GAS DRYER INSTALLATION INSTRUCTIONS
CANADIAN ELECTRIC DRYER INSTRUCTIONS
INSTRUCTIONS POUR L’INSTALLATION
DE LA SÉCHEUSE À GAZ (É.-U. ET CANADA)
ÉLECTRIQUE (CANADA UNIQUEMENT)
Table of Contents
DRYER SAFETY .......................................................................... 2
INSTALLATION REQUIREMENTS .............................................. 4
Tools and Parts ...................................................................... 4
LOCATION REQUIREMENTS ..................................................... 5
ELECTRIC DRYER POWER HOOKUP-CANADA ONLY ........... 7
GAS DRYER POWER HOOKUP ................................................. 7
INSTALL LEVELING LEGS .......................................................... 9
MAKE GAS CONNECTION ....................................................... 10
VENTING .................................................................................... 10
Venting Requirements ......................................................... 10
Plan Vent System ................................................................. 11
Install Vent System .............................................................. 12
CONNECT INLET HOSE (STEAM MODEL ONLY)................... 13
CONNECT VENT ....................................................................... 14
LEVEL DRYER ........................................................................... 15
COMPLETE INSTALLATION CHECKLIST ............................... 15
DOOR REVERSAL (OPTIONAL) ............................................... 16
INSTALLATION NOTES
Date of purchase: __________________________________
Date of installation: ________________________________
Installer: _________________________________________
Model number: ____________________________________
Serial number: ____________________________________
Date d’achat: _____________________________________
Date d’installation: _________________________________
Installateur: ______________________________________
Numéro de modéle: ________________________________
Numéro de série: __________________________________
NOTES CONCERNANT L’INSTALLATION
Para una version de estas instrucciones en español, visite www.Whirlpool.com
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ................................................. 26
EXIGENCES D’INSTALLATION................................................. 28
Outillage et pièces ............................................................ 28
EXIGENCES D’EMPLACEMENT .............................................. 29
SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À
L’ALIMENTATION ÉLECTRIQUE – CANADA SEULEMENT ... 31
RACCORDEMENT D’UNE SÉCHEUSE À GAZ ....................... 31
INSTALLATION DES PIEDS DE NIVELLEMENT...................... 33
RACCORDEMENT AU GAZ ...................................................... 34
ÉVACUATION ............................................................................ 34
Exigences concernant l’évacuation ................................ 34
Planification du système d’évacuation ........................... 35
Installation du système d’évacuation .............................. 37
RACCORDEMENT DU TUYAU D’ALIMENTATION
(MODÈLE À VAPEUR UNIQUEMENT) ..................................... 37
RACCORDEMENT DU CONDUIT D’ÉVACUATION ................ 39
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... 39
ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION .......... 40
INVERSION DE LA PORTE (FACULTATIF) ............................... 40
2
DRYER SAFETY
3
4
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Level
Tape measure Pliers
Flat-blade screwdriver #2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Tin snips (new vent
installations)
Caulking gun and
compound (new vent
installations)
¼" and 5/16" nut driver
(recommended)
Leveling legs (4)
Tools needed for gas installations:
8" or 10" pipe wrench 8" or 10" adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Utility knife
“Y” connector
Parts package is located in dryer drum. Check that all parts
are included.
NOTE: Do not use leveling legs supplied with dryer if installing
with a pedestal or a stack kit.
Parts supplied (all models):
Parts supplied (steam models):
2' (0.6 m) inlet hose
Parts needed: (Not supplied with dryer)
Vent clamps
Vent elbows and vent work
Rubber washer
5
LOCATION REQUIREMENTS
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
A separate 15 or 20 amp circuit for a gas dryer or 30 amp
circuit for an electric dryer.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Cold water faucets located within 4 ft. (1.2 m) of the water
fill valves, and water pressure of 20–120 psi (138–827 kPa).
You may use the water supply for your washer using the
supplied “Y” connector and a short hose (which you will
need to purchase).
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
40°F (4°C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
27"
(686 mm)
383/4" Min.
(984 mm)
39" Max.
(990 mm)
Back view: 61/4"
(159 mm)
297/8"*
(759 mm)
31/2"*
(89 mm)
53/4"*
(146 mm)
61/8"*
(156 mm)
143/8"
(365 mm)
253/4"
(654 mm)
3/4"*
(18 mm)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”
Side view:
Front view:
* Approx. measurement
DRYER DIMENSIONS
Additional parts may be required, depending on your installation.
Check local codes. Check existing electrical supply and venting.
Read “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about
accessories available for your dryer.
Gas
* Approx. measurement
Water inlet
(Steam Models Only)
Vent
5' (1.52 m) inlet hose
Parts needed (steam models):
6
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum
spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, floor
moldings, dryer venting, and gas line.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
Mobile home installations require:
Metal exhaust system hardware, available for purchase
from your dealer. For further information, see “Assistance
or Service” section in your Use and Care Guide.
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as dryer
exhaust opening.
For mobile home installation of gas dryers:
Mobile Home Installation Hold-down Kit Part Number 346764
is available to order. For further information, see “Assistance
or Service” section in your Use and Care Guide.
*0" (0 mm) spacing is allowed for straight back venting only.
For steam models only, inlet hose must not be kinked.
Installation Clearances
For each arrangement, consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or louvered door is installed, top and bottom air openings
in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Front Sides Rear Top
Recessed NA 0" (0 mm) 0" (0 mm)** 0" (0 mm)
Closet NA 0" (0 mm) 0" (0 mm)** 0" (0 mm)
Minimum installation clearances (dryer only):
**0" (0 mm) spacing is allowed for straight back venting only.
18" min.
(457 mm)
1"*
(25 mm)
0" - 5"*
(0" - 127 mm)
24 in.2 min.
(155 cm2)
48 in.2 min.
(310 cm2)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
0"–5"*
(0 mm–127 mm)
Custom under counter installation:
7
ELECTRIC DRYER POWER HOOKUP –
CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA
International Certified Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer’s final location. 4-wire receptacle
(14-30R)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 8529008.
For further information, please reference service numbers located
in “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
8
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
GAS SUPPLY LINE
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 38" flare x 38" NPT adapter
fitting between the stainless steel gas connector and the
dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer. See illustration.
½" IPS pipe is recommended.
38" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
If you are using natural gas, do not use copper tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
If your dryer has been converted to use LP gas, 38" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON®† tape.
Must include shut-off valve.
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) ft. (1.8 m) of
the dryer. The location should be easy to reach for opening
and closing.
A. 38" flexible gas connector
B. 38" pipe to flare adapter fitting
C. 18" NPT minimum plugged tapping
D. ½" NPT gas supply line
E. Gas shut-off valve
A
B
E
D
C
GAS SUPPLY REQUIREMENTS
GAS TYPE
Natural Gas:
This dryer is equipped for use with natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced in the “Assistance or Service”
section of your Use and Care Guide.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a
qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
GAS TYPE
Natural Gas:
This dryer is equipped for use with natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced in the “Assistance or Service”
section of your Use and Care Guide.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualified
technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
9
*53/4"
(146 mm)
11/2"
(38 mm)
38" NPT dryer gas pipe
GAS SUPPLY CONNECTION REQUIREMENTS
Use an elbow and a 38" flare x 38" NPT adapter fitting
between the flexible gas connector and the dryer gas
pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON® tape.
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 2,000 ft. (610 m):
When installed above 2,000 ft. (610 m) a 4% reduction of the
burner Btu rating shown on the model/serial number plate is
required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply
piping system during pressure testing at pressures greater
than ½ psi.
DRYER GAS PIPE
The gas pipe that comes out through the rear of your dryer has
a 38" male pipe thread.
INSTALL LEVELING LEGS
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
Examine leveling legs and locate the diamond marking. Screw
legs into leg holes by hand – use a wrench to finish turning
legs until diamond marking is no longer visible.
Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
1. Prepare dryer for leveling legs
2. Screw in leveling legs
diamond
marking
* NOTE: If the dryer is mounted on a pedestal, the gas
pipe height must be an additional 10" (254 mm) or
15.5" (394 mm) from the floor, depending on the pedestal
model. For a garage installation, the gas pipe height must
be an additional 18" (460 mm) from the floor.
Diamond
marking
10
Venting Requirements
VENTING
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used
for exhausting.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
The total length should not exceed 7¾ ft. (2.4 m).
The length of flexible metal vent used must be included
in the overall vent system design as shown in the “Vent
System Charts.”
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal
or flexible metal vents. Review “Vent System Charts” and, if
necessary, modify existing vent system to achieve best drying
performance.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
A
B
1. Connect gas supply to dryer
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON® tape.
A. Flared male fitting
B. Non-flared male fitting
AB
C
D
2. Plan pipe fitting connection (option 1)
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
A. 38" flexible gas connector
B. 38" dryer gas pipe
C. 38" to 38" pipe elbow
D.
38" pipe-to-flare adapter
fitting
3. Open shut-off valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
A. Closed valve
B. Open valve
MAKE GAS CONNECTION
(gas models only)
A
B
11
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installation:
A. Dryer
B Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or
flexible metal vent
G. Vent length
necessary to
connect elbows
H. Exhaust outlet
A
B C
D
E
F
B
G
H
Optional exhaust installations:
This dryer can be converted to exhaust out the right side, left side
(all models except long vent), or through the bottom. If you prefer,
you may contact your local dealer to have the dryer converted.
