4
aboUt tHe Heat PUmP
that will heat and cool your building year round and provide
energy saving comfort. It’s an unknown fact that heat is always
in the air, even when the outside temperature is below freezing.
saving heat during the winter months.
In colder temperatures, the heat pump performs like an air
building is absorbed by the refrigerant and exhausted inside.
the heat, as is the case with more traditional furnace designs.
During summer, the heat pump reverses the flow of the heat-
absorbing refrigerant to become an energy-efficient, central air
conditioner. Excess heat energy inside the home is absorbed
by the refrigerant and exhausted outside the building.
oPerating inStrUctionS
an inside wall and not on an outside wall or other location where
its operation may be adversely affected by radiant heat from
fireplaces, sunlight, or lighting fixtures, and convective heat from
warm air registers or electrical appliances.
note: If the temperature level is re-adjusted, or the system
mode is reset, the fan and compressor in the outdoor unit
following a previous operation or the interruption of the main
electrical power.
CoolingOperation(1or2StageOperation)
2. Set the thermostat temperature selector to the desired
indoor blower will all cycle on and off to maintain the indoor
temperature at the desired cooling level.
note: If Stage 1 cool does not satisfy the thermostat demand,
blower will ramp to high speed.
HeatingOperation-HeatPumpMode
2. Set the temperature selector to the desired temperature level.
on and off to maintain the indoor temperature at the desired
heating level.
noteS:
If Stage 1 heat does not satisfy the thermostat demand, stage
blower will ramp to high speed.
space is not met in a normal period of time or the difference
between the thermostat set point and room temperature is
large, the heat pump will automatically shut off and the gas
heat will operate until the thermostat demand for heat is met.
EmergencyHeat-GasHeatmode
etc., the compressor and outdoor fan will be locked off and the
gas furnace will be used as a source of heat. Sustained use of
gas heat in place of the heat pump will result in an increase in
DefrostOperation
During cold weather heating operation, the outdoor unit will
develop a coating of snow and ice on the heat transfer coil.
Demand Defrost that monitors ambient and coil temperatures
to regulate the defrost function accordingly.
the compressor will turn on and begin to heat the outdoor coil
causing the ice and snow to melt.
During the defrost period, the gas funace will energize and
produce warm air to offset the heat pump operation while in its
reverse cycle. Initially the air out of the supply registers may
be slightly cooler since the heat pump has reversed its cycle
and is now in the cooling mode to aide in the defrosting of the
continues to operate and the blower speed increases.
note:
rise from the outdoor unit as the warm coil causes the melting
fan motor will start, and the compressor will turn off again. In
the end of the defrost cycle.
AutomaticHeatPumpOperation(Cooling&Heating)
2. Set the thermostat’s temperature selector to the desired
the indoor blower will then cycle on and off in either the heating
or cooling mode of operation as required to automatically
maintain the indoor temperature within the desired limits.
ContinuousIndoorBlowerOperation
circulate the indoor air to equalize a temperature imbalance
due to a solar load, cooking, or fireplace operation.
Set
blower will start immediately and will run continually until the fan
note:
Continuous indoor blower
operation can be obtained with the thermostat system switch
SystemShutdown
note:
regardless of the thermostat temperature selector’s setting.
DUal FUel UnitS - gaS Heat / electric Heat PUmP