NuTone XN50C Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

XN50C
n
XN90C
n
XN110C
X1 | Single-Speed
Ventilation Fan
INSTALLATION GUIDE
READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at www.nutone.ca/register.asp.
Table of Contents
Warnings and Cautions 2
Typical Installation 2
New Construction Installation 3
Retrofit Installation 7
Operation 12
Cleaning and Maintenance 12
Troubleshooting 12
Service Parts 13
Warranty 13
Easy installation in both
new construction and retrofit
© 2011 Broan-NuTone LLC
XN50C
n
XN90C
n
XN110C Installation Guide
Page 2
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Use only ON/OFF switch, mechanical timer or relay-switched
control.
8. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
9. This unit must be grounded.
Typical Installation
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further
information and requirements.
45° 45°
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
ROUND
DUCT*
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
Floor
Cooking
Equipment
• Installation is the same for:
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position
between joists from 14" to 24"
on center.
Joists I-Joists Trusses
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and en-
ergy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid
installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce en-
ergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
6-inch round rigid metal duct is recommended for best performance.
XN50C
n
XN90C
n
XN110C Installation Guide
Page 3
1
2
3
4
Parts Bag holds
Knockout Plate
and six (6)
screws
Remove
Instruction
Sheet
Punch out Mask from
packaging. See Step 6.
New Construction Installation
Tools needed
Power screwdriver with a Phillips bit
Phillips screwdriver
Flathead screwdriver
• Pliers
Wire insulation stripper
Wire cutter
Materials needed
6" round metal ducting recommended for best performance.
Use of other ducting is acceptable but may impact performance.
Roof cap or wall cap (built-in damper recommended)
Tape to seal duct connections
Electrical wiring and supplies per local code requirements
1
Remove Packaging
2
Install
Mounting
Frame
XN50C
n
XN90C
n
XN110C Installation Guide
Page 4
3
1
4
2
1
2
3
New Construction Installation
3
Snap-in and
Secure Housing
4
Attach Duct Connector and Ducting
Position Housing
between joists and
crimp channel on both
sides of Mounting Frame
to lock Housing in place.
Do not crimp Housing.
Screws from Parts Bag
Top and bottom flanges
go outside Housing
Insert tab into slot
inside Housing
Screw from
Parts Bag
6" to 4" Reducer provided in select models
Tape
Tape
Tape
6" Ducting
4" Ducting
snap!
XN50C
n
XN90C
n
XN110C Installation Guide
Page 5
3
4
1
2
New Construction Installation
5
Connect Wires and Install Knockout Plate
Run 120VAC electrical wiring to the installation location.
Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
Connect wires as shown in wiring diagram.
Screw from
Parts Bag
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Connect wires
LINE
IN
GRD
WHT
BLK
GRD
WHT
BLK BLK RED
ON/OFF
SWITCH
(purchase separately)
FAN
WHT
UNITSWITCH BOX
KNOCKOUT
PLATE
RECEPTACLE
120 VAC LINE IN
SWITCH BOX
BLACK
WHITE
RED
GROUND (green or bare)
ON/OFF
SWITCH
LINE
IN
GRD
WHT
BLK
GRD
WHT
BLK BLK RED
ON/OFF
SWITCH
(purchase separately)
FAN
WHT
UNITSWITCH BOX
KNOCKOUT
PLATE
RECEPTACLE
120 VAC LINE IN
SWITCH BOX
BLACK
WHITE
RED
GROUND (green or bare)
ON/OFF
SWITCH
XN50C
n
XN90C
n
XN110C Installation Guide
Page 6
1
2
New Construction Installation
6
Insert Mask and
Finish Ceiling
7
Install Grille
See Page 12 for Operations, Cleaning and Maintenance, and Troubleshooting.
Mask protects unit
during construction.
Remove before
installing Grille.
Install ceiling material.
Cut out around Housing.
CAUTION
If the blower was unplugged, power must be
disconnected (see page 2, WARNING item 2)
before inserting motor plug into control assembly.
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
XN50C
n
XN90C
n
XN110C Installation Guide
Page 7
12" (30.5 cm)
1
2
Retrofit Installation
Parts Bag holds
Knockout Plate
and six (6)
screws
Existing ductwork and
wiring left in place
11" (27.9 cm)
parallel with joists
WARNING
Before removing existing fan, switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Examine the existing wiring to make sure it is not damaged. If any damage is found,
DO NOT CONTINUE INSTALLATION of this product. Contact a qualified person(s) for repair.
Remove
Instruction
Sheet
Punch out Mask from
packaging. See Step 12.
1
Remove Packaging
2
Switch Off Power
4
Examine Wiring
3
Enlarge Ceiling Opening and Remove Existing Fan
• Ruler
• Pencil
Drywall saw
Claw hammer or pry bar
Utility knife
Materials needed
Tape to seal duct connections
Existing rigid duct will require the
addition of a short length of flexible duct
Electrical wiring and supplies per
local code requirements
Tools needed
Power screwdriver with a Phillips bit
Phillips screwdriver
Flathead screwdriver
• Pliers
Wire insulation stripper
Wire cutter
XN50C
n
XN90C
n
XN110C Installation Guide
Page 8
2
1
2
3
4
5
1
1
2
3
3
Retrofit Installation
5
Remove Blower Assembly
6
Remove Wiring Panel
7
Insert
Mounting
Frame
Both sides
Set aside
Blower Assembly
Set aside
Wiring Panel
Set aside
screw
Bend up
four tabs
Remove screws from
Mounting Frame
and set aside
XN50C
n
XN90C
n
XN110C Installation Guide
Page 9
1
2
2
1
3
4
Retrofit Installation
Screw from
Parts Bag
Screws set
aside
in Step 7
Pull existing wiring into
Housing as it is inserted
into Mounting Frame
Pull existing
ductwork
into Housing
Insert tab into
slot inside
Housing
10
Attach Ducting and Duct Connector
8
Secure
Mounting
Frame
9
Snap-in Housing
snap!
6" to 4" Reducer provided in select models
Tape
Tape
Tape
6" Ducting
4" Ducting
XN50C
n
XN90C
n
XN110C Installation Guide
Page 10
2
1
4
5
6
3
Retrofit Installation
11
Install Knockout Plate, Connect Wires and Install Wiring Panel
Screw from
Parts Bag
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
inside of Housing and may be
oriented as
desired.
Connect
wires
Screw set
aside in
Step 6
LINE
IN
GRD
WHT
BLK
GRD
WHT
BLK BLK RED
ON/OFF
SWITCH
(purchase separately)
FAN
WHT
UNITSWITCH BOX
KNOCKOUT
PLATE
RECEPTACLE
120 VAC LINE IN
SWITCH BOX
BLACK
WHITE
RED
GROUND (green or bare)
ON/OFF
SWITCH
LINE
IN
GRD
WHT
BLK
GRD
WHT
BLK BLK RED
ON/OFF
SWITCH
(purchase separately)
FAN
WHT
UNITSWITCH BOX
KNOCKOUT
PLATE
RECEPTACLE
120 VAC LINE IN
SWITCH BOX
BLACK
WHITE
RED
GROUND (green or bare)
ON/OFF
SWITCH
Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
Connect wires as shown in wiring diagram.
XN50C
n
XN90C
n
XN110C Installation Guide
Page 11
1
2 3
1
2
Retrofit Installation
12
Insert and Secure Blower Assembly
13
Install Grille
If ceiling repairs are needed, place Mask in
Housing after Blower Assembly is secured.
See New Construction Installation Step 6.
Remove Mask before installing Grille.
Screws from Parts Bag
CAUTION
Power must be disconnected (see page 2, WARNING item 2) before inserting motor plug into control assembly.
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
XN50C
n
XN90C
n
XN110C Installation Guide
Page 12
WARNING Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
Operation
To Operate Fan
Use an ON/OFF switch to operate this ventilator.
It is normal for this ventilation fan to take approximately 5
seconds to start running after it is turned on.
Cleaning and Maintenance
To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit
with a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Control Assembly and Motor.
Troubleshooting
Symptom: The fan does not run.
Check for an open fuse or circuit breaker in the
building’s service panel.
Check that the two (2) plug-in connections for the Motor
and the Control are seated firmly in place.
Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
Check that the back draft damper in the fans Duct
Connector pivots freely. Screws used to attach the duct
to the Duct Connector may be preventing the damper
from opening.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris..
CAUTION
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
DO NOT remove motor plug to stop spinning motor.
Power must be disconnected (see WARNING at top left of
this page) before motor plug is removed or inserted into
control assembly.
XN50C
n
XN90C
n
XN110C Installation Guide
Page 13
5
10
1
3
6
7
4
8
9
11
2
Service Parts
Order replacement
parts by Part No.,
not by Key No.
Key No. Part No. Description
1 97018349 Mounting Frame
2 97018721 Knockout Plate & Screws
3 97018382 Housing
4 97018471 Wiring Panel/Harness Assembly
5 97019399 Control Assembly & Motor (XN50C)
97019397 Control Assembly & Motor (XN90C)
97018759 Control Assembly & Motor (XN110C)
6 97018331 Duct Connector - 6"
7 99111513
6" to 4" Reducer (models XN50C and XN90C only)
8 99020301 Blower Wheel
9 97018768 Scroll Assembly (XN110C)
97019371 Scroll Assembly (XN50C, XN90C)
10 97018532 Grille Assembly (includes 11)
11 99140208 Grille Spring (2 req’d)
Warranty
NuTone Ventilation Fans Limited Warranty
WARRANTY PERIOD: NuTone warrants to the original consumer purchaser of
its NuTone Ventilation Fans (the “Fan”) that your Fan will be materially free from
defects in materials or workmanship for a period of three (3) years from the
date of original purchase. This warranty does not cover accessories, such as
speed controls, that may be purchased separately and installed with the Fan.
The limited warranty period for replacement parts, and for Fans repaired or
replaced under this limited warranty, shall continue for the remainder of the
original warranty period.
NO OTHER WARRANTIES: THE FOREGOING WARRANTIES ARE
EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. NUTONE DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS
WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES
IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO
THE EXTENT THAT APPLICABLE LAW PROHIBITS THE EXCLUSION
OF IMPLIED WARRANTIES, THE DURATION OF ANY APPLICABLE
IMPLIED WARRANTY IS LIMITED TO THE PERIOD SPECIFIED FOR THE
EXPRESS WARRANTY. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you. Any oral
or written description of the Fan is for the sole purpose of identifying it and
shall not be construed as an express warranty.
REMEDY: During the applicable limited warranty period, NuTone will, at its
option, provide replacement parts for, or repair or replace, without charge,
any Fan or part thereof, to the extent NuTone finds it to be covered by and in
breach of this limited warranty. NuTone will ship the repaired or replaced Fan
or replacement parts to you at no charge. You are responsible for all costs
for removal, reinstallation and shipping, insurance or other freight charges
incurred in the shipment of the Fan or part to NuTone. This warranty does not
cover (a) normal maintenance and service, (b) normal wear and tear, (c) any
Fans or parts which have been subject to misuse, abuse, abnormal usage,
negligence, accident, improper or insufficient maintenance, storage or repair
(other than repair by NuTone), (d) damage caused by faulty installation, or
installation or use contrary to recommendations or instructions, (e) any Fan
that has been moved from its original point of installation, (f) damage caused
by environmental or natural elements, (g) damage in transit, (h) natural wear
of finish, (i) Fans in commercial or nonresidential use, or (j) damage caused
by fire, flood or other act of God. This warranty covers only Fans sold in
Canada or through Canadian distributors authorized by NuTone.
EXCLUSION OF DAMAGES: NUTONE’S OBLIGATION TO PROVIDE
REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT NUTONE’S
OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER
THIS LIMITED WARRANTY AND NUTONE’S SOLE AND EXCLUSIVE
OBLIGATION. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL,
INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT
OF OR IN CONNECTION WITH THE FAN, ITS USE OR PERFORMANCE.
Incidental damages include but are not limited to such damages as loss of
time and loss of use. Consequential damages include but are not limited to
the cost of repairing or replacing other property which was damaged if the
Fan does not work properly.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply
to you. This warranty gives you specific legal rights, and you may also have
other rights, which vary from state to state.
This warranty supersedes all prior warranties and is not transferable from the
original consumer purchaser.
NUTONE SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING
UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES,
INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES
ARISING OUT OF BREACH OF CONTRACT OR WARRANTY,
NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY,
WITH RESPECT TO THE FAN OR NUTONE’S ACTS OR OMISSIONS OR
OTHERWISE.
This warranty covers only replacement or repair of defective Fans or parts
thereof at NuTone’s main facility and does not include the cost of field service
travel and living expenses.
Any assistance NuTone provides to or procures for you outside the terms,
limitations or exclusions of this limited warranty will not constitute a waiver
of such terms, limitations or exclusions, nor will such assistance extend or
revive the warranty.
NuTone will not reimburse you for any expenses incurred by you in repairing
or replacing any defective Fan, except for those incurred with NuTones prior
written permission.
HOW TO OBTAIN WARRANTY SERVICE: To qualify for warranty service,
you must (a) notify NuTone at the address or telephone number stated below
within seven (7) days of discovering the covered defect, (b) give the model
number and part identification and (c) describe the nature of any defect in
the Fan or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9
(1-877-896-1119)
www.nutone.ca
If you must send the Fan or part to NuTone, as instructed by NuTone, you
must properly pack the Fan or part—NuTone is not responsible for damage
in transit.
XN50C
n
XN90C
n
XN110C Installation Guide
Page 14
99045100C
XN50C
n
XN90C
n
XN110C
X1 | Ventilateur monovitesse
GUIDE D’INSTALLATION
LISEZ ET CONSERVEZ CES INSTRUCTIONS
À l’attention de l’installateur: laissez ce guide chez le client.
Enregistrez votre produit en ligne sur www.nutone.ca/register.asp.
Table des matières
Avertissementset mises en garde 2
Installation type 2
Installation dans une construction neuve 3
Installation lors de modernisation 7
Fonctionnement 12
Nettoyage et entretien 12
Dépannage 12
Pièces de rechange 13
Garantie 13
Installation facile,
lors de construction
neuve ou de rénovations
XN50C
n
XN90C
n
XN110C Guide d’installation
Page 2
AVERTISSEMENT
POUR DIMINUER LE RISQUE D’INCENDIE, D’ÉLECTROCUTION OU
DE BLESSURE, RESPECTER LES PRÉCAUTIONS CI-DESSOUS:
1. N’utilisez cet appareil que de la manière prévue par son fabricant.
Si vous avez des questions, communiquez avec le fabriquant à
l’adresse ou au numéro de téléphone indiqués dans la garantie.
2. Avant toute intervention sur l’appareil ou nettoyage de celui-ci,
couper l’alimentation électrique au tableau de distribution et
verrouiller le dispositif de sectionnement pour empêcher toute
remise sous tension accidentelle. S’il est impossible de verrouiller
le dispositif de sectionnement, y fixer solidement et de manière
visible un dispositif d’affichage (par ex. : une étiquette).
3. Les travaux d’installation et de raccordement électrique doivent
obligatoirement être effectués par du personnel qualifié,
conformément aux codes et normes applicables, y compris les
codes et normes relatifs aux constructions résistantes au feu.
4. Une quantité suffisante d’air est nécessaire pour assurer la
bonne combustion et l’évacuation par la cheminée des gaz
produits par les appareils brûlant du combustible, pour éviter tout
refoulement. Respecter les recommandations du fabriquant de
l’appareil et les normes de sécurité comme celles publiées par la
National Fire Protection Association (NFPA), l’American Society
for Heating, Refrigeration and Air Conditioning Engineers et les
autorités locales responsables des codes.
5. Lorsque vous coupez un mur ou un plafond, prenez garde de ne
pas endommager les fils électriques ou autres installations qui
pourraient y être dissimulés.
6. Les ventilateurs avec conduit doivent toujours évacuer l’air
à l’extérieur.
7. N’utilisez qu’un interrupteur MARCHE/ARRÊT, une minuterie
mécanique ou une commande à relais.
8. Cet appareil convient à une installation au-dessus de la baignoire
ou de la douche lorsqu’il est relié à un circuit protégé par un
disjoncteur de fuite à la terre (DDFT).
9. Cet appareil doit obligatoirement être mis à la terre.
Installation type
ATTENTION
1. Réservé exclusivement à la ventilation générale. Ne
pas utiliser pour évacuer des matières ou des vapeurs
dangereuses ou explosives.
2. Ce produit est conçu pour être installé dans des plafonds
ayant une pente pouvant aller jusqu’à 12/12 (angle de 45°).
Le raccord de conduit doit obligatoirement être dirigé vers le
haut. NE PAS MONTER CE PRODUIT DANS UN MUR.
3. Pour éviter d’endommager les paliers du moteur et les roues
de devenir bruyantes et (ou) mal équilibrées, garder votre
appareil à l’abri des poussières de gypse, de construction, etc.
4. Consulter l’étiquette des caractéristiques sur le produit pour
plus de renseignements ou exigences.
45° 45°
L’installation est identique pour:
Convient à un plafond construit
en 2 po x 8 po.
Le ventilateur s’installe n’importe où entre
les solives, de 14 po à 24 po d’entraxe.
OU
NE PAS UTILISER DANS UNE CUISINE
Ne pas installer au-dessus ou à l’intérieur de cette zone
Plancher
Appareil
de cuisson
Solive Poutrelle Fermes
en I de toit
* Vendu séparément.
ISOLATION*
(Répartir autour
et au-dessus du boîtier
du ventilateur.)
CAPUCHON
DE TOIT*
(avec clapet
intégré)
BOÎTIER DE
VENTILATEUR
CORDON
DALIMENTATION*
CONDUIT
ROND*
COUDES
RONDS*
Calfeutrer
les espaces
autour du
ventilateur.
Sceller les joints
de conduit avec
du ruban adhésif.
Garder le
tracé des
conduits court.
CAPUCHON
MURAL*
(avec clapet intégré)
Les conduits allant de ce ventilateur jusqu’à l’extérieur de l’habitation ont une grande influence sur le débit d’air, le bruit du
ventilateur et sa consommation d’énergie. Pour obtenir le meilleur rendement, utilisez les conduits les plus courts et les
plus droits que possible et évitez d’utiliser des conduits plus petits que ceux recommandés. L’isolation des conduits peut
contribuer à réduire les pertes d’énergie et éviter la prolifération de moisissures. Les ventilateurs installés sur d’anciens
conduits pourraient ne pas produire leur débit d’air nominal.
Pour un rendement optimal, il est recommandé d’utiliser des conduits métalliques ronds de 15.2 cm (6 po) de diamètre.
XN50C
n
XN90C
n
XN110C Guide d’installation
Page 3
1
2
3
4
Le sachet de
pièces contient
une plaque de
câblage et
six (6) vis.
Découper le masque dans
l’emballage. Voir l’étape 6.
Installation dans une construction neuve
Outils nécessaires
Tournevis électrique avec embout Phillips
Tournevis Phillips
Tournevis à lame plate
• Pinces
Pince à dénuder
Pince coupante
Matériaux nécessaires
Conduit rond en métal de 6 po recommandé pour une meilleure performance.
Du conduit différent est acceptable, au prix d’une performance inférieure.
Capuchon de toit ou de mur (recommandé avec clapet intégré)
Ruban adhésif pour l’étanchéité des joints
Câblage et fournitures électriques en fonction des exigences du code local
1
Retirer l’emballage
2
Installer le cadre
de montage
Enlever la feuille
d’instructions.
XN50C
n
XN90C
n
XN110C Guide d’installation
Page 4
3
1
4
2
1
2
3
Installation dans une construction neuve
3
Encliqueter et
fixer le boîtier
4
Fixer le raccord de conduit et le conduit
Vis du sachet de pièces
Les rebords supérieur et inférieur
vont à l’extérieur du boîtier.
Introduire la languette
dans la fente à l’intérieur
du boîtier.
Vis du
sachet
de pièces
Encliqueté!
Réducteur de 6 po à 4 po
fourni avec certains modèles
Ruban
adhésif
Ruban
adhésif
Ruban
adhésif
Conduit
de 6po
Conduit
de 4po
Mettre le boîtier en place
entre les solives et
pincer la glissière de
chaque côté du cadre de
montage pour verrouiller
le boîtier en place.
Ne pas pincer le boîtier.
XN50C
n
XN90C
n
XN110C Guide d’installation
Page 5
3
4
1
2
ROUGE
INTERRUPTEUR
MARCHE/ARRÊT
(vendu séparément)
INTERRUPTEUR
MARCHE/ARRÊT
APPAREILBOÎTIER D’INTERRUPTEUR
TERRE TERRE
BLANC
NOIR
NOIR NOIR
BLANC
BLANC
LIGNE
D’ALIMENTATION
VENTILATEUR
NOIR
BLANC
ROUGE
TERRE (fil vert ou nu)
PLAQUE DE
CÂBLAGE
LIGNE D’ALIMENTATION
120V CA
BOÎTIER
D’INTERRUPTEUR
PRISE
ROUGE
INTERRUPTEUR
MARCHE/ARRÊT
(vendu séparément)
INTERRUPTEUR
MARCHE/ARRÊT
APPAREILBOÎTIER D’INTERRUPTEUR
TERRE TERRE
BLANC
NOIR
NOIR NOIR
BLANC
BLANC
LIGNE
D’ALIMENTATION
VENTILATEUR
NOIR
BLANC
ROUGE
TERRE (fil vert ou nu)
PLAQUE DE
CÂBLAGE
LIGNE D’ALIMENTATION
120V CA
BOÎTIER
D’INTERRUPTEUR
PRISE
Installation dans une construction neuve
5
Raccorder les fils et installer la plaque de câblage
Acheminer les fils 120V CA à l’emplacement de l’installation.
Raccorder les fils à la plaque de câblage fournie dans le sachet de pièces à l’aide de connecteurs homologués UL.
Raccorder les fils comme indiqué au schéma de câblage.
Vis du
sachet de
pièces
Raccorder les fils.
Fixer le collier à la plaque de
câblage. La plaque de câblage
s’installe à l’extérieur du boîtier,
d’un côté comme de l’autre.
XN50C
n
XN90C
n
XN110C Guide d’installation
Page 6
1
2
Installation dans une construction neuve
6
Mettre le masque
et finir le plafond
7
Installer la grille
Le masque protège
l’appareil pendant
les travaux . Retirer
le masque avant
d’installer la grille.
Installer le matériau du plafond.
Découper autour du boîtier.
Voir page 12 pour le fonctionnement, le nettoyage et l’entretien ainsi que pour le dépannage.
ATTENTION
Si le ventilateur a été débranché, l’alimentation
doit être coupée avant d’insérer la fiche du moteur
dans l’ensemble de commande (voir page 2,
AVERTISSEMENT point 2).
POUR ÉVITER D’ENDOMMAGER LE MOTEUR/LA
COMMANDE :
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

NuTone XN50C Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues