Whirlpool WVW7336JS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

30" (76.2 CM) AND 36" (91.4 CM) WALL-
MOUNT CANOPY RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301
In Canada, for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.whirlpool.com or www.whirlpool.ca
HOTTE D’EXTRACTION À MONTAGE MURAL
Instructions dinstallation et Guide dutilisation et dentretien
1-800-253-1301
1-800-807-6777
or visitez notre site Web au www.whirlpool.com or www.whirlpool.ca
Table of Contents/Table des matières ..................................... 2
LIB0138948A/W11374530A
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
Y.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISA
TION RÉSIDENTIELLE UNIQUEMENT
.
2
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS .................................................4
Tools and Parts .............................................................................4
Location Requirements ................................................................4
Venting Requirements ..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ...................................................7
Prepare Location ...............................
...........................................7
Install Range Hood .......................................................................8
Connect Vent System ..................................................................8
Make Electrical Connection .........................................................9
Install Vent Covers ........................................................................9
Complete Installation ...................................................................9
RANGE HOOD USE ......................................................................10
Range Hood Controls ................................................................10
R
ANGE HOOD CARE ...................................................................10
Cleaning .....................................................................................10
WIRING DIAGRAM .......................................................................12
ASSISTANCE OR SERVICE .........................................................13
In the U.S.A. ...............................................................................13
In Canada ...................................................................................13
Accessorie
s ................................................................................13
SÉCURITÉ DE LA HOTTE ............................................................15
EXIGENCES DINSTALLATION ...................................................17
Outils et pièces ...........................................................................17
Exigences d’emplacement .........................................................17
Exigences concernant l’évacuation ...........................................19
Spécifications électriques ..........................................................20
INSTRUCTIONS D’INSTALLATION .............................................21
Préparation de l’emplacement ..................................
.................21
Installation de la hotte ................................................................22
Raccordement du conduit d’évacuation ...................................22
Raccordement électrique ...........................................................23
Installation des cache-conduits .................................................23
Terminer l’installation ..................................................................23
UTILISATION DE LA HOTTE .......................................................24
Commandes de la hotte de cuisinière .......................................24
ENTRETIEN DE LA HOTTE .........................................................24
Nettoyage ..................................................................................
.24
SCHÉMA DEBLAGE ...............................................................26
ASSISTANCE OU DÉPANNAGE ..................................................27
Aux É.-U. ....................................................................................27
Au Canada ..................................................................................27
Accessoires ................................................................................27
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
Tools Needed
Level
Drill with 1
1
/
4
" (3 cm),
3
/
8
5
/
16
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts Needed
Home power supply cable
1
/
2
" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
For Vented Installations, You Will Also Need:
1 wall or roof cap
Metal vent system
For Non-Vented (Recirculating) Installations,
Recirculation Kit. See “Assistance or Service” section to order.
6" (15.2 cm) diameter round metal vent duct -
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
Vent transition with back draft dampers installed
Vent cover support bracket
Mounting template
2-piece vent cover
2 - 3.5 x 9.5 mm screws
2 - 2.9 x 6.5 mm screws
6 - 5 x 45 mm mounting screws
2 - 8 x 40 mm wall anchors
4 - 10 x 50 mm wall anchors
T20
®
† Torx
®
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
installer's responsibility to comply with installation clearances
vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical supply is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) Installation see “For
Nonvented (recirculating) Installations Only” in “Connect Vent
System” section. Recirculation Kit . See “Assistance or Service”
section to order.
NOTE: This product will not comply with Energy Star
the optional recirculation kit.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or
latest edition, or with local codes.
Product Dimensions
* For non-vented (recirculating) installations
** For vented installations
30" (76.2 cm) or
36" (91.4 cm)
10"
(25.4 cm)
20" (50.8 cm)
®
†TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
5
Cabinet Dimensions
* For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61 cm)
fromelectriccookingsurface
Minimum distance “X”: 27" (68.6 cm)
fromgascookingsurface
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights.
Seethe following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 5" (2.26 m) 9' 2" (2.79 m)
Gas cooking
surface
7' 8" (2.34 m) 9' 2" (2.79 m)
Non-Vented (Recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 5" (2.26 m) 9' 6" (2.9 m)
Gas cooking
surface
7' 8" (2.34 m) 9' 6" (2.9 m)
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soft heights depending on the
distance “X” between the bottom of the range hood and the
cooking surface. For higher ceilings, a Stainless Steel Chimney
Extension Kit Part Number W10337357 is available from your
dealer or an authorized parts distributor. The chimney
extension replaces the upper chimney shipped with the
range hood.
Venting Requirements
(vented models only)
Vent system must terminate to the outdoors, except for
nonvented (recirculating) installations..
Do not terminate the vent system in an attic or other .
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance.
For the Most Efcient and Quiet Operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
ventbetween the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the .
range hood.
Use caulking to seal exterior wall or roof opening
aroundthecap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of
air movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof
orwall.
A 6" (15.2 cm) round vent system is needed for installation
(notincluded). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To
vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
2" (5.1 cm) min.
6" (15.2 cm) min.*
Centerline
Side
cabinet
Side
cabinet
Vent and po
wer
supply cable
entry location
Cooking surface
30" (76.2 cm) or
36" (91.4 cm)
15" (38.1 cm)
“X”
bottom of
canopy
to cooking
surface
6
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, using a Recirculation Kit (which includes charcoal
lters and a deector). To order, see the “Assistance or Service”
section.
The ducting from this fan to the outside of the building has a
strong effect on the air ow, noise and energy use of the fan.
Use the shortest, straightest duct routing possible for best
performance, and avoid installing the fan with smaller ducts than
recommended.
Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve
their rated airow.
*The recirculating version are neither Energy Star nor HVI certified.
Ensure duct joints and exterior penetrations are sealed with
caulk or other similar material to create an air-tight path and to
minimize building heat loss and gain and reduce the potential for
condensation.
Place/wrap insulation around duct and/or fan in order to
minimize possible condensation buildup within the duct, building
heat loss and gain.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum
recommendedvent length of 35 ft (10.7 m).
1 - 90° Elbow = 5 ft (1.5 m)
1 - Wall cap = 0 ft (0 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
Length of system = 13 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuitisrequired.
If the house has aluminum wiring, follow the
procedurebelow:
1. Connect a section of solid copper wire to the
pigtailleads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper connection
must conform with local codes and industry accepted wiring
practices.
Wire sizes and connections must conform with the rating of
the appliance as specied on the model/serial/rating plate.
The model/serial/rating plate is located behind the left lter
on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
Non-Vented
(Recirculating)
Wall Venting
Roof Venting
C
B
A
C
B
A
C
B
A
A. Deflector
B. 6" (15.2 cm)
round vent
C Seal duct joints
with duct tape/
caulk
A. Wall cap
B. 6" (15.2 cm)
round vent
C Seal duct joints
with duct tape/
caulk
A. Roof cap
B. 6" (15.2 cm)
round vent
C Seal duct joints
with duct tape/
caulk
90 Elbo
w
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed
beforehood is installed.
Before making cutouts, make sure there is proper
clearancewithin the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height
maximumbefore you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
nonvented.
3. Select a at surface for assembling the range hood. Place
covering over that surface.
4. Using 2 or more people, lift range hood onto
coveredsurface.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where
thecanopy hood will be installed.
2. Select a mounting height between a minimum of 24" (61.0
cm) for an electric cooking surface, a minimum of 27" (68.6
cm) for a gas cooking surface, and a suggested maximum
of 36" (91.4 cm) above the range to the bottom of the hood.
Mark a reference line on the wall.
3. Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required, or use
the (4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
Remove the template.
5. For wood, drill
3
/
16
" (4.8 mm) pilot holes at all locations
wherescrews are being installed into wood.
For wall anchors, drill
7
/
16
" (10 mm) holes at all locations
where wall anchors are being used.
6. For wood, install (2) 5 x 45 mm mounting screws. Leave
a
1
/
4
" (6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
For wall anchors, install the 10 x 60 mm wall anchors
andinstall the 5.4 x 75 mm screws into the wall anchors.
Tighten until the wall anchors are secure. Back the screws
out
1
/
4
" (6.4 mm).
Vent Cover Support Bracket Installation
Installations using telescoping upper and lower vent
coverassembly
1. Position vent cover bracket on wall about 1⁄8" (3.0 mm) away
from the ceiling.
2. Mark the hole locations.
3. Drill (2)
3
/
8
" (9.5 mm) holes for 8 x 40 mm wall anchors
andinsert anchors ush with the wall.
4. Attach vent cover support bracket to wall.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See “Venting Requirements” section.
2. Determine the required height for the home power supply
cable and drill a 1
1
/
4
" (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires
from the fused disconnect (or circuit breaker) box to make
the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Ver
tical Centerline
C
L
LLAW RAER
ETALPMET GNITNUOM
EGDE MOTTOB NGILA
ENIL LICNEP HTIW
MOTTOB GNITACIDNI
DOOH EHT FO
thgieH noitallatsnI
TROPPUS LLAW RAER RO SDUTS HGUORHT SELOH TOLIP "61/3 )OWT( 2 LLIRD
eniL latnoziroH
A
C
B
A. Centerline
B. Fastener locations
C. Mounting height reference
¹⁄₄"
(6.4 mm)
A
B
C
D
A. 8 x 40 mm wall anchors
B. Centerline on wall
C. Vent cover support bracket
D. 5 x 45 mm screws
8
Install Range Hood
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
2. Remove the grease lter. See “Range Hood Care” section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Usethe optional wall anchors if needed.
Connect Vent System
1. Install transition on top of hood (if removed for shipping)
with(2) 3.5 x 9.5 mm sheet metal screws.
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deector with the duct cover bracket with
2assembly screws provided with the Recirculation Kit.
2. Measure from the bottom of the air deector to the bottom
ofthe hood outlet.
3. Cut the duct to the measured size “X.”
4. Remove the air deector.
5. Slide the duct onto the bottom of the air deector.
6. Place the assembled air deector and duct over
theexhaustoutlet from the hood.
7. Reassemble the air deector to the duct cover bracket
withthe 2 assembly screws.
8. Seal connections with vent clamps.
A
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
A
C
B
B
A. Vent cover bracket
B. 2.9 x 6.5 mm screws
C. Deflector
X
A
C
D
B
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
9
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
aULlisted or CSA approved
1
/
2
" strain relief.
4. Run home power supply wiring through
1
/
2
" strain relief
intoterminal box.
5. Use UL listed wire connectors and connect white
wires(B)together.
6. Use UL listed wire connectors and connect black
wires(C)together.
7. Connect green (or bare) ground wire from home power
supply to the 2 yellow-green ground wires (D) in terminal
boxusing UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Install Vent Covers
1. When using both upper and lower vent covers, push lower
coverdown onto hood and lift upper cover to ceiling and
installwith (2) 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
Complete Installation
1. For non-vented (recirculating) installations only, install
charcoal lters over the grease lters, using the clips
provided in the kit. See the “Range Hood Care” section.
2. Install metal lters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light.
Seethe “Range Hood Use” section.
NOTE: To get the most efcient use from your new range
hood,read the “Range Hood Use” section.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
A UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to yellow-green wires
E. Home power supply
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
C
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
10
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the front panel on the right
side of the range hood.
Range Hood Controls
Operating the light
The On/Off light button controls both lights. Press once
Operating the blower
The Blower Speed buttons turn the blower On and control the
blower speed and sound level for quiet operation. The speed
can be changed anytime during fan operation by pressing the
desired blower speed button.
Press the Blower Off button a second time to turn the blower
OFF.
RANGE HOOD CARE
Cleaning
IMPORTANT:
before operating hood.
Exterior Surfaces:
IMPORTANT:
cleaners, Cooktop Polishing Creme, steel wool, gritty washcloths
or paper towels.
To avoid damage to the stainless steel, do not use cleaners that
contain chlorine.
Cleaning Method:
Rub in direction of grain to avoid scratching or damaging the
surface.
Stainless Steel Cleaner and Polish (not included):
See “Assistance or Service” section to order.
Liquid detergent or all-purpose cleaner: Rinse with clean
water and dry with soft, lint-free cloth.
Metal Grease Filter
1.
2.
3.
4. Push in spring release handle.
5.
6.
A
B
C
D
A. LED lamps
B. Blower and light controls
C. Grease filter handle
D. Grease filter
A
B
C
D
A. On/Off light button
B. Blower off and speed minimum button
C. Blower speed medium button
D. Blower speed maximum button
A
A. Spring release handle
11
Non-Vented (recirculating) Installation Filters
with normal use. Replace with Charcoal Filter Kit. See the
“Assistance or Service” section for information on ordering.
1.
Grease Filter” in this section.
2.
3.
4. Bend spring clips back into place to secure the
5.
Replacing a LED Lamp
To avoid damage or decreasing the life of the new lamp, do not
wearing cotton gloves to handle lamp.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Push up on the lens and turn it counterclockwise.
3. Remove and replace it with an appropriate Energy Star
GU10 base. Turn it clockwise to lock it into place.
4. Repeat steps 2-3 for the other lamps if needed.
5. Reconnect power.
NOTE: When used in recirculation mode, To Reduce the Risk of
Fire and Shock use only convertion kit Models:
- Charcoal Filter Kit W10294730
- Recirculation Kit W10349327
12
WIRING DIAGRAM
SEL0138394
BK
RD
GR
YL
BR
321456789
321456
4
3 2
L
1
RD
BK
BU
YL/GN
YL/GN
WH
BU
16 uF
BK
S40
WH
25 uF
15 uF
BK
BK
GR
RD
YL
BK
2
1
LED
Z
EMI
FILTER
N
L
GND
Blue - Red
Blue - Black
Power Supply
Frequency
Power Absorotion
120 VA C
60 Hz
144 W
WH
BU
BU
YL
YL
LED
WH
BK
WH
BK
YL/GN
YL/GN
YL/GN
MOTOR RESISTANCE (Ω)
112.1
51.6
MOTOR SPECIFICATIONS
13
ASSISTANCE OR SERVICE
If you need service
Please refer to the warranty page in this manual.
If you need replacement parts
If you need to order replacement parts, we recommend that
precision used to build every new appliance.
In the U.S.A.
Call the Whirlpool Customer eXperience Center toll-free:
1-800-253-1301 or visit our website at www.whirlpool.com.
Our consultants provide assistance with:
Scheduling of service. Whirlpool designated service
provide after-warranty service anywhere in the United States.
Referrals to local dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking,
For further assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada Customer eXperience Centre toll-free:
1-800-807-6777, or visit our website at www.whirlpool.ca.
Our Consultants Provide Assistance With:
Scheduling of Service. Whirlpool designated service
Referrals to local dealers.
Use and maintenance procedures.
Accessory and repair parts sales.
For Further Assistance
If you need further assistance, you can write to Whirlpool
Canada with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Chimney Extension Kit
Order Part Number EXTKIT18FS
Stainless Steel Cleaner and Polish
Order Part Number 31462A
Charcoal Filter Kit
(for non-vented installations only))
Order Part Number W10294730
Recirculation Kit
(for non-vented installations only)
Order Part Number W10349327
14
15
SÉCURI DE LA HOTTE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
16
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour l'extraction
de matières ou vapeurs dangereuses ou explosives.
MISE EN GARDE :
Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :
a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à semi-
conducteurs.
17
EXIGENCES D’INSTALLATION
Outils et pièces
Rassembler les outils et pièces nécessaires avant d’entreprendre
chacun des outils de la liste ci-dessous.
Outils nécessaires
Niveau
Perceuse avec forets de 1
1
/
4
" (3 cm),
3
/
8
" (9,5 mm) et
5
/
16
Crayon
Pince à dénuder ou couteau tout usage
Ruban à mesurer ou règle
Pince
Pistolet à calfeutrage et calfeutrant étanche
Brides de conduit
Scie sauteuse ou scie à guichet
Tournevis à lame plate
Cisaille de ferblantier
Tournevis à tête cruciforme
Ensemble de clés à tête hexagonale (système métrique)
Pièces nécessaires
Câble d’alimentation électrique du domicile
1 serre-câble de
1
/
2
" (12,7 mm) (homologation UL ou CSA)
Pour les installations avec décharge à l’extérieur, il vous
1 bouche de décharge (décharge à travers le mur ou à
travers le toit)
Circuit d’évacuation métallique
Pour les installations sans décharge à l’extérieur (recyclage),
Ensemble de recyclage. Voir la section “Assistance ou
service” pour commander.
Conduit d’évacuation métallique circulaire de 6" (15,2 cm)
Pièces fournies
pièces sont présentes.
Auvent de hotte avec ventilateur et lampes installés
Filtre(s) à graisse métallique
Bride de support du cache-conduit
Gabarit de montage
Cache-conduit - 2 pièces
2 vis de 3,5 x 9,5 mm
2 vis de 2,9 x 6,5 mm
6 vis de montage de 5 x 45 mm
2 chevilles d’ancrage de 8 x 40 mm
4 chevilles d’ancrage de 10 x 50 mm
Adaptateur T20
®
† Torx
®
Exigences demplacement
Observer les dispositions de tous les codes
à l’installateur qu’incombe la responsabilité de respecter les
On doit toujours installer la hotte à distance des sources de
courant d’air (fenêtres, portes et bouches de chauffage).
Respecter les dimensions indiquées pour les ouvertures à
découper dans les armoires. Ces dimensions représentent
Une source d’électricité avec liaison à la terre est nécessaire.
toit ou un mur. Pour une installation sans décharge à l’extérieur
(recyclage), voir “Installations sans décharge à l’extérieur
(recyclage) uniquement” à la section “Raccordement du
circuit d’évacuation”. Ensemble de recyclage.
Ce produit ne respecte pas les critères Energy
On doit assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou un mur traversé par l’équipement
de la hotte.
Pour une installation dans une résidence mobile
L’installation de cette hotte doit s’effectuer conformément aux
descriptions de la norme
Manufactured Home Construction Safety Standards, Title 24
Construction and Safety, title 24, HUD, Part 280) ou lorsque
cette norme n’est pas applicable, utiliser la norme Standard for
respecter les dispositions des codes locaux.
®
†TORX et T20 sont des marques déposées de Acument Intellectual Properties, LLC.
Voir la section “Assistance ou service” pour commander.
18
Dimensions du produit
* Installations sans décharge à l’extérieur (recyclage)
** Pour installations avec décharge à l’extérieur
Dimensions de l’armoire
* Installations sans décharge à l’extérieur (recyclage)
IMPORTANT:
Valeur minimale de la distance “X” : 24" (61 cm) à partir de
lasurface de cuisson électrique.
Valeur minimale de la distance “X” : 27" (68,6 cm) à partir
dela surface de cuisson au gaz.
Valeur maximale suggérée pour la distance “X” : 36"
(91,4cm)
Les cache-conduits peuvent être adaptés à différentes hauteurs
de plafond. Voir le tableau suivant.
Installations avec évacuation à l’extérieur
Hauteur minimale
sous plafond
Hauteur maximale
sous plafond
Surface de cuisson
électrique
7' 5" (2,26 m) 9' 2" (2,79 m)
Surface de cuisson
à gaz
7' 8" (2,34 m) 9' 2" (2,79 m)
Installation sans décharge à l’extérieur (recyclage)
Hauteur minimale
sous plafond
Hauteur maximale
sous plafond
Surface de cuisson
électrique
7' 5" (2,26 m) 9' 6" (2,9 m)
Surface de cuisson
à gaz
7' 8" (2,34 m) 9' 6" (2,9 m)
*REMARQUE: Les cache-conduits de hotte sont réglables ;
onpeut les ajuster en fonction de la hauteur disponible sous
plafond ou softe, selon la distance “X” entre le bas de la
hotte et l surface de cuisson. Pour des plafonds de hauteur
supérieure, unensemble d’extension de cache-conduit en acier
inoxydable, pièce numéro W10294735 peut être acheté auprès
de votre revendeur ou d’un distributeur de pièces autorisé.
L’extension decache-conduit
remplace la section de cheminée supérieure fournie hotte.
30" (76,2 cm) or
36" (91,4 cm)
10"
(25,4 cm)
20" (50,8 cm)
,
,
,
,
,
,
,
,
2" (5,1 cm) min.
6" (15,2 cm) min.*
15" (38,1 cm)
Point d'entrée
du circuit
d'évacuation
et du câble
d'alimentation
électrique
Placard
adjacent
Placard
adjacent
Axe central
Surface de cuisson
Distance “X”
entre le bas de
l'auvent et la
surface de cuisson
30" (76,2 cm) ou
36" (91,4 cm)
19
Exigences concernant l’évacuation
(modèles avec décharge à l’extérieur uniquement)
Le système de ventilation doit évacuer vers l’extérieur, sauf
pour les installations sans ventilation (recyclage).
Ne pas terminer le circuit d’évacuation dans un grenier ou
dans un autre espace clos.
Ne pas utiliser une bouche de décharge murale de 4"
(10,2cm) normalement utilisée pour un équipement de
buanderie.
Utiliser un conduit métallique uniquement. Un conduit en
métal rigide est recommandé. Il n’est pas recommandé
d’utiliser un conduit en plastique ou en métal très mince.
La longueur du circuit d’évacuation et le nombre de coudes
doivent être réduits au minimum pour des performances
optimales.
Pour un fonctionnement efcace et silencieux:
Ne pas utiliser plus de trois coudes à 90°.
Veiller à incorporer une section de conduit rectiligne d’au
moins 24" (61cm) entre deux raccords coudés adjacents.
Ne pas installer 2 coudes ensemble.
Au niveau de chaque jointure du circuit d’évacuation, assurer
l’étanchéité avec les brides de serrage.
Le circuit d’évacuation doit comporter un clapet anti-reux.
Si la bouche de décharge murale ou par le toit comporte un
clapet anti-reux, ne pas utiliser le clapet fourni avec la hotte
de cuisinière.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
La taille du conduit doit être uniforme.
Installations dans les régions au climat froid
Un clapet anti-reux additionnel devrait être installé pour
minimiser le reux d’air froid et une barrière thermique
devrait aussi être installée pour minimiser la conduction
des températures extérieures par l’intermédiaire du conduit
d’évacuation. Le clapet anti-reux doit être placé du côté air
froid de la barrière thermique.
La barrière thermique doit être aussi proche que possible de
l’entrée du circuit d’évacuation dans la partie chauffée de la
maison.
Air d’appoint
Les codes locaux en bâtiment peuvent imposer l’emploi d’un
circuit de renouvellement de l’air/introduction d’air d’appoint,
lors de l’utilisation d’un circuit d’aspiration de débit supérieur à
une valeur spéciée en pieds cubes par minute (CFM). Le débit
spécié en pieds cubes par minute varie d’une juridiction à
l’autre. Consulter un professionnel des installations de chauffage
ventilation/climatisation au sujet des exigences spéciques
applicables dans la juridiction locale.
Méthodes d’évacuation
Cette hotte est congurée à l’usine pour la décharge de l’air
aspiré à travers le toit ou à travers un mur.
Un circuit d’évacuation en conduit rond de 6" (15,2 cm) est
nécessaire pour l’installation (non fourni). La hotte comporte une
ouverture de sortie de diamètre 6" (15,2 cm).
REMARQUE: L’emploi d’un conduit exible est déconseillé.
Un conduit exible peut causer une contre-pression et
des turbulences d’air, qui réduisent considérablement la
performance.
La sortie à l’extérieur du circuit d’évacuation peut se faire à
travers le toit ou le mur. Pour la sortie à travers un mur, on doit
employer un raccord coudé à 90°.
Décharge par l’arrière
Le raccord coudé à 90° peut être installé immédiatement au-
dessus de la hotte.
Installations sans décharge à l’extérieur (recyclage)
S’il n’est pas possible d’évacuer les fumées et vapeurs de
cuisson à l’extérieur, on peut employer la version d’installation
sans décharge à l’extérieur (recyclage) de la hotte à l’aide d’un
ensemble de recyclage (comprenant des ltres à charbon et
un déecteur). Pour commander, voir la section “Assistance ou
service”.
La canalisation de ce ventilateur vers l’extérieur du bâtiment a un
effet important sur la circulation d’air, le bruit et la consommation
d’énergie du ventilateur. Un passage de conduit court et droit est
préférable pour une meilleure performance. Éviter d’installer le
ventilateur avec un conduit plus petit que recommandé.
Un isolant autour du conduit peut réduire la perte d’énergie et
inhiber la croissance de moisissures. Un ventilateur installé avec
un conduit existant peut ne pas atteindre son débit d’air
nominal.
*La version avec recirculation n’est pas certifiée Energy Star ou HVI.
Assurer le scellement des joints et des pénétrations extérieures
du conduit à l’aide du mastic ou un autre matériau similaire an
de créer un passage d’air étanche, minimiser les pertes et gains
de chaleur et réduire le risque de condensation.
Placer/enrouler de l’isolant tout autour du conduit et/ou
ventilateur an de minimiser les gains et pertes de chaleur, et la
possibilité d’accumulation de condensation dans le conduit.
Installation sans
décharge à l’extérieur
(recyclage)
Évacuation
par le mur
Évacuation à
travers le toit
C
B
A
C
B
A
C
B
A
A. Déflecteur
B. Conduit rond,
dia. 6" (15,2 cm)
C. Assurer
l’étanchéité des
jointures du
conduit avec du
ruban adhésif/
mastic pour
conduits.
A. Bouche de
décharge
murale
B. Conduit
rond, dia. 6"
(15,2 cm)
C. Assurer
l’étanchéité
des jointures
du conduit
avec du ruban
adhésif/mastic
pour conduits.
A. Bouche de
décharge sur toit
B. Conduit rond,
dia. 6" (15,2 cm)
C. Assurer
l’étanchéité des
jointures du
conduit avec du
ruban adhésif/
mastic pour
conduits.
20
Calcul de la longueur du circuit d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds
oumètres) de tous les composants utilisés dans le circuit.
Composant Conduit rond de 6" (15,2 cm)
Coude à 45° 2,5 pi (0,8 m)
Coude à 90° 5 pi (1,5 m)
La longueur équivalente maximale est de 35 pi (10,7 m).
Exemple de circuit d’évacuation
Dans l’exemple suivant, la longueur de conduit recommandée
est de 35 pi (10,7 m) maximum.
1 coude à 90° = 5 pi (1,5 m)
1 bouche de décharge murale = 0 pi (0 m)
Section droite de 8pi (2,4m) = 8 pi (2,4 m)
Longueur du circuit = 13 pi (3,9 m)
Spécications électriques
Observer les dispositions de tous les codes et règlements en
vigueur.
S’assurer que l’installation électrique est appropriée et conforme
au National Electrical Code, à la norme ANSI/NFPA70 (plus
récente édition) ou à la norme CSAC22.1-94, au Code canadien
de l’électricité, partie1 et C22.2 N°0-M91 (plus récente édition)
et à tous les codes et règlements locaux.
Si les codes le permettent et si l’on utilise un conducteur distinct
de liaison à la terre, il est recommandé qu’un électricien qualié
vérie la qualité de la liaison à la terre.
Pour obtenir un exemplaire des normes des codes ci-dessus,
contacter:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L’appareil doit être alimenté par un circuit de 120 V, CA
seulement, 60 Hz, protégé par fusible de 15 ampères.
Si le domicile possède un câblage en aluminium, suivre
laprocédure ci-dessous:
1. Raccorder une portion de câble en cuivre massif aux
conducteurs de raccordement.
2. Connecter le câblage en aluminium à la portion ajoutée
de câblage en cuivre en utilisant des connecteurs et/ou
des outils spécialement conçus et homologués UL pour
raccorder le cuivre à l’aluminium.
Suivre la procédure recommandée par le fabricant de
connecteurs électriques. Les raccordements aluminium/
cuivre doivent satisfaire aux prescriptions des codes locaux
et de l’industrie, et être conformes aux pratiques de câblage
reconnues.
Le calibre des conducteurs et les connexions doivent
être compatibles avec les caractéristiques électriques de
l’appareil spéciées sur la plaque signalétique. La plaque
signalétique de l’appareil est située derrière le ltre de
gauche, sur la paroi arrière de la hotte.
Le calibre des câbles et des raccordements doit être
conforme au National Electrical Code, ANSI/NFPA70
(édition la plus récente) ou CSA StandardsC22. 1-94,
Codecanadien des installations électriques, partie1 et
C22.2 No0-M91 (édition la plus récente) et de tous les
codes et règlements en vigueur.
Coude à 90˚
6 pi (1,8 m)
2 pi
(0,6 m)
Bouche de
décharge m
urale
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Whirlpool WVW7336JS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues