The SuperStack
®
3 Baseline 10/100 Switch 24-Port
10BASE-T/100BASE-TX plus 2-Port 1000BASE-T is a versatile,
easy-to-use unmanaged switch. It is ideal for users who want the
high-speed performance of 10/100 switching with the added
functionality of 1000BASE-T links but do not need sophisticated
management capabilities. The Baseline 10/100 Switch is shipped
ready for use. No configuration is necessary.
The Baseline 10/100 Switch has 24 shielded RJ-45, 10/100 Mbps
auto-negotiating ports and two shielded RJ-45, 1000BASE-T ports
on the front panel. Each 10/100 Mbps port automatically
determines the speed and duplex mode of the connected
equipment and provides a suitable switched connection. The
1000BASE-T ports also support automatic 10/100/1000 Mbps
speed detection. The 10/100 Mbps connections on these
1000BASE-T ports operate in half or full duplex mode while the
1000 Mbps connections operate in full duplex mode.
The Baseline 10/100 Switch is suitable for office use where it can
be free-standing, or rack mounted (in a wiring closet or
equipment room).
The Baseline 10/100 Switch comes with:
One power cord
Four standard height, self-adhesive rubber pads
One mounting kit
The Switch is powered from the AC supply.
The Baseline 10/100 Switch provides high performance switched
connections to 10 Mbps and 100 Mbps hubs, servers and
workstations that need a dedicated switched link and the
1000 Mbps ports that can connect to other 10/100/1000 Mbps
ports or servers/workstations.
INTRODUCTION
SuperStack
®
3 Baseline 10/100 Switch 24-Port 10BASE-T/100BASE-TX
plus 2-Port 1000BASE-T (3C16475) User Guide
DUA1647-5AAA01
1
13
12
16
17
20
24
21
4
8
9
5
1
The numbers in this diagram refer to numbered sections in the
text.
Front Panel
1 24 RJ-45 10/100 Ports and 2 RJ-45 1000 Ports
WARNING: RJ-45 Ports. These are shielded RJ-45 data
sockets. They cannot be used as standard traditional
telephone sockets, or to connect the unit to a traditional
PBX or public telephone network. Only connect RJ-45
data connectors, network telephony systems, or network
telephones to these sockets.
Either shielded or unshielded data cables with shielded or
unshielded jacks can be connected to these data sockets.
AVERTISSEMENT: Points d’accès RJ-45. Ceux-ci sont
protégés par des prises de données. Ils ne peuvent pas
être utilisés comme prises de téléphone conventionnelles
standard, ni pour la connection de l’unité à un réseau
téléphonique central privé ou public. Raccorder seulement
connecteurs de données RJ-45, systèmes de réseaux de
téléphonie ou téléphones de réseaux à ces prises.
Il est possible de raccorder des câbles protégés ou non
protégés avec des jacks protégés ou non protégés à ces
prises de données.
WARNHINWEIS: RJ-45-Porte. Diese Porte sind geschützte
Datensteckdosen. Sie dürfen weder wie normale
traditionelle Telefonsteckdosen noch für die Verbindung
der Einheit mit einem traditionellem privatem oder
öffentlichem Telefonnetzwerk gebraucht werden. Nur
RJ-45-Datenanscluße, Telefonnetzsysteme or Netztelefone
an diese Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen
an diese Datensteckdosen angeschlossen werden.
10BASE-T/100BASE-TX Ports
The Baseline 10/100 Switch has 24 10/100 Mbps auto-negotiating
ports. Each port supports automatic MDI/MDI-X detection and can
be connected to either a 10BASE-T or a 100BASE-TX device.
Ports 1 to 24 are auto-negotiating: their speed and duplex mode
(half duplex or full duplex) are automatically determined by the
capabilities of the connected device.
The Switch offers priority queuing, which means all packets that
are received are examined to see if they have been priority
encoded. If a packet has been, then the Switch will read the
priority level and determine whether the packet should be
directed through the normal or high priority channel. This feature
can be useful for example during excessive loads when one type
of traffic may require priority over another. The Switch is
configured to comply with 802.1p, VLAN tagged frames.
Traffic prioritization ensures that high priority data is forwarded
through the Switch without being delayed by lower priority data.
It differentiates traffic into classes and prioritizes those classes
automatically. Traffic prioritization uses the multiple traffic queues
that are present in the hardware of the Switch to ensure that
high priority traffic is forwarded on a different queue from lower
priority traffic, and is given preference over that traffic. This
ensures that time-sensitive traffic gets the highest level of service.
