Maytag MDG20PDAGW Installation Instructions Manual

Catégorie
Sèche-linge électriques
Taper
Installation Instructions Manual
www.maytagcommerciallaundry.com
W10868681B
INSTALLATION INSTRUCTIONS
Original instructiOns
cOmmercial gas Or electric Dryer
mODels
mDe20PDagW, mDe20PnagW, mDe20mnagW, mDe20csagW,
mDg20PDagW, mDg20PnagW, mDg20mnagW, anD mDg20csagW
INSTRUCTIONS D’INSTALLATION
instructiOns DOrigine
sèche-linge À gaz Ou Électrique À usage cOmmercial
mODèles
mDe20PDagW, mDe20PnagW, mDe20mnagW, mDe20csagW,
mDg20PDagW, mDg20PnagW, mDg20mnagW, anD mDg20csagW
INSTRUCCIONES DE INSTALACIÓN
instrucciOnes Originales
secaDOra a gas O ectrica cOmerciale
mODelOs
mDe20PDagW, mDe20PnagW, mDe20mnagW, mDe20csagW,
mDg20PDagW, mDg20PnagW, mDg20mnagW, anD mDg20csagW
ISTRUZIONI D’INSTALLAZIONE
istruziOni Originali
asciugatrice a gas O elettrica cOmmerciale
mODelli
mDe20PDagW, mDe20PnagW, mDe20mnagW, mDe20csagW,
mDg20PDagW, mDg20PnagW, mDg20mnagW, anD mDg20csagW
2
TABLE OF CONTENTS
DRYER SAFETY ................................................................................ 3
FOR THE OWNER
MAINTENANCE INSTRUCTIONS ..................................................6
IF YOU NEED ASSISTANCE .........................................................6
FOR WHIRLPOOL AUTHORIZED SERVICE PERSON
TOOLS & PARTS ..............................................................................7
SPECIFICATIONS ............................................................................ 7
DIMENSIONS/CLEARANCES .................................................... 8
DRYER INSTALLATION REQUIREMENTS ............................... 9
INSTALLING LEVELING LEGS AND COIN BOX ..................... 10
LEVELING ........................................................................................ 11
ELECTRIC DRYER INSTALLATION REQUIREMENTS ........ 12
GAS DRYER INSTALLATION REQUIREMENTS ................... 13
DRYER VENTING REQUIREMENTS ....................................... 15
GAS SUPPLY CONNECTION .................................................... 17
TECHNICAL SPECIFICATIONS–GAS DRYER ....................... 18
COMPLETE INSTALLATION ....................................................... 20
REVERSING DRYER DOOR SWING ........................................ 21
ELECTRONIC CONTROL SETUP INSTRUCTIONS
(PD & PN MODELS) ..................................................................... 22
DRYER DISPOSAL ........................................................................ 27
WARRANTY ................................................................................... 28
TABLE DE MATIÈRES
SÉCURITÉ DE LE SECHE-LINGE ................................................29
POUR LE PROPRIÉTAIRE
INSTRUCTIONS D’ENTRETIEN .................................................. 32
SI VOUS AVEZ BESOIN D'ASSISTANCE ................................ 31
POUR LE PERSONNEL D’ENTRETIEN AUTORISÉ
PAR WHIRLPOOL
OUTILS ET PIÈCES ....................................................................... 33
SPÉCIFICATIONS .......................................................................... 33
DIMENSIONS/DÉGAGEMENT ................................................... 34
EXIGENCES D’INSTALLATION DE LE SECHE-LINGE .......... 35
INSTALLATION DES PIEDS DE NIVELLEMENT ET
DE LA BOÎTE À MONNAIE .......................................................... 36
NIVELLEMENT ................................................................................ 37
EXIGENCES D’INSTALLATION DE LE
SECHE-LINGE ÉLECTRIQUE ...................................................... 38
EXIGENCES D’INSTALLATION DE LE
SECHE-LINGE À GAZ ................................................................... 39
EXIGENCES CONCERNANT L’ÉVACUATION
DE LE SECHE-LINGE .................................................................... 41
RACCORDEMENT A LA CANALISATION DE GAZ ................ 43
CARACTÉRISTIQUES TECHNIQUES —
SECHE-LINGE À GAZ ................................................................... 44
ACHEVER L’INSTALLATION ........................................................ 46
INVERSION DU SENS D’OUVERTURE
DE LA PORTE (FACULTATIF) ...................................................... 47
INSTRUCTIONS DE RÉGLAGE DU
TABLEAU DE COMMANDE ÉLECTRONIQUE
(MODÈLES PD ET PN SEULEMENT) ........................................ 49
MISE AU REBUT DE LE SECHE-LINGE ................................... 54
GARANTIE ...................................................................................... 55
ÍNDICE
SEGURIDAD DE LA SECADORA ................................................56
PARA EL PROPIETARIO
INSTRUCCIONES DE MANTENIMIENTO ................................ 59
SI NECESITA ASISTENCIA ......................................................... 59
PARA EL PERSONAL DE SERVICIO AUTORIZADO
DE WHIRLPOOL
HERRAMIENTAS Y PIEZAS ........................................................ 60
ESPECIFICACIONES .................................................................... 60
DIMENSIONES Y ESPACIOS LIBRES ..................................... 59
REQUISITOS DE INSTALACIÓN DE LA SECADORA ........... 62
INSTALACIÓN DE LAS PATAS NIVELADORAS Y