A. Standard rear offset exhaust installation
B. Left- or right-side exhaust installation
C. Bottom exhaust installation
A B C
Louvered Hood
Angled Hood
Box Hood
Exhaust hoods:
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Do not use an exhaust hood with a magnetic latch.
Elbows:
Recommended Styles:
45° elbows provide better airflow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Good Better
Acceptable Style:
12
Install Vent System
1. Install exhaust hood
12" min.
(305 mm)
12" min.
(305 mm)
2. Connect vent to exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
The “Vent System Charts” provide venting requirements
that will help achieve best drying performance.
To determine if your model has a long vent system, refer
to the type code located on the serial number plate in the
inner door well. Example: An electric model would be DALV
– ELE – XXXXXXX-XXX. A gas model would be DALV – GAS –
XXXXXXX-XXX.
NOTE: For long vent systems, use of box/louvered hoods will
improve venting regardless of length.
Standard Vent System Chart
Number of
90° elbows Type
of vent Angled
hoods
0Rigid metal 64 ft. (20 m)
1Rigid metal 54 ft. (16.5 m)
2Rigid metal 44 ft. (13.4 m)
3Rigid metal 35 ft. (10.7 m)
4Rigid metal 27 ft. (8.2 m)
Long Vent System Chart
Number of
90° elbows Type
of vent Angled
hoods
0Rigid metal 160 ft. (48.8 m)
1Rigid metal 150 ft. (45.7 m)
2Rigid metal 140 ft. (42.7 m)
3Rigid metal 130 ft. (39.6 m)
4Rigid metal 120 ft. (36.6 m)
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use the “Vent System Charts” on the next page to determine
type of vent material and hood combinations acceptable
to use.
NOTE: Do not use vent runs longer than those specified
in “Vent System Charts.”
Exhaust systems longer than those specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
13
CONNECT INLET HOSE
(STEAM MODEL ONLY)
For non-steam models, skip to “Connect Vent.”
The dryer must be connected to the cold water faucet using
the new inlet hoses (not supplied). Do not use old hoses.
NOTE: Replace inlet hoses after 5 years of use to reduce the
risk of hose failure. Record hose installation or replacement
dates on the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
1. Turn cold water off, remove hose,
and replace rubber washer
Turn cold water faucet off and remove washer inlet hose.
Remove old rubber washer from inlet hose and replace with
new rubber washer.
2. Attach short hose and “Y” connector
Attach 2 ft (0.6 m) inlet hose to cold water faucet. Screw on
coupling by hand until it is seated on faucet. Then attach “Y”
connector to male end of the 2 ft (0.6 m) inlet hose. Screw on
coupling by hand until it is seated on connector.
3. Tighten couplings
Using pliers, tighten the couplings with additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
4. Attach long hose to “Y”
connector and tighten couplings
Attach one of the 5 ft (1.5 m) inlet hose ends to the “Y”
connector. Attach washer cold inlet hose to other side of
“Y” connector. Screw on coupling by hand until it is seated
on connector. Using pliers, tighten the couplings an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
14
CONNECT VENT
1. Connect vent to exhaust outlet
2. Move dryer to final location
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
Move dryer to final location, taking care not to crush or
kink vent or flexible gas line.
After dryer is in place, remove corner posts and cardboard
from under dryer.
5. Attach long hose to dryer fill valve
and tighten coupling
Remove protective cap from
water inlet valve. Attach other end
of long hose to fill valve at bottom of dryer
back panel. Screw on coupling by hand until it is seated on
fill valve connector. Using pliers, tighten the couplings an
additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling
can result.
6. Turn on cold water faucet
Check that the water faucets are turned on.
7. Check for leaks
Check for leaks around “Y” connector, faucet, and hoses.
15
2. Adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench
to adjust legs up or down, and check again for levelness.
Once dryer is level, make sure all four legs are snug against
the floor and the dryer does not rock.
LEVEL DRYER
1. Level dryer
Place
level here
Not Level LEVEL Not Level
Check levelness of dryer from
side to side. Repeat from front to back.
NOTE: The dryer must be level for the moisture sensing
system to operate correctly.
COMPLETE INSTALLATION
CHECKLIST
q Check that all parts are now installed. If there is an extra
part, go back through steps to see what was skipped.
q Check that you have all of your tools.
q Dispose of/recycle all packaging materials.
q Be sure the water faucets are on.
q Check for leaks around “Y” connector, faucet, and hoses.
q Check dryer’s final location. Be sure vent is not crushed
or kinked.
q Check that dryer is level. See “Level Dryer.”
q Remove film on console and any tape remaining on dryer.
q Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
q Read “Dryer Use” in your Use and Care Guide.
q If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the
water system in the dryer. Over time, the buildup of lime
scale may clog different parts of the water system, which
will reduce product performance. Excessive scale buildup
may lead to the need for certain part replacement or repair.
Electric Models
q Plug into a grounded outlet.
Gas Models
q Plug into a grounded outlet.
q Check that gas supply is on.
q Check for leaks.
q Check to be sure that the flexible gas line is not crushed
or kinked.
All Models:
q Select a Timed Dry heated cycle, and start dryer. Do not
select Air Only Temperature setting.
If dryer will not start, check the following:
• Start button has been pressed firmly.
• Dryer is plugged into an outlet and/or electrical supply
is connected.
• Household fuse is intact and tight, or circuit breaker
has not tripped.
• Dryer door is closed.
This dryer automatically runs an installation diagnostic routine
at the start of its first cycle.
NOTE: You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor
will go away.
16
2. Move the door strike
Using a T25® screwdriver, remove the 2 screws securing the
door strike to the door frame of the dryer. Rotate the strike
180° and attach to the opposite side of dryer door frame
as shown.
3.
Remove inner door from outer door
Position the door with the inside of the door facing up.
Using a Phillips screwdriver, remove the 10 screws securing
the inner door to the outer door. Lift off the inner door and
set aside.
†† ® TORX and T25 are registered trademarks of Acument Intellectual Properties, LLC.
DOOR REVERSAL (OPTIONAL)
The following instructions are for models with a round and
square-shaped doors.
#2 Phillips screwdriver
Min. 8" long TORX T25® ††
screwdriver
Tools needed:
1. Remove door from dryer
IMPORTANT: If the protective film has not yet been
removed from the dryer, peel the film from the dryer
door before proceeding.
Using a T25® screwdriver, remove the 4 screws securing the
door hinge to the dryer and lift up and out to remove the door.
Place the door on a soft towel or other non-scratch surface.
Reinstall the 4 screws in the holes.
Reverse door swing round-shaped door flat glass –
single handle
17
5. Reverse outer window assembly
Using a Phillips screwdriver, remove the 4 screws from the
outer window retainer and lift off the trim ring off the window
(A). Rotate trim ring 180° and secure with the 4 screws
removed earlier (B).
Using a Phillips screwdriver, remove the 2 screws from the
outer window retainer and rotate the outer window assembly
clockwise until the square notches line up with the 4 tabs
on the trim ring indicated with arrows in the figure A above.
Then lift out the outer window and retainer up and off the trim
ring and set aside (B).
Handle
Fig. A
Fig. B
Handle
4. Remove outer window assembly
from trim ring
Fig. A
Fig. B
18
8. Reinstall hinge and latch on
opposite sides
Using a T25® screwdriver, reinstall the latch plate, latch
backing plate, and hinge assembly on the opposite sides
from which they were removed.
7. Remove hinge and latch
Using a T25® screwdriver, remove the 3 screws securing
the latch plate and latch backing plate and the 5 screws
holding the hinge assembly in place.
Hinge
Latch
6. Rotate and reassemble outer window
assembly to trim ring
With the edge with 2 notches at the top, align the notches
on the outer window assembly with the tabs on the trim
ring and lower into place as shown in figure A. Rotate the
outer window assembly counterclockwise to lock tabs into
place (B). Using a Phillips screwdriver, secure with 2 screws
removed earlier.
IMPORTANT: Do not overtighten.
Fig. A
Fig. B
Bottom
of door
Notches
19
9. Reinstall inner door assembly
Position the door with the inside of the door facing up.
Reinstall the 10 screws securing the inner door to the
outer door.
10. Reinstall door on dryer
Using a T25® screwdriver, remove the 4 screws on the dryer.
Insert the tabs on the hinge into the mounting slot and slide
down to engage the top tab. Secure in place with the
4 T25® screws removed earlier.
Bottom
of door
20
1. Remove door from dryer
IMPORTANT: If the protective film has not yet been
removed from the dryer, peel the film from the dryer
door before proceeding.
Using a T25® screwdriver, remove the 4 screws securing the
door hinge to the dryer and lift up and out to remove the door.
Place the door on a soft towel or other non-scratch surface.
Reinstall the 4 screws in the holes.
Reverse door swing round-shaped door flat glass – double handle
2. Move the door strike
Using a T25® screwdriver, remove the 2 screws securing the
door strike to the door frame of the dryer. Rotate the strike
180° and attach to the opposite side of dryer door frame,
as shown.
3.
Remove inner door from outer door
Position the door with the inside of the door facing up.
Using a Phillips screwdriver, remove the 10 screws securing
the inner door to the outer door. Lift off the inner door and
set aside.
4. Remove hinge and latch
Using a T25® screwdriver, remove the 3 screws securing the
latch plate and latch backing plate and the 5 screws holding
the hinge assembly in place.
Hinge
Latch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Whirlpool WGD7540FW Guide d'installation

Taper
Guide d'installation