Saniflo 041 Guide d'installation

Taper
Guide d'installation
1
03.15
IND1
256
SANICONDENS
®
Best
CDN
US FR
IMPORTANT
DO NOT RETURN ANY MERCHANDISE TO THE VENDOR
NE PAS RETOURNER DE MARCHANDISE AU VENDEUR
For customer Service, Returns or Technical Questions, please call Saniflo’s Technical support toll-free at
800-571-8191 (USA) or 800-363-5874 (CDN).
Pour le service client, les retours ou toute question technique, merci d’appeller le service technique de Saniflo
au numéro suivant : 800-571-8191 (USA) or 800-363-5874 (CDN).
The user should retain these instructions for future reference • A lire attentivement et à conserver à titre d’information
This product must be installed in strict accordance whith local plumbing codes.
Product should be installed by a qualified technician.
Le produit doit être installé dans le respect des réglements sanitaires locaux.
Le produit doit être installé par un technicien qualifié.
INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION ET DE MAINTENANCE
2
3
B
x 2
C
x 2
20 Ft
(6m )
A
X
1
D
x 3
F
x 4
E
x 2
G
x 1
11
7
/
8
" (301mm)
11" (280.5mm)
10" (254mm)
7
1
/
2
" (190mm)
2
1
/
4
" (56mm)
7" (179mm)
Y
12 Ft (4 m)
9 Ft (3 m)
6 Ft (2 m)
3 Ft (1 m)
1
%
1
%
1
%
1
%
1
%
1
%
max 15 Ft (4.5 m)
150 ft (50 m)
120 ft (40 m)
90 ft (30 m)
60 ft (20 m)
30 ft (10 m)
OK
0 50 100 150 200 250 300 350
0
1
2
3
4
5
0 10 20 30 40 50 60 70 80
Hauteur (pieds) •Vertical Distance (Feet)
Débit (gallons/heure) • Flow rate (gallons/hour)
Hauteur (mètres) • Vertical Distance (meters)
Débit (l/heure) • Flow rate (liters/hour)
0
2
4
6
8
10
12
14
16
D
D
D
X
7e
7
7b
1
2
7f
X
Y
C
A
B
1
2
3
7c
A
7a
F
E
F
G
1
3
2
15Ft (4.5m) max
SANICONDENS
®
Best
115 V - 60 Hz - 60 W
IP20 -
1.2 A
8
4
1
CAUTION
SANICONDENS
®
BEST is a pump for lifting condensate water from
an air conditioning system, a condensation boiler or from refrige-
ration units.
The pump starts automatically and has a high level of
performance, safety and reliability provided that all the
installation and maintenance instructions described in this notice
are strictly followed.
Please take particular note of the information marked by :
«
» Indication that a risk of electrical origin exists,
«
» Instructions for use only by qualified professionals.
OPERATING PRINCIPLE
SANICONDENS
®
BEST contains a pump. The tank of the
SANICONDENS
®
BEST is fitted with a float which controls the
operation of the motor. When the condensate enters the tank, the
pump starts up.
2
SPARE PARTS:
see fig.2
3
DIMENSIONS:
see fig.3
4
SANICONDENS
BEST
®
AREA OF APPLICATION AND
TECHNICAL DATA
Application
Air conditioning systems, boilers,
refrigeration units
Type condens best
Max. vertical pumping 15 Ft (4.5 m)
Maximum flow rate (gal / hour) 86 (326 l/h)
Min. pH 2.5
Voltage 110-115 V
Frequency 60 Hz
Power rating 60 W
Current consumption 1.2 A
Electrical class I
Protection index IP20
Sound level < 45 dBA
Maximum allowable temperature 160° F (70° C)
S3 15% (1min30 ON, 8min30 OFF)
Net weight 8 lbs
Tank volume 2 liters
Supply cable 6 Ft (2 m)
Discharge hose 20 Ft (6 m)
Alarm cable (3 core) 6 Ft (2 m)
Wall fastening Yes
CAUTION:
All applications other than those described in this notice are pro-
hibited.
5
PERFORMANCE CURVES:
see fig.5
6
VERTICAL PUMPING/HORIZONTAL PUMPING:
see fig.6
7
INSTALLATION
SANICONDENS
®
BEST may be mounted on a wall by using the
mounting tabs on the tank..
The unit should be easy to access for testing and
maintenance.
The unit must be installed leveled. Adjust the
installation using a level before mounting the unit.
Make sure that the equipment is protected from damp while ins-
talling it.
7b
CONNECTION AT THE COVER INLET
The unit has 4 inlets 1 in diameter (2 on each side - see fig.
7b
).
To connect the water to be drained off, connect the water inlet to
one of the inlets and close o any unused inlets with the plug D.
If necessary, use the adapter
X
(3/4”, 1-1/4”, 1-1/2” in diameter).
ELECTRICAL CONNECTION
1. The electrical installation should be carried out by a qualified per-
son. The unit should be connected to a fully grounded electrical
supply. The SANICONDENS
®
BEST
requires a 120V single phase AC
60 Hz supply.
7e
ALARM
SANICONDENS
®
BEST is fitted with a detection system
that can trigger an alarm if the water level rises too high
(audible or visual alarm, 1.5V to 120V), see diagram
7e
:
1
. Brown wire: shared wire
2
. Black wire: normally off
3
. Blue wire: normally on
To fit the alarm, connect the blue and brown wires
of the alarm to the respective terminals on the
SANICONDENS
®
BEST.
US CDN
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
The unit has its own neutralization system that can be used to
increase the pH of the acid water from the condensing boiler
Mount the handle E using the 2 screws F. Add the contents of
the bag of neutralizing pellets G into the drawer
7a
7c
CONNECTING TO THE DISCHARGE HOSE
The SANICONDENS
®
BEST discharge pipe must be connected to the
flexible hose
A
(supplied : length 20 Ft). This hose should be used
to form the vertical section of the discharge pipe.
Place the flexible hose onto the non-return valve of the
SANICONDENS
®
BEST(see diagram
7c
)
.
Position the flexible hose in the most vertical position
possible to avoid it kinking.
It is advisable to make a smooth bend to avoid the hose from
kinking.
The discharge vinyl tubing (included) can be connected to a
PVC line large in diameter by using the plastic reducer
Y
that
is provided with the system.
As shown on the fig.
7f
, the plastic fitting connects to the
end of the 3/8” vinyl tubing at the top and it increases the
diameter to ease the connection to a PVC line. (Reducer is
3/8” barbed x 3/4» male end)
The SANICONDENS
®
BEST is fitted with a non-return valve to
prevent re-activation.
5
8
STANDARDS
This model is eligible to bear the CSA mark shown with
adjacent indicators “C” and “US”. The “C” and “US”
indicators adjacent to the CSA mark signify that the product
has been tested according to the applicable CSA (CDN)
and ANSI/UL standards for use in Canada and the USA.
This includes products eligible bear the designation NTRL.
NTRL (Nationally Recognized Testing Laboratory) is a desi-
gnation awarded by the American Occupational Safety and
Health Administration (OSHA) to laboratories authorized to
award the certification according to American standards.
11
LIMITED WARRANTY
This SFA appliance bears a 3 year warranty starting from
the date of purchase, subject to proper installation and use,
in compliance set out in this notice.
Warranty issues will be handled by the Technical Department
and will be subject to correct installation and usage.
If a replacement is to be issued, this will be only extended
to the first 180 days starting from the date of purchase
and will need to be approved by one of our company’s
representative. Warranty repairs will apply after such date
up to the warranty’s date of conclusion.
Plumber’s invoices for any type of repair, disconnection and
reconnection are not covered by the warranty and are the
end user’s responsibility. In no event shall the company be
liable for any special, incidental or consequential damage,
loss or injury of whatsoever nature or kind arising from or in
connection with the product or any component thereof.
10
TROUBLESHOOTING
Disconnect the electrical supply before carrying out any work.
FAULT DETECTED
• The pump does not start
The pump does not lift
PROBABLE CAUSES
The pump is not
connected to the power supply
The locking pin has not been
removed.
• The unit is not level.
Power cut
• Float blocked
Condensates inlet pipe blocked
Non-return valve blocked
Discharge pipe blocked
ACTION NEEDED
• Plug in the unit.
• Remove the locking pin.
• Please check the unit with a
spirit level.
Check the mains voltage.
Clean the SANICONDENS
®
tank
.
Clean the SANICONDENS
®
inlet pipe
.
Clean the valve.
Clean the discharge pipe
.
INSTRUCTIONS RESERVED SOLELY FOR
QUALIFIED PROFESSIONALS
OPTIONAL: if you connect the brown and black wires to the
control relays on your boiler, it will be switched off if the water
level rises too high in the unit.
ATTENTION: The maximum current admissible for our detection
system is 0.5A.
To protect the electrical components in the SANICONDENS
®
BEST
once the alarm has been triggered, any water continuing to fill
the tank comes out through the overflow outlets in the cover.
BEFORE TURNING THE DEVICE ON, MAKE SURE YOU
REMOVE THE PROTECTIVE LOCKING PIN FROM THE
REAR OF THE DEVICE
7f
EXAMPLE OF AN INSTALLATION OF
A SANICONDENS
®
BEST: see fig.
7f
9
DISASSEMBLY
If a breakdown occurs, any service on the unit should be carried
out by a qualified technician. In particular the
replacement of the power cable.
Disconnect the electrical supply before carrying out work
on the unit.
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
7e
Neutralisation drawer is blocked
Clean the drawer, replace the
pellets
SANICONDENS
®
Best
LIMITED WARRANTY
Warranty period two-year from date of purchase
Subject to the conditions listed below, SFA-SANIFLO INC. (hereinafter called the «Company»)
guarantees to repair or at its option replace the product or any component thereof, which, in the
opinion of the Company, is faulty or below standard as a result of inferior workmanship or materials.
CONDITIONS
The conditions of this guarantee are:
1.The product must not have been subjected to misuse, neglect, accident or damaging
products, in accordance with the paragraph «USAGE» of these Installation Instructions.
2.The product must have been connected to a single phase 120V, 60Hz electrical supply.
3.The alleged fault or defect must be notified to the company, within the warranty period.
PART OR PRODUCT EXCHANGE
The product will be exchange, free of charge, at the original resellers place of business only, upon
the followings conditions being fullfilled:
1 The customer need a «return authorization» number from the company to authorize and
validate the exchange.
2 The customer must supply a copy of their invoice to validate the request for an exchange.
LIMITATIONS
1.Fill and flush mechanism are guaranteed as per OEM warranty only.
2.Cost of disconnection and reconnection (ie labor charges) are not covered by the warranty
and are end-users responsability.
3.Cost of mail or freight when a part or parts of the system have to be repaired at the
company are not covered by this warranty.
4.In no event shall the company be reliable for any special, incidental or consequential
damage, loss, or injury of whatsoever nature or kind arising from or in connection with the
product or any component thereof.
5.The guarantee is transferable only when the product remains at the same premises as
where it was installed initialy.
Except as set forth in this Limited Warranty, the company disclaims all other warranties, express or
implied, with respect to the product or any component thereof including, but not limited to, all implied
warranties for merchantability and fitness for a particular purpose
For service or for further inquiries, please call or contact any of the following addresses:
United States Canada
SFA-SANIFLO INC. SFA-SANIFLO INC.
105 Newfield Avenue, Suite A
1-685 Speedvale Avenue West
Edison, NJ 08837
Guelph ON
N1K 1E6
Toll Free: 1-800-571-8191 Toll Free: 1-800-363-5874 English
Toll Free: 1-800-877-8538 French
Telephone: 1-732-225-6070 Telephone: 1-519-824-1134
Fax: 1-732-225-6072 Fax: 1-519-824-1143