The 802.1D standard specifies eight distinct levels of priority (0 to
7), each of which relates to a particular type of traffic. The priority
levels and their traffic types are shown in the following table.
The traffic prioritization feature supported by the Switch
is compatible with the relevant sections of the IEEE
802.1D standard (incorporating IEEE 802.1p).
If you connect two Baseline 10/100 Switch units together,
the link between them operates at 100 Mbps full duplex.
You must use Category 5 cable when connecting the
units.
CAUTION: The Baseline 10/100 Switch supports full
duplex auto-negotiation. If the connected device does not
support auto-negotiation, the Switch will operate in half
duplex mode (even if the device is operating in full duplex
mode). In such a configuration, you may notice some
degradation of network performance. 3Com recommends
that you use devices that are capable of auto-negotiation
(and that you ensure that auto-negotiation is enabled, if
it is a configurable option).
HOW TO USE THE BASELINE 10/100 SWITCH 24-PORT
1
2
3
4
6
5
16
1
13
4
17
5
8
20
9
12
21 24
Priority Level Traffic Type
0 Best Effort
1 Background
2 Standard (spare)
3 Excellent Effort (business critical)
4 Controlled Load (streaming multimedia)
5 Video (Interactive media), less than 100 millisecondsn
latency and jitter.
6 Voice (Interactive voice), less than 10 milliseconds
latency and jitter.
7 Network Control Reserved traffic
!
2
1000BASE-T Ports
Ports 25 and 26 are 1000BASE-T ports capable of
auto-negotiating with the connected port to operate at
1000BASE-T full duplex as well as 10/100Mbps in half or full
duplex mode. These two 1000BASE-T ports auto-sense
MDI/MDI-X connections and can be used to connect to either
other 10/100/1000 Mbps switch ports or to a 10/100/1000 Mbps
server or workstation without additional configuration.
Connecting to a Network Device
To connect a device to the Baseline 10/100 Switch, use
Category 5 unshielded or shielded (screened) 100 Ohm TP cable
(or Category 3 cable for a 10 Mbps connection). The maximum
length of cable for each connection is 100 m (328 ft). Connect
one end of the cable to an RJ-45 port on the Baseline 10/100
Switch, and the other end to the appropriate RJ-45 port on the
connecting device.
Connecting to another Switch or Hub
If you connect two Baseline 10/100 Switch units together,
3Com recommends that you use the 1000BASE-T ports
on both units for the link. You must use Category 5 cable
when connecting the units.
1000BASE-T connection: To connect a Baseline 10/100 Switch to
other switches using the 1000BASE-T ports, use a normal ‘straight
through’ cable and connect each end to the 1000BASE-T ports on
each unit.
100BASE-TX connection: To connect the Baseline 10/100 Switch
to a SuperStack 3 hub using a normal ‘straight through’ cable,
connect any port on the Baseline 10/100 Switch to the
MDI/MDI-X port on the hub, as shown below. Ensure that the
MDI switch on the hub is in (MDI).
2
Activity/Link/Speed Status LEDs
The first (top) and third row of LEDs, which are colored yellow or
green, show the activity and speed status of the related ports:
10BASE-T/100BASE-TX Ports
1000BASE-T Ports (Ports 25 and 26)
3 Duplex Status LEDs
The second and fourth (bottom) row of Status LEDs, which are
colored yellow, show the duplex status of the related ports:
1000BASE-T only operates in full duplex mode.
10BASE-T/100BASE-TX can be in half or full duplex mode.
4
Power LED
The Power LED shows the power status of the Switch:
5
Self-adhesive Pads
The unit is supplied with four self-adhesive rubber pads.
You do not need to apply the pads if you intend to rack
mount the unit.
If the unit is to be part of a free-standing stack, apply the pads to
each marked corner area on the underside of the unit. Place the
unit on top of the lower unit, ensuring that the pads locate with
the recesses of the lower unit.
Rear Panel Connections
6 Power Supply
The Baseline 10/100 Switch automatically adjusts to the supply
voltage. Only use the power cord that is supplied with the unit.
Status Meaning
On The link has been established.
Flashing Packets are being received or transmitted on the port.
Off If the link has not been established, either nothing is
connected to the port, or there is a problem:
Check that the attached device is powered on.
Check that the cable is the correct type and is not faulty.
If these checks do not identify the cause of the problem, it
may be that the unit or the device connected to the port is
faulty. Contact your supplier for further advice.
Green The link is operating at 100 Mbps.
Yellow The link is operating at 10 Mbps.
1
13
12
16
17
20
24
21
4
8
9
5
1
13
12
16
17
20
24
21
4
8
9
5
Set switch to
MDI (in)
Unit 1
3C16411 Hub
Unit 2
3C16475
Status Meaning
On The link has been established.
Flashing Packets are being received or transmitted on the port.
Off If the link has not been established, either nothing is
connected to the port, or there is a problem:
Check that the attached device is powered on.
Check that the cable is the correct type and is not faulty.
If these checks do not identify the cause of the problem, it
may be that the unit or the device connected to the port is
faulty. Contact your supplier for further advice.
Green The link is operating at 1000 Mbps.
Yellow The link is operating at 10/100 Mbps.
Status Meaning
On Yellow The port is operating in full duplex mode.
Off The port is operating in half duplex mode.
Status Meaning
On Green The unit is powered on and ready for use.
Off The unit is not receiving power:
Check the power cord is connected correctly.
If the unit still does not operate, contact your supplier.
3
Positioning the Switch
When deciding where to position the Baseline 10/100 Switch
ensure that:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise. These include
lift shafts, microwave ovens, and air conditioning units.
Electromagnetic fields can interfere with the signals on copper
cabling and introduce errors, therefore slowing down your
network.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the side of
the case is not restricted (3Com recommend that you provide
a minimum of 25mm (1in.) clearance).
The air is as free from dust as possible.
Temperature operating limits are not likely to be exceeded. It
is recommended that the unit is installed in a clean, air
conditioned environment.
It is always good practice to wear an anti-static wrist
strap when installing network equipment, connected to a
ground point. If one is not available, try to keep in
contact with a grounded rack and avoid touching the
unit's ports and connectors, if possible. Static discharge
can cause reliability problems in your equipment.
Rack Mounting or Free Standing
The unit can be mounted in a 19-inch equipment rack using the
Mounting Kit. Refer to “Mounting Kit Instructions” on page 4, or
it can be free standing. Do not place objects on top of the unit or
stack.
CAUTION: If installing the Baseline 10/100 Switch in a
free-standing stack of different size SuperStack 3 units,
the smaller units must be installed above the larger ones.
Do not have a free-standing stack of more than six units.
Power Supply
Power problems can be the cause of serious failures and
downtime in your network. Ensure that the power input to your
system is clean and free from sags and surges to avoid
unforeseen network outages. We recommend that you install
power conditioning, especially in areas prone to black outs, power
dips and electrical storms.
The unit is intended to be grounded. Ensure it is connected to
earth ground during normal use. Installing proper grounding helps
to avoid damage from lightning and power surges.
Power Up
Use the following sequence to power up the Baseline 10/100
Switch:
1 Check the network connections and cables.
2 Connect the power supply cable to the appropriate power
socket on the rear panel of the unit; refer to 4 or 6.
3 Connect the plug to the power supply outlet socket and
switch on the power supply at the socket.
When the switch is powered on, the Power LED should be lit on.
If it is not, refer to 4.
Spot Checks
At frequent intervals you should visually check the Baseline
10/100 Switch. Regular checks can give you an early warning of a
possible failure; any problems can then be attended to when
there will be least effect on users. Check the following:
If you experience any problems operating the Baseline 10/100
Switch, refer to “Problem Solving” on page 4.
Introduction
The Baseline 10/100 Switch is supplied with two mounting
brackets and four screws. These are used for rack mounting the
unit. When mounting the unit, you should take note of the
guidelines given in “Positioning the Switch” on page 3.
Rack Mounting the Units
The Baseline 10/100 Switch is 1U high and will fit a standard
19-inch rack.
CAUTION: Disconnect all cables from the unit before
continuing. Remove the self-adhesive pads from the
underside of unit, if already fitted.
1 Place the unit the right way up on a hard, flat surface with
the front facing towards you.
2 Locate a mounting bracket over the mounting holes on one
side of the unit.
3 Insert the two screws supplied in the mounting kit and fully
tighten with a suitable screwdriver.
4 Repeat the two previous steps for the other side of the unit.
5 Insert the unit into the 19-inch rack and secure with suitable
screws (not provided).
6 Reconnect all cables.
INSTALLATION RECOMMENDATIONS
!
Cabling Check that all external cabling connections are secure
and that no cables are pulled taut.
Cooling fan Where possible, check that the cooling fan is operating
by listening to the unit. The fan is fitted near to the front
right hand side of the unit (when viewed from the front).
MOUNTING KIT INSTRUCTIONS
4
Refer to the information about LEDs given earlier in this guide to
see if the problem can be identified and rectified. Here are some
common problems that can occur:
The Status LED not lit for a port that has a connection.
There is a problem with this connection. Check that:
The device being connected to is powered on and operating
correctly.
The cable is connected at both ends.
The cable is not damaged.
If the connection is to a workstation, that the workstation’s
network interface is installed and configured correctly.
All ports appear to show continual activity.
There may be broadcast storms on the network.
Remove port connections one at a time, waiting a few seconds
between each port. If the LEDs go off after removing a port
connection, the device that was connected to that port is
introducing an excessive amount of broadcast frames to the
network (some pieces of network equipment operate by sending
out broadcast frames regularly). Refer to the documentation that
accompanies the device for information on disabling the
broadcast operation.
If the problem persists and the unit still does not operate
successfully, contact your supplier with the following information
before returning the unit:
Product number and serial number (printed on a label
supplied with the unit)
A brief description of the fault
PROBLEM SOLVING
5
Please read the following safety information carefully
before installing the Baseline 10/100 Switch.
WARNING: Installation and removal of the unit must be carried out
by qualified personnel only.
If installing the Switch unit in a stack with SuperStack 3 Hub units, the
Baseline 10/100 Switch unit must be installed below the narrower Hub
units.
The unit must be connected to an earthed (grounded) outlet to comply
with international safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an
earth (ground) connection.
The appliance coupler (the connector to the unit and not the wall plug)
must have a configuration for mating with an EN60320/IEC320
appliance inlet.
The socket outlet must be near to the unit and easily accessible. You
can only remove power from the unit by disconnecting the power cord
from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 60. The conditions are only maintained if the
equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
supplies. If your supplies are of IT type, this
unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with
the secondary connection point labelled Neutral, connected directly to earth
(ground).
Impédance à la terre
Power Cord Set
This must be approved for the country where it will be used.
Veuillez lire à fond l'information de la sécurité suivante avant
d'installer le Baseline 10/100 Switch.
AVERTISSEMENT: L’installation et la dépose de ce groupe doivent
être confiés à un personnel qualifié.
Si vous entassez l’unité Switch avec les unités SuperStack 3 Hub, l’unité
Baseline 10/100 Switch doit être installée en dessous des unités Hub
plus étroites.
Ne branchez pas votre appareil sur une prise secteur (alimentation
électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la
masse).
Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la
masse) afin de respecter les normes internationales de sécurité.
Le coupleur d’appareil (le connecteur du groupe et non pas la prise
murale) doit respecter une configuration qui permet un branchement
sur une entrée d’appareil EN60320/IEC 320.
La prise secteur doit se trouver à proximité de l’appareil et son accès
doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en
débranchant son cordon électrique au niveau de cette prise.
L’appareil fonctionne à une tension extrêmement basse de sécurité qui
est conforme à la norme IEC60950. Ces conditions ne sont maintenues
que si l’équipement auquel il est raccordé fonctionne dans les mêmes
conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par
une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport
1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec
raccordement direct à la terre (masse).
Cordon électrique
Il doit être agréé dans le pays d’utilisation.
Bitte unbedingt vor dem Einbauen des Baseline 10/100 Switch
Einheit die folgenden Sicherheitsanweisungen durchlesen.
WARNUNG: Die Installation und der Ausbau des Geräts darf nur
durch Fachpersonal erfolgen.
Wenn die Baseline 10/100 Switch Einheit in einer Stapel mit anderen
SuperStack 3 Hub Einheiten eingebaut werden soll, muß die Baseline
10/100 Switch Einheit unter die schmaleren Hub Einheiten eingebaut
werden.
Das Gerät nicht an eine Wechselstromsteckdose anschließen, die nicht
geerdet ist.
Das Gerät muß an eine geerdete Steckdose angeschlossen werden, die
die internationalen Sicherheitsnormen erfüllt.
Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß eine passende Konfiguration für einen
Geräteeingang gemäß EN60320/IEC320 haben.
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich
sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
SAFETY INFORMATION
U.S.A. and
Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10 A.
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A,
250 V) configuration.
Denmark
The supply plug must comply with Section 107-2-D1,
Standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
UK
The supply plug must comply with BS1363 (3-pin 13-amp)
and be fitted with a 5 A fuse which complies with
BS1362.
The mains cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
Europe
The supply plug must comply with CEE7/7 (“SCHUKO”)
The mains cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
L’INFORMATION DE SÉCURITÉ IMPORTANTE
Etats-Unis et
Canada:
Le cordon doit avoir reçu l’homologation des UL et un
certificat de la CSA.
Le cordon souple doit respecter, à titre minimum, les
spécifications suivantes:
calibre 18 AWG
type SV ou SJ
à 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant
nominal d’au moins 10 A.
La prise femelle de branchement doit être du type à mise à la
terre (mise à la masse) et respecter la configuration NEMA
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
Danemark:
La prise mâle d’alimentation doit respecter la section 107-2 D1
de la norme DK2 1a ou DK2 5a.
Suisse:
La prise mâle d’alimentation doit respecter la norme SEV/ASE
1011.
Europe
La prise secteur doit être conforme aux normes CEE 7/7
(“SCHUKO”)
LE cordon secteur doit porter la mention <HAR> ou <BASEC>
et doit être de type HO3VVF3GO.75 (minimum).
WICHTIGE SICHERHEITSINFORMATIONEN
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
Schweiz
Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen
einhalten.
Europe Das Netzkabel muß vom Typ HO3VVF3GO.75
(Mindestanforderung) sein und die Aufschrift <HAR> oder
<BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
6
Related Standards
The SuperStack 3 Baseline 10/100 Switch has been designed to
the following standards:
Environmental
Physical
Electrical
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference to radio
communications, in which case the user will be required to correct the interference
at their own expense.
Information To The User
If this equipment does cause interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient the receiving antenna.
Relocate the equipment with respect to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that equipment and receiver are on
different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television
technician for additional suggestions. The user may find the following booklet
prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington,
DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with
cables which comply with IEEE 802.3.
CE Statement (Europe)
This product complies with the European Low Voltage Directive 73/23/EEC and EMC
Directive 89/336/EEC as amended by European Directive 93/68/EEC/.
CSA Statement
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement
sur le matériel brouilleur du Canada.
VCCI Statement
BSMI Statement
© 3Com Technologies, 2002. All rights reserved. No part of this documentation
may be reproduced in any form or by any means or used to make any derivative
work (such as translation, transformation, or adaptation) without permission from
3Com Technologies.
3Com Technologies reserves the right to revise this documentation and to make
changes in content from time to time without obligation on the part of 3Com
Technologies to provide notification of such revision or change.
3Com Technologies provides this documentation without warranty of any kind,
either implied or expressed, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. 3Com may make improvements
or changes in the product(s) and/or the program(s) described in this documentation
at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation and the
software described herein are provided to you subject to the following restricted
rights:
For units of the Department of Defense:
Restricted Rights Legend: Use, duplication or disclosure by the Government is
subject to restrictions as set forth in subparagraph (c) (1) (ii) for restricted Rights in
Technical Data and Computer Software clause at 48 C.F.R. 52.227-7013. 3Com
Centre, Boundary Way, Maylands Park South, Hemel Hempstead, Herts, HP2 7YU,
U.K.
For civilian agencies:
Restricted Rights Legend: Use, reproduction or disclosure is subject to restrictions set
forth in subparagraph (a) through (d) of the Commercial Computer Software -
Restricted Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in
3Com Corporation’s standard commercial agreement for the software. Unpublished
rights reserved under the copyright laws of the United States.
If there is any software on removable media described in this documentation, it is
furnished under a license agreement included with the product as a separate
document, in the hard copy documentation, or on the removable media in a
directory file named LICENSE.TXT. If you are unable to locate a copy, please contact
3Com and a copy will be provided to you.
Unless otherwise indicated, 3Com registered trademarks are registered in the United
States and may or may not be registered in other countries.
3Com and SuperStack are registered trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or trademarks of
their respective holders.
TECHNICAL INFORMATION
Functional
ISO 8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast
Ethernet), IEEE 802.3ab (Gigabit Ethernet) IEEE 802.3x
(Flow Control) IEEE 802.1D 1998 (Bridging)
MAC Address
8192
Safety
UL 1950, EN 60950, CSA 22.2 #950, IEC 60950
EMC Emissions
EN 55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A,
CNS 13438 Class A
Immunity
EN 55024
Operating Temperature
0–40 °C (32–104 °F)
Humidity
10–95% (non-condensing)
Standard
EN 60068 (IEC 68)—various parts
Width
440 mm (17.3 in.)
Depth
173 mm (6.8 in.)
Height
44 mm (1.7 in.) or 1U
Weight
2.6 kg (5.8 lb)
Mounting
Free standing, or 19 in. rack mounted using the
mounting kit supplied
Power Inlet
IEC 320
AC Line Frequency
50/60 Hz
Input Voltage
100–240 VAC
Current Rating
1 Amp (maximum)
Maximum Power
Consumption
28 VA
Maximum Power
Dissipation
95.6 BTU/hr
REGULATORY NOTICES
LEGAL NOTICES
7
.
The following options are available for technical support:
In the first instance contact your Network Supplier.
Check the 3Com knowledgebase at
http://knowledgebase.3com.com
Browse the 3Com web site on http://www.3com.com
Please have your product model name, part number, hardware
revision number and serial number along with all relevant details
of the problem to hand before calling your Network Supplier or
3Com on the numbers below.
The SuperStack 3 Baseline 10/100 Switch is part of the extensive SuperStack 3
range of 3Com products. This range includes hubs, switches, power systems and
other networking equipment, and is continually being developed. Contact your
supplier for the latest product information and to order these products.
Product Registration
You can now register your SuperStack 3 Switch on the 3Com web site to receive
up-to-date information on your product:
http://support.3com.com/registration/frontpg.pl
Feedback
Your suggestions are very important to us. They will help make our documentation
more useful to you. Please e-mail comments about this document to 3Com at:
Please include the following information when commenting: the document title,
part number (shown at the bottom of this page), and page number, if appropriate.
Environmental Statement
It is the policy of 3Com Corporation to be environmentally-friendly in all operations.
To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national
legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations.
Ensuring that all waste conforms to recognized environmental standards.
Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental
standards.
Improving our environmental record on a continual basis.
TECHNICAL SUPPORT
Country Telephone Number Country Telephone Number
Asia, Pacific Rim
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
1 800 678 515
800 933 486
+61 2 9424 5179 or
000800 650 1111
001 803 61009
00531 616 439 or
03 5977 7991
1800 801 777
0800 446 398
+61 2 9937 5083
Philippines
P.R. of China
Singapore
S. Korea
Tai wan
Thailand
1235 61 266 2602 or
+61 2 9937 5076
10800 61 00137 or
021 6350 1590 or
00800 0638 3266
800 6161 463
00798 611 2230 or
02 3455 6455
0080 611 261
001 800 611 2000
Europe, Middle East and Africa
From anywhere in these regions, call: +44 (0)1442 435529 phone
+44 (0)1442 432524 fax
From the following countries, you may use the toll-free numbers:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
Israel
Italy
0800 297468
0800 71429
800 17309
0800 113153
0800 917959
0800 1821502
06800 12813
1800 553117
1800 9453794
800 879489
Luxembourg
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
0800 3625
0800 0227788
800 11376
00800 3111206
800 831416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
Latin America
From the Caribbean, Central and South America, call:
Antigua
Argentina
Aruba
Bahamas
Barbados
Belize
Bermuda
Bonaire
Brazil
Cayman
Chile
Colombia
Costa Rica
Curacao
Ecuador
Dominican Republic
1 800 988 2112
0 810 444 3COM
1 800 998 2112
1 800 998 2112
1 800 998 2112
52 5 201 0010
1 800 998 2112
1 800 998 2112
0800 13 3COM
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
Guatemala
Haiti
Honduras
Jamiaca
Martinique
Mexico
Nicaragua
Panama
Paraguay
Peru
Puerto Rico
Salvador
Trinidad and Tobago
Uruguay
Venezuela
Virgin Islands
AT&T +800 998 2112
57 1 657 0888
AT&T +800 998 2112
1 800 998 2112
571 657 0888
01 800 849CARE
AT&T +800 998 2112
AT&T +800 998 2112
54 11 4894 1888
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
57 1 657 0888
North America 1 800 876 3266
PRODUCTS
Part Number: DUA1647-5AAA01
Published: June 2002