Generac PM0143250 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

www.powermate.com 05/15 0070712
Operator Manual
Manuel de l’opérateur Manual del operador
ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO
PM0143250
IMPORTANT - Prière de vous assurer que
les personnes destinées à utiliser cet
appareil ont pris soin d'en lire et d'en
comprendre le mode d'emploi ou les
directives avant de le mettre en marche.
Enregistrer le numéro de série figurant
sur la plaque signalétique du groupe
électrogène:
de série ____________________
IMPORTANT – Please make certain that
persons who are to use this equipment
thoroughly read and understand these
instructions and any additional
instructions provided prior to operation.
Record the serial number as indicated on
your Generators nameplate:
Serial No.______________________
IMPORTANTE - Asegúrese que las
personas que utilizarán este equipo lean
y entiendan completamente estas
instrucciones y cualquier instrucción
adicional proporcionada antes del
funcionamiento.
Registre de serie como se indica en la
placa del nombre de su generador:
No. de serie ___________________
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-800-445-1805
FOR QUESTIONS OR SERVICE
INFORMATION
NO LO DEVUELVA A
LA TIENDA!
¡PRIMERO LLÁMENOS!
LÍNEA DIRECTA DE ATENCIÓN
AL CLIENTE
1-800-445-1805
PARA la INFORMACION de
PREGUNTAS O SERVICIO
NE PAS RETOURNER
AU MAGASIN!
APPELEZ–NOUS D’ABORD!
ASSISTANCE TELEPHONIQUE
A LA CLIENTELE
1-800-445-1805
POUR L'INFORMATION DE
QUESTIONS OU SERVICE
Customer Hotline 1-800-445-1805
2
TABLE OF CONTENTS
TABLE DES MATIERES
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Spark arresting muffler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Determining total wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unpacking the generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Generator features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Portability kit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Before operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ground fault circuit interrupter (GFCI) . . . . . . . . . . . . . . . . . . . . 9
Grounding the generator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Low oil sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
High Altitude Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Starting the unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pre-start preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Starting the engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Applying load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Shutting the generator off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spark plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Oil type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Oil replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Air filter cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fuel shut off valve filter cleaning . . . . . . . . . . . . . . . . . . . . . . . 12
Fuel strainer cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Valve Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Spark arrester screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Brushes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Inspecting the brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Heat shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Engine carburetor icing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Quick starting tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Service and storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Infrequent service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Long term storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Engine troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Engine specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Limited warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parts drawings and parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-45
Emission control warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47
Régles d’opération et de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Silencieux pare-étincelles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Determination de la puissance totale nécessaire . . . . . . . . . . . . . . . 17
Vérifier la tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Déballage de la génératrice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Caractéristiques du groupe electrogene. . . . . . . . . . . . . . . . . . . . . . 20
L’installation de kit de transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Avant de mettre en marche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Protection avec disjoncteur différentiel (GFCI) . . . . . . . . . . . . . 22
Mise en place de l'appareil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lubrification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Le détecteur de bas niveau d'huile . . . . . . . . . . . . . . . . . . . . . . 22
Carburant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Positionnement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Fonctionnement en altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Démarrage de l'appareil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Préparatifs au démarrage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Démarrage du moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Branchement des appareils . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Arrêt de l'appareil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Entretien périodique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Entretien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
La bougie d’allumage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Le type d’huile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Remplacement d’huile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Nettoyage du filtre à air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Nettoyage du filtre du robinet à essence . . . . . . . . . . . . . . . . . 25
Nettoyage de la crépine du réservoir à carburant . . . . . . . . . . 25
Jeu des soupapes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
L'écran pare-étincelles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Les balais . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Inspection des balais . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Écrans de chaleur. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Givrage du carburateur. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Trucs de démarrage rapide . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Usage et entreposage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Usage peu fréquent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Entreposage à long terme . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Depannage du moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Caracteristiques du moteur. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Service clientèle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Garantie limitée. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Schema des pièces et liste des pièces . . . . . . . . . . . . . . . . . . . . 42-45
Reglas de seguridad y de funcionamiento . . . . . . . . . . . . . . . . . . . . 29
Silenciador apagachispas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Como determinar el vataje total . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Requerimiento de voltaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Instalacion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Cómo desembalar el generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Caracteristicas del generador. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Instalacion del juego de transport. . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Antes de la operacion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Protección de interruptor de circuito de falla de
conexión a tierra (GFCI, por sus siglas en inglés). . . . . . . . . . . 35
Puesta a tierra del generador. . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Lubricacion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
El sensor del nivel bajo de aceite . . . . . . . . . . . . . . . . . . . . . . . 36
Combustible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Colocación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Funcionamiento a gran altitud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Arranque de la unidad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Preparacion antes de arrancar. . . . . . . . . . . . . . . . . . . . . . . . . . 37
Arranque del motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Como aplicar una carga . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Apagado del generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Mantenimiento periódico. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Bujia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Tipo de aceite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Cambio del aceite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Cómo limpiar el filtro de aire. . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Cómo limpiar el filtro de la vàlvula de combustible . . . . . . . . . 38
Limpieza del filtro de combustible . . . . . . . . . . . . . . . . . . . . . . 38
Claridad de la valvula . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Protector del parachispas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Escobillas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Revisión de las escobillas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Escudo contra el calor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Congelamiento del carburador del motor . . . . . . . . . . . . . . . . . 39
Instrucciones rápidas para el arranque . . . . . . . . . . . . . . . . . . 39
Servicio y almacenamiento. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Servicio poco frecuente . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Almacenamiento a largo plazo . . . . . . . . . . . . . . . . . . . . . . . . . 39
Deteccion de fallos del motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Especificaciones del motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Informacion de servicio al cliente . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Garantia limitada. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Diagrama de piezas y lista de piezas . . . . . . . . . . . . . . . . . . . . . 42-45
INDICE
English Customer Hotline 1-800-445-1805
3
SAFETY SYMBOL GUIDE
SAFETY INFORMATION
SAFETY INFORMATION
WARNING indicates a
potentially hazardous situation
which, if not avoided, could
result in death or serious injury.
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate personal injury, or
property damage.
WARNING - Failure to follow these instructions
and warnings may result in death, personal
injury, or property damage.
1. Read carefully and understand operator manual
prior to operation of this product. Follow all
warnings and instructions.
2. Know your equipment. Consider the applications,
limitations, and the potential hazards specific to
your unit.
3. Equipment must be placed on a firm, supporting
surface.
4. Load must be kept within rating stated on
generator nameplate. Overloading will damage
the unit or shorten its life.
5. Engine must not be run at excessive speeds.
Operating an engine at excessive speeds increases
the hazard of personal injury.
Do not tamper with parts which may increase
or decrease the governed speed.
6. To prevent accidental starting, always remove the
spark plug or cable from the spark plug before
maintaining the generator or engine.
7. Units with broken or missing parts, or without
protective housing or covers, should never be
operated. Contact your service center for
replacement parts.
8. Units should not be operated or stored in wet or
damp conditions or on highly conductive
locations such as metal decking and steel work.
9. Keep the generator clean and free of oil, mud and
other foreign matter.
10.Extension cords, power cords, and all electrical
equipment must be in good condition. Never
operate electrical equipment with damaged or
defective cords.
11.Store the generator in a well ventilated area with
the fuel tank empty. Fuel should not be stored near
the generator.
12.Your generator should never be operated under
these conditions:
a. Uncontrolled change in engine speed.
b. Electrical output loss.
c. Overheating in connected equipment.
d. Sparking.
e. Damaged receptacles.
f. Engine misfire.
g. Excessive vibration.
h. Flame or smoke.
i. Enclosed compartment.
j. Rain, snow or inclement weather. Do not let
the unit get wet when operating.
DANGER indicates a potentially
hazardous situation which, if not
avoided, WILL result in death or
serious injury.
SAFETY AND OPERATION RULES
Safety alert symbol; To alert you to
potential personal injury hazards.
Hazardous materials, toxic or very toxic
materials.
Risk of electrocution or shock.
Rotating parts - entanglement hazard.
Flammable materials.
Hot surface, do not touch the surface.
Explosion hazard. Corrosive materials.
English Customer Hotline 1-800-445-1805
4
13.Check the fuel system periodically for leaks or
signs of deterioration such as chafed or spongy
hose, loose or missing clamps, or damaged tank or
cap. All defects should be corrected before
operation.
14.The generator should be operated, serviced, and
refueled only under the following conditions:
a. Start and run the generator outdoors. Do
not run the generator in an enclosed area,
even if doors or windows are open; avoid
areas where vapors may be trapped, such as
pits, garages, cellars, excavations and boat
bilges. DANGER - CARBON MONOXIDE
HAZARD: The engine exhaust contains
carbon monoxide, a poisonous, odorless,
invisible gas which, if breathed, may cause
death or serious personal injury. If you start
to feel sick, dizzy or weak while using the
generator, shut it off and get to fresh air
right away; you may have carbon monoxide
poisoning.
b.Good ventilation for cooling. Air flow and
temperatures are important for air cooled
units. Temperatures should not exceed 104º
F ambient (40º C).
c. Refuel the generator in a well lighted area.
Avoid fuel spills and never refuel while the
generator is running. Allow engine to cool for
two minutes prior to refueling.
d. Do not refuel near open flames, pilot lights, or
sparking electrical equipment such as power
tools, welders, and grinders.
e. The muffler and air cleaner must be installed
and in good condition at all times as they
function as flame arresters if backfiring occurs.
f. Do not smoke near the generator.
15.Ensure that generator is properly grounded. (See
“Grounding the generator” section in this
manual.)
16.Do not wear loose clothing, jewelry, or anything
that may be caught in the starter or other rotating
parts.
17.Unit must reach operating speed before electrical
loads are connected. Disconnect loads before
turning off engine.
18.To prevent surging that may possibly damage
equipment, do not allow engine to run out of fuel
when electrical loads are applied.
19.When powering solid state equipment, a Power
Line Conditioner should be used to avoid possible
damage to equipment.
20. Do not stick anything through ventilating slots,
even when the generator is not operating. This can
damage the generator or cause personal injury.
21.Before transporting the generator in a vehicle,
drain all fuel to prevent leakage that may occur.
22.Use proper lifting techniques when transporting
the generator from site
to site. Improper lifting
techniques may result
in personal injury.
23.To avoid burns, do not touch engine muffler or
other engine or generator surfaces which became
hot during operation.
YOUR PRODUCT MAY NOT BE EQUIPPED WITH A
SPARK ARRESTING MUFFLER. If the product will be
used around flammable materials, such as agricultural crops,
forests, brush, grass, or other similar items, then an approved
spark arrester should be installed and is legally required in the
State of California. The California statutes requiring a spark
arrester are Sections 13005(b), 4442 and 4443. Spark
Arresters are also required on some U.S. Forest Service land
and may also be legally required under other statutes and
ordinances. For more information, contact Powermate, LLC,
1300 Gresham Road, Marietta, GA 30062. 1-800-445-1805
In order to prevent overloading and possible damage to
your generator it is necessary to know the total wattage of the
connected load. To determine which tools and/or appliances
your generator will run follow these steps:
1. Determine if you want to run one item or multiple items
simultaneously.
2. Check wattage requirements for the items you will be
running by referring to the load’s nameplate or by
calculating it (multiply amps x volts = watts).
3. Total the watts for each item. If the nameplate only gives
volts and amps, multiply volts x amps = watts.
1 KW = 1,000 watts.
4. Motorized appliances or tools require more than their
rated wattage for start up.
NOTE: Allow 2 1/2 to 4 times the listed wattage for
starting equipment powered by electric motors.
5. The generators rated watts should match or exceed the
total number of watts required for the equipment you
want to run.
6. Always connect the heaviest load to the generator first,
then add other items one at a time.
SPARK ARRESTER
SPARK ARRESTER
DETERMINING TOTAL WATTAGE
DETERMINING TOTAL WATTAGE
The engine exhaust from this product contains chemicals
known to the State of California to cause cancer, birth defects,
or other reproductive harm.
CALIFORNIA PROPOSITION 65 WARNING
A power line conditioner should be used when running
one or more of the following solid state items:
Garage door openers
Kitchen appliances with digital displays
Televisions
Stereos
Personal computers
Quartz clocks
Copy machines
Telephone equipment
Other solid state equipment may require a power line
conditioner. For more information, contact our Customer
Service Department at 1-800-445-1805.
To avoid backfeeding into utility systems, isolation of the
residence electrical system is required.
Before temporary connection of the generator to the
residence electrical system, turn off the main
service/disconnect.
If your generator is to be used as a stand-by power source
in case of utility power failure, it should be installed by a
registered electrician and in compliance with all applicable
local electrical codes.
Proper use requires that a double throw transfer switch be
installed by a licensed qualified electrician so that the
building's electrical circuits may be safely switched between
utility power and the generator's output, thereby preventing
backfeed into the power utility's electrical system.
Always follow local codes and regulations that apply to
the installation of any item that concerns this product.
1. NFPA 70 - National Electrical Code available from
www.nfpa.org.
2. NFPA 37 - Standard for Installation and Use of
Stationary Combustible Engines available from
www.nfpa.org.
3. NFPA 5000 - Building Construction and Safety Code
available from www.nfpa.org.
4. Agricultural Wiring Handbook available from
www.rerc.org.
5
English Customer Hotline 1-800-445-1805
OPERATING VOLTAGE
OPERATING VOLTAGE
CAUTION: Operating voltage and frequency
requirement of all electronic equipment should be
checked prior to plugging them into this generator.
Damage may result if the equipment is not designed
to operate within a +/- 10% voltage variation, and +/-
3 hz frequency variation from the generator name
plate ratings. To avoid damage, always have an
additional load plugged into the generator if solid
state equipment (such as a television set) is used. A
power line conditioner is recommended for some solid
state applications.
INSTALLATION
INSTALLATION
To avoid possible personal injury or equipment
damage, a registered electrician or an authorized
service representative should perform installation
and all service. Under no circumstances should an
unqualified person attempt to wire into a utility
circuit.
To avoid backfeeding into utility systems, isolation of
the residence electrical system is required. Before
temporary connection of a generator to the residence
electrical system turn off the main switch. Before
making permanent connections a double throw
transfer switch must be installed. To avoid
electrocution or property damage, only a trained
electrician should connect generator to residence
electrical system. California law requires isolation of
the residence electrical system before connecting a
generator to residence electrical systems. Temporary
connection not recommended due to backfeeding.
6
Customer Hotline 1-800-445-1805English
1. Open carton and remove packaging materials.
2. Remove generator, accessory boxes, and literature
from carton. If any items are missing or damaged,
contact our Product Service Department at
1-800-445-1805.
1 - Operator Manual
1 - 0.6L Oil SAE 10-W30 1 - Oil Funnel
1 - L5-30P to TT-30R Adapter Plug
2 - 10” Flat Free Wheels
2 - Handles
1 - Hardware Bag containing:
2 - Rubber Feet 2 - Foot Spacers
2 - Axle Pins
1 - Fastener Bag containing:
1 - Tool Kit containing:
UNPACKING THE GENERATOR
UNPACKING THE GENERATOR
ITEM DESCRIPTION QTY
1 M12 X 4MM FLAT WASHER 2
2 M12 X 1.5MM FLAT WASHER 2
3 M8 FLAT WASHER 2
4 M8 X 40 BOLT 2
5 M8 X 65 BOLT 2
6 M8 NYLOC NUT 4
7 LOCK PIN 2
ITEM
DESCRIPTION
QTY
1
5 MM HEX KEY
1
2
DOUBLE OPEN WRENCH 10X13 MM
1
3
SPARK PLUG WRENCH W/ROD
1
w
ww.powermate.com 12/13 0070712
O
perator Manual
M
anuel de l’opérateur • Manual del operador
E
LECTRIC GENERATOR • GROUPE ELECTROGENE • GENERADOR ELECTRICO
PM0143250
IMPORTANT - Prière de vous assurer que
l
es personnes destinées à utiliser cet
a
ppareil ont pris soin d'en lire et d'en
c
omprendre le mode d'emploi ou les
d
irectives avant de le mettre en marche.
E
nregistrer le numéro de série figurant
sur la plaque signalétique du groupe
é
lectrogène:
N
º de série ____________________
I
MPORTANT – Please make certain that
p
ersons who are to use this equipment
t
horoughly read and understand these
instructions and any additional
i
nstructions provided prior to operation.
R
ecord the serial number as indicated on
y
our Generator’s nameplate:
S
erial No.______________________
IMPORTANTE - Asegúrese que las
p
ersonas que utilizarán este equipo lean
y
entiendan completamente estas
i
nstrucciones y cualquier instrucción
a
dicional proporcionada antes del
f
uncionamiento.
Registre de serie como se indica en la
p
laca del nombre de su generador:
N
o. de serie ___________________
D
O NOT RETURN TO
S
TORE!
C
ALL US FIRST!
C
USTOMER HOTLINE
1
-800-445-1805
F
OR QUESTIONS OR SERVICE
I
NFORMATION
N
O LO DEVUELVA A
L
A TIEND A!
¡
PRIMERO LLÁMENOS!
L
ÍNEA DIRECTA DE ATENCIÓN
A
L CLIENTE
1
-800-445-1805
PARA l a INF OR MAC ION d e
P
REGUNTAS O SERVICIO
NE PAS RETOURNER
A
U MAGASIN!
A
PPELEZ–NOUS D’ABORD!
A
SSISTANCE TELEPHONIQUE
A
LA CLIENTELE
1
-800-445-1805
P
OUR L'INFORMATION DE
QUESTIONS OU SERVICE
7
Customer Hotline 1-800-445-1805
A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B. 120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle.
However, total power drawn must be kept within nameplate
ratings.
C. 120 Volt, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from this
receptacle, provided it is the only receptacle used. Total
current must be limited to the nameplate rating. If other
receptacles are used at the same time, total power used must be kept
within nameplate ratings.
D. Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The cir-
cuit protector may be reset by pushing the button of the protector.
E. Ground Terminal
F. Air Filter
G. Engine On/Off Switch
H. 208 CC OHV Engine
I. Recoil Starter
J. Engine Choke Lever
K. Oil Filler Cap
L. Oil Drain Plug
M. 4.5 Gallon Metal Fuel Tank
N. Fuel Tank Cap
O. Fuel Gauge
P. Fuel Shut-Off Valve
Q. L5-30P to TT-30R RV Adapter
This adapter converts from the 120
Volt, 30 Amp Twistlock Receptacle to a
120 Volt RV Plug.
R. Multimeter
When the generator is started, the voltage value is shown first.
Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Run/Maintenance
Timer.
Voltage (V) displays the operating voltage of the generator.
Frequency (F) displays the frequency in hertz at which the
generator is running.
The Run/Maintenance Timer displays the time in hours and
minutes each time the generator is ran. The run timer resets
to 00:00 when the generator is shut off. Built into this run
timer is a maintenance reminder. When the new generator is
ran for 25 hours, the meter will display P25. This is to
remind you to change the oil after the initial 25 hours of run
time.
When the Run/Maintenance Timer displays P50, it is
reminding you to clean the air filter.
When the Run/Maintenance Timer displays P100, it is
reminding you to change/clean the fuel filter, clean the air
filter, and change the oil.
A
B
P
D
I
K
L
G
J
N
C
E
D
R
M
H
O
English
F
GENERATOR FEATURES
GENERATOR FEATURES
Q
8
Customer Hotline 1-800-445-1805
PORTABILITY KIT PART NUMBER: 0071015
TOOLS REQUIRED: 10x13 mm wrench and 5 mm hex key (provided in tool kit), block(s) of wood (minimum of 6” tall).
Refer to the parts list on page 43.
WHEEL INSTALLATION
1. Block up the alternator end of generator to install wheel kit.
2. Slide the wheel (item 11) and spacer (item 10) onto the axle (item 7).
3. Slide axle through the axle tube on the carrier, with the offset side of the wheel hub against the axle tube.
4. Secure the wheel to the axle with the M12 washer (item 9) and pin (item 8).
5. Repeat above instructions for the remaining wheel.
FOOT INSTALLATION
1. Blocking up the engine side of the generator, assemble the foot spacer (item 12) and foot (item 13) to the carrier (align
with holes in tubing) with an M8 washer (item 14) and M8 x 65 bolt (item 6). Thread an M8 nyloc nut (item 51) to the
bolt to secure the assembly.
2. Repeat above instructions for the remaining foot.
HANDLE INSTALLATION
1. Slide M8 x 40 bolt (item 50) through handle bracket and handle (items 49, 53 and 52 or 60) as shown in diagram and
secure with M8 nut (item 51). Tighten until handle is securely clamped to the carrier.
2. To extend the handle, press the handle release button. Pull the handle up until the handle release button locks in place.
3. Repeat above instructions for the remaining handle.
PORTABILITY KIT INSTALLATION
PORTABILITY KIT INSTALLATION
English
9
Customer Hotline 1-800-445-1805
GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
PROTECTION
Some jobsites and local codes may require GFCI
protection for personnel before operation of your generator. If
your generator is not already equipped with a GFCI
receptacle, GFCI In-line cord sets may be purchased from
your local electrical supply store or home builder appliance
store.
These cord sets are available in various plug and
amperage configurations. (Make sure your generator is
properly Grounded.)
GROUNDING THE GENERATOR
The National Electric Code requires that this product be
properly connected to an appropriate earth ground to help
prevent electric shock. A ground terminal connected to the
frame of the generator has been provided for this purpose.
Connecting a length of heavy gauge (12 AWG min.) copper
wire between the generator Ground Terminal and a copper rod
driven into the ground should provide a suitable ground
connection. However, consult with a local electrician to insure
that local codes are being adhered to.
LUBRICATION
DONOT attempt to start this engine without filling the
crank case with the proper amount and type of oil. Your
generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the
engine.
Fill the engine with oil according to the operator manual.
For units with a dipstick, fill oil to the proper level. Units
without a dipstick should be filled to the top of the opening of
the oil fill.
LOW OIL SENSOR
The unit is equipped with a low oil sensor. If the oil level
becomes lower than required, the sensor will activate a
warning device or stop the engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting at an angle
that forces oil to shift. Place on an even surface to correct this.
If engine fails to start, the oil level may not be sufficient to
deactivate low oil level switch. Make sure the sump is
completely full of oil.
FUEL
Fill the tank with clean, fresh unleaded automotive
gasoline. Regular grade gasoline may be used provided a high
octane rating is obtained (at least 85 pump octane). We
recommend always using a fuel stabilizer. A fuel stabilizer
will minimize the formulation of fuel gum deposits during
storage. The fuel stabilizer can be added to the gasoline in the
fuel tank, or into the gasoline in a storage container.
BEFORE OPERATION
BEFORE OPERATION
GROUND TERMINAL LOCATION:
Ground
Terminal
Do not use a pipe carrying combustible material as
the ground source.
English
SLOWLY ADD UNLEADED GASOLINE
TO FUEL TANK
DO NOT OVERFILL TANK
DO NOT FILL ABOVE TOP OF FUEL
SCREEN. THIS WILL ALLOW
EXPANSION IN HOT WEATHER AND
PREVENT OVERFLOW.
Customer Hotline 1-800-445-1805
10
English
POSITIONING
Place the generator set on a flat and solid surface to
prevent it from sinking.
Keep fuel, oil or other explosives at a safe distance from
the generator set.
Select a site that is well ventilated and protected from the
weather.
Place the generator set safely away from people and
animals.
CAUTION: TILTING CAN CAUSE FUEL
SPILLAGE
At high altitude, the standard carburetor air-fuel mixture
will be too rich. Performance will decrease and fuel
consumption will increase. A very rich mixture will also foul
the spark plug and cause hard starting. Operation at an
altitude that differs from that at which this engine was
certified, for extended periods of time, may increase emis-
sions.
High altitude performance can be improved by specific
modifications to the carburetor. If you always operate your
engine at altitudes above 914 meters (3,000 feet), have your
authorized service center perform a carburetor modification.
HIGH ALTITUDE KIT PART NUMBER: 0071014
Even with a carburetor modification, engine horsepower
will decrease about 3.5% for each 300 meter (1,000 foot)
increase in altitude. The effect of altitude on horsepower will
be greater if no carburetor modification is made. A decrease
in engine horsepower will decrease the power output of the
generator.
NOTICE: Warranty is Void if the necessary adjustments for
high altitude use are not made.
HIGH ALTITUDE OPERATION
HIGH ALTITUDE OPERATION
When the carburetor has been modified for high
altitude operation, the air-fuel mixture will be too lean
for low altitude use. If the generator is used at low
altitudes after a carburetor modification, the
carburetor may cause the engine to overheat and result
in serious engine damage. For use at low altitudes,
have your authorized service center return the
carburetor to original factory specifications.
Customer Hotline 1-800-445-1805
11
English
PRE-START PREPARATION
Before starting the generator, check for loose or missing
parts and for any damage which may have occurred during
shipment.
STARTING THE ENGINE
1. Check oil level and fuel.
2. Disconnect all electrical loads from the unit.
3. Open fuel shut off valve (A).
4. Adjust choke (B) as necessary.
5. Set the engine switch (C) to the “ON" position.
6. Pull on the starter rope (D) with fast steady pull. As the
engine warms up, readjust the choke.
APPLYING LOAD
This unit has been pretested and adjusted to handle its full
capacity. Before starting the generator, disconnect all load.
Apply load only after generator is running. Voltage is
regulated via the engine speed adjusted at the factory for correct
output. Readjusting will void warranty.
SHUTTING THE GENERATOR OFF
1. Remove entire electrical load.
2. Let the engine run for two minutes without load.
3. Move the engine switch to the “OFF” position.
4. Do not leave the generator until it has completely
stopped.
5. Close the fuel shut off valve if the engine is to be put in
storage or transported.
6. If a cover is used, do not install until unit has cooled.
7. If the generator will not be used again for an extended
time period, refer to the SERVICE AND STORAGE
section of this manual.
STARTING THE UNIT
STARTING THE UNIT
Gasoline is very dangerous.
Serious injury or death may result from fire caused
by gasoline contacting hot surfaces.
1. Do not fill fuel tank with engine running.
2. Do not spill fuel while refilling tank.
3. Do not mix oil with gasoline.
4. Follow all instructions and warnings in the
operator manual.
This generator must not be operated without all
factory installed heat shields in place. Failure to
comply may cause the fuel tank to overheat and result
in personal injury from fire.
Provide adequate ventilation for toxic exhaust
gases and cooling air flow.
Do not start or run the generator in an enclosed
area, even if door or windows are open.
Engines give off carbon monoxide, an odorless,
colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
Allow generator to run at no load for five minutes
upon each initial start-up to permit engine and
generator to stabilize.
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first two to three hours of operations).
D
A
S
TART RUN
C
B
Customer Hotline 1-800-445-1805
12
English
SPARK PLUG
Remove the spark plug and clean the electrodes section
with a wire brush or sandpaper. Next, set the gap at .028/.031
inches (0.7-0.8 mm) by adjusting the negative electrode.
Replace the spark plug with correct torque: 14 ft-lb (20 N.m)
OIL TYPE
Use new good quality oil, SJ or later service category.
The oil to be used depends upon the temperature at which the
engine is operated:
Below 32° F (0° C) . . . . . . . . .SAE 10W, 10W-30, or 10W-40
32 to 80° F (0 to 25° C) . . . . . .SAE 20W, 10W-30, or 10W-40
80 to 95° F (25 to 35° C) . . . . .SAE 30W, 10W-30, or 10W-40
Above 95° F (35° C) . . . . . . . . . . . . . . . . . . . . . . . . .SAE 40W
OIL REPLACEMENT
1. Change oil while engine is warm.
2. Place the generator unit on a level surface.
3. Remove the oil filler cap.
4. Open the oil drain plug and let oil drain completely into a
pan placed under the engine.
5. Check gaskets. Replace if required.
6. Reinstall the oil drain plug and refill engine with clean
oil.
7. Replace the oil filler cap.
AIR FILTER CLEANING
1. Unscrew the air filter cover.
2. Remove filter element and wash well in solvent.
3. Pour a small amount of oil onto the filter element and
gently squeeze out any excess oil.
4. Replace the filter element and air filter cover.
5. Be sure the filter cover seals properly all around.
FUEL SHUT OFF VALVE FILTER CLEANING
1. Remove the cup at the bottom of the fuel shut off valve
with a small wrench.
2. Remove the fuel shut off valve filter.
3. Clean and wash out the filter and cup and replace.
FUEL STRAINER CLEANING
1. Remove the plastic fuel strainer, located below the fuel
tank cap.
2. Wash the strainer in solvent and replace.
MAINTENANCE
MAINTENANCE
ITEM NOTES
Daily (Before
operation)
Initial
25 hours
Every
50 hours
Every
100 hours
Spark Plug
Check condition. Adjust gap and
clean. Replace if necessary.
ü
Engine Oil Check oil level.
ü
Replace.
ü ü
Air Filter Clean, replace if necessary.
ü
Fuel Filter
Clean fuel filter and fuel tank strainer.
Replace if necessary.
ü
Fuel Line
Check fuel hose for cracks or other
damage. Replace if necessary.
ü
Exhaust
System
Check for leakage. Retighten or
replace gasket if necessary.
ü
Check spark arrester screen.
Clean/replace if necessary.
ü
Carburetor Check choke operation.
ü
Starting
System
Check recoil starter operation.
ü
Fittings/
Fasteners
Check. Replace if necessary.
ü
PERIODIC MAINTENANCE
PERIODIC MAINTENANCE
Replace with only the same type of spark plug which
was removed. An improper spark plug can cause the
engine to overheat, emit smoke, or otherwise perform
poorly.
VALVE CLEARANCE
Intake — 0.08 mm - 0.12 mm (.003 inch - .005 inch)
Exhaust — 0.13 mm - 0.17 mm (.005 inch - .007 inch)
After the first 50 hours of operation, check the valve clearance in
the engine and adjust if necessary.
NOTICE: If unsure about doing this procedure or if the proper tools
are not available, take the generator to the nearest service center to
have the valve clearance adjusted. This is a very important procedure
to ensure longest life for the engine.
SPARK ARRESTER SCREEN
Remove screen every 50 hours for cleaning and
inspection. Replace if damaged.
Clean and inspect the spark arrester as follows:
1. Remove the screen retainer by removing the retainer clamp.
2. Remove the retainer screw from the muffler outlet tube.
3. Slide the spark arrester screen out from the muffler outlet tube.
4. Be careful not to damage the spark arresting screen. The spark
arrester must be free of breaks and holes. If screen is not
damaged, clean it with a commerical solvent.
5. Replace the screen and retainer and secure with retainer screw
and clamp.
GENERATOR: Brushes
The brushes in the generator should be inspected once every year
for chips and cracks. Brushes should be replaced when they are worn
to 1/4 inch (7mm).
NOTE: Replace brushes in sets only, never separately.
Replace only with brushes specified in parts list. Other brushes
may appear to be identical but may have completely different
mechanical and electrical characteristics.
INSPECTING THE BRUSHES:
1. Remove 2 screws (V) and end cover (W).
2. Remove screw (X) holding the brush module (Y).
3. Disconnect the blue (+) and yellow (-) brush wires from the
tabs.
4. Replace if worn to 1/4 inch (7mm).
5. Do not over tighten screw.
HEATSHIELD:
Inspect to ensure that all heat shields and heat deflectors are intact
and in place. Do not remove any parts or modify parts. Removing or
modifying parts could cause serious
damage to the unit.
ENGINE: Carburetor Icing
During the winter months, rare atmospheric conditions may
develop which will cause an icing condition in the carburetor. If this
develops, the engine may run rough, loose power, and may stall. Call
Product Service for more information.
QUICK STARTING TIPS FOR UNITS THAT HAVE BEEN
SITTING FOR AWHILE:
If your unit has been sitting around for a long time period and is
hard to start, try doing some of these easy steps before calling the
Customer Hotline.
1. Check the oil level.
2. Replace the old fuel.
3. Change the spark plug.
4. Check the fuel lines. Make sure the fuel shut off valve is open.
5. Check all generator parts for integrity.
6. Clean the Carburetor.
INFREQUENT SERVICE
If the unit is used infrequently, difficult starting may result. To
eliminate hard starting, follow these instructions:
1. Run the generator at least 30 minutes every month.
2. Run the generator, then close the fuel shut-off valve and allow
the unit to run until the engine stops.
3. Move the engine switch to the “OFF” position.
LONG TERM STORAGE
When the generator set is not being operated or is being stored
more than one month, follow these instructions:
1. Replenish engine oil to upper level.
2. Run the generator, then close the fuel shut-off valve and allow
the unit to run until the engine stops.
3. Move the engine switch to the “OFF” position.
4. After the unit has cooled, drain gasoline from fuel tank, fuel line
and carburetor.
5. Pour about one teaspoon of engine oil through the spark plug
hole, pull the recoil starter several times and replace the plug.
Then pull the starter until you feel the piston is on its
compression stroke and leave it in that position. This closes
both the intake and exhaust valves to prevent the inside of the
cylinder from rusting.
6. Cover the unit and store in a clean, dry place that is well
ventilated away from open flame or sparks.
NOTE: We recommend always using a fuel stabilizer. A fuel
stabilizer will minimize the formulation of fuel gum deposits
during storage. The fuel stabilizer can be added to the gasoline
in the fuel tank, or into the gasoline in a storage container.
13
Customer Hotline 1-800-445-1805
SERVICE AND STORAGE
SERVICE AND STORAGE
English
14
Customer Hotline 1-800-445-1805
ENGINE TROUBLESHOOTING
ENGINE TROUBLESHOOTING
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-stroke, single cylinder, gasoline, OHV
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208 cc, 12.69 cubic inches
Maximum HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 HP @ 3600 rpm
Starting System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Recoil (electronic ignition)
Driving System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct coupling, tapered crank
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 oz.
Spark Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NGK BPR7ES or equivalent
Governor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mechanical (adjustable)
Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Forced air cooling
Carburetor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Float
Air Cleaner Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Foam element
ENGINE SPECIFICATIONS
ENGINE SPECIFICATIONS
English
Customer Hotline 1-800-445-1805
15
English
CONTACT THE
POWERMATE
PRODUCT SERVICE
DEPARTMENT AT
1-800-445-1805
or at www.powermate.com
to obtain warranty service
information or to order
replacement parts or
accessories.
HOW TO ORDER REPLACEMENT PARTS
Even quality built equipment such as the electric
generator you have purchased might need occasional
replacement parts to maintain it in good condition over the
years. To order replacement parts, please give the following
information:
1. Model No. and Serial No. and all specifications shown
on the Model No./Serial No. plate.
2. Part number or numbers as shown in the Parts List
section.
3. A brief description of the trouble with the generator.
Powermate, LLC
1300 Gresham Road
Marietta, GA 30062
1-800-445-1805
www.powermate.com
Register your Powermate® generator
online at www.powermate.com
.
Warranty Coverage: Powermate, LLC (the Company)
warrants to the original retail customer in North America that
it will repair or replace, free of charge, any parts found by
the Company or its authorized service representative to be
defective in material or workmanship. This warranty covers
the cost of replacement parts and labor for defects in
material or workmanship.
Not Covered:
· Transportation charges for sending the product to the
Company or its authorized service representative for
warranty service, or for shipping repaired or replacement
products back to the customer; these charges must be borne
by the customer.
· If a separate operator's manual and engine warranty
from the engine manufacturer is included with this product,
only that warranty will apply to the engine.
· Damages caused by abuse or accident, and the effects
of corrosion, erosion and normal wear and tear.
· Warranty is voided if the customer fails to install,
maintain and operate the product in accordance with the
instructions and recommendations of the Company set forth
in the owner's manual, or if the product is used as rental
equipment.
· The Company will not pay for repairs or adjustments to
the product, or for any costs or labor, performed without the
Company's prior authorization.
· Starting batteries, circuit breakers, fuses, or light bulbs.
Warranty Period: Two (2) years from the date of purchase
on products used solely for consumer applications; if a
product is used for business or commercial applications, the
warranty period will be limited to one (1) year from the date
of purchase. For warranty service, the customer must
provide dated proof of purchase and must notify the
Company within the warranty period.
For warranty service: Call toll free 800-445-1805, or
write to Powermate, LLC, Product Services, 1300
Gresham Road, Marietta, GA 30062.
EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES
NO OTHER WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED. IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND OF FITNESS
FOR A PARTICULAR PURPOSE, ARE HEREBY
DISCLAIMED. THE WARRANTY SERVICE DESCRIBED
ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS
WARRANTY; LIABILITY FOR INCIDENTAL AND
CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE
EXTENT PERMITTED BY LAW.
This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state. Some
states do not allow a disclaimer of implied warranties, or the
exclusion or limitation of incidental and consequential
damages, so the above disclaimers and exclusions may not
apply to you.
LIMITED WARRANTY
LIMITED WARRANTY
SERVICE INFORMATION
SERVICE INFORMATION
REGISTER YOUR PRODUCT
16
Français Assistance Téléphonique 1-800-445-1805
AVERTISSEMENT - L'inobservation des présentes
consignes et l'ignorance des avertisse ments qui en
découlent risquent de causer des blessures et des
dommages ou d'entraîner la mort.
1. Lire attentivement le guide d'utilisation, puis s'assurer de
les comprendre avant de mettre l'appareil en marche.
Observer l'ensemble des avertissements et des directives
s'y rapportant.
2. Se familiariser avec l'appareil et tenir compte des
domaines d'usage, des restrictions et des risques
potentiels qui découlent de son utilisation.
3. On doit placer l’équipement sur un support plat et solide
4. La charge doit être dans les normes spécifiées sur la
plaque signalétique de l'appareil. Toute surcharge abîme
l'appareil et en raccourcit la durée de vie utile.
5. Le moteur ne doit pas tourner à des vitesses excessives
car ceci augmente les risques de blessures personnelles.
Ne touchez pas aux pièces ce qui pourrait augmenter
ou réduire la vitesse régulée.
6. Afin d’empêcher les démarrages imprévus, toujours
enlever la bougie ou le câble de la bougie avant d’ajuster
le groupe électrogène ou le moteur.
7. Un appareil dont les pièces sont cassées, auquel il
manque des pièces ou qui n’a pas de carter ou de
coquille protectrice ne doit en aucun cas être
utilisé. Contacter notre service après-vente pour
des pièces de rechange.
8. Ne pas faire fonctionner ou entreposer l’appareil dans un
endroit humide ni sur une surface mouillée, ni dans un
endroit où il sera en contact avec des surfaces
conductrices telles que des planchers ou armatures
métalliques.
9. Garder l'appareil propre et libre de toute huile, boue ou
autre matière étrangère.
10. Les rallonges, les cordons d’alimentation et tout appareil
électrique doivent être en bon état. Ne jamais faire
fonctionner un appareil électrique dont le cordon
d’alimentation est abîmé ou défectueux.
11. Rangez le nettoyeur haute pression dans un endroit bien
ventilé, réservoir d’essence vide. On ne doit pas ranger
l’essence près du groupe électrogène.
12. Vous ne devez jamais utiliser votre appareil sous ces
conditions:
a. Modification irrépressible du régime moteur.
b. Perte de puissance électrique.
c. Surchauffe d’appareils connectés.
d. Jaillissement d’étincelles.
e. Prises endommagées.
f. Le moteur a des ratés.
g. Vibrations excessives.
h. Flammes ou fumée.
i. Compartiment fermé.
j. Temps mauvais ou pluvieux ou neige. Éviter
d'exposer l'ap pareil à l'humidité en cours de
fonctionnement.
SÉCURITÉ
SÉCURITÉ
L'AVERTISSEMENT Indique une
situation présentant un danger
potentiel et qui, en l'absence
d'intervention, pourrait conduire à la
mort ou entraîner de graves
blessures.
La mention ATTENTION sert à
prévenir l'utilisateur d'un danger
potentiel qui risque d'occasionner
des dommages ou des blessures
légères ou modérées.
RÈGLES D’OPÉRATION ET DE SÉCURITÉ
DANGER signifie une situation
susceptible de présenter un danger
qui, s'il n'est pas évité,
CAUSERA de sérieuses
blessures, voire la mort.
Symbole d'alerte de sécurité; pour vous
avertir des éventuels risques de
blessures.
Matières dangereuses, toxiques ou très
toxiques.
Risque d'électrocution ou de décharge.
Pièces rotatives - risque d’emmêlement.
Matières inflammables.
Surface chaude - ne touchez pas la
surface.
Risque d’explosion. Matières corrosives.
GUIDE DES SYMBOLES DE SÉCURITÉ
17
Français
13. Vérifiez le système de carburant régulièrement pour
toute fuite ou signes de détérioration tels un tuyau
spongieux ou usé, une bride qui manque ou desserrée
ou un réservoir ou couvercle endommagé. On doit
corriger ces problèmes avant de faire fonctionner
l’appareil.
14. Le fonctionnement, l'entretien et le ravitaillement en
carburant de l'appareil ne doivent se faire que dans
les conditions suivantes :
a. Faites démarrer et fonctionner la génératrice
à l'extérieur. Ne faites jamais fonctionner la
génératrice dans un endroit clos, même si les
portes et les fenêtres sont ouvertes. Évitez les
endroits où les vapeurs peuvent être enfermées,
comme des fosses, des garages, des caves, des
excavations et des fonds de cale de bateau.
DANGER - RISQUE D'ÉMISSION DE
MONOXYDE DE CARBONE :
L'échappement des moteurs contient du
monoxyde de carbone, un gaz toxique, inodore et
invisible qui, s'il est respiré, peut causer de
sérieuses blessures, voire la mort. Si vous ne vous
sentez pas bien, êtes pris d'étourdissement ou vous
sentez faible en utilisant la génératrice, mettez-la
hors tension et respirez de l'air frais
immédiatement car vous souffrez peut-être
d'un empoisonnement au monoxyde de carbone.
b. Bonne aération pour le refroidissement. Le débit
d'air et la température sont importants pour les
systèmes à refroidissement à air. La température
ne devrait pas dépasser 104º F (40º C).
c. Refaites le plein du groupe électrogène dans un
endroit bien éclairé. Évitez les débordements de
carburant et ne refaites jamais le plein lorsque
l'appareil est en marche.
d. Ne faites pas le plein près de flammes nues, de
veilleuses ou d’équipement électrique projetant des
étincelles comme les outils électriques, les soudeuses
et les meuleuses.
e. Le silencieux et le filtre à air doivent toujours être en
place et en bon état puisqu’ils jouent le rôle de
coupe-flammes s’il y a des ratés.
f. Ne pas fumer près du générateur.
15. S’assurer que l'appareil est correctement posé sur le sol.
(Voir la section «Mise en place de l'appareil» dans le
présent manuel.)
16. Ne portez pas de vêtements amples, de bijoux ou toute
autre chose qui pourrait se prendre dans le démarreur
ou autres pièces rotatives.
17. L'appareil doit atteindre son régime de fonctionnement
avant que toute charge y soit connectée. Débrancher
toute charge avant d’arrêter le moteur.
18. Afin d’empêcher les pointes de tension qui pourraient
endommager les appareils branchés sur la génératrice,
ne pas laisser le moteur tomber en panne de carburant
pendant que des appareils sont branchés dessus.
19. Lorsque vous utilisez de l’équipement en solide, vous
devriez utiliser un protecteur de surtension pour éviter
d’endommager l’équipement.
20. Ne rien mettre dans les fentes d’aération, même quand
l'appareil n’est pas en marche. Ceci pourrait l’abîmer ou
provoquer des blessures.
21. Avant de transporter la génératrice dans un véhicule, le
vider de tout carburant afin d’empêcher les fuites.
22. Pour transporter l'appareil d’un site à l’autre, utilisez les
bonnes techniques de
levage sinon vous
pourriez vous blesser.
23. Pour éviter les brûlures, ne touchez pas au silencieux du
moteur ou à toute autre surface du moteur ou du
générateur qui se réchauffe durant le fonctionnement.
VOTRE PRODUIT PEUT NE PAS ÊTRE MUNI D'UN
SILENCIEUX PARE-ÉTINCELLES. S’il doit être utilisé à
proximité de matériaux inflammables tels que récoltes, forêts,
broussailles, herbes ou autres, il est fortement recommandé d’installer
un pare-étincelles, par ailleurs obligatoire en Californie. Les articles
de la loi californienne relatifs à l’usage de pare-étincelles sont les
suivants : 13005(b), 4442 et 4443. L’usage d’un pare-étincelles est
également exigé sur certains des territoires du service des Forêts
américain et peut également l’être par d’autres lois et règlements.
Pour de plus amples renseignements à cet égard, prière de contacter
Powermate, LLC, 1300 Gresham Road, Marietta, GA 30062.
Téléphone : 1-800-445-1805.
Afin d’éviter à la génératrice la surcharge et les dommages
possibles, il faut connaître la puissance totale de la charge branchée.
Pour déterminer quels outils et/ou quels appareils peuvent
fonctionner avec votre générateur, suivez ces étapes :
1. Déterminez si vous désirez faire fonctionner un ou plusieurs
appareils simultanément.
2. Vérifiez les exigences normales pour démarrer et faire
fonctionner les appareils voulus en vous reportant à la plaque
signalétique de charge ou en effectuant ce calcul
(multipliez les ampères x volts = watts).
3. Additionnez le nombre de watts de démarrage et de
fonctionnement de chaque appareil. Toutefois, la plaque
signalétique de l’équipement vous donnera des chiffres de
consommation d’électricité plus exacts. Si la plaque ne vous
donne que des volts et des ampères, multipliez les volts par les
ampères = watts. 1KW = 1 000 watts.
4. Les appareils ou les outils à moteur exigent plus que leur
puissance indiquée pour le démarrage.
REMARQUE : Prévoir 2 1/2 - 4 fois la puissance indiquée
pour la mise en marche de l’appareil.
5. La puissance nominale du générateur devrait être égale ou
supérieure au nombre total de watts nécessaires au
fonctionnement de l'équipement à alimenter.
6. Branchez toujours d’abord la charge la plus lourde au
générateur, puis ajoutez les les autres une à une.
Assistance Téléphonique 1-800-445-1805
PARE-ÉTINCELLES
PARE-ÉTINCELLES
DÉTERMINATION DE LA PUISSANCE
DÉTERMINATION DE LA PUISSANCE
TOTALE NÉCESSAIRE
TOTALE NÉCESSAIRE
Le tuyau d'échappement de ce produit contient des produits
chimiques qui sont reconnus par l'État de Californie comme
pouvant causer le cancer, des anomalies congénitales ou
d'autres problèmes reproductifs.
PROPOSITION 65 DE LA CALIFORNIE – AVERTISSEMENT
Il est préférable d'utiliser un filtre de secteur lors de la
mise en fonction d'un ou de plusieurs des composants à
semiconducteurs suivants:
Ouvres-portes de garage
Appareils de cuisine à affichage digital
Téléviseurs
Stéréos
Ordinateurs personnel
Pendules à quartz
Machines à photocopier
Équipement téléphonique
D'autres composants à semiconducteurs peuvent
nécessiter l'usage d'un filtre de secteur. Pour de plus amples
renseignements à cet égard, prière de contacter le service à la
clientèle en composant le numéro de téléphone
1 800 445 1805.
Pour éviter les retours de courant dans l’installation
électrique de la maison, il est nécessaire d’assurer son
isolation.
Avant de procéder au raccordement temporaire du
générateur au système électrique de la résidence, débrancher le
sectionneur du réseau d'alimentation principal.
Si du générateur est utilisée comme source auxiliaire en
cas de panne de courant, il doit être installé par un électricien
qualifié et en conformité avec tous les codes locaux
applicables.
Pour que l’installation soit correcte, un commutateur de
transfert à deux directions doit être installé par un électricien
qualifié et licencié de façon à ce que les circuits électriques du
bâtiment puissent être commutés du secteur au générateur sans
danger, empêchant ainsi les retours de courant dans le secteur.
Toujours observer les codes et règlements locaux qui
s'appliquent à l'installation de tout appareil compatible
avec ce produit.
1. NFPA 70 - Code national de l'électricité disponible sur
le site www.nfpa.org
2. NFPA 37 - Norme d'installation et d'utilisation des
moteurs fixes à combustible disponible sur le site
www.nfpa.org
3. NFPA 5000 - Construction de bâtiment et code de
sécurité, disponible sur le site www.nfpa.org
4. Manuel de câblage du réseau d'alimentation de
secours des appareils agricoles disponible sur le site
www.rerc.org
18
Français
VÉRIFIER LA TENSION
VÉRIFIER LA TENSION
ATTENTION : Vérifier la tension et la fréquence
requises avant de brancher tout équipement
électronique sur le générateur. Le générateur peut se
trouver endommagé si les appareils branchés ne sont
pas prévus pour fonctionner à une tension égale à ±
10% et une fréquence égale à ± 3 hz de celles
indiquées sur la plaque signalétique du générateur.
Pour éviter tout dommage, toujours brancher une
charge additionnelle sur le générateur lorsqu’un
appareil à circuits intégrés (tel qu’un téléviseur) est
utilisé. Une varistance peut être aussi nécessaire pour
certaines applications, dans le cas d’un ordinateur,
par exemple. Une varistance peut être aussi
nécessaire pour certaines applications de
l’équipement en solide.
INSTALLATION
INSTALLATION
Pour éviter toute blessure et tout dommage aux appareils,
faire effectuer l’installation électrique et toutes réparations
par un électricien licencié ou un specialiste du service
après-vente agréé. En aucune circonstance, une personne
non qualifiée ne doit-elle essayer de réaliser le câblage sur
l’installation électrique existante.
Pour éviter les retours de courant dans le secteur, il est
nécessaire d’assurer l’isolation électrique de la maison.
Avant d’effectuer la connexion temporaire du générateur
sur l’installation électrique de la maison, couper le courant
à l’interrupteur principal. Avant de réaliser des connexions
permanentes, installer un commutateur de transfert à deux
directions. Pour éviter toute électrocution ou des dommages
matériels, faire connecter le générateur à l’installation
électrique de la maison par un électricien qualifié. Les lois
californiennes exigent l’isolation de l’installation électrique
de la maison avant d’y connecter un groupe électrogène. Il
n'est pas recommandé de procéder au raccordement
temporaire de l'appareil en raison de la réalimentation.
Assistance Téléphonique 1-800-445-1805
19
1. Ouvrez la boîte et retirez les matériaux d’emballage.
2. Retirez la génératrice, les boîtes d’accessoire et la
documentation de la boîte. Si un article est manquant
ou endommagé, contactez notre département de
service pour les produits au 1-800-445-1805.
1 - Manuel de l’opérateur
1 - 0,6 L d’huile SAE 10-W30
1 -Entonnoir à huile
1 - Adaptateur L5-30P vers TT-30R
2 - Roues de 10 po à l’épreuve des crevaisons
2 - Poignées
1 - Sac de pièces de quincaillerie comprenant :
2 - Pieds en caoutchouc
2 - Pièces d’espacement de pied
2 - Clavettes d’essieu
1 - Sac d’éléments de fixation comprenant :
1 - Ensemble d’outils comprenant :
DÉBALLAGE DE VOTRE GÉNÉRATRICE
DÉBALLAGE DE VOTRE GÉNÉRATRICE
ARTICLE
DESCRIPTION
QUANTITÉ
1
M12 X 4MM RONDELLE PLATE
2
2
M12 X 1.5MM RONDELLE PLATE
2
3
M8 RONDELLE PLATE
2
4
M8 X 40 BOULON
2
5
M8 X 65 BOULON
2
6
M8 ÉCROUS NYLOC
2
7
GOUPILLE
2
ARTICLE
DESCRIPTION
QUANTITÉ
1
CLÉ HEXAGONALE DE 5 MM
1
2
CLÉ À FOURCHE DOUBLE 10X13 MM
1
3
CLÉ À BOUGIE AVEC TIGE
1
Assistance Téléphonique 1-800-445-1805Français
w
ww.powermate.com 12/13 0070712
O
perator Manual
M
anuel de l’opérateur • Manual del operador
E
LECTRIC GENERATOR • GROUPE ELECTROGENE • GENERADOR ELECTRICO
P
M0143250
I
MPORTANT - Prière de vous assurer que
les personnes destinées à utiliser cet
a
ppareil ont pris soin d'en lire et d'en
c
omprendre le mode d'emploi ou les
d
irectives avant de le mettre en marche.
E
nregistrer le numéro de série figurant
s
ur la plaque signalétique du groupe
électrogène:
N
º de série ____________________
I
MPORTANT – Please make certain that
p
ersons who are to use this equipment
t
horoughly read and understand these
i
nstructions and any additional
instructions provided prior to operation.
R
ecord the serial number as indicated on
y
our Generator’s nameplate:
S
erial No.______________________
I
MPORTANTE - Asegúrese que las
personas que utilizarán este equipo lean
y
entiendan completamente estas
i
nstrucciones y cualquier instrucción
a
dicional proporcionada antes del
f
uncionamiento.
R
egistre de serie como se indica en la
placa del nombre de su generador:
N
o. de serie ___________________
DO NOT RETURN TO
S
TORE!
CALL US FIRST!
CUSTOMER HOTLINE
1
-800-445-1805
F
OR QUESTIONS OR SERVICE
I
NFORMATION
NO LO DEVUELVA A
L
A TIEND A!
¡
PRIMERO LLÁMENOS!
L
ÍNEA DIRECTA DE ATENCIÓN
A
L CLIENTE
1
-800-445-1805
P
ARA la INFORMACION de
P
REGUNTAS O SERVICIO
N
E PAS RETOURNER
A
U MAGASIN!
A
PPELEZ–NOUS D’ABORD!
A
SSISTANCE TELEPHONIQUE
A
LA CLIENTELE
1
-800-445-1805
P
OUR L'INFORMATION DE
Q
UESTIONS OU SERVICE
20
Assistance Téléphonique 1-800-445-1805Français
CARACTÉRISTIQUES DU GROUPE ELECTROGENE
CARACTÉRISTIQUES DU GROUPE ELECTROGENE
A. Tableau de commande
NOTE : Le total charge dessiné de toutes prises
ne doit pas
dépasser les limites indiquées de plaque.
B. Prise de 120 V, 20 A
20 ampères de courant peuvent être dessinés de la
prise. La charge totale doit cependant rester dans les limites
indiquées sur la plaque signalétique.
C. Prise à verrouillage de 120 V, 30 A
Un courant de pleine charge maximal peut être obtenu
à partir de cette prise, à condition qu’elle soit la seule prise
utilisée. La charge totale doit rester dans les limites
indiquées sur la plaque signalétique. Si d’autres prises sont
utilisées en même temps que celle-ci, la charge totale doit rester dans
les limites indiquées sur la plaque signalétique.
D. Protecteurs de circuit
Les prises sont protégées par un protecteur de circuit alternatif.
En cas de surcharge ou de court-circuit extérieur, le protecteur de
circuit saute. Si cela se produit, débrancher tout appareil relié au
groupe électrogène et essayer de déterminer la cause du problème
avant d’essayer de le réutiliser. Si le protecteur de circuit saute en
raison d’une surcharge, réduire la charge. REMARQUE : Le groupe
électrogène ou les appareils branchés dessus peuvent se trouver
abîmés si le protecteur de circuit saute continuellement. Appuyer
sur le bouton du protecteur de circuit pour le réenclencher.
E. Borne de Mise à Terre
F. Filtre à air
G. Commutateur On/Off (Sur/De) du moteur
H. Moteur 208 CC OHV
I. Reculer le Démarreur
J. Levier d'arrêt du moteur
K. Remplissage à huile
L. Bouchon de vidange à huile
M. Réservoir de carburant en métal
d'une contenance de 17 litres
(4.5 gallons)
N. Capuchon de Réservoir
O. Jauge de carburant
P. Arrêt du carburant
Q. Adaptateur L5-30P vers TT-30R
RV
Cet adaptateur permet de convertir la
prise 120 V, 30 A à enclenchement en
prise 120 V RV.
R. Multimètre
Lorsque la génératrice est démarrée, la valeur de tension
s’affiche d’abord.
Appuyez sur le bouton de mode et relâchez-le pour alterner
entre la valeur de tension, la fréquence, l’indicateur de
durée totale et la minuterie de fonctionnement/
maintenance.
La tension (V) affiche la tension de fonctionnement de la
génératrice.
La fréquence (F) affiche la fréquence en hertz à laquelle la
génératrice fonctionne.
La minuterie de fonctionnement/maintenance affiche la
durée en heures et minutes à chaque utilisation de la
génératrice. La minuterie de fonctionnement retourne à
00:00 lorsque la génératrice est éteinte. Un rappel de
maintenance est intégré dans cette minuterie. Lorsque la
génératrice fonctionne pendant 25 heures, la minuterie
affiche P25. Cela permet de vous rappeler de changer
l’huile après les 25 premières heures de fonctionnement.
Lorsque la minuterie de fonctionnement/maintenance
affiche P50, il est temps de nettoyer le filtre à air.
Lorsque la minuterie de fonctionnement/maintenance
affiche P100, il est temps de remplacer/nettoyer le filtre à
carburant, de nettoyer le filtre à air et de changer l’huile.
A
B
P
D
I
K
L
G
J
N
C
E
D
R
M
H
O
F
Q
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Generac PM0143250 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues