Electrolux EFDE317TIW Manuel utilisateur

Catégorie
Sèche-linge électriques
Taper
Manuel utilisateur
EN FRONT LOAD DRYER
FR SÉCHEUSE Á CHARGEMENT FRONTAL
ES SECADORA DE CARGA FRONTAL
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
INSTRUCCIONES DE INSTALACIÓN
A11199801 January 2018
2
Important Safety Instructions
©2017 Electrolux Major Appliances All rights reserved.
WARNING
For your safety, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury or loss of life. DO NOT
store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Safety Precautions
DO NOT attempt to install or operate
your unit until you have read the safety
precautions in this manual. Safety items
throughout this manual are labeled with a
Danger, Warning, or Caution based on the
risk type.
Definitions
This is the safety alert symbol. It is
used to alert you to potential personal injury
hazards. Obey all safety messages that
follow this symbol to avoid possible injury
or death.
IMPORTANT
Indicates installation, operation, or main-
tenance information which is important
but not hazard-related.
CAUTION
CAUTION indicates a potentially hazard-
ous situation which, if not avoided, may
result in minor or moderate injury.
WARNING
WARNING indicates a potentially hazard-
ous situation which, if not avoided, could
result in death or serious injury.
DANGER
DANGER indicates an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Table of Contents
Important Safety Instructions ................2
Installation Requirements ...................... 4
Installation Instructions .......................12
Reversing Door ...................................19
Options ..............................................21
3
Important Safety Instructions
WARNING
RISK OF FIRE
Read all the following instructions before installing and using this appliance.
Destroy the carton and plastic bags after the laundry center is unpacked. Children
might use them to play. Cartons covered with rugs, bedspreads, or plastic sheets
can become airtight chambers causing suffocation. Place all materials in a garbage
container or make materials inaccessible to children.
Clothes dryer installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Install the clothes dryer according to the manufacturer’s instructions and local codes.
The electrical service to the dryer must conform with local codes and ordinances
and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada,
the Canadian Electrical Code CSA C22.1 part 1.
The gas service to the dryer must conform with local codes and ordinances and the
latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada,
the Natural Gas and Propane Installation Code, CSA B149.1. An individual manual
shutoff valve must be installed within 6 ft (1.83 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The dryer is designed under ANSI Z21.5.1/CSA 7.1 or UL 2158 - CAN/CSA C22.2
No. 112 (latest editions) for HOME USE only. This dryer is not recommended for
commercial applications such as restaurants, beauty salons, etc.
DO NOT install a clothes dryer with flexible plastic or flexible foil venting
material. Flexible venting materials are known to collapse, be easily crushed
and trap lint. These conditions will obstruct clothes dryer airflow and in-
crease the risk of fire.
DO NOT stack a dryer on top of washer already installed on pedestal. DO NOT stack
washer on top of dryer. DO NOT stack washer on top of another washer.
The instructions in this manual and all other literature included with this dryer are not
meant to cover every possible condition and situation that may occur. Good safe
practice and caution MUST be applied when installing, operating and maintaining
any appliance.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
4
Installation Requirements
Tools and materials needed for installation:
Please read and save
this guide
Thank you for choosing Electrolux, the
premium brand in home appliances. These
Installation Instructions are part of our
commitment to customer satisfaction and
product quality throughout the life of your
new appliance.
Questions?
Toll-free telephone and online support:
U.S.
1-877-4ELECTROLUX (1-877-435-3287)
www.electroluxappliances.com
Canada
1-800-265-8352
www.electroluxappliances.ca
Exhaust Venting
Free-flowing, clear of lint buildup
4 inch (102 mm) rigid or semi-rigid
ducting of minimal length and turns
NO foil or plastic venting material
Approved vent hood exhausted to
outdoors
Leveling
Dryer is level, side-to-side and front-
to-back
Cabinet is sitting solid on all corners
Gas Supply (Gas Dryer)
Manual shutoff valve present in
supply
All connections sealed with approved
sealer and wrench tight
Conversion kit for LP GAS system
Gas supply turned on
No leaks present at all connections
- check with soapy water, NEVER
check with flame
240v Electric Supply (Electric
Dryer)
Approved NEMA 10-30 or 14-30
service cord with all screws tight on
terminal block
Approved strain relief installed
Terminal access cover installed
before initial operation
Door Reversal
Follow detailed instructions in this
guide
Test hinge and latch for function
Electrical Power
House power turned on
Dryer plugged in
Final Checks
Installation Instructions and Use and
Care Guide read thoroughly
Door latches and drum tumbles
when cycle starts
Registration card sent in
Installation Checklist
5
Electrical system
requirements
Electrical Requirements For
Electric Dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or
circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT
operate washer and dryer on same circuit.
POWER SUPPLY - 3-wire or 4-wire,
120/240 volt, single phase, 60 Hz, Alter-
nating Current.
NOTE
Because of potentially inconsistent voltage
capabilities, the use of this dryer with power
created by gas powered generators, solar
powered generators, wind powered gener-
ators or any other generator other than the
local utility company is not recommended.
NOTE
A 120/208 volt, single phase, 60 Hz,
Alternating Current supply may be used on
dryers marked for use on rating plate.
IMPORTANT
Dryer is internally grounded to neutral
unless it was manufactured for sale in
Canada.
Only a 4-conductor cord shall be used
when the appliance is installed in a loca-
tion where grounding through the neu-
tral conductor is prohibited. Grounding
through the neutral link is prohibited for: (1)
new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4)
areas where local codes DO NOT permit
grounding through the neutral.
WARNING
FIRE HAZARD
• Failure to follow safety warnings
exactly could result in serious injury,
death, or property damage.
DO NOT install a booster fan in dryer
exhaust duct.
• Install all clothes dryers in accor-
dance with the installation instruc-
tions in this manual.
Adjustable
pliers
4 inch, rigid metal or
semi-rigid metal exhaust duct work
Adjustable
wrench
Metal foil
tape (not
duct tape)
External
vent hood
or
Carpenter’s
level
Optional
universal
accessory
wrench
Pipe wrench
for gas
supply
gas line
shutoff valve
(gas dryer)
or
LP-resistant
thread tape
(for natural
gas or
LP supply)
½” NPT
union flare
adapters (x2)
and flexible
gas supply line
(gas dryer)
3-wire or 4-wire
240 volt cord kit
(electric dryer)
Phillips,
straight, &
square bit
screwdrivers
4 in.
(10.2 cm)
clamp
Installation Requirements
Tools and materials needed for
installation:
6
1. Installation MUST conform with local
codes, or in the absence of local
codes, with the National Fuel Gas
Code, ANSI Z223.1 (latest edition).
Installation Requirements
3-WIRE POWER SUPPLY CORD
(not supplied)
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the dryer
is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type
SRDT rated at 240 volt AC minimum, 30
amp, with 3 open end spade lug con-
nectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNEC-
TIONS FOR A 3-WIRE SYSTEM.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the dryer
is in the installed position.
4-WIRE POWER SUPPLY CORD
(not supplied)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type
SRDT or DRT (as required) rated at 240
volt AC minimum, 30 amp, with 4 open
end spade lug connectors with upturned
ends or closed loop connectors and
marked for use with clothes dryers. For
4-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A
4-WIRE SYSTEM.
Electrical Requirements For Gas
Dryer:
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused
with 15 amp. time delay fuse or circuit
breaker.
POWER SUPPLY - 2-wire, with ground,
120 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped
with a 120 volt 3-wire power cord.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).
Gas supply requirements
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
7
Installation Requirements
Exhaust system
requirements
If your present system is made up of
plastic duct or metal foil duct, replace
it with a rigid or semi-rigid metal duct.
Ensure the present duct is free of any
lint prior to installing dryer duct.
Use only 4 inch (102 mm) diameter
(minimum) rigid or flexible metal duct and
approved vent hood which has a swing-
out damper(s) that open when the dryer
is in operation. When the dryer stops, the
dampers automatically close to prevent
drafts and the entrance of insects and
rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5
cm) clearance between the vent hood and
the ground or any other obstruction.
Correct Incorrect
Correct Incorrect
The following are specific require-
ments for proper and safe operation of
your dryer.
WARNING
FIRE HAZARD
Failure to follow these instructions can cre-
ate excessive drying times and fire hazards.
WARNING
FIRE HAZARD
DO NOT install a clothes dryer with flex-
ible plastic or metal foil venting materials.
Flexible venting materials are known to
collapse, be easily crushed and trap lint.
These conditions will obstruct clothes
dryer airflow and increase the risk of fire.
WARNING
FIRE HAZARD
• Failure to follow safety warnings ex-
actly could result in serious injury,
death, or property damage.
• DO NOT install a booster fan in dryer
exhaust duct.
• Install all clothes dryers in accor-
dance with the installation instruc-
tions in this manual.
Gas supply requirements, con-
tinued
2. The gas supply line should be 1/2 inch
(1.27 cm) pipe.
3. If codes allow, flexible metal tubing
may be used to connect your dryer to
the gas supply line. The tubing MUST
be constructed of stainless steel or
plastic-coated brass.
4. The gas supply line MUST have an
individual shutoff valve installed in ac-
cordance with the B149.1, Natural Gas
and Propane Installation Code.
5. A 1/8 inch (0.32 cm) N.P.T. plugged
tapping, accessible for test gauge con-
nection, MUST be installed immediately
upstream of the gas supply connection
to the dryer.
6. The dryer MUST be disconnected from
the gas supply piping system during
any pressure testing of the gas supply
piping system at test pressures in
excess of 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the
gas supply piping system during any
pressure testing of the gas supply pip-
ing system at test pressures equal to or
less than 1/2 psig (3.45 kPa).
8. Connections for the gas supply must
comply with the Standard for Connec-
tors for Gas Appliances, ANSI Z21.24/
CSA 6.10.
8
Installation Requirements
The dryer must be connected to an
exhaust outdoors. Regularly inspect the
outdoor exhaust opening and remove any
accumulation of lint around the outdoor ex-
haust opening and in the surrounding area.
Exhaust Direction
Directional exhausting can be accom-
plished by installing a quick-turn 90° dryer
vent elbow directly to exhaust outlet of
dryer. Dryer vent elbows are available
through your local parts distributor or
hardware store.
Exhaust system requirements, continued
Number of 90° turns
MAXIMUM LENGTH
of 4” (102 mm) Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
4”
(10.2 cm) louvered
2.5”
(6.35 cm)
0 125 ft. (38 m) 110 ft. (33.5 m)
1 115 ft. (35 m) 100 ft. (30.5 m)
2 105 ft. (32 m) 90 ft. (27.5 m)
3 95 ft. (29 m) 80 ft. (24.5 m)
4 85 ft. (26 m) 70 ft. (21.5 m)
See also CLEARANCE
REQUIREMENTS.
WARNING
FIRE HAZARD
A clothes dryer must be exhausted
outdoors. DO NOT exhaust dryer into
a chimney, a wall, a ceiling, an attic, a
crawl space or any concealed space of
a building. A clothes dryer produces
combustible lint. If the dryer is not ex-
hausted outdoors, some fine lint will be
expelled into the laundry area. An accu-
mulation of lint in any area of the home
can create a health and fire hazard.
WARNING
FIRE HAZARD
• DO NOT allow combustible materi-
als (for example: clothing, draperies/
curtains, paper) to come in contact
with exhaust system. The dryer MUST
NOT be exhausted into a chimney,
a wall, a ceiling, or any concealed
space of a building which can accu-
mulate lint, resulting in a fire hazard.
DO NOT screen the exhaust ends of
the vent system, or use any screws,
rivets or other fasteners that extend
into the duct to assemble the exhaust
system. Lint can become caught in
the screen, on the screws or rivets,
clogging the duct work and creating a
fire hazard as well as increasing drying
times. Use an approved vent hood to
terminate the duct outdoors, and seal
all joints with metal foil tape. All male
duct pipe fittings MUST be installed
downstream with the flow of air.
WARNING
Exceeding the length of duct pipe
or number of elbows allowed in the
“MAXIMUM LENGTH” charts can cause an
accumulation of lint in the exhaust system.
Plugging the system could create a fire
hazard, as well as increase drying times.
WARNING
FIRE HAZARD
• DO NOT install flexible plastic or
flexible foil venting material.
• DO NOT exceed 8 ft. (2.4 m)
duct length if installing semi-
rigid venting.
NOTE
Use of 90° quick-
turn elbow required to
meet minimum installation depth.
9
Installation Requirements
In installations where the exhaust system
is not described in the charts, the following
method must be used to determine if the
exhaust system is acceptable:
Exhaust system requirements, continued
Correct Incorrect
Install male fittings in correct direction:
1. Connect an inclined or digital manom-
eter between the dryer and the point
the exhaust connects to the dryer.
2. Set the dryer timer and temperature to
air fluff (cool down) and start the dryer.
3. Read the measurement on the ma-
nometer.
4. The system back pressure MUST
NOT be higher than 1.0 inch of water
column. If the system back pressure is
less than 1.0 inch of water column, the
system is acceptable. If the manometer
reading is higher than 1.0 inch of water
column, the system is too restrictive
and the installation is unacceptable.
Although vertical orientation of the exhaust
system is acceptable, certain extenuating
circumstances could affect the perfor-
mance of the dryer:
Only the rigid metal duct work should
be used.
Venting vertically through a roof may ex-
pose the exhaust system to down drafts
causing an increase in vent restriction.
Running the exhaust system through an
uninsulated area may cause condensa-
tion and faster accumulation of lint.
Compression or crimping of the exhaust
system will cause an increase in vent
restriction.
The exhaust system should be
inspected and cleaned a minimum of
every 18 months with normal usage.
The more the dryer is used, the more
often you should check the exhaust sys-
tem and vent hood for proper operation
and that it is free of obstructions.
Manufactured or mobile home installation
1. Installation MUST conform to current
Manufactured Home Construction &
Safety Standard, Title 24 CFR, Part
32-80 (formerly the Federal Standard
for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or
Standard CAN/CSAZ240 MH.
2. Dryer MUST be exhausted outside
(outdoors, not beneath the mobile
home) using metal ducting that will not
support combustion. Metal ducting
must be 4 inches (10.16 cm) in diam-
eter with no obstructions. Rigid metal
duct is preferred.
3. If dryer is exhausted through the floor
and area beneath the mobile home is
enclosed, the exhaust system MUST
terminate outside the enclosure with
the termination securely fastened to a
non-combustible portion of the mobile
home structure.
4. Refer to previous sections in this guide
for other important exhaust venting
system requirements.
5. When installing a gas dryer into a mo-
bile home, a provision must be made
for outside make up air. This provision
is to be not less than twice the area of
the dryer exhaust outlet.
6. Installer MUST anchor this (1) dryer
or (2) dryer mounted on pedestal to
the floor with approved Mobile Home
Installation Kit - P/N 137067200.
WARNING
FIRE HAZARD
DO NOT install the dryer where gasoline
or other flammables are kept or stored. If
the dryer is installed in a garage, it must
be a minimum of 18 inches (45.7 cm)
above the floor. Failure to do so can re-
sult in death, explosion, fire or burns.
10
Installation Requirements
MIN INSTALLATION CLEARANCES -
Inches (cm)
Sides Rear Top Front
Alcove 0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
Under-
Counter
0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
Closet 0” (0 cm) 0” (0 cm)* 0” (0 cm)
1”
(2.5 cm)
Clearance requirements
60 sq. in.
(387.1cm²)
3"
(7.6cm)
60 sq. in.
(387.1cm²)
3"
(7.6cm)
Installation In A Recess Or
Closet
1. A dryer installed in a bedroom,
bathroom, recess or closet, MUST be
exhausted outdoors.
2. No other fuel burning appliance shall
be installed in the same closet as the
gas dryer.
3. Your dryer needs the space around it
for proper ventilation.
DO NOT install your dryer in a closet
with a solid door.
4. Closet door ventilation required: A
minimum of 120 square inches (774.2
cm²) of opening, equally divided at the
top and bottom of the door, is required.
Openings should be located 3 inches
(7.6 cm) from bottom and top of door.
Openings are required to be unobstruct-
ed when a door is installed. A louvered
door with equivalent air openings for the
full length of the door is acceptable.
closet door
•F
or other than straight back venting, a quick-
turn 90° dryer vent elbow must be installed to
achieve 0” (0 cm) installation.
0"
(0 cm)
0"
(0 cm)
1"
(2.5 cm)
0"
(0 cm)
NOTE
To achieve an installation with 0” (0
cm) clearance for the back of the dryer
(for other than straight back venting), a
quick-turn 90° dryer vent elbow must be
installed as described previously in this
manual.
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water
or outside weather conditions.
2. In an area where it will come in con-
tact with curtains, drapes, or anything
that will obstruct the flow of combus-
tion and ventilation air.
3. On carpet. Floor MUST be solid with
a maximum slope of 1 inch (2.5 cm).
11
Installation Requirements
Dryer dimensions
* Connection of water inlet hose on steam dryer adds 3/4 in. (2 cm) to installation depth.
1
Power supply cord length on gas dryer or electric Canadian dryer approximately 60
inches (152.5 cm).
2
Drain hose length on washer approximately 59 inches (150 cm).
3
Power supply cord length on washer approximately 60 inches (152.5 cm).
electrical
supply on
rear of unit
1
gas supply
pipe on rear
of gas unit
centerline
height of
rear vent
53.2” (135 cm)*
to clear open door
31.6” (80 cm)*
to front of closed door
27.0”
(68.5 cm)
floor line
floor line
freestand dryer
on floor
dryer mounted on
optional pedestal
38.0”
(96.5 cm)
53.25”
(135.5 cm)
17.0”
(43 cm)
19.0”
(48 cm)
3.7”
(9.5
1.5”
(4 cm)
3.75”
(9.5 cm)
electrical
supply on
rear of unit
1
gas supply
pipe on rear
of gas unit
centerline
height for
rear vent
53.5” (136 cm)*
to clear open door
32.0” (81.25 cm)*
to front of closed door
75.75”
(192.5 cm)
41.0”
(105 cm)
39.0”
(99 cm)
water supply
connection on
rear of unit
drain hose on
rear of unit
2
power cord on
rear of unit
3
floor line
approved stacking
kit (STACKIT7X)
required for
stacked installation
13.5”
(34.5 cm)
to center of
rear vent
12
Installation Instructions
Electrical installation
The following are specific requirements for
proper and safe electrical installation of
your dryer. Failure to follow these instruc-
tions can create electrical shock and/or a
fire hazard.
Grounding requirements -
Electric dryer (USA)
For a grounded, cord-connected
dryer:
1. The dryer MUST be grounded. In the
event of a malfunction or breakdown,
grounding will reduce the risk of electri-
cal shock by providing a path of least
resistance for electrical current.
2. After you purchase and install a 3 wire
or 4 wire power supply cord having an
equipment-grounding conductor and a
grounding plug that matches your wir-
ing system, the plug MUST be plugged
into an appropriate, copper wired
receptacle that is properly installed and
grounded in accordance with all local
codes and ordinances. If in doubt, call
a licensed electrician.
3. DO NOT modify the plug you’ve in-
stalled on this appliance. If it will not fit
the outlet, have a proper outlet installed
by a qualified electrician.
For a permanently connected dryer:
The dryer MUST be connected to a
grounded metal, permanent wiring system;
or an equipment grounding conductor
must be run with the circuit conductors
and connected to the equipment-ground-
ing terminal or lead on the appliance.
WARNING
ELECTRICAL SHOCK HAZARD
This appliance MUST be properly
grounded. Electrical shock can result
if the dryer is not properly grounded.
Follow the instructions in this manual
for proper grounding.
DO NOT use an extension cord with
this dryer. Some extension cords
are not designed to withstand the
amounts of electrical current this dryer
utilizes and can melt, creating electri-
cal shock and/or fire hazard. Locate
the dryer within reach of the recep-
tacle for the length power cord to be
purchased, allowing some slack in
the cord. Refer to the pre-installation
requirements in this manual for the
proper power cord to be purchased.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
WARNING
ELECTRICAL SHOCK HAZARD
• A U.L.-approved strain relief must be
installed onto power cord. If the strain
relief is not attached, the cord can
be pulled out of the dryer and can
be cut by any movement of the cord,
resulting in electrical shock.
• DO NOT use an aluminum wired
receptacle with a copper wired
power cord and plug (or vice versa).
A chemical reaction occurs between
copper and aluminum and can cause
electrical shorts. The proper wiring
and receptacle is a copper wired
power cord with a copper wired
receptacle.
NOTE
Dryers operating on 208 volt power supply
will have longer drying times than dryers
operating on 240 volt power supply.
13
Installation Instructions
Grounding requirements -
Electric dryer (Canada)
Grounding requirements -
Gas dryer (USA and Canada)
For a grounded, cord-connected
dryer:
1. The dryer MUST be grounded. In the
event of a malfunction or breakdown,
grounding will reduce the risk of electri-
cal shock by providing a path of least
resistance for electrical current.
2. Since your dryer is equipped with
a power supply cord having an
equipment-grounding conductor and
a grounding plug, the plug must be
plugged into an appropriate outlet that
is properly installed and grounded in
accordance with all local codes and
ordinances. If in doubt, call a licensed
electrician.
3. DO NOT modify the plug provided with
this appliance. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
1. The dryer is equipped with a three-
prong (grounding) plug for your protec-
tion against shock hazard and should
be plugged directly into a properly
grounded three-prong receptacle.
2. The plug must be plugged into an
appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances. If
in doubt, call a licensed electrician.
3. DO NOT modify the plug provided with
this appliance. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
14
Electrical connection
(non-Canada) - 3 wire cord
Installation Instructions
1. Turn off power supply to outlet.
2. Remove the screw securing the ter-
minal block access cover in the lower
corner on the back of the dryer.
3. Install a UL-approved strain relief
according to the power cord/strain
relief manufacturer’s instructions in the
power cord entry hole below the ac-
cess panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-ap-
proved, 30 amp. power cord, NEMA
10-30 type SRDT, through the strain
relief.
5. Attach the power cord neutral (center
wire) conductor to the SILVER colored
center terminal on the terminal block.
Tighten the screw securely.
6. Attach the remaining two power cord
outer conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.
3-wire receptacle
(NEMA type 10-30R)
Access
Cover Screw
Terminal
Block
Line 2
(BRASS Terminal)
Neutral
(SILVER Terminal)
Line 1
(BRASS Terminal)
Internal Ground
(GREEN Screw)
Install UL-Approved
Strain Relief Here
Terminal Screw
Recovery Slot
Neutral
(center wire)
30 AMP
NEMA 10-30
7. Follow manufacturer’s guidelines for
firmly securing the strain relief and
power cord.
8. Reinstall the terminal block cover.
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
NOTE
If a terminal screw falls during cord
installation, it can be retrieved in the
terminal screw recovery slot below the
access panel.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source be-
fore servicing could result in personal
injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp
wiring/conductor at connections.
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the
internal ground from the center terminal
back to the GREEN screw next to the
terminal block.
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
15
Installation Instructions
Electrical connection
(non-Canada) - 4 wire cord
Access
Cover Screw
Terminal
Block
Line 2
(BRASS Terminal)
Neutral
(SILVER Terminal)
Line 1
(BRASS Terminal)
Internal Ground
(GREEN Screw)
Install UL-Approved
Strain Relief Here
Terminal Screw
Recovery Slot
4-wire receptacle
(NEMA type 14-30R)
1. Turn off power supply to outlet.
2. Remove the screw securing the ter-
minal block access cover in the lower
corner on the back of the dryer.
3. Install a UL-approved strain relief
according to the power cord/strain
relief manufacturer’s instructions in the
power cord entry hole below the ac-
cess panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-ap-
proved, 30 amp. power cord, NEMA
14-30 type DRT or SRDT, through the
strain relief.
5. Disconnect the internal (WHITE) dryer
harness ground wire from the (GREEN)
ground screw next to terminal block.
6. Attach the ground (GREEN) power
cord wire to the cabinet with the
ground (GREEN) screw. Tighten the
screw securely.
7. Move the internal dryer harness ground
(WHITE) wire to the terminal block and
attach it along with the neutral (WHITE)
power cord wire conductor to center,
SILVER colored terminal on the terminal
block. Tighten the screw securely.
8. Attach the RED and BLACK power
cord conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.
Neutral
(WHITE
wire)
30 AMP
NEMA 14-30
Ground
(GREEN
wire)
9. Follow manufacturer’s guidelines for
firmly securing the strain relief and
power cord.
10. Reinstall the terminal block cover.
Move internal ground (WHITE)
wire to neutral (SILVER)
terminal for 4-wire system.
Neutral
terminal
GREEN
ground screw
BLACK or
RED power wire
BLACK
or RED
power wire
GREEN
ground wire
WHITE
neutral wire
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source be-
fore servicing could result in personal
injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp
wiring/conductor at connections.
NOTE
If a terminal screw falls during cord instal-
lation, it can be retrieved in the terminal
screw recovery slot below the access
panel.
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
16
Installation Instructions
Gas connection
1. Remove the shipping cap from gas
pipe at the rear of the dryer.
2. Connect a 1/2 inch (1.27 cm) I.D.
semi-rigid or approved pipe from gas
supply line to the 3/8 inch (0.96 cm)
pipe located on the back of the dryer.
Use a 1/2 inch to 3/8 inch (1.27 cm to
0.96 cm) reducer for the connection.
Apply an approved thread sealer that is
resistant to the corrosive action of lique-
fied gases on all pipe connections.
3. Open the shutoff valve in the gas sup-
ply line to allow gas to flow through
the pipe. Wait a few minutes for gas to
move through the gas line.
All connections must be wrench-tightened
Flare
Union
Flare
Union
Manual
Shutoff
Valve
Closed
Open
Flexible
Connector
GAS FLOW
Inlet Pipe on
Back of Dryer
Nipple
Shutoff Valve - Open position
to dryer
from gas supply
4. Check for gas system leaks with a ma-
nometer. If a manometer is not avail-
able, test all connections by brushing
on a soapy water solution.
IMPORTANT
DO NOT connect the dryer to L.P. gas
service without converting the gas valve.
An L.P. conversion kit must be installed
by a qualified gas technician.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open
flame.
IMPORTANT
Installation to the gas service must follow
local codes and ordinances and the lat-
est edition of the National Fuel Gas Code
ANSI Z223.1/NFPA 54 or in Canada,
CSA B149.1.
IMPORTANT
The supply line must be equipped with
an approved manual shutoff valve. This
valve should be located in the same room
as the dryer and should be in a location
that allows ease of opening and closing.
DO NOT block access to the gas shutoff
valve.
Water connection
(Steam Model only)
Water Supply Requirements
Cold water faucet MUST be installed
within 42 inches (107 cm) of your dryer’s
water inlet. The faucet MUST be 3/4
inch (1.9 cm) with threading for laundry
hose connection. Water pressure MUST
be between 20 and 120 psi. Your water
department can advise you of your water
pressure.
1. Turn off COLD water supply to washer.
2. Remove COLD inlet hose from COLD
water supply and inspect for rubber
washer.
Replace washer if it is torn or worn
out.
17
Rubber Washers
MUST BE PRESENT
NOTE
If you were able to install the “Y” connec-
tor directly to the COLD water supply,
please skip to step 8.
Installation Instructions
Direct Connection
or with Extension
Water Inlet
on Dryer
Cold Water Supply
Hose to Washer
6. If there is not room to install the “Y”
connector directly, thread the short
extension hose on to the COLD water
supply and snug it by hand; then
tighten it another 2/3 turn with pliers.
7. Thread the “Y” connector to the short
extension hose and snug it by hand;
then tighten it another 2/3 turn with
pliers.
8. Connect the COLD inlet hose for the
washer to the “Y” connector and snug
it by hand; then tighten it another 2/3
turn with pliers.
9. Connect the straight end of the long
hose from the kit to the other outlet
on the “Y” connector and snug it by
hand. Connect the hose’s 90° cou-
pling to the brass water inlet on the
back of the dryer and snug it by hand.
Tighten each connection of the dryer
inlet hose another 2/3 turn with pliers.
Water connection, continued
(Steam Model only)
4. Remove hose kit from dryer drum
and inspect hose couplings for proper
placement of rubber washers.
3. Momentarily turn on COLD supply
and run some water into a bucket or
container to clear any contaminants in
the line.
5. If your installation has room for the
COLD water supply to accept the “Y”
connector directly, thread the “Y” con-
nector to the COLD water supply and
snug it by hand; then tighten it another
2/3 turn with pliers.
10. Turn on the water and check for leaks
at all connections.
Cold Inlet Hose
to Washer
Rubber Washer
Must be Present
and Undamaged
18
Installation Instructions
General installation
1. Connect the exhaust duct to the out-
side exhaust system. Use of a 4” (102
mm) clamp (item A) is recommended to
connect the dryer to the exhaust vent
system. Use metal foil tape to seal all
other joints.
2. Use a carpenter’s level to level your
dryer front-to-back and side-to-side.
3. Use adjustable pliers to adjust the
leveling legs so the dryer is level front-
to-rear and side-to-side, and stable
corner-to-corner.
4. Press down on alternate corners and
sides and feel for the slightest move-
ment. Adjust the appropriate leg(s) so
the dryer sits solidly on the floor on
ALL four legs. Keep the leveling leg
extension at a minimum for best perfor-
mance of the dryer.
5. Plug the power cord into a grounded
outlet.
CAUTION
When discarding or storing your old dry-
er, remove the door.
IMPORTANT
Be sure the power is off at a circuit
breaker/fuse box before plugging the
power cord into an outlet.
6. Turn on the power at the circuit
breaker/fuse box.
7. Read the Use & Care Guide provided
with the dryer. It contains valuable and
helpful information that will save you
time and money.
8. If you have any questions during initial
operation, please review the “Avoid
Service Checklist” in your Use & Care
Guide before calling for service.
9. Place these instructions in a location
near the dryer for future reference.
NOTE
A wiring diagram and technical data
sheet are located under the dryer top
panel.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
19
Screwdriver
with #2
square bit
Reversing Door
Removing Latch and Hole Plugs
1. Open the door.
2. Remove plastic hole plugs and save to
reinstall later. You may have to use a
non-scratching plastic knife if you are
unable to dislodge the plugs manually.
3. Remove both screws from door latch.
Save latch and screws for reinstallation
later.
x2
x2
NOTE
Door reversibility is available on all dryer models.
Plastic knife
Tools needed for reversal:
IMPORTANT
BEFORE YOU REVERSE YOUR DRYER
DOOR:
1. Be sure you have adequate swing area
before reversing door.
2. Gather your tools - including a screw
driver with a #2 square bit and plastic
knife (or small, flat prying tool that won’t
damage paint).
3. Be sure dryer is unplugged from power
source!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing could result in personal injury or
even death.
20
Reversing Door
x2
x2
Reinstalling Door Assembly
1. Rotate the door and hang the upper
hook on the back of the hinge in the
upper hole of the front panel.
Reinstalling Latch and Hole Plugs
1. Install door latch with screws removed
earlier.
Verify Reversed Door Operation
1. Test door for free, smooth swinging
operation and secure latching when
closed.
2. Plug in dryer and close the door. Start
a test cycle: drum should tumble until
door is pulled open or cycle is paused
or canceled.
2. Reinstall and tighten all four screws
removed earlier - two front screws first,
then two side screws.
2. Insert plastic hole plugs removed
earlier.
1
2
3
4
Removing Door Assembly
1. Completely open the door to expose all
four hinge screws.
2. Remove all four hinge screws with #2
square bit driver. Save for reinstalling
later.
x4
3. Grasp the door with both hands and
lift slightly as you pull door and hinge
away from the front panel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Electrolux EFDE317TIW Manuel utilisateur

Catégorie
Sèche-linge électriques
Taper
Manuel utilisateur