CAJA DE MONEDAS ..................................................................... 63
NIVELACIÓN ................................................................................... 64
REQUISITOS DE INSTALACIÓN DE LA
SECADORA ELÉCTRICA.............................................................. 65
REQUISITOS DE INSTALACIÓN DE LA
SECADORA A GAS ....................................................................... 66
REQUISITOS DE VENTILACIÓN DE LA SECADORA ........... 68
CONEXIÓN DEL SUMINISTRO DE GAS ................................. 71
ESPECIFICACIONES TÉCNICAS - SECADORA A GAS ...... 72
INSTALACIÓN COMPLETA ......................................................... 74
CÓMO INVERTIR EL SENTIDO DE APERTURA
DE LA PUERTA ............................................................................... 75
INSTRUCCIONES DE PROGRAMACIÓN DEL CONTROL
ELECTRÓNICO (SOLO MODELOS PD Y PN) ......................... 76
ELIMINACIÓN DE LA SECADORA ............................................ 81
GARANTÍA ....................................................................................... 82
SOMMARIO
SICUREZZA DELL'ASCIUGATRICE ............................................ 83
PER IL PROPRIETARIO
ISTRUZIONI PER LA MANUTENZIONE ................................... 86
COME RICHIEDERE ASSISTENZA .......................................... 86
PER IL PERSONALE DI ASSISTENZA
AUTORIZZATO WHIRLPOOL
ATTREZZI E PARTI ........................................................................ 87
SPECIFICHE ................................................................................... 87
DIMENSIONI/SPAZI ................................................................... 88
REQUISITI PER L'INSTALLAZIONE
DELL'ASCIUGATRICE ................................................................... 89
INSTALLAZIONE DEI PIEDINI DI REGOLAZIONE
E GETTONIERA .............................................................................. 90
LIVELLAMENTO ............................................................................. 91
REQUISITI DELL’INSTALLAZIONE
DELLASCIUGATRICE ELETTRICO ............................................ 92
REQUISITI DELL’INSTALLAZIONE
DELLASCIUGATRICE A GAS .................................................... 93
REQUISITI DI SCARICO DELL'ASCIUGATRICE ..................... 95
COLLEGAMENTO DI ALIMENTAZIONE DEL GAS ................. 97
CARATTERISTICHE TECNICHE - ASCIUGATRICE
A GAS .............................................................................................. 98
COMPLETAMENTO DELL'INSTALLAZIONE ........................... 96
INVERTIRE IL SENSO DI APERTURA DELLO
SPORTELLO (FACOLTATIVO) ................................................... 101
ISTRUZIONI DI CONFIGURAZIONE DEI COMANDI
ELETTRONICI (SOLO MODELLI PD E PN) ........................... 102
ELIMINAZIONE DELL'ASCIUGATRICE ................................... 107
GARANZIA ................................................................................... 108
3
DRYER SAFETY
WARNING – “Risk of Fire”
This is an additional safety alert symbol that alerts you to the risk of fire.
WA RNING
-
“Risk of Fire
- Clothes dryer installation and service must be performed by a Whirlpool authorized
installer.
- Install the clothes dryer according to the manufacturer’s instructions and local codes.
by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will
-To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
4
DRYER SAFETY
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death or property
damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer
smells gas. This information should be obtained from your gas supplier.
Post the following warning in a prominent location.
FOR YOUR SAFETY
1. DO NOT USE OR STORE GAS OR OTHER FLAMMABLE MATERIALS IN THIS APPLIANCE OR NEAR THIS APPLIANCE.
2. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
3. DO NOT MODIFY THIS APPLIANCE.
5
DRYER SAFETY
The appliance is intended, but not limited, to be used in
public areas.
Children of less than 3 years should be kept away unless
continuously supervised.
The appliance must be disconnected from it's power
source during service and when replacing parts.
If drum rotation is blocked due to trapped textiles,
disconnect the dryer from the electrical supply before
gently removing the blockage.
If the dryer is not heating, or appears to be defective or
damaged, do not use it. Contact the owner.
Do not install or store the dryer where it will be exposed
to the weather.
Do not tamper with controls.
Clean dryer lint screen before or after each load.
Do not use this dryer without the lint screen in place.
Do not repair or replace any part of the dryer or attempt
any servicing unless specically recommended in this
Installation Instructions that you understand and have the
skills to carry out.
Fabric softeners, or similar products, should be used as
specied by the fabric softener instructions.
Items such as foam rubber (latex foam), shower caps,
waterproof textiles, rubber-backed articles and clothes or
pillows tted with foam rubber pads should not be dried
in the tumble dryer.
The nal part of a tumble dryer cycle occurs without
heat (cool-down cycle) to ensure that the articles are left
at a temperature that ensures that the items will not be
damaged.
WARNING: Never stop a tumble dryer before the end of
the drying cycle unless all items are quickly removed and
spread out so that the heat is dissipated. (Avoids risk of
spontaneous combustion).
In case of electrical supply failure, remove the load
quickly and spread it out to avoid risk of spontaneous
combustion.
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
The fresh air ventilation openings into the room and into
the dryer must not be blocked or sealed.
Emergency stop control: After installation, access to
mains plug (gas dryer) or mains supply (electric dryer)
via a double-pole switch must be maintained at all times
in order to ensure immediate deactivation of the dryer in
case of emergency.
The interior of the dryer and dryer exhaust vent should
be cleaned periodically by Whirlpool authorized service
personnel.
See “Electrical Requirements” section for earthing
instructions.
Adequate ventilation has to be provided to avoid the
back-ow of gases into the room from appliances burning
fuels, including open res.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of re, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
Read all instructions before using the dryer.
This dryer is intended only for drying clothes and textiles
that have been washed in water. Do not use for any other
purpose.
WARNING: If you smell gas, do not use the dryer or any
electrical equipment nearby. Warn other people to clear
the area. Contact the dryer owner immediately.
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute
to a chemical reaction that could cause a load to catch
re. To reduce the risk of re due to contaminated loads,
the nal part of a tumble dryer cycle occurs without heat
(cool down period). Avoid stopping a tumble dryer before
the end of the drying cycle unless all items are quickly
removed and spread out so that the heat is dissipated.
If it is unavoidable that fabrics that contain vegetable or
cooking oil or that have been contaminated by hair care
products be placed in a tumble dryer, they should rst
be washed in hot water with extra detergent – this will
reduce, but not eliminate the hazard.
Do not dry articles that have been previously cleaned
in, washed in, soaked in, or spotted with gas,
dry-cleaning solvents, other ammable, or explosive
substances as they give off vapors that could ignite
or explode.
Items that have been soiled with substances such as
acetone, alcohol, gas, kerosene, spot removers,
turpentine, waxes, and wax removers should be washed
in hot water with extra detergent before being dried in
the dryer.
Do not dry unwashed items in the dryer.
Do not use this dryer if industrial chemicals have been
used for cleaning. The possible presence of residual
quantities of aggressive or decomposed chemicals in the
load may produce damage to the dryer and harmful fumes.
Do not allow children to play on, in, or with the dryer.
Close supervision of children is necessary when the dryer
is used near children.
This dryer is not intended for use by persons (including
children) with reduced physical, sensory, or mental
capabilities, or lack of experience or knowledge,
unless they have been given supervision or instruction
concerning use of the dryer by a person responsible for
their safety.
Before the dryer is removed from service or discarded,
remove the door to the dryer compartment.
Do not reach into the dryer if the drum is moving.
Do not open door while dryer is in operation. It will stop.
When loading or re-loading the dryer, avoid touching hot
metal parts of the drum (burn risk).
Remove all objects from pockets such as lighters and
matches.
Cleaning and user maintenance shall not be made by
children without supervision.
WARNING: The appliance must not be supplied through
an external switching device, such as a timer, or connected
to a circuit that is regularly switched on and off by a utility.
The dryer must not be installed behind a lockable door, a
sliding door, or a door with a hinge on the opposite side to
that of the dryer in such a way that full opening of the dryer
door is restricted.
SAVE THESE INSTRUCTIONS
6
MAINTENANCE INSTRUCTIONS
If you need help, contact the dealer from whom you purchased the appliance, or a Maytag designated service company. When
calling, please know the purchase date and the complete model and serial number of your appliance. This information will help us to
better respond to your request.
IF YOU NEED ASSISTANCE
Clean lint screen before and after each cycle.
Removing accumulated lint:
From inside the dryer cabinet:
Lint should be removed every 2 years or more often,
depending on dryer usage. Cleaning should be done by
a Whirlpool authorized person.
From the exhaust vent:
Lint should be removed every 2 years, or more often,
depending on dryer usage.
Keep area around dryer clear and free from combustible
materials, gas, and other ammable vapors and liquids.
Keep dryer area clear and free from items that would
obstruct the ow of combustion and ventilation air.
If dryer does not operate, check the following:
Electrical supply is connected.
Circuit breaker is not tripped or house fuse is not blown.
Door is closed. Listen closely to hear the door switch
activate.
Controls are set in a running or “on” position.
For gas dryers, check that gas supply shut-off valves are
set in open position.
WARNING: Improper connection of the equipment-earthing conductor can result in a risk of electric
shock. It is your responsibility to check with a qualied electrician or service representative if you are in doubt
as to whether the dryer is properly earthed and meets all local codes and ordinances. Do not modify the plug
provided with the dryer: If it will not t the outlet, have a proper outlet installed by a qualied electrician.
IF YOU NEED SERVICE:
Contact your authorized Maytag Commercial Laundry distributor. To locate your authorized Maytag Commercial Laundry distributor,
visit www.maytagcommerciallaundry.com.
For written correspondence:
Maytag Commercial Laundry Service Department
2000 N M 63
Benton Harbor, Michigan 49022-2632 USA
7
Tools Needed:
203 mm (8") 203 mm (8") or 254 mm (10") Flat-Blade Screwdriver Phillips Screwdriver
or 254 mm (10") Adjustable Wrench
Pipe Wrench (that opens to 25 mm (1"))
Torx T-20
Security 25 mm (1") Hex-Head 8 mm (516") Socket Wrench Pliers (that open to
Screwdriver or Bit Socket Wrench 39 mm [1
9
/
16
"])
Level Utility Knife 6 mm (1/4") Nut Driver 686 mm (27")
Wood Block
Caulk Gun and Caulk Vent Clamps Pipe-Joint Compound Putty Knife
(for installing new exhaust vent) Suitable for Gas Type
Flashlight (optional) 25 mm (1") Ruler or Measuring Tape
Open-End Wrenches
TOOLS & PARTS
Parts Supplied:
Foot Boots (4) Leveling Legs (4) Security Cone 5/16" Hex Head – 18 x 2
1
2"
Security Bolt
TORX and T20 are trademarks of Acument Intellectual Properties, LLC.
These units are sold in multiple regions with different
requirements for measuring capacity. Below are a few of
the valid forms of measure posted on this product:
Dry Linen Capacity: A weight measure that reects a minimum
threshold for dry volume capacity that is needed for import
tariff purposes.
IEC Capacity: The capacity measure that represents the
maximum capacity of dry linens and textiles which the
manufacturer declares can be treated in a specic cycle.
Dry Linen Capacity
10.5 kg (23 lb)
IEC Capacity
9.0 kg (20 lb)
Sound Level
LpA: 58 dB(A) (Kpa+/-10 dB(A))
SPECIFICATIONS
NOTE: The circuit diagram for this dryer is located inside
the lower front panel, within the Tech Sheets.
Technical Specications:
220 – 240 V, 50 Hz. AC
4575W
Total mass: 68 kg max.
8
DIMENSIONS/CLEARANCES
Dimensions
Clearances
Side View Back View
743 mm
(29
1
/4")
889 mm
(35")
210 mm
(8
1
/4")
25 mm
(1")
660 mm
(26")
83 mm
(3
1
/4")
191 mm
(7
1
/2")
38 mm
(1
1
/2")
140 mm
(5
1
/2")
273 mm
(10
3
/
4
")
953 mm
(37
1
/2")
(gas models)
1042 mm
(41")
343 mm
(13
1
/
2
")
Electric
Gas
686 mm
(27")
83 mm
(3
1
/4")
914 mm
(36")
(electric models)
102 mm
(4" dia)
343 mm
(13
1
/2")
0 mm
(0")
0 mm
(0")
381 mm
(15")
356 mm
(14" max)
0 mm
(0")
Front View, Recessed Opening Side View, Recessed In Closet
127 mm
(5")
356 mm
(14" max)
25 mm
(1")
25 mm
(1")
76 mm
(3"/3")
76 mm
(3"/3")
310 cm
2
(48"
2
/48"
2
)
155 cm
2
(24"
2/
24"
2
)
381 mm
(15")
Closet Door to
Front of Dryer
9
Your dryer can be installed in a basement, laundry room, or
recessed area.
This dryer is not intended for installation in a mobile home.
Companion appliance location requirements should also be
considered.
IMPORTANT: Do not install or store the dryer where it
will be exposed to the weather. Proper installation is your
responsibility.
You will need:
An grounded electrical outlet located within 1.8 m (6 ft.) of
where the power cord is attached to the back of the dryer.
See “Electrical Requirements.”
A level oor with a maximum slope of 25 mm (1") under
entire dryer. Installing the dryer on soft oor surfaces,
such as carpets or surfaces with foam backing, is not
recommended.
Dryer installation clearances
The location must be large enough to allow the dryer door
to be fully opened.
Additional spacing should be considered for ease of
installation and servicing. The door opens more than 180°.
Additional clearances might be required for wall, door, and
oor moldings.
Additional spacing of 25 mm (1") on all sides of the dryer
is recommended to reduce noise transfer.
When installing a dryer:
IMPORTANT: Observe all governing codes and ordinances.
Check code requirements: Some codes limit or do not
permit installation of clothes dryers in garages, closets,
or sleeping quarters. Contact your local building inspector.
NOTE: For installation in Australia and New Zealand,
install dryer in accordance with AS/NZS 5601.1 and local
governance codes.
Gas Dryers only: Make sure that lower edges of the
cabinet, plus the back and bottom sides of the dryer, are
free of obstructions to permit adequate clearance of air
openings for combustion air. See “Recessed Area and
Closet Installation Instructions” below for minimum spacing
requirements.
Location Requirements
DRYER INSTALLATION REQUIREMENTS
(Australia and New Zealand – for full details of installation requirements refer to AS/NZS 5601.1)
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances
can be found on the warning label on the rear of the dryer
or in “Dimensions/Clearances.”
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air
opening in the top and bottom is required. The unobstructed
opening needs to be 1 square inch per 1,000 Btu (252 kcal)
of gas burner output. Output on North American gas dryers
is typically 22,000 Btu; however, Canadian dryers may have
lower output. Louvered doors with equivalent air openings are
acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
NOTE: For installation in Australia and New Zealand, refer to
AS/NZS 5601.1 for ventilation requirements.
Closet
Door
Front
View
10
INSTALLING LEVELING LEGS AND COIN BOX
1. Prepare dryer for leveling legs
NOTE: Slide dryer onto cardboard or hardboard before moving
to avoid damaging oor covering.
Using two or more people, move dryer to desired installation
location.
Take tape off front corners of dryer. Open dryer and remove
the literature and parts packages. Wipe drum interior with a
damp cloth to remove any dust.
Take two cardboard corners from the dryer carton and place
them on the oor in back of the dryer. Firmly grasp the body of
the dryer and gently lay it on its back on the cardboard corners.
Disconnect power before making electrical connections.
2. Screw in leveling legs
Examine leveling legs and nd diamond
marking. Screw legs into leg holes by
hand. Use an adjustable wrench or
25 mm (1") hex-head socket wrench
to nish turning legs until diamond
marking is no longer visible. Then t
a covered foot boot over each leg foot.
To protect the oor, use a large piece of cardboard from the
dryer carton. Stand dryer up on the cardboard. Slide the dryer
until it is close to its nal location. Leave enough room for
electrical connection and to connect the exhaust vent.
A longer leveling foot is available if needed on extremely sloped
oors, Part Number 279810.
Foot
Diamond
Marking
(appearance may vary)
The console houses the electronic control board. The board is
factory set for a dry time of 30 minutes. Consult the tech sheet
found inside the dryer toe panel to reset dry time and for other
options.
The card reading mechanism is not included, but is available
from your usual industry sources.
The meter case houses the factory-installed accumulator timer
with actuating arm or service switch.
The service door lock and key and coin box lock and key
may not be included but are available from the usual industry
sources.
1. Install coin box
Remove the service door of the meter case by lifting it up
at the back. Install the money-accepting device. (Refer to
manufacturer’s instructions for proper installation.)
Replace the meter case service door. Put the coin vault with
lock and key in the meter case opening.
Remove cardboard or hardboard from under dryer. Adjust the
legs of the dryer up or down until the dryer is level.
2. Install added security device
Check that power is not supplied to the dryer.
Open and remove the service door.
Insert the narrow part of the security cone into the oblong hole
in the bottom rear of the meter case assembly.
Pass the security bolt through this cone and thread it by hand
into the cage nut below the oblong hole.
Tighten the security bolt by hand a few turns before using a
wrench to tighten until snug.
NOTE: Installing the security bolt provides added security, but
will add to the service time when the top needs to be removed
for servicing the dryer.
security
bolt
security
cone
cage nut
Security
Bolt
Security
Cone
Cage
Nut
11
1. Remove cardboard from beneath dryer. Place a level on top
edges of dryer, checking each side and front. If not level,
tip dryer and adjust legs up or down as shown in Step 3,
repeating as necessary.
LEVELING
Leveling your dryer properly reduces excess noise and vibration.
Not Level LEVEL Not Level
2. Grip dryer from top and rock back and forth, making sure all
four legs are rmly on oor. Repeat, rocking dryer from side
to side. If dryer rocks, go to Step 3 and adjust leveling legs.
3. If dryer is not level, use a 25 mm or 1" open-end or
adjustable wrench to turn the leveling leg counterclockwise
to lower the dryer or clockwise to raise the dryer. Recheck
levelness of dryer and that all four legs are rmly in contact
with the oor. Repeat as needed.
HELPFUL TIP: You may want to prop up front of dryer
about 102 mm (4") with a wood block or similar object that
will support weight of dryer.
12
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Electrical Requirements
.
IMPORTANT: Observe all governing codes and ordinances.
This dryer is supplied without an electric cord and plug. It
must be connected by a Whirlpool authorized service person
to a single-phase electricity supply at the voltage shown
on the dataplate, using a suitable xed wiring installation in
accordance with local and national wiring regulations.
A 3-wire circular cord of minimum conductor size 2.5 mm
2
cross-section area should be used.
A 25 A (minimum) supply fuse should be used, and a switch
with a clear OFF marking having a contact separation in
both poles that provides full disconnection under over-
voltage category III conditions must be incorporated into the
xed wiring in accordance with local wiring regulations by
a Whirlpool authorized service person. The dryer should be
positioned so that the disconnection switch is clearly visible
and easily accessible to the user. This disconnection switch
also provides the function of an emergency stop control for
the user.
A cord clamp bush is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made
in accordance with the terminal markings. Remember to
replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electrical supply system
impedance to which the electric dryer should be connected
is declared to be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the
most appropriate for this product.
If codes permit and an additional ground bond wire is used, it
is recommended that a qualied electrician determine that the
ground bond path is adequate.
Recommended Earthing Method
It is your responsibility to contact a qualied electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
13
GAS DRYER INSTALLATION REQUIREMENTS
Electrical Requirements
EARTHING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IMPORTANT: Observe all governing codes and ordinances.
You will need a grounded electrical outlet located within
610 mm (2 feet) of either side of the dryer.
This dryer is supplied/tted with an electrical supply cord and
plug. It should be connected to electrical supply socket at the
voltage shown on the rating plate. The minimum supply fuse
capacity should be 10 A. The dryer must be positioned so that
the plug is clearly visible and accessible. This plug also provides
the function of an emergency stop control for the user. If the
tted plug is not used, the electrical connection must be carried
out by a competent electrician in accordance with local or
national codes.
If the supply cord is damaged, it must be replaced with a
specially terminated cord by an authorized service agent or
a similarly competent person in order to avoid a hazard.
Do not use an adapter.
Do not use an extension cord.
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electricity supply system
impedance to which the gas dryer should be connected is
declared to be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the
most appropriate for this product.
If codes permit and an additional ground bond wire is used, it
is recommended that a qualied electrician determine that the
ground bond path is adequate.
Using the universal cord included with this dryer:
The gas dryer is equipped with a universal cord with
interchangeable plugs.
1. To use the universal cord, select the plug end that ts
your electrical outlet, and plug it into the adapter on
the supply cord.
2. Secure the plug end in place on the cord by aligning
the 2 cover halves over the cord adapter and clipping
them together.
14
Gas Supply
GAS DRYER INSTALLATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances.
In Australia and New Zealand, refer to AS/NZS 5601.1 – Gas
Installations.
Gas Supply
Before installation, check that the local gas distribution
conditions, nature of gas and pressure, and the adjustment of
the appliance are compatible. Burner information will be found
on the model/serial rating plate in the door recess of the dryer.
If this information does not agree with the type of gas available,
see your dealer.
Natural Gas:
This dryer is factory adjusted for use with NATURAL GAS (G20),
and no further adjustment should be required at installation.
L.P. Gas:
This dryer is also certied for use with L.P. (propane or butane)
gases with appropriate conversion. No attempt shall be made
to convert the appliance from the gas specied on the model/
serial rating plate for use with a different gas without consulting
the serving gas supplier.
Conversion must be done by a Whirlpool authorized service
technician. Gas conversion kit (European Country), part number
W10233219, is available for purchase from your dealer. Gas
conversion kit (Australia), part number W10315369, is available
for purchase from your dealer. Full instructions are supplied
with the kit.
Natural Gas (France/Belgium):
This dryer is also certied for France/Belgium for use with G20/
G25 gases (20 mbar/25 mbar) with appropriate conversion. No
attempt should be made to convert this appliance from the gas
specied on the gas rating label for use with a different gas
without consulting the serving gas supplier. Gas conversion
must be done by a Whirlpool authorized gas service technician.
Conversion kit, part number (W10181947) is available for
purchase from your dealer. Full instructions are supplied with
the kit.
Supply line requirements:
Provide a rigid gas supply line to the dryer location. It should
be minimum 12.5 mm (1/2") ID. When acceptable to the gas
supplier and local codes, 10 mm (3/8") ID rigid supply line may
be used for lengths under 6.1 m (20'). Pipe-joint compounds
resistant to the action of L.P. gas must be used.
NOTE: For installation in Australia and New Zealand, refer to
AS/NZS 5601 for pipe sizing details. All piping is to be in
accordance with AS/NZS 5601.1 – Gas Installations.
Gas connection to the dryer itself should be made by means
of a exible gas hose suitable for the appliance and gas
category in accordance with national installation regulations. If
in doubt, contact the gas supplier. It should be minimum
10 mm (3/8") ID.
A means of restraint should be used between the dryer and the
wall to avoid straining of the rigid gas supply when the dryer
is moved. An appropriate length of chain and a wall hook is
recommended.
The dryer gas inlet connection is a 3/8" NPT thread. An adapter
is supplied for conversion to standard ISO.228-1 thread
(3/8" BSP).
Check for leaks by using an approved noncorrosive leak-
detection solution. Bubbles will show a leak. Correct any leak
found. A pressure measurement tapping is provided on the gas
valve within the dryer, accessible after removal of the lower
front panel.
The dryer must be disconnected from the gas supply piping
system during any pressure testing of that system.
15
DRYER VENTING REQUIREMENTS
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
In Australia and New Zealand, refer to AS/NZS 5601.1 – Gas
Installations.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
Only a 102 mm (4") heavy, metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.
Remove excess to avoid sagging and kinking that may result
in reduced airow and poor performance.
Do not install in enclosed walls, ceilings, or oors.
The total length should not exceed 2.4 m (7
3
4
ft.).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or exible metal vents. Review “Vent System Chart” and
if necessary, modify existing vent system to achieve best drying
performance.
102 mm (4") Heavy, Metal Exhaust Vent
Elbows:
45° elbows provide better airow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Better
Good
102 mm
(
4"
)
16
DRYER VENTING REQUIREMENTS
102 mm (4") Diameter Exhaust Hoods
Box Hood Louvered Hood Angled Hood
Vent Hoods
Exhaust hood must be at least 305 mm (12") from the ground
or any object that may be in the path of the exhaust (such as
owers, rocks, bushes, or snow).
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of 90˚ Turns
Box and
Louvered Hood
Angled Hood
0 39.6 m (130 ft.) 39.3 m (129 ft.)
1 38.1 m (125 ft.) 36.3 m (119 ft.)
2 35.1 m (115 ft) 33.2 m (109 ft.)
3 32.3 m (106 ft.) 30.5 m (100 ft.)
4 29.9 m (98 ft.) 28.0 m (92 ft.)
For vent systems not covered by the vent specication chart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
“Recessed Area and Closet Installation Instructions” in the
“Location Requirements” section.
A 102 mm (4") outlet hood is preferred. However, a 64 mm
(2
1
2
") outlet exhaust hood may be used. A 64 mm (2
1
2
") outlet
creates greater back pressure than other hood types. For
permanent installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer.
NOTE: Do not remove vent collar.
Vent System Length
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with
a 102 mm (4") clamp.
5. Move dryer into nal position. Do not crush or kink vent.
Make sure dryer is level.
NOTE: Testing for proper ventilation should be done with a
Manometer. Minimum: 0.01" (0.2 mm). Maximum: 0.6" (16 mm).
Vent Collar
12" min.
(305 mm)
305 mm min.
(12")
17
DRYER VENTING REQUIREMENTS
1. Connect gas supply to dryer. If the exible gas hose has
10 mm (3/8") BSP thread, use the supplied conversion
thread adapter. Use pipe-joint compound resistant to the
action of L.P. gas for gas connections.
Make Gas Connection
GAS SUPPLY CONNECTION (on some models)
The outside end of main vent should have a sweep elbow
directed downward.
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
610 mm (2 ft.) above surface of roof.
The opening in wall or roof shall have a diameter 13 mm (1⁄2")
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 l/min. (200 CFM) of
air per dryer. Large-capacity lint screens of proper design may
be used in main vent if checked and cleaned frequently. The
room where the dryers are located should have make-up air
equal to or greater than CFM of all the dryers in the room.
Back-draft dampers are available from your distributor and
should be installed in the vent of each dryer to keep exhausted
air from returning into dryers and to keep exhaust in balance
within main vent. Unobstructed return air openings are required.
Although usually each single-load dryer should have an
unobstructed outdoor air opening of 154 cm
2
(24 in.
2
) (based
on 6.5 cm
2
[1 in.
2
] per 252 kcal [1,000 Btu]), common make-up
air openings are also acceptable. Set up common openings so
the make-up air is distributed equally to all of the dryers. Keep
in mind that the coverage area must be increased by 33% to
account for the use of registers or louvers over the openings.
Also, make-up air openings should not be installed near the
location where exhaust vents exit the building.
Each vent should enter the main vent at an angle pointing in
the direction of the airow. Vents entering from the opposite
side should be staggered to reduce the exhausted air from
interfering with the other vents.
The maximum angle of each vent entering the main vent should
be no more than 30°.
Keep air openings free of dry cleaning uid fumes. Fumes
create acids which, when drawn through the dryer heating
units, can damage dryers and items being dried.
A clean-out cover should be located on the main vent for
periodic cleaning of the vent system.
NOTE: For more dryer venting information, please refer to
Whirlpool document W10100920.
If an Exhaust Hood Cannot be Used Multiple Dryer Venting
* Minimum clearance above
any accumulation of snow,
ice, or debris such as leaves
30˚ max.
Air ow
Air Flow
If necessary for service, open the toe panel. Use a putty
knife to press on the 2 toe panel locks located at the top
of the toe panel. Pull downward on the toe panel to open.
Toe panel is hinged at the bottom.
2. Open the shut-off valve in the gas supply line and make
sure the dryer has its own gas supply opened.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show
a leak. Correct any leaks found.
18
TECHNICAL SPECIFICATIONS – GAS DRYER
220–240 V~50 Hz 1 ph 3 A max. IP24 Clothes capacity: 9.0 kg max. Sound pressure level, Lpa: 58 dBA (uncertainty, Kpa: +/-10
dBA) Total mass: 68 kg max.
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
European Country:
CH, CZ, CY, ES, GB, GR,
IE, IT, LT, PT, SI, SK, TR
BG, CY, CZ, DK, EE, FI, GR,
HR, IT, LT, NO, RO, SE, SI, SK
European Gas Category: II
2H3+
II
2H3B/P
Gas Flow Rate: 0.562703 m
3
/hr 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar 20 mbar
Factory Adjusted Pressure: 7.4 mbar 7.4 mbar
With L.P. Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
European Country:
CH, CZ, CY, ES, GB, GR,
IE, IT, LT, PT, SI, SK, TR
BG, CY, CZ, DK, EE, FI, GR,
HR, IT, LT, NO, RO, SE, SI, SK
European Gas Category:
II
2H3+
II
2H3B/P
Butane Supply Pressure (G30): 28-30 mbar 30 mbar
Adjusted Pressure: N/A N/A
L.P. Supply Pressure (G31): 37 mbar 30 mbar
Adjusted Pressure: N/A N/A
With France/Belgium NATURAL GAS conversion kit: Injector size 1.65 mm Heat input gross: 5.9 kW
European Country: FR, BE
European Gas Category:
I
2E+
Supply Pressure (G20): 20 mbar
Supply Pressure (G25): 25 mbar
Adjusted Pressure: N/A
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
AT, BG, CH, CZ, DK, EE, ES, FI, GB, GR, HR,
IE, IS, IT, LT, LV, NO, PT, RO, SE, SI, SK, TR
European Gas Category: I
2H
Gas Flow Rate: 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar
Factory Adjusted Pressure (G20): 7.4 mbar
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country: LU, RO
European Gas Category: II
2E3B/P
Gas Flow Rate: 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar
Factory Adjusted Pressure (G20): 7.4 mbar
With L.P. Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
Country: LU, RO
European Gas Category: II
2E3B/P
Butane Supply Pressure (G30): 30 mbar
Adjusted Pressure: N/A
L.P. Supply Pressure (G31): 30 mbar
Adjusted Pressure: N/A
19
TECHNICAL SPECIFICATIONS – GAS DRYER
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country: DE, LU, PL, RO
European Gas Category:
I
2E
Gas Flow Rate: 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar
Factory Adjusted Pressure (G20): 7.4 mbar
Factory set for Australia/New Zealand NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country: AU, NZ
Supply Pressure (G20): minimum 1.13 kPa
Adjusted Pressure (Test Point Pressure): 0.74 kPa
Nominal Hourly Gas Consumption: 21.1 MJ/h
With Australia L.P. Gas Conversion Kit: Injector Size: 1.40 mm Heat input gross: 6.54 kW
Country: AU, NZ
L.P. Supply Pressure: 2.75 kPa
Adjusted Pressure: 2.75 kPa
Nominal Hourly Gas Consumption: 23 MJ/h
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.0 kW
Country: NL
European Gas Category:
I
2L
II
2L3B/P
Gas Flow Rate: 0.562703 m
3
/hr 0.562703 m
3
/hr
Gas Flow Rate: 25 mbar 25 mbar
Factory Adjusted Pressure (G25) : 7.4 mbar 7.4 mbar
With L.P. Gas Conversion Kit: Injector size: 1.25 mm Heal input gross: 6.4 kW
Country: MT, PL NL
European Gas Category
I
3B/P
II
2L3B/P
Butane Supply Pressure (G30) 30 mbar
Adjusted Pressure: N/A
L.P. Supply Pressure: 30 mbar
Adjusted Pressure: N/A
NOTE: Conversion kit: From Natural Gas to L.P. Gas - Europe: Whirlpool Part No. W10233219.
Conversion kit: From Natural Gas to L.P. Gas - Australia: Whirlpool Part No. W10315369.
Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10181947.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan 49022, U.S.A.
Manufacturing Site: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH, 43302, U.S.A.
EU Representatives: Whirlpool EMEA S.p.A., Via Carlo Pisacane, 1, 20016 Pero (MI) Italy
20
1. Check the electrical requirements. Be sure that you have
the correct electrical supply and the recommended earthing
method. See “Electrical Requirements.”
2. Check that all parts are now installed. If there is an extra
part, go back through the steps.
3. Check that you have all of your tools.
4. Dispose of/recycle all packaging materials.
5. Plug into an grounded outlet, or connect power.
6. Check dryer operation. Close dryer door. Set the cycle.
Operating time will accumulate per number of coins.
Using a full heat cycle (not the air cycle), let the dryer run
for at least ve minutes. Dryer will stop when time is used
up. Make sure the dryer turns off.
NOTE: Dryer door must be closed for dryer to operate.
When door is open, dryer stops, but timer continues to run.
7. Gas Models only: Open the dryer door. Check that the
inside of the dryer is warm. If the burner does not ignite
and you can feel no heat inside the dryer, shut off dryer for
5 minutes. Check that all supply valve controls are in “ON”
position and that the electrical cord is plugged in. Repeat
ve-minute test.
8. If drying time is too long, make sure that the lint screen is
clean and that there are no obstructions to airow in the
dryer vent system.
9. Restart the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.
COMPLETE INSTALLATION
WARNING
Electric Shock Hazard
This dryer must be earthed.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electric shock.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108

Maytag MDG20PDAGW Installation Instructions Manual

Catégorie
Sèche-linge électriques
Taper
Installation Instructions Manual

dans d''autres langues