Leonton DD-0953-360 Manuel utilisateur

Taper
Manuel utilisateur
DD-0953-360
© Copyright 2023 Leonton Technologies Co., Ltd. All Rights Reserved
This document contains information, which is protected by copyright. Reproduction, adaptation or
translation without prior permission is prohibited, except as allowed under the copyright laws.
Disclaimer
Leonton Technologies, Co. Ltd. provides this manual without warranty of any kind, expressed or implied,
including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Leonton Technologies, Co. Ltd. may make improvements and/or changes to the product and/or
specifications of the product described in this manual, without prior notice. Leonton Technologies, Co. Ltd.
will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are
periodically made to the information contained herein and will be incorporated into later versions of the
manual. The information contained is subject to change without prior notice.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy. It may cause harmful interference to radio communications if the equipment is not installed and
used in accordance with the instructions. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void
the user's authority to operate the equipment.
Déclaration FCC
Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour fournir
une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. Cet
équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé et
utilisé conformément au manuel d’instruction, peut perturber la réception radio. Cependant, il n’est pas
garanti que l’équipement ne produira aucune interférence dans une installation particulière. Si cet
équipement cause des interférences nuisibles à la réception radio ou télévisée, qui peuvent être
déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à essayer de remédier au problème
en prenant les mesures suivantes:
Réorienter ou déplacer l’antenne réceptrice.
Augmenter la distance entre l’équipement et le récepteur.
Connecter l’équipement à une prise secteur sur un circuit difrent de celui utilisé par le récepteur.
Consulter le négociant ou un technicien radio/TV expérimenté.
Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de cet
appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
CE Mark Avertissement
Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en
présence d'interférences radio.
This document is the current official release manual. Please check our website (www.leonton.com) for any
updated manual or contact us by e-mail ([email protected]om).
CONTENT
OVERVIEW ................................................................................................................................... 1
Key Features ................................................................................................................................................................. 1
Package Contents ....................................................................................................................................................... 1
Safety Precaution ........................................................................................................................................................ 1
HARDWARE DESCRIPTION ...................................................................................................... 2
Physical Dimensions .................................................................................................................................................. 2
Front Panel .................................................................................................................................................................... 3
Top View ........................................................................................................................................................................ 3
LED Indicators .............................................................................................................................................................. 4
Wiring the Power Inputs ........................................................................................................................................... 5
Wiring the Power Outputs ....................................................................................................................................... 6
Grounding Note .......................................................................................................................................................... 7
MOUNTING INSTALLATION .................................................................................................... 8
DIN-Rail Mounting ..................................................................................................................................................... 8
Wall Mounting ........................................................................................................................................................... 10
HARDWARE INSTALLATION .................................................................................................. 11
Installation Steps ...................................................................................................................................................... 11
TROUBLE SHOOTING .............................................................................................................. 13
OVERVIEW
Leonton’s DD-0953 Series is a DC/DC output DIN-rail mounted power booster. It is designed in compact
size IP30 metal housing. DD-0953-360 with the booster technology is the best solution for the applications
with low voltage power source available. Besides, the -40°C to 75°C wide temperature range design makes
it perfect for operating in critical industrial environments, like automation and automotive.
Key Features
Interface & Performance
Featuring the booster technology from 9-36(up to 55) VDC power input to 53VDC
Output voltage adjustable (48V-55V) via built-in SVR
Protection: short circuit (Output) / overload (Input)
Protection: Input / Output reverse polarity protection
Protection: Input Under Voltage
LED power indicator (Input / Output)
Power Input
Power inputs contact interface are on the front
Support DC power inputs through 3-pin terminal block interface
Power Output
Support DC power output through removable 4-pin terminal block interface
DC output voltage is adjustable from 48 to 55 VDC by the adjusting knob
Certification
CE/FCC
Operating Temperature
Operating temperature model: -40°C ~ 75°C
Case/Installation
IP30 protection (not certified by UL)
DIN-Rail and Wall-Mount design
Installation in a pollution degree 2 industrial environment
Fan-less Design, cooling by free air convection
Package Contents
1 - DD-0953-360 - Unit weight: 0.388 kg (0.86 lbs.), Shipping weight: 0.516 kg (1.14 lbs.)
2 - Wall mounting brackets and screws
1 - Quick installation guide
Safety Precaution
Attention
If the DC voltage is supplied by an external circuit, please use a protection device on the power supply
input. Supply by UL Listed industrial use power. The industrial power booster’s hardware specs, ports,
cabling information, and wiring installation will be described within this user manual.
Attention
Si la tension CC est fournie par un circuit externe, veuillez utiliser un dispositif de protection sur l'entrée
d'alimentation. Fourniture par courant industriel homologué UL. Les spécifications matérielles, les ports,
les informations de câblage et l'installation du câblage du convertisseur de média industriel seront décrits
dans ce manuel d'utilisation.
Warning Labels
The caution label means that you should check the certain information on user manual when working with
the device. (Shown in Figure 1.1)
Étiquettes d'avertissement
L'étiquette d'avertissement signifie que vous devez vérifier certaines informations sur le manuel
d'utilisation lorsque vous travaillez avec l'appareil. (Montré dans la Figure 1.2)
Figure 1.1 - Caution Label
Figure 1.1 - Étiquette de mise en garde
Figure 1.2 - Hot Surface Warning Label
Figure 1.2 - Étiquette d'avertissement de surface chaude
HARDWARE DESCRIPTION
Physical Dimensions
Figure 2.1, below, shows the physical dimensions of DD-0953-360.
(W x H x D) is 30mm x 95mm x 75mm
Figure 2.1: Physical Dimensions
Front Panel
The front panel of the DD-0953-360 Industrial Power Booster is shown below in Figure 2.2.
Figure 2.2: The Front Panel
Top View
Figure 2.3, below shows the top panel of the DD-0953-360 Industrial Power Booster.
Figure 2.3: Top Panel View
Grounding Screw
4-pin removable terminal block for
DC power output
adjustable knob for output voltage control
from 48 to 55VDC
LED for power output status
LED for power input status
LED Indicators
There are LED light indicators located on the front panel of the industrial power booster that display the
power status, see below in Table 2.1.
Table 2.1: LED Indicators
LED
Color
Description
Input OK
Green
On
DC Input works normally
Off
DC input is failed
Output OK
Green
On
DC output works normally
Off
DC output is failed
Wiring the Power Inputs
Caution: Please follow the below steps to insert the power wire.
Attention: Veuillez suivre les étapes ci-dessous pour insérer leble d'alimentation.
Step 1 Insert the positive and negative wires into the +V and -V contacts on the terminal block
connector as shown below in Figure 2.4.
Figure 2.4: Power Terminal Block
Step 2 Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.5.
Figure 2.5: Wire-Clamp Screws on the Side Panel
Caution: Only use copper conductors, 125°C, tighten to 7 in-lbs (0.79 Nm). The wire gauge for
the terminal block should range between 18~20 AWG.
Attention: Utilisez uniquement des conducteurs en cuivre, 125 ° C, serrer à 7 in-lbs (0,79 Nm). Le
calibre des fils du bornier doit être compris entre 18 et 20 AWG.
Wiring the Power Outputs
Caution: Please follow the below steps to insert the power wire.
Attention: Veuillez suivre les étapes ci-dessous pour insérer leble d'alimentation.
Step 1 Insert the positive and negative wires into the PWR (V-, V-, V+, V+) contacts on the terminal
block connector as shown below in Figure 2.6.
Figure 2.6: Power Terminal Block
Step 2 Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7.
Figure 2.7: Wiring the copper conductors to the terminal block
Step 3 Rotate the knob to adjust power output voltage from 48-55VDC, as shown below in Figure
2.8.
.
Figure 2.8: Adjustable Knob for Power Output Voltage
Caution: Please adjust the knob by fine-tuning. Do not rotate too fast to cause problems with the
power supply.
Attention: Veuillez ajuster le bouton en ajustant. Ne tournez pas trop vite pour causer des
problèmes avec l'alimentation.
Caution: Only use copper conductors, 125°C, tighten to 7 in-lbs (0.79 Nm). The wire gauge for the
terminal block should range between 18~20 AWG.
Attention: Utilisez uniquement des conducteurs en cuivre, 125 ° C, serrer à 7 in-lbs (0,79 Nm). Le
calibre des fils du bornier doit être compris entre 18 et 20 AWG.
Grounding Note
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run
the ground connection from the ground screw to the grounding surface prior to connecting devices. The
grounding screw symbol is shown blow in Figure 2.9.
Figure 2.9: Grounding screw symbol
Caution: Using a shielded cable achieves better electromagnetic compatibility.
Attention: L'utilisation d'un câble blindé permet une meilleure compatibilité
électromagnétique.
MOUNTING INSTALLATION
DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial power booster from the factory. If the DIN-Rail is not on the
unit, please see Figure 3.1 to learn how to install the DIN-Rail on it.
Figure 3.1: The Rear Side of the Power Booster and Wall Mounting Bracket
Follow the steps below to learn how to hang the industrial power booster.
Step 1. Use the screws to install the DIN-Rail bracket on the rear side of the industrial power booster.
Step 2. To remove the DIN-Rail bracket, do the opposite from Step 1.
Step 3. After the DIN-Rail bracket is installed on the rear side of the power booster, insert the top of the
DIN-Rail on to the track as shown below in Figure 3.2.
Figure 3.2: Insert the Power Booster on the DIN-Rail
Step 4. Lightly pull down the bracket on to the rail as shown below in Figure 3.3.
Figure 3.3: Stable the Power Booster on DIN-Rail
Step 5. Check if the bracket is mounted tightly on the rail.
Step 6. To remove the industrial power booster from the rail, do the opposite from the above steps.
Wall Mounting
Follow the steps below to mount the industrial power booster using the wall mounting bracket as shown
below in Figure 3.4.
Step 1. Remove the DIN-Rail bracket from the industrial power booster by loosening the screws.
Step 2. Place the wall mounting brackets on the top and bottom of the industrial power booster.
Step 3. Use the screws to screw the wall mounting bracket on the industrial power booster.
Step 4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial power
booster on the wall.
Step 5. To remove the wall mount bracket, do the opposite from the steps above.
Figure 3.4: Remove DIN-Rail Bracket from the Power Booster and Install the Wall Mount Bracket
Below, in Figure 3.5 are the dimensions of the wall mounting bracket.
Figure 3.5: Wall Mounting Bracket Dimensions
HARDWARE INSTALLATION
Installation Steps
This section will explain how to install DD-0953-360.
Installation Steps
Step 1. Unpack the industrial power booster from the original packing box.
Step 2. Check if the DIN-Rail bracket is screwed on the industrial power booster.
If the DIN-Rail is not screwed on the industrial power booster, please refer to the DIN-Rail
Mounting section for DIN-Rail installation.
If you want to wall mount the industrial power booster, please refer to the Wall Mounting section
for wall mounting installation.
Step 3. To hang the industrial power booster on a DIN-Rail or wall, please refer to the Mounting
Installation section.
Step 4. Connect the power source equipment to the industrial power booster and then the power input
LED light will turn on.
If you need help on how to wire power, please refer to the Wiring the Power Inputs section.
Please refer to the LED Indicators section for LED light indication.
Step 5. Connect the industrial power booster to the powered device, e.g.: Ethernet switch…etc., and the
power output LED light will turn on.
Please refer to the LED Indicators section for LED light indication.
Step 6. When all connections are set and the LED lights all show normal, the installation is complete.
Caution: If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Attention: Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la
protection fournie par l'équipement peut être altérée.
Caution: The installation that the safety to any system incorporating the equipment is the
responsibility of the assembler of the system.
Attention: L'installation que la sécurité de tout système intégrant l'équipement est de la
responsabilité de l'assembleur du système.
Caution: This is an OPEN TYPE module and should be installed in a final safety enclosure
characteristic.
Attention: Il s'agit d'un module de TYPE OUVERT et doit être installé dans une caractéristique
finale d'enceinte de sécurité.
Caution: This device is intended for use indoor and at altitudes up to 2000 meters.
Attention: Cet appareil est destiné à être utilisé en intérieur et à des altitudes allant jusqu'à
2000 mètres.
Caution: Ambient Relative Humidity should be within the range of 5 and 95% (non-
condensing).
Attention: L'humidité relative ambiante doit être comprise entre 5 et 95% (sans condensation).
TROUBLE SHOOTING
Verify you have the right power cord or adapter. Never use a power supply or adapter with a non-
compliant DC output voltage or it will burn the equipment.
If the power indicator LED does not turn on when the power cord is plugged in, the user may have a
problem with the power cord. Check for loose power connections, power losses or surges at the
power outlet.
Please contact Leonton for technical support service, if the problem still cannot be resolved.
If the industrial power booster LED indicators are normal and the connected cables are correct, but
the packets still cannot transmit. Please check the Ethernet devices’ configuration or status of the
system.
For any repair or maintenance needs, please contact us.
LEONTON TECHNOLOGIES, CO., LTD
9F-1, No.43, Fuxing Rd., Xindian Dist.,
New Taipei City, 231,
Taiwan
TEL: +886 2 22183113
FAX: +886 2 22187391
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Leonton DD-0953-360 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues