SANDPIPER OWNERS MANUAL
- INSTALLATION
- COMMISSIONING OF UNIT
- MAINTENANCE
- SPECIFICATIONS
- OPERATING INSTRUCTIONS
- CUT OUT TEMPLATES
- SPARE PARTS
- WIRING DIAGRAM
- TROUBLESHOOTING GUIDE
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 2 of 22
WARRANTY OF REFRIGERATED AIRCONDITIONING
Warranty within Australia
We undertake by this warranty to rectify, free of charge, at our nearest authorised service agent, any fault due to faulty workmanship or replacement of any faulty
components within 12 months from the date of the first retail purchase thereof. This undertaking is conditional upon the appliance being installed and operated in
accordance with our instructions, and does not apply to consumable components such as filters, or to adjustments necessary due to misuse of airconditioner. Normal
user maintenance, setting of controls and transit damage are also excluded. No other person, firm or corporation is authorised by us to offer or give on our behalf any
other or greater warranty than that given by us under this warranty. The benefits conferred by this warranty are in favour of the original retail purchaser and any other
person deriving title to the goods through or under such person and are intended to be separate from the additional to all other rights and remedies which they may have
in law in respect of the goods. Warranty is void if used on commercial applications, including trucks, prime movers, locomotives & machinery.
1. In the event that warranty service is required, the purchaser must contact Aircommand Australia for service approval.
Contact information: phone +61 8 8345 8444, fax 08 8243 0628, or email sales@aircommand.com.au
2. Warranty repairs will only to be carried out by the manufacturer’s authorised service repairer.
3. It is the purchaser’s responsibility to deliver unit to the manufacturers nearest authorised Service Centre.
The manufacturer will not bear any costs involved in Service Agent’s travelling expenses or delivery charges.
Warranty outside Australia
1. Aircommand products are covered by 12 months warranty from date of first retail purchase.
2. For warranty enquiries outside Australia, please contact your national supplier.
* The warranty card must be completed and returned to the manufacturer for registration, or to the distributor in country of purchase. Online
warranty registration is available at www.aircommand.com.au/registration.html
GARANTIE FÜR KLIMAGERÄT MIT KÜHLFUNKTION
Garantie innerhalb Australiens
Wir verpflichten uns mit dieser Garantie, innerhalb von 12 Monaten ab Datum des ersten Einzelhandelskaufs, über unseren nächsten Vertragshändler jeden
durch fehlerhafte Verarbeitung entstandenen Defekt kostenlos zu beheben oder alle defekten Teile kostenlos auszutauschen. Diese Verpflichtung gilt unter
dem Vorbehalt, dass das Gerät im Einklang mit unseren Anleitungen installiert und betrieben wird, und gilt nicht für Verschleißteile wie z.B. Filter oder für
Korrekturarbeiten, die durch den Missbrauch des Klimageräts bedingt sind. Normale Wartung durch den Benutzer, die Einstellung der Bedienelemente und
Transportschäden sind ebenfalls ausgeschlossen. Wir haben keine anderen Personen, Firmen oder Unternehmen bevollmächtigt, in unserem Namen irgendeine
andere oder weiter reichende Garantie anzubieten oder zu geben als die von uns im Rahmen dieser Garantie erteilte. Die mittels dieser Garantie gewährten
Leistungen gelten zu Gunsten des ursprünglichen Einzelhandelskäufers oder jeder anderen Person, die ihren Anspruch auf die Waren durch oder von dieser Person
ableitet, und sind dazu gedacht, getrennt von allen zusätzlichen Rechten und Behelfen zu gelten, die ihnen kraft Gesetzes hinsichtlich dieser Waren zustehen.
1. Für den Fall, dass eine Garantieleistung erforderlich wird, muss sich der Käufer mit Aircommand Australia zur Genehmigung der
Leistung in Verbindung setzen. Kontaktinfo: Tel. +61 8 8345 8444, Fax: 08 8243 0628 oder E-Mail: sales@aircommand.com.au
2. Unter die Garantie fallende Reparaturen werden nur durch den Vertragsreparaturdienst des Herstellers ausgeführt.
3. Die Lieferung des Geräts an das nächstliegende Service Centre des Herstellers ist Aufgabe des Käufers.
Der Hersteller deckt keine der durch die Anfahrtskosten des Vertragsdienstes oder Lieferkosten entstandenen Ausgaben.
Garantie außerhalb Australiens
1. Für die Produkte von Aircommand gilt eine 12-monatige Garantie ab Datum des ersten Einzelhandelskaufs.
2. Für Garantieanfragen außerhalb Australiens wenden Sie sich bitte an Ihren inländischen Händler.
* Die Garantiekarte ist auszufüllen und dem Hersteller, bzw. dem Vertriebshändler im Einkaufsland, zur Registrierung zuzuschicken. Die Garantie kann online unter der
folgenden Adresse registriert werden: www.aircommand.com.au/registration.html
GARANTIE DE CLIMATISATION RÉFRIGÉRÉE
Garantie pour l’Australie
Nous nous engageons par cette garantie à faire rectifier gratuitement par notre agent de service tout défaut résultant d’un défaut de fabrication ou de remplacer tout
composant défectueux dans les 12 mois suivant la date du premier achat de l’appareil au détail. Cet engagement est conditionnel à l’installation et à l’exploitation
de l’appareil conformément à nos instructions, et ne s’applique pas aux composants consommables tels que les filtres, ou à un réglage attribuable à la mauvaise
utilisation du climatiseur. L’entretien, les réglages des commandes et les dommages en transit sont également exclus. Aucune autre personne, firme ou entreprise n’est
autorisée par nous à offrir ou à donner en notre nom toute autre garantie ou une garantie supérieure à celle donnée par nous en vertu de cette garantie. Les avantages
conférés par cette garantie reviennent à l’acquéreur au détail original ou à toute autre personne qui deviendra propriétaire de l’appareil par le biais de cette personne
ou avec son autorisation et sont censés être supplémentaires à tous les autres droits et recours dont il pourra disposer légalement en ce qui concerne l’appareil.
1. Au cas où un service de garantie serait nécessaire, l’acquéreur doit contacter Aircommand Australia pour obtenir une autorisation de service.
Cordonnées: téléphone +61 8 8345 8444, fax 08 8243 0628, ou email sales@aircommand.com.au
2. Les réparations sous garantie seront effectuées exclusivement par le réparateur autorisé du fabricant.
3. La responsabilité incombe à l’acquéreur de livrer l’appareil au Centre de service autorisé le plus proche du fabricant.
Le fabricant ne subira pas les frais de déplacement ou de livraison de l’agent de service.
Garantie en dehors de l’Australie
1. Les produits Aircommand sont couverts par une garantie de 12 mois à compter de la date du premier achat au détail.
2. Pour toute demande de renseignements en dehors de l’Australie, veuillez contacter votre fournisseur national.
* La carte de garantie doit être remplie et renvoyée au fabricant pour être enregistrée, ou au distributeur dans le pays de l’achat. Un enregistrement de garantie en ligne
est
disponible sur www.aircommand.com.au/registration.html
GARANTÍA DEL ACONDICIONADOR DE AIRE REFRIGERADO
Garantía en Australia
Nos comprometemos por medio de esta garantía a rectificar, sin cargo, en nuestra agencia de servicio autorizado, cualquier fallo causado por un componente
defectuoso dentro de los 12 meses contados a partir de la primera fecha de compra. Este compromiso es condicional a que el aparato haya sido instalado y
operado de acuerdo con nuestras instrucciones y no cubre componentes de consumo tales como filtros, o cualquier ajuste necesario debido al uso incorrecto del
acondicionador de aire. Se excluyen también las tareas de mantenimiento normales, el ajuste de los controles y cualquier daño ocurrido durante su transporte.
Ninguna otra persona, firma o corporación está autorizada a ofrecer o dar en nuestro nombre una garantía más extensa o diferente a la otorgada por esta garantía. Los
beneficios conferidos por esta garantía son a favor del comprador original y cualquier otra persona que tenga derecho al título de la mercadería a través o bajo dicha
persona y está separada de otros derechos adicionales o soluciones a las que puedan tener derecho, según la ley, respecto a las mercaderías.
1. En el caso que se necesite hacer uso del servicio de garantía, el comprador debe ponerse en contacto con Aircommand Australia para la aprobación del
servicio. Información de contacto: Teléfono: +61 8 8345 8444, fax 08 8243 0628 o Email sale[email protected]
2. Las reparaciones cubiertas por la garantía deberán ser llevadas a cabo por el servicio de reparaciones autorizado por el fabricante.
3.. La entrega de la unidad al Centro de Servicio más cercano autorizado por el fabricante es responsabilidad del comprador
El fabricante no se hará responsable de ninguno de los costes involucrados por gastos de viaje o cargos de entrega por parte del agente
proveedor del
servicio
Garantía fuera de Australia
1. Los productos de Aircommand están cubiertos por 12 meses de garantía a partir de la primera fecha de compra.
2. Por cualquier información respecto a la garantía fuera de Australia, sírvase ponerse en contacto con su proveedor nacional.
* Esta tarjeta de garantía debe ser completada y enviada al fabricante para su debida registración o alternativamente al distribuidor en el país de compra. La
registración de la garantía puede hacerse también online en: www.aircommand.com.au/registration.html
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 3 of 22
HEAD OFFICE
Aircommand
Australia Pty Ltd
954-956 Port Road
Albert Park, SA 5014
ACN 164 415 445
For warranty claims, sales
enquires or customer
service
Call:
(08) 8345 8444
Fax:
(08) 8243 0628
Email:
service@aircommand.com.au
INSTALLATION & OPERATING
INSTRUCTIONS FOR
SANDPIPER
AIRCONDITIONER
Model Number: 7000001
Serial Number: .
Date Purchased: .
WARNING
It is important that this installation manual is properly read and understood before
installation. The unit must be installed by a qualified service technician. Failure to
properly install the unit or attempting to modify it in any way can be extremely
hazardous and may result in property damage and personal injury.
Aircommand will not be held responsible for problems relating to incorrect
or improper installation methods.
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 4 of 22
GENERAL UNIT INFORMATION
I. PURPOSE
The Aircommand Sandpiper air conditioning unit was designed as a ducted unit for installation on the floor underneath a
seat/bed or inside a cupboard of a caravan or recreational vehicle (RV) to provide reverse cycle heating and cooling. It is
intended to be used to provide “spot” cooling/heating and relief to certain areas immediately adjacent to the outlets. It is not
intended to air condition all areas of the RV although it may do so in some cases. It is important that the unit is installed
properly according to the recommended guidelines.
II. ENSURING EFFECTIVE OPERATION
The effectiveness of the air conditioner is dependent on several factors that contribute to the total heat load on the van. When
an Aircommand unit is installed in a van or motorhome Aircommand assumes that the vehicle manufacturer or owner has
properly assessed the potential heat load or sought expert advice and selected the appropriate capacity air conditioning unit.
The following actions can be taken to reduce peak heat load and help the air-conditioner deliver the most comfort:
Closing all doors, hatches, windows and blinds. Extend all annexes.
Position the vehicle so that the annex will face the sun and protect the windows from direct radiation.
Turning off unneeded appliances that might increase the heat load inside the van.
Cook outside if possible.
Park the caravan/RV in a shaded position.
In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly
improve its ability to cope with the expected peak heat load.
III. CONDENSATION
In areas of high humidity, the humid air within the van will cause “sweating” or condensation in parts of the unit as the humid,
warm air contacts the colder air discharged from the system. If this occurs please ensure the following:
Close all doors, hatches, windows and blinds to limit the ingress of warm humid air.
Don’t route the ductwork near any heat producing appliances such as the rear of a refrigerator.
Avoid running the inside fan on LOW or AUTO in humid conditions. Running the fan on HIGH fan speed will result in higher
airflow and reduce the tendency to have condensation form.
Aircommand will not be held responsible for damage caused by condensation.
IV. GENERATORS
The Sandpiper is designed to run using mains power, however many owners may want to use portable generators to run the
unit when in remote locations. Any generator used should deliver high quality, pure sine wave, alternating current at 50Hz,
and be able to handle the compressor start up demand. Given the vast range in quantity and quality of generators on the
market Aircommand cannot recommend a specific model or brand. Discuss your specific requirements with the generator
supplier directly and consider their recommendations.
Aircommand will not be held responsible for damages due to the use of improper generators and such use may void your
warranty.
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 5 of 22
INSTALLATION PARTS LIST
Main components
1. Sandpiper air conditioner
2. Filter
3. Sealing mat
4. Return air grille
5. Ducting spigots
6. LCD touchscreen and remote (not shown)
7. Power cord (2m long) and separate
cable to interface
Fixtures and fittings (not shown)
8. Unit hold down screws x 6
9. Ducting outlets x 3
10. Ducting brackets x 10
11. Ducting bracket screws x 20
12. Return air grille screws x 4
13. Return air grille screw caps x 4
14. LCD touch screen screws x 2
15. Remote bracket screws x 2
Note: The ducting bracket screws, LCD touch
screen screws and the remote bracket screws
are all the same type of screw.
BEFORE INSTALLATION
Ensure that the installation instructions have been properly read and understood.
Installation must conform to local wiring regulations.
DO NOT attempt to modify or add components to the installation procedure.
This equipment must only be serviced by a licensed refrigeration mechanic.
If your installation varies from the method outlined please contact Aircommand for specialty advice.
WARNING
The unit weighs approximately 29kg, ensure a two person lift or use a mechanical hoist to avoid the risk of injury.
Failure to properly install the unit or attempting to modify it in any way can be extremely hazardous and may result in
property damage and/or personal injury.
Aircommand will not be held responsible for issues arising from incorrect or improper installation methods.
3
4
1
2
5
7
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 6 of 22
INSTALLATION
Before beginning, mark out the position of the unit based
on the following important requirements:
The Sandpiper should be placed in the centre of the RV
so that the duct lengths are as even as possible and
also near to a power socket (the power cord is 2m
long)
Consider that three holes will need to be cut through
the floor for the outside intake and exhaust air
Do not cut through the chassis or any structural
members in the floor.
The floor MUST be strong enough to support the
weight of the unit. Contact your caravan manufacturer
to confirm the max load the floor can handle
The unit must be installed so that the filter can be
easily accessed and cleaned approximately once a
fortnight. The unit should always be installed so
that it is accessible if service/repair work is required.
If these requirements are not fulfilled this may void
the warranty!
If you are not using the supplied return air grille then
the minimum area for the return air is 345cm
2
(23cmx15cm), the area can be made up of multiple
smaller areas
The total length of the ductwork should be as short as
possible and not exceed 15m, the maximum length of
one piece of ductwork is 6m
Consider placement of the LCD touch screen interface
in an appropriate location, the cable length from the
unit to the touch screen is 4m. (Extension cables are
available, contact Aircommand if needed)
The filter side of the Sandpiper should face the open
side of the seat/bed where the return air grille is
(Figure 1)
Figure 1-Preferred orientation of the unit where the filter is on
the same side and close to the return air grille
If this is not possible then there must be at least a
40mm gap between the wall/cupboard/seat and the
filter of the Sandpiper and a 60mm gap between the
top of the unit and the wall/cupboard/seat (Figure 2)
Figure 2-Minimum distances between the unit and the
surrounding walls if the filter is on the opposite side compared
to the return air grille
If the return air grille is placed low down in front of the
unit then the minimum distances to surrounding walls
are shown in Figure 3
Figure 3-Minimum spacing for a fully enclosed unit with the
return air grille on opposite sides to the filter
There must be no items placed between the
filter and the return air grille which could cause
obstructions to the air flow (see Figure 4 below)
When locating the unit consider the path/routing
locations for the ductwork. The less bends the ducting
has, the greater the performance the unit will be able
to achieve
Ensure the unit is located so that the underside intake
is not in the vicinity of water/mud spray from the
wheels
Min
40mm
Min
60mm
Min
30mm
Min
30mm
Min
60mm
Return air
grille
Airflow
Filter
Return air
grille
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 7 of 22
Figure 4-If the filter of the Sandpiper is placed on the opposite
side of the return air grille then the air passage MUST remain
unobstructed
Contact Aircommand if your installation differs significantly
from that prescribed above.
1. Cut vent holes
WARNING
There may be electrical wiring located between the floor
and inside the walls. Ensure that power is properly
disconnected at the supply (mains and/or battery). Failure
to do so may result in personal injury or death.
Floor cut-out
When positioning the unit remember that you will
need to get either a drill or long handled screwdriver
into the cupboard/bed area to secure the hold down
screws onto the floor
Mark out the holes in the floor using the template
found at the end of this manual, also mark out the
corners/edges of the unit so that the unit can be
positioned correctly
Cut out the holes in the RV floor
Do not cover the cut outs with chicken
wire/mesh or similar, doing so may void the
warranty. There are already grilles built into the
bottom of the unit.
Figure 5-Floor cut outs
Place the Sandpiper so that the edges of the unit line
up with the edges marked from the template, secure
the unit using the six hold down screws supplied
Cupboard/seat/bed cut out
Determine where the return air grille will be placed
according to the requirements above
If you are using the supplied return air grille then the
cut-out template can be found at the end of this
installation manual
Ensure the logo at the top of the return air grille is in
the correct orientation
Cut out the required hole and secure the grille in place
using the supplied screws
If you are not using the supplied return air grille then
the minimum size cut out is 345cm
2
(23cmx15cm)
2. Route and secure ducting
Don’t route the ductwork near any heat
producing appliances such as the rear of a
refrigerator as condensation will be formed. Do
not have an outlet blowing air into the return air grille as
this will ‘short circuit’ the unit.
Attach the ducting securely to the unit by
pushing/twisting the ducting onto the ducting spigots
until the teeth are engaged
Attach the longest piece of ducting to the bottom
ducting spigot
Screw the inner duct piece onto the other end of the
ducting
Figure 6-Inner duct piece shown on the left, outer duct piece
shown on the right
Route the ducting to where the outlets are desired
ensuring the bends are kept to a minimum and are as
smooth as possible. It is recommended that the
outlets are placed high up in the van and directed into
areas of common usage (bed, dining table, kitchen
etc)
The longest single piece of ducting must be less
than 6m and the overall length must be less than
15m
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 8 of 22
Cut 65mm diameter holes in the cupboard/wall where
the ducting outlets will be positioned
Then place the inner duct piece on the inner side of the
wall and screw the outer duct piece on (leaving only
the outer duct piece visible)
Attach the ducting to the walls or floor using the
ducting brackets and screws provided
For ducting running up walls Aircommand recommends
one ducting bracket per metre of ducting
Ensure that all ducting is secure on the unit and also
where the inner duct piece is attached
3. Electrical supply and interface
This unit MUST be installed in accordance with
local wiring regulations. Ensure that power is
properly disconnected at the supply (mains and/or
battery). Failure to do so may result in personal injury or
death.
Locate an existing wall socket and plug the unit in
If the supply cord is damaged, it must be
replaced by Aircommand, one of its service
agents or similarly qualified persons in order to
avoid a hazard.
With a flat head screw driver or similar pop off the rear
cover of the interface
Figure 7-Pop off the rear cover of the interface using a flat head
screwdriver or similar
Place the rear cover of the interface in position and
screw to the wall using the screws provided
Drill a 15mm hole into the wall as shown in Figure 8
Feed the cable through the 15mm hole and clip
interface onto the backing plate (Figure 9)
Figure 8-Screw the rear cover to the wall and feed cable through
Locate the interface connection cable at the rear of the
Sandpiper and connect the two cables
Figure 9-Replace the front cover of the interface
INSTALLATION IS NOW COMPLETE
PROCEED TO COMMISSIONING
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 9 of 22
COMMISSIONING OF THE UNIT
1. Turn the power on at the circuit breaker.
2. Press the ON/OFF button and set the time and
day (see operating instructions). Then press the MODE
button to select FAN .
3. Cycle through the LOW, MED and HIGH fan speeds
checking that all speeds run.
4. Set mode to COOL, adjust temperature via up/down
buttons to 4˚C below the display temp (i.e. room temp).
Note: There may be a delay of up to 3 minutes before the
compressor starts.
5. Set mode to HEAT, similarly set temperature to 4˚C
above the display temperature. Compressor will start
within three minutes. After a few minutes the fan will start
and warm air will be apparent.
Note: The fan will not begin blowing air until the inside coil
has reached a temperature of at least 30⁰C. This is to
ensure that no cold draughts are produced when the unit is
first heating up.
MAINTENANCE
I. Filter
The filter is the only part of the Sandpiper that requires
routine maintenance. It must be cleaned periodically to
ensure that it does not become clogged with dust and other
particles. The state of the filter can be ascertained from its
appearance, if it appears dirty/clogged then it should be
cleaned.
Figure 10- Filter when removed from the unit
A blocked filter will impair the cooling & heating
performance of the unit significantly.
To clean the filter, first remove it by pulling it out of the
unit using the handle on the top. Then take the filter
outside and brush it gently with a dust pan brush or similar.
WARNING
Airborne particles can pose a health risk, particularly to
young children and the elderly. Ensure that filters are
cleaned in a safe and well ventilated area
If a more thorough clean is required then the filter can be
washed out using warm soapy water. Care must be taken to
avoid ripping the fabric. The filter must be completely dry
before reinstallation.
The filter should be cleaned every two weeks or more when
in use. Prolonged use, higher concentrations of airborne
particles and various other factors may result in the filters
needing to be cleaned more often.
Replacement filters can be ordered directly from
Aircommand (part number 7001002).
II. Holding screws
Aircommand suggests that the screws attaching the unit to
the cupboard are initially checked for tightness within the
first 3 months of installation, and thereafter every 12
months if the van is in constant use.
III. Compressor mounts
Ensure that the rubber mounts on the compressor are
checked every 12 months and more often with frequent
travelling. If the top mount looks very worn or there is no
rubber left between the top washer and the compressor
foot (metal on metal contact possible) then the rubbers
need replacing.
IV. Storage
The air conditioner should be run on a routine basis to
ensure the components remain in working order.
If the van is in storage or is to remain unoccupied for an
extended length of time it is recommended that the air
conditioner is allowed to run uninterrupted for 20-30min
once every six months.
V. Warranty Claims
The unit comes with a one year manufacturer’s warranty
from date of purchase. It is IMPORTANT that you read and
understand the conditions of the warranty agreement
which are included with the unit.
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 10 of 22
If you have a claim please contact Aircommand directly on
(08) 8345 8444, alternatively you can fax (08) 8243 0628 or
email [email protected]om.au, please have your unit
serial number ready (which can be found on the sticker on
top of the unit).
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 11 of 22
GENERAL SPECIFICATIONS
Air Conditioner
Height - 287mm
Width - 442mm
Length - 652mm (692mm including hold down brackets)
Weight - 29kg
AIRCOMMAND AUSTRALIA PTY LTD
SANDPIPER
MODEL NO. 7000001
240V 50HZ
REFRIGERANT 407C 450G
RATED CAPACITY COOLING 2200W
HEATING 1800W
POWER INPUT COOLING 980 W
HEATING 880 W
RATED CURRENT COOLING 4.3A
RATED CURRENT HEATING 3.8A
MAX INPUT POWER 1150W
MAX CURRENT 5A
DESIGN SYSTEM PRESSURE
HI 2900 kPa
LOW 1840 kPa
MAX OPERATING PRESSURE 2400 kPa
AIR DELIVERY MAXIMUM 120 L/s
E&OE
All values are approximate & subject to change
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 12 of 22
OPERATING INSTRUCTIONS
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance, especially underneath
the caravan/RV where the air outlets are located. This appliance contains moving mechanical parts which
are protected by grilles but, objects of a small enough size may be able to penetrate the inside of the
appliance.
The remote control has the same features as the LCD touchscreen except for the timer function. The button icons on
the remote may vary slightly compared to the touchscreen.
LCD TOUCHSCREEN CONTROL PANEL
Decrease Fan Speed On/Off Mode Increase
DAY/TIME SETTING
Press and for 3 seconds to enter day/time setting menu
Display will show blinking for 6 seconds
Press to change the day setting
Press ” or “ ” to adjust time, press once to change the time by minutes or hold the button down to change
the time by hours
Press for 3 seconds to confirm clock setting, and return to main menu
Button Lock
Clock
Sleep
On/Off
Manual
Timer
Time
Auto fan speed
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 13 of 22
COOLING
Cycle mode button to highlight the snowflake icon .
You may select High, Med, Low or Auto fan speeds by pressing the fan button .
Now select the desired room temperature (herein referred to as the “set point”) by pressing the plus or minus
keys or , the display will flash the set point temperature. Keep pressing the button until it flashes
your desired set point. In approx. 5 seconds the display will resume reading the actual room temperature. The
compressor will have a delayed start usually 3 minutes before unit starts to cool.
Note: Any interruption to the power supply will cause the unit to delay compressor start up.
FAN ONLY
For simply recirculating air, choose the Fan mode . Choose any of the three fan speeds by pressing the fan
button . Note: Temperature button is invalid in Fan only mode.
HEAT
Cycle mode button to highlight the sun icon .
Select desired set point temperature by pressing the plus or minus keys ” or “ .
After a short delay the compressor will start. However, air will not begin to flow until it has been heated up
sufficiently; this is to prevent cold draughts.
DRY
The Dry mode is used when the room temperature is close to comfortable but you wish to dehumidify the air.
Cycle mode button to highlight the snowflake/dripping icon .
Select desired set point temperature by pressing the plus or minus keys or . Note: the fan speed is
locked in LOW.
The compressor will cycle on and off at approximate intervals of 6 minutes to extract moisture from the air.
AUTO
The Auto mode is used when Turn unit ON
Press MODE until AUTO is displayed in the Mode Display
Press FAN SPEED until the required speed is selected
Select desired set point temperature by pressing the plus or minus keys ” or “ .
Press TEMPERATURE UP / DOWN for your required set point temperature.
SLEEP
With the unit operating in cool mode, press and for 3 seconds to highlight the sleep light (moon
icon). The unit will automatically raise the set point by 1 ˚C per hour for the next three hours. Conversely in heat
mode, the set point will be lowered by 1˚C. Note: Sleep mode will automatically be cancelled in 8 hours.
TIMER (will work only when set on the LCD touchscreen, it will NOT work if set by the remote)
The timer function may be used to turn the unit either off or on at any point during the week. Note: ensure that
you have correctly set the time and day before attempting to set the timer.
Press and for 6 seconds to enter timer setting menu will display after two beeps)
--:-- will display if there is no setting
With blinking, press to change the day setting
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 14 of 22
With blinking, Press or “ to change set time
Press for 3 seconds to change between On and Off timer setting
Press for 3 seconds to cancel On/Off timer set for current day
Press “ for 6 seconds to cancel all On/Off timer that previously set
System will save all settings and returns to main menu if there is no input for 10 seconds. Note: “ ” will be
displayed when the weekly timer has been set.
BUTTON LOCK
This provides a means of locking the mode and fan settings to prevent any unintended input
Press and for 3 seconds to activate button lock, to unlock repeat the procedure
will display when button locked. Note: On/Off “ will not be affected by the button lock
TEMPERATURE DISPLAY SETTING
Press and for 5 seconds to change temperature measurement unit to either or
REMOTE CONTROL INSTRUCTIONS
The functions on the remote control are the same as on the LCD touchscreen except that the timer function can
only be set from the LCD touchscreen (see Figure 11 for diagram)
The functions operate the same way if set by the remote or the LCD touchscreen
The clock icon is used to set the time on the remote. Press once and then adjust the time using the up/down
arrows. Press the up/down arrow once to move ahead/behind by 1 minute, hold up/down arrow to move
ahead/behind by 10 minutes. Once your desired time is displayed press “SET” to save this time on the remote.
The light bulb icon will switch the backlight either on/off. To switch the backlight on/off hold the light bulb icon
for 3 seconds.
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 15 of 22
Figure 11-Remote control functions
Fan speed display
High / Medium / Low / Auto
Clock & Timer display
Real time clock
Timer ON / Timer OFF
Temperature set point display
16 °C 30 °C
Mode display
COOL / DRY / HEAT/ AUTO / FAN
Sleep function display
On / Off
Turns unit from standby to
ON and vice versa
Temperature up / down
Increase or decrease the desired
temperature set point for your
comfort.
Also acts to increase / decrease time
during timer & clock setting
Fan speed
Select from High, Medium and Low
In cooling and heating mode AUTO
FAN speed can be selected
Mode
COOL decrease air temperature
DRY dehumidify the air
HEAT increase room temperature
AUTO automatically selects heat
or cooling mode as required
FAN circulates air
Sleep
Allows the controller to gradually
depart from the set point
temperature while you sleep
Timer on & timer off
These timer buttons will not set the
timer on the actual unit.
Clock
Used to set local
time on the
remote
Set
Used to finish
clock & timer
settings
Backlight display
Turn on display back
light for 5 seconds
Send
Transmit the remotes settings
to the air conditioner
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 16 of 22
SANDPIPER FLOOR TEMPLATE
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 17 of 22
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 18 of 22
SANDPIPER SPARE PARTS
Number on diagram
Part number
Description
1
7001003
Inside fan assembly (inc. 1.5 uF capacitor)
2
7001002
Filter
3
6102092
Return air grille
4
5601069
Electronics kit (inc. touchscreen and remote)
5
7001004
Thermostat switch
6
7001006
Top foam canopy
Not shown
7001005
Outside fan assembly (inc. 3uF capacitor)
Not shown
5601071
Remote control only
Not shown
7000001
Sandpiper unit (without ducting)
Not shown
7001009
Buckles and straps (all 3 included)
7
N/A
Power cord and separate cable to interface
2
3
1
4
5
6
7
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 19 of 22
SANDPIPER WIRING DIAGRAM
Sandpiper Installation Guide 28
th
May 2013 Revision 7 Page 20 of 22
SANDPIPER TROUBLESHOOTING GUIDE
Symptom
Cause
Correction
Unit does not
operate
No power supply to unit
Check that mains power is plugged into van
and that the supply is switched ON.
Check the van’s air-conditioner power circuit
breaker is ‘ON’.
Remote control is not operating
Check the remote control screen, if blank then
replace batteries.
Stand close to unit and point remote directly
towards the IR receiver on the control pad to
test operation of remote. If there is no ‘beep’
from the air conditioner then replace batteries
and re test.
Test air conditioner operation by using the
control pad.
Fault condition indicated by
error codes on the control pad
E1 return air sensor fault
E2 inside coil sensor fault
E3 outside coil sensor fault
E4 inside coil not cooling
E5 - outside coil over temperature
E15-communication error between control pad
and main board (check connections or replace
control pad)
E18-ambient temperature sensor error
E21-outdoor air temperature sensor error
Contact Aircommand Australia for specialist
advice on fault correction and access to our
service agents.
Poor cooling or
heating
performance
Return air filter is blocked
Remove filter, clean & replace. Clean filter
every 2 weeks and more frequently with high
use.
Air outlets are closed
Ensure that at least 2 outlets are open, highest
capacity is available when all outlets are fully
open.
Return air inlet (on Sandpiper
unit) is blocked by objects or is
too close to cupboards/walls etc
Remove any objects that block air returning to
the air inlet (between the return air grille and
the return air inlet on the Sandpiper), refer to
instruction manual for details of required
distances between the inlet and surrounds.
Air outlet is directed into the
return air inlet
This will cause the unit to ‘short circuit’ and so
the compressor will cut in and out regularly.
Ensure air is directed away from the return air
inlet.
Ducting length is too long and
has too many sharp bends
The ducting should be as short and straight as
possible for optimal performance, try to
reduce lengths and sharp bends in ducting,
refer to instruction manual for recommended
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Dometic Aircommand Sandpiper Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues