enclosure. The TLP Pro 525C can also accommodate Quad modules or the larger
triple-space modules. The mounting holes for these modules allow them to be installed in the center of the enclosure.
Extron recommends either of the possible congurations shown in gure 9, although several other congurations are possible.
e e
AC Power Module + 525C Module Cable Quad Brackets (2) + 525C
Module
Figure 9. Recommended Module Configurations in the TLP Pro 525C
Installing a triple space module
Figure 10 shows how to install a power module in the
TLP Pro 525C. Quad modules and other three-space modules
are installed in a similar way.
If you are installing pass-through or AAP modules,
the modules should be assembled in advance (see
the TLPPro 525C and 725C Series User Guide at
www.extron.com).
1. Slide the module into the enclosure from underneath (
1
).
Ensure the mounting holes on the module are aligned with
the holes on the front of the enclosure.
2. Secure the module with the provided #6-32 screws and
#6 star washers (
2
).
CAUTION: Risk of electric shock: To ensure proper
electrical grounding, use the provided grounding
screws and star washers.
ATTENTION : Risque de décharge électrique: An
d’assurer une mise à la terre correcte, utilisez les
xations de mise à la terre et les rondelles en étoile
fournies.
e
21-525-01LF
21-
525-01L
F
21-526-01L
F
21-526-01LF
TOP
125V
50-60Hz 12A MAX TOTAL
~
Slide the module
into the enclosure
as shown
(either side).
1
Secur
e the module
with the included
scr
ews and washers.
2
Figure 10. Installing a Power Module in the TLP Pro 525C
8
TLP Pro 525C Series • Setup Guide (Continued)
Installing a 525C module
Figure 11 shows how to install a 525C module, with retractors,
in the TLP Pro 525C enclosure.
The 525C module accommodates up to two retractors.
It is difcult to insert the Cable Cubby into the table once
retractors are installed. Extron recommends installing the
enclosure with a empty module. Once the enclosure is in
position, the retractors can be added.
525C Modules must be installed at the ends of the enclosure
(see gure 11).
1. Slide the module into the enclosure from underneath (
1
).
Ensure the mounting holes on the module are aligned with
the holes on the sides of the enclosure.
NOTE: Multiple mounting holes in the enclosure
allow the module to be mounted at several different
levels. Ensure the module is low enough to avoid
the cable connectors coming in contact with, and
damaging the touchscreen.
2. Secure the module with the provided #6-32 screws and
#6 star washers (
2
).
3. Mount the TLP Pro 525C into the table (see Step 8 —
Mounting the Enclosure on page 9).
4. Insert the retractors into the module from underneath the
table (
3
). Ensure the mounting slot in the retractors is
aligned with the holes on the side of the module.
5. Secure the retractors with the included clevis pin (
4
).
6. Secure the clevis pin with the cotter pin.
7. Secure the locking screw on each retractor. Do not
overtighten the screw.
e
21-525-01LF
21-525-01L
F
21-526-01L
F
21-526-01LF
Insert Retractors into
the bracket.
Slide the bracket
into the enclosure
as shown
(either side).
1
3
4
Secure the bracket
with the included
scr
ews and washers.
2
Secure the Retractors
with the included
mounting pin and clip
Secur
e the locking screw
on each Retractor
.
Do not overtighten.
5
Figure 11. Installing a 525C Module in the TLP Pro 525C
9
Step 8 — Mounting the Enclosure
NOTE: Once the enclosure is permanently mounted, the Menu button is under the table and may be difcult to access. Use
the setup menu to congure the touchpanel before installing it (see Setup Menu on page 10).
1. Remove the edge grommet protecting the edges of the trim ring and the plastic lm on the nished surfaces.
ATTENTION:
Do not use isopropyl alcohol or other solvents to clean the Cable Cubby. Strong solvents will ruin some nishes.
Ne pas utiliser de l’alcool isoproprylique ou d’autres solvants pour nettoyer le CableCubby. Les solvants forts
endommageront certaines nitions.
125V
50-60Hz 12A MAX TOTAL
~
e
21-
5
25
-
01LF
21-526-0
1L
F
125V
50-60Hz 12A MAX TOTAL
~
21-526-01
21-52
5-01LF21-5
2
5-0
1LF
2
1-526-01LF
2
1-526-01LF
Rotate the side clamp
outward and ensure that
the lever is down.
Slide the clamp all the
way up against the bottom
of the table.
Ensure the Cable Cubby
is rmly seated in the table.
Raise the lever to secure
the Cable Cubby.
21 3
Lever
Figure 12. Mounting the TLP Pro 525C Enclosure
Locking
Plate
NOTE: To lower the side
clamp, turn the lever
down, then press and
hold the locking plate
while sliding down the
clamp.
2. Rotate the side clamps so that they are ush with the body of the enclosure.
3. Carefully lower the enclosure into the hole cut in the table (see Step 2 — Cut the Surface on page 5). Ensure the trimring
is ush with the top of the table.
4. Once the enclosure is in position, rotate the side clamps outward (one on each side). Ensure the lever is pointing down (see
gure 12,
1
).
5. Slide the side clamps up until they are rmly against the bottom of the table (
2
).
6. With the enclosure rmly seated, raise the levers to secure the TLP Pro 525C in place on both sides (
3
).
7. Use cable ties to secure cables under the table to prevent them becoming tangled.
10
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
For information about replacing and disposing of batteries, see the TLP Pro 525C and 725C Series User Guide at www.extron.com.
© 2019 - 2020 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
TLP Pro 525C Series • Setup Guide (Continued)
Step 9 — Connecting the Power to the Touchpanel
The TLP Pro 525C is PoE compliant and must be powered through the LAN/PoE port (see figure 3,
E
, on page 3). Extron
recommends the Extron XTP PI 100 power injector. Your power injector may look different.
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
gure 13
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo touchpanel
1
1
12
2
2
Figure 13. XTP PI 100 Power Injector
Reset Modes: a Brief Summary
These touchpanels provide the following reset modes (see the TLPPro 525C and 725C Series User Guide for complete
information):
Use Factory Firmware — With the unit powered off, press and hold the Reset button (see figure 3,
B
, on page 3) while
reapplying power to the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts arising from
uploading a rmware update.
Reset All IP Settings — Press and hold the Reset button for 6 seconds. After the Reset LED (
C
) blinks twice, release and
momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded les.
Reset to Factory Defaults — Press and hold the Reset button for 9 seconds. After the Reset LED blinks three times, release
and momentarily press the Reset button. Use this mode to return the touchpanel to factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set to the device serial number.
Passwords are case sensitive.
If the device is reset to default settings, the password will be the default password conguration. The default
password is extron (for either admin or user).
Enable or Disable the DHCP Client — This mode toggles between DHCP enabled and DHCP disabled. Press the Reset button
ve times, consecutively. After the fth press, do not press the button again within 3 seconds. If DHCP was enabled, it is now
disabled and the Reset LED blinks three times. If DHCP was disabled, it is now enabled and the Reset LED blinks six times.
Setup Menu
NOTE: Once the enclosure is permanently
mounted, the Menu and Reset buttons are under
the table and may be difcult to access. Use the
setup menu to congure the TLP Pro 525C before
mounting the unit.
Press the Menu button (figure 3,
A
, on page 3) to
open the setup menu.
Figure 14 shows the TLP Pro 525C Status screen.
Select any of the ve available screens (Status,
Network, Display, Audio, and Advanced) by pressing
the appropriate button in the navigation bar at the top
of the screen (for more information, see the TLP Pro
525C and TLP Pro 725C Series User Guide).
Status
Display Audio Advanced Exit
Network
Info
Model: TLP Pro 525C
Part Number: 60-1560-02
Firmware
Version:
1.02.0001-b001
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLP-AB-CD-EF
Display
Resolution:
GUI Project:
Sleep Timer:
800x480
N/A
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Advanced
Controller IP: N/A
Project Size: N/A
Bootloader
Version:1.03.0000
Figure 14. Setup Menu: Status Screen
ATTENTION:
Do not power on the touchpanel until you have read the Attention in the “Base
Features” section of the TLPPro 525C and 725C Series User Guide.
Ne branchez pas l’écran tactile avant d’avoir lu la mise en garde dans la
section «Base Features » du TLP Pro TLPPro 525C and 725C Series User
Guide
1. Connect the touchpanel to a PoE power injector (not provided) using a twisted
pair cable, terminated with an RJ-45 connector (see gure 13,
1
).
2. Connect the power injector to the LAN through a network switch (
2
).
68-3319-51 Rev. B
01 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Extron TLP Pro 525C Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues