Dometic RMD10 Guide d'installation

Taper
Guide d'installation
RMD10.5
Absorber refrigerator
Installation Manual. . . . . . . . . . . . . . . . . . . . 13
Réfrigérateur à absorption
Instructions de montage . . . . . . . . . . . . . . .28
EN
FR
FOR YOUR SAFETY
If you smell gas:
1. Open window.
2. Don‘t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this manual.
For assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
REFRIGERATION
10-SERIES
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 1 Donnerstag, 28. Januar 2021 7:27 19
© 2021 Dometic Group. The visual appearance of the contents of this manual is
protected by copyright and design law. The underlying technical design and the
products contained herein may be protected by design, patent or be patent
pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
All rights are reserved.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 2 Donnerstag, 28. Januar 2021 7:27 19
RMD10
3
NOTICENOTICE
d 90°
523 mm
20.59 in.
1245 mm
49.06 in.
550 mm
21.65 in.
523 mm
20.59 in.
1245 mm
49.06 in.
605 mm
23.82 in.
RMD 10.5(S)(T)
RMD 10.5X(T)(S)
1
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 3 Donnerstag, 28. Januar 2021 7:27 19
RMD10
4
2
1
2
1250 mm
49.21 in.
< 1250 mm
< 49.21 in.
1
3
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 4 Donnerstag, 28. Januar 2021 7:27 19
RMD10
5
15 – 25 mm
0.59 in. – 0.98 in.
> 25 mm
> 0.98 in.
> 25 mm
> 0.98 in.
4
1800 mm
70.87 in.
15 – 25 mm
0.59 in. – 0.98 in.
1
5
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 5 Donnerstag, 28. Januar 2021 7:27 19
RMD10
6
300 mm
11.81 in.
1 2
6
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 6 Donnerstag, 28. Januar 2021 7:27 19
RMD10
7
A
3
1
2
B
< 5 mm (1.97 in.)
5 – 10 mm
C
1
4
(1.97 – 3.94 in.)
7
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 7 Donnerstag, 28. Januar 2021 7:27 19
RMD10
8
t 40 mm (1.57 in.)
1
2
8
3
2
1
4
9
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 8 Donnerstag, 28. Januar 2021 7:27 19
RMD10
9
0
a
1.
2.
3.
b
1
2
c
d
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 9 Donnerstag, 28. Januar 2021 7:27 19
RMD10
10
e
f
1
2
g
2
1
3
h
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 10 Donnerstag, 28. Januar 2021 7:27 19
RMD10
11
X32
X12
X13
X07
X15
X2X1
X22
X20 X17
X16
X15
X09
X30
X3
X6
2A Fuse
X4
X32
wh
(
+
)
bn
(–)
vt (bu)
S+ Optional
L
L
N
N
Interface RS232
gy (gn)
D+ (wh)
rd (+)
pk (bu) (+)
bk (–)
86
bn (–)
bn (–)
bn(–)
bn
bn
rd (+)
rd (+)
12V DC Internal
rd (+)
rd (+)
bk (-)
bk (–)
bk
bk
NTC2
ye (wh) (+)
wh (ye) (+)
wh
rd (+) rd (+)
E BAD C F
E
BA
D
C
F
NTC1
20A
rd
30
87
85
1
2
5
4
7
6
8
3
9
10
11
13
14
15
16
20
12
17
18
19
21
22 23 24
N PE L
NEMA 5
i
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 11 Donnerstag, 28. Januar 2021 7:27 19
RMD10
12
bk bn bu rd pk vt wh
EN Black Brown Blue Red Pink Violet White
FR Noir Marron Bleu Rouge Rosa Violeta Blanc
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 12 Donnerstag, 28. Januar 2021 7:27 19
RMD10 Explanation of symbols
13
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure
that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and
agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application
and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli-
cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and
others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and
warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit
dometic.com.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4 Installing the refrigerator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5 Connecting the refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1 Explanation of symbols
!
!
A
I
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 13 Donnerstag, 28. Januar 2021 7:27 19
Safety instructions RMD10
14
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and incorrect
connection voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
!
WARNING! Failure to obey these warnings could result in death
or serious injury.
Explosion hazard
Never open the absorber unit. It is under high pressure and can cause
injury if it is opened.
Only operate the device at the pressure shown on the type plate.
Only use pressure controllers with a fixed setting which comply with
the national regulations (in Europe EN 12864).
Fire hazard
Ensure clean and residue-free handling if silicon sealant or similar is
used. There is a risk of fire if silicone filaments come into contact with
hot parts or naked flames.
Never use a naked flame to check the device for leaks.
Only use propane or butane gas (not natural gas).
Health hazard
Do not operate the device if it is visibly damaged.
If the AC power cable for this device is damaged, it must be replaced
by the manufacturer, a service agent or a similarly qualified person in
order to prevent safety hazards.
This device may only be repaired by qualified personnel. Inadequate
repairs may cause serious hazards.
Risk of asphyxiation
Dismantle all device doors for the disposal of the old device and leave
the shelves in the device to prevent accidental enclosure and suffoca-
tion.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 14 Donnerstag, 28. Januar 2021 7:27 19
RMD10 Safety instructions
15
!
CAUTION! Failure to obey these cautions could result in minor or
moderate injury.
Electrical shock
Before starting the device, ensure that the power supply line and the
plug are dry.
Risk of crushing
Do not put your fingers into the hinge.
A
NOTICE! Damage hazard
Only hold the device at the body of the device during transport. Never
hold the device at the absorber unit, the cooling fins, the gas pipes,
the door or the control panel.
Make sure that the device circuit is not damaged during
transportation. The refrigerant in the device circuit is highly
flammable.
In the event of any damage to the device circuit (smell of ammonia):
Switch off the device if applicable.
Avoid naked flames and sparks.
Air the room well.
Do not install the device near naked flames or other heat sources (heat-
ers, direct sunlight, gas ovens etc.).
Danger of overheating!
Always ensure sufficient ventilation so that the heat generated during
operation can dissipate. Make sure that the device is sufficiently far
away from walls and other objects so that the air can circulate.
Check that the voltage specification on the type plate is the same as
that of the power supply.
Do not open the refrigerant circuit under any circumstances.
Only use the AC connection cable supplied to connect the device to
the AC mains.
Only use cables with a suitable size.
Never pull the plug out of the socket by the connection cable.
The device may not be exposed to rain.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 15 Donnerstag, 28. Januar 2021 7:27 19
Accessories RMD10
16
3Accessories
4 Installing the refrigerator
The device is suitable for installation in:
caravans
motor homes
The refrigerators outlined herein have been design certified by the CSA under the
current edition of ANSI Refrigerator Standard for installation in a mobile home or
recreational vehicle. The certifications are, however, contingent on the installation
being made in accordance with the following instructions as applicable.
In the USA, the installation must conform with:
National Fuel Gas Code ANSI Z223.1 – (current edition)
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280
Recreational Vehicles ANSI A119.2 – (current edition)
In Canada, the installation must conform with:
Current CSA B 149.1 Natural Gas and Propane Installation Code
Current CSA Standard Z 240.4 GAS-EQUIPPED RECREATIONAL VEHICLES
AND MOBILE-HOUSING
Any applicable local code
Description
Seal for draft-proof installation for gaps of 1 – 5 mm (0.04 – 0.2 in.) (fig. 7 B, page 7)
Seal for draft-proof installation for gaps of 5 – 10 mm (0.2 – 0.39 in.) (fig. 7 C, page 7)
Winter cover LS300 for the ventilation grill
Optional Battery Pack R10-BP for stand-alone gas operation
You find the instructions manual for changing the door lock and the
decorative plate online at:
documents.dometic.com/?object_id=63258
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 16 Donnerstag, 28. Januar 2021 7:27 19
RMD10 Installing the refrigerator
17
4.1 Preparing the installation
A
When installing the refrigerator, note the following:
To enable the refrigerant to circulate properly, the refrigerator may not exceed an
angle of 3 °.
Park the vehicle horizontally for this purpose.
The refrigerator must be installed so that
it is easily accessible for service work
easy to de-install and install
can be easily removed from the vehicle
The refrigerator must be installed in a recess so that it stands firm when the vehicle
is in motion. Note the dimensions in fig. 1, page 3
for this purpose.
The outer wall must be fitted with an air inlet vent (fig. 2 1, page 4) and an outlet
vent (fig. 2 2, page 4) with ventilation grills so that the heat generated can be
easily released to the outside:
Air inlet vent: Fit ventilation grill as flush as possible with the base of the
installation niche.
Outlet vent: fit as far above the refrigerator as possible.
The distance between the air inlet and outlet vents must be at least 1250 mm
(49.21 in.) (fig. 3, page 4).
Fit a heat conduction plate (fig. 3 1, page 4) above the refrigerator so that the
heat does not accumulate in the vehicle.
The distance between the refrigerator and the rear wall must be at least 15 mm
(0.59 in.) but no more than 25 mm (0.98 in.).
A distance of more than 25 mm (0.98 in.) between the refrigerator and rear wall
leads to poor performance and increases the power consumption of the refriger-
ator. Reduce the space behind the refrigerator to create adequate air inlet and
outlet ventilation (fig. 4, page 5). Use a ventilation plate, for example, to do
this.
NOTICE!
The refrigerator may not be installed in the rear of mobile homes with
the door pointing in the direction of travel.
Use exclusively original Dometic ventilation grills to ensure safe
operation.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 17 Donnerstag, 28. Januar 2021 7:27 19
Installing the refrigerator RMD10
18
If the minimum distance between the air inlet and outlet vents cannot be met, a
roof vent must be installed instead of the air outlet vent.
The roof vent should be installed directly above the back of the refrigerator as
far as this is possible. Use an air duct (fig. 5 1, page 5) if you need to install
the roof vent offset; otherwise, heat will accumulate there.
The distance between the air inlet vent and the roof vent must be at least
1800 mm (70.87 in.) (fig. 5, page 5).
If a roof air conditioner is provided, the distance between the roof vent
(fig. 6 1, page 6) and the air outlet of the roof air conditioner (fig. 6 2,
page 6) must be at least 300 mm (70.87 in.).
The refrigerator must not be installed at the side of the air inlet and outlet vents as
this leads to poor performance and increases the power consumption of the
refrigerator.
The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
Install the refrigerator so that it is protected from excessive heat, as this leads to
poor performance and increases the power consumption of the refrigerator.
The refrigerator must be installed in a draft-proof location.
4.2 Installing the refrigerator in a draft-proof location
!
Gas-powered refrigerators in camper vans or mobile homes must be installed in a
draft-free location. This means that the combustion air is not extracted from the inte-
rior and the exhaust fumes are prevented from directly entering the living space.
A suitable seal must be fitted between the rear panel of the refrigerator and the
interior of the vehicle.
The manufacturer recommends using a flexible seal to ease removal and installation
for maintenance purposes.
WARNING! Fire hazard!
Do not use flammable materials such as silicone sealants, foam or
similar for the draft-proof installation.
Position the device so that no connection cable is damaged or
pinched.
Do not use multiple sockets or portable power adapters behind the
device.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 18 Donnerstag, 28. Januar 2021 7:27 19
RMD10 Installing the refrigerator
19
Select one of the three versions for draft-proof installation (fig. 7, page 7):
Stop bar behind the fridge (A)
Glue a flexible sealing lip (1) to a stop bar (2) behind the refrigerator (3).
Push the refrigerator combination against the stop bar with the flexible sealing
lips.
The space behind the refrigerator is sealed to the interior of the vehicle.
Side gap distance of up to 5 mm (0.2 in.) between refrigerator and
furniture (B)
Glue the sealing lips (see chapter “Accessories” on page 16) on the side of the
furniture (4).
Push the refrigerator combination against the flexible sealing lips on furniture.
The space behind the refrigerator is sealed to the interior of the vehicle.
Side gap distance of 5 mm to 10 mm (0.39 in.) between refrigerator and
furniture (C)
Glue the double lipped sealing (see chapter “Accessories” on page 16) on the
side of the furniture (4).
Push the refrigerator combination against the double lipped sealing on furniture.
The space behind the refrigerator is sealed to the interior of the vehicle.
4.3 Making air inlet and outlet vents
I
Make an air inlet vent and an air outlet vent in the outer wall with the size of
249 mm x 490 mm (9.8 in. x 19.29 in.).
When doing so, observe the information, see chapter “Preparing the installa-
tion” on page 17.
NOTE
Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 19 Donnerstag, 28. Januar 2021 7:27 19
Installing the refrigerator RMD10
20
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
Make an air inlet vent of at least Ø 40 mm (1.57 in.) in the floor (fig. 8 1, page 8)
behind the refrigerator near the gas burner.
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8 2, page 8).
If you have to use a roof vent instead of the air outlet vent:
Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter “Preparing the installation”
on page 17.
4.4 Installing the ventilation grill
I
Seal the installation frame to make the connection waterproof (fig. 0, page 9).
Insert the installation frame and screw it down tightly (fig. a, page 9). Use all the
fixing holes for this.
Insert the ventilation grill as shown (fig. b, page 9).
NOTE
Use exclusively original Dometic ventilation grills to ensure safe
operation.
No. in
fig. 9, page 8
Description
1Slider
2 Ventilation grill
3 Installation frame
4 Fastening for condensation drain
DometicRMD10.5_INM_4445102585_AMER(en-fr)_202x-xx-xx.book Seite 20 Donnerstag, 28. Januar 2021 7:27 19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Dometic RMD10 Guide d'installation

Taper
Guide d'installation

dans d''autres langues