Impecca IWA06-KS30 Mode d'emploi

Catégorie
Climatiseurs mobiles
Taper
Mode d'emploi

Ce manuel convient également à

Electronic Window Air Conditioner with Remote—User's Guide
Models:
IWA06-KR15, IWA08-KR15, IWA10-KR15, IWA12-KR15
IWA06-KS30, IWA08-KS30, IWA10_KS30, IWA12-KS30 [Energy Star]
www.impecca.com
v1.3
Read the following notices and information carefully to ensure proper operation of your air
conditioner unit.
This manual is solely provided for informational purposes and in no way constitutes a legally
binding document between the manufacturer, distributor, and end consumer. Exact appear-
ance of your unit may dier from the pictures and diagrams enclosed.
Lea las siguientes indicaciones cuidadosamente para asegurar el correcto funcionamiento
de su unidad de aire acondicionado.
Este manual se proporciona únicamente con fines informativos y de ninguna manera
constituye un documento jurídicamente vinculante entre el fabricante, distribuidor y
consumidor final. Apariencia exacta de su unidad puede diferir de las imágenes y esque-
mas adjuntos.
WARNING:
To avoid permanent damage to unit:
Ensure it is in the upright position for a MINIMUM of 6
hours and a RECOMMENDED time of 24 hours before pow-
ering on the first time.
ADVERTENCIA:
Para evitar daños permanentes a la
unidad:
Asegúrese de que está en la posición vertical durante
un mínimo de 6 horas y un tiempo recomendado de 24
horas antes de encender la primera vez.
Spanish version of this manual available for download on
www.impecca.com
ENGLISH
–iii–
TABLE OF CONTENTS
Introduction ..............................................................................................................................6
Getting To Know Your Air Conditioner ..................................................................................7
Using Your Air Conditioner .....................................................................................................7
Delay Start/Stop (Timer) ...................................................................................................... 11
Installation Instructions ....................................................................................................... 14
R1 Insulation Installation (for some models)................................................................... 16
Cleaning & Maintenance ...................................................................................................... 18
Troubleshooting .................................................................................................................... 19
Electrical Information ........................................................................................................... 21
Customer Support ................................................................................................................. 21
One-Year Limited Appliance Warranty (US) ...................................................................... 22
Garantía Limitada Por Un Año (US) ................................................................................... 23
Garantie Limitée D’un An (US) ............................................................................................ 24
ENGLISH
–4–
Plug in power plug completely.
Do not start or stop the unit by inserting or
pulling out the power plug.
Do not damage power cord or replace
with a non-original power cord.
• Otherwise, it may cause electric shock or
fire due to potential short circuit.
• It may cause electric shock or fire.
• It may cause electric shock or fire.
• If the power cord is damaged, it must
be replaced by the manufacturer or an
authorized service center or a similarly
qualified person to avoid hazard.
Do not modify power cord length.
Do not operate with wet hands or in a
damp environment.
Do not direct airflow directly at room
occupants.
• It may cause electric shock or fire. • It may cause electric shock. • This could be harmful to their health.
Always ensure eective grounding/
earthing.
Do not allow water into or onto the front of
cabinet, control panel or power cord.
Always use dedicated power outlet and
circuit breaker.
• Incorrect or missing grounding may lead to
electric shock.
• It may cause failure of unit or electric shock. • Sharing a circuit can lead to fire.
Unplug the unit if it emits strange sounds,
smells or smoke.
Do not plug unit into an electrical socket
that is loose or damaged.
Do not operate the unit while the
chassis is open or removed.
• Unit may need repair. • It may cause fire and electric shock. • It may cause electric shock.
Ensure the power cord is kept away from
any heating sources.
Do not disassemble or modify unit.
Do not use the power cord near
flammable gas or combustibles, such as
gasoline, benzene, paint thinner, etc.
• It may cause fire and electric shock. • It may cause failure and electric shock. • It may cause an explosion or fire.
Ventilate room before operating
air conditioner if there was a gas leakage.
• It may cause explosion, fire, and burns.
WARNING
READ THESE NOTICES CAREFULLY—THEY ARE IMPORTANT!
When the air filter is removed for cleaning,
avoid touching the internal metal parts of
the unit.
Do not clean the air conditioner with water.
Ventilate the room well when used
together with a stove, etc.
• It may cause an personal injury and/or
damage to the unit.
• Water may enter the unit and degrade the
insulation. It may cause an electric shock.
• An oxygen shortage may occur when
using a stove in a room with closed
windows.
When the unit is to be cleaned, power o
the unit and circuit breaker.
Do not put a pet or house plant where it
will be exposed to direct air flow.
Do not use for specialized purposes.
• Do not clean unit when power is on as it
may cause fire and electric shock and/or
personal injury.
• This could injure or be harmful
to your pet or plants.
• Do not use this air conditioner to
preserve precision devices, food, pets,
plants, and art objects.
• It may cause deterioration, etc.
CAUTION
ENGLISH
–5–
CAUTION
ELECTRICAL SAFETY
• Be sure your electrical wiring is adequate for the model you have chosen. This information can be found on
the rating label, a silver-colored sticker generally located on the right side of the cabinet.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is
important. The power cord is equipped with a three-prong
grounding plug for protection against shock hazards.
• Your air conditioner must be connected to a properly ground-
ed wall receptacle. If the wall receptacle you intend to use
is not adequately grounded or protected by a time delay
fuse or circuit breaker, have a qualified electrician install the proper
receptacle.
• Ensure the receptacle is accessible aer the unit installation.
Stop operation and remove unit from
window in severe storm or hurricane.
Hold the plug by the head of the power
plug when unplugging unit.
Unplug the power cord when not using
the unit for extended periods of time.
• Operation during a severe storm may allow
a significant amount of water to enter the
indoors.
• Pulling from the wire can cause wire to fray
leading to electric shock or fire.
• Will prevent damage to the unit.
Do not place obstacles around air-intake
vents or inside cool air outlet.
If unit is equipped with an outdoor
installation bracket, periodically ensure that
it has not become damaged.
Always insert the filters securely.
Clean filter at least once per month.
• It may cause failure of appliance.
• If bracket is damaged, the unit can fall and
cause damage, personal injury or death.
• Operation with dirty filters (or without
filters) will eect performance and may
cause damage to the unit.
Do not use strong detergent such as
wax or paint thinner to clean the unit.
Use a damp, so cloth.
Do not place heavy objects on the
power cord and ensure that the cord
is not pinched or stressed.
Do not place this window-type air
conditioner through a wall.
• Appearance may deteriorate due to change
of product color or scratching of its surface.
• There is danger of fire or electric shock.
• This will block the side vents and pre-
vent the unit from cooling properly.
CAUTION
NOTE: The power supply cord with this air conditioner
contains a current detection device designed to reduce the risk
of fire. In the event that the power supply cord is damaged, it
cannot be repaired -- it must be replaced with a cord from the
Product Manufacturer.
The power supply cord contains a current device that senses damage
to the power cord and excess current draw from the unit. To test your
current device do the following:
1. Plug in the Air Conditioner.
2. Press the TEST button. You will hear a click as the RESET button
pops out within the rubber housing and the LED will turn o.
3. Press the RESET button. You will hear a click as the button
engages and the LED will illuminate.
4. The power supply cord is now supplying electricity to the unit.
Note: Your model may have the TEST and RESET buttons on the
side or the front of the plug head.
NOTES:
• Do not use the TEST and RESET buttons to turn the unit on or o.
• If the current device fails the test or the power cord becomes dam-
aged, the entire power cord must be replaced with an equivalent
power cord and current device by a licensed electrician.
Side button
version
ENGLISH
–6–
INTRODUCTION
Thank you for purchasing this quality Impecca window air conditioner unit. To ensure
the longest life and highest energy eiciency of your unit, please carefully follow these
operating instructions. Keep these instructions in a safe place and consult them as
needed. Please note that constant enhancement and improvements to our air condi-
tioning units may mean that your model will slightly dier in appearance from the mod-
el pictured in this manual, but the actual operation and installation of the unit remains
unchanged. This manual is solely provided for informational purposes and does not
constitute a binding, legal contract.
SAFETY NOTICE:
This appliance should not be used by children or mentally/physically disabled persons with-
out strict, direct supervision by a responsible adult. Never play with or around the appliance.
SAFETY INFORMATION
Before operation, ensure your electrical installation (outlets and circuits) complies
with the power specifications found on the unit.
Before cleaning or maintaining the air conditioner, please turn o air conditioner and
unplug the unit.
Make sure the power cord isn’t kinked, bent, or under the weight of sharp or heavy
objects.
Do not pull or yank the power cord to unplug the unit or move the air conditioner.
Do not insert or unplug the power plug with wet hands.
Only use a grounded power outlet. Make sure the grounding is functional.
If the power cord is damaged, it must be replaced by the manufacturer or a qualified
technician in order to avoid fire and electrical hazards.
Should abnormal operation occur (such as a burning smell), please disconnect pow-
er cord immediately and contact your local dealer.
If nobody is present to monitor the operation of the unit, please turn it o and dis-
connect the power cord.
Do not splash or pour water on air conditioner to avoid causing a short circuit or
damage to the unit.
Do not put or hang dripping objects above the air conditioner.
Ensure the ambient temperature remains well above freezing (32°F or 0°C) to avoid
cracking or damaging the unit.
Keep heat sources away from the air conditioner.
Ensure the unit is far away from fire, inflammable, or explosive objects.
Never allow children or persons with reduced physical, sensory, or mental capabili-
ties to operate or play around the air conditioner without direct adult supervision.
Never allow children to perform cleaning or other user-maintenance operations
without direct adult supervision.
Never attempt to repair or disassemble the air conditioner by yourself.
Never insert objects into the air conditioner.
ENGLISH
–7–
OPERATING CONDITIONS
The air conditioner must be operated within the temperature range of 62°F to 95°F
(16°C to 35°C).
A perimeter of 12′′(30cm) around the air conditioner should be free of all objects.
Keep air inlet and air outlet clean and free of obstructing objects.
During operation, close doors and windows to improve cooling eect.
Please put the air conditioner at smooth and flat ground for operation to avoid noise
and vibration.
Do not tilt or turn over the air conditioner. If there’s problem, please disconnect the
power supply immediately and contact your local dealer or technical support.
GETTING TO KNOW YOUR AIR CONDITIONER
1. Upper rail
2. Cool air outlet
3. Cool air direction-
al levers
4. Fresh air vent
control (some
models)
5. Filter cover grasps
6. Control Panel
7. Outside air intake
(Do not block
these vents!)
8. Warm air intake
USING YOUR AIR CONDITIONER
FRESH AIR VENT (SOME MODELS)
When cooling, always leave the vent closed (Fig A).
When operating the unit in fan only mode, you may also open the vent (Fig B.) Another
option is opening the vent and exhaust at the same time(Fig C), which is good for re-
moving odors from the room during fan mode.
F
G
H
I
E
D
C
B
Fig A.
Fig B. Fig C.
ENGLISH
–8–
OVERVIEW OF CONTROLS FUNCTIONS
Before you begin, thoroughly familiarize yourself with the control panels as shown below
and all its functions, then follow the symbol for the functions you desire. The unit can be
controlled by the unit control panel located on the front of the device or with the remote
controller.
1. Temperature/Timer Down
2. Timer (Delay start/stop)
3. Check Filter light reset
4. Clean Air/Ionization (On Some models)
5. Function selector (Auto-Cool-Dry-Fan)
6. Energy Saver
7. Temperature/Timer Up
8. Display (Temperature/Timer)
9. Sleep mode
10. Fan Speed selector
11. Infrared Remote senor window
12. On/O
13. PMTS (On Some Models)
Note that your model's control panel may dier
slightly.
POWER ON/OFF
Press the On/O button to turn the unit on or o.
CLEAN AIR (ION) FEATURE (ON SOME
MODELS)
Available on certain models, the ion generator
creates an energized field and will help to re-
move pollen and impurities from the air, trap-
ping them in the filter.
Ion
PMTS
Control Panel
B
C
D
F
E
G
M
N
L
K
J
I
H
Ion
ENGLISH
–9–
TEMPERATURE ADJUSTMENT
Press or hold either Down or Up button until the de-
sired temperature is seen on the display. This tempera-
ture will be automatically maintained anywhere between
62° F (17° C) and 86° F (30° C).
If you want the display to read the actual room tempera-
ture, refer to the note: “To Operate on Fan Only”.
FAN SPEED ADJUSTMENT
Select the Fan Speed in four steps: Auto, Low, Med or
High. Each time the button is pressed, the fan speed
mode is shied. On Dry mode, the fan speed is controlled
at Low automatically.
OPERATING MODE (FUNCTION) SELECTION
To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected in a
sequence that goes from AUTO, COOL, DRY, and FAN. The
indicator light beside will be illuminated and will remain
on once the mode is selected.
USING AUTO FEATURE
When you set the air conditioner in AUTO mode, it will
automatically select cooling or fan only operation de-
pending on the current room temperature and the target
temperature you have set. The air conditioner will con-
trol room temperature automatically. In this mode, the
fan speed cannot be adjusted.
USING DRY MODE
In this mode, the air conditioner will generally operate in
the form of a dehumidifier. Since the conditioned space is a
closed or sealed area, some degree of cooling will continue.
FAN ONLY MODE
Use this function only when cooling is not desired, such
as for room air circulation or to exhaust stale air (on some
models). Remember to open the vent during this function,
but keep it closed during cooling for maximum cooling
eiciency. You can choose any fan speed you prefer.
During this function, the display will show the actual room
temperature, not the set temperature as in the cooling
mode. In Fan Only mode, the temperature is not adjusted.
Ion
Ion
ENGLISH
–10–
PMTS — FOLLOW ME (SOME MODELS)
Some models are equipped with a special feature that allows
the remote control to act as a thermostat. If your unit shows
this PMTS LED on the control panel, and you have the accom-
panying LCD remote control then your unit is equipped.
You must activate this feature through the remote control by
pressing the PMTS button. Once activated, it is important to
keep the remote aimed at the air conditioner and place it in
the center of the room for best results.
ENERGY SAVER MODE
This function is available on COOL mode. The fan will con-
tinue to run for 3 minutes aer the compressor shuts o.
The fan then cycles on for 2 minutes at 10-minute intervals
until the room temperature is above the set temperature,
at which time the compressor turns back on and Cooling
Starts. Note that due to modern energy saving regulations,
this mode is on by default and you must turn it o if you
want the fan to run constantly during cooling mode.
SLEEP MODE
In this mode the selected temperature will increase by 2°F
(or 2°C) 30 minutes aer the mode is selected. The tempera-
ture will then increase by another 2°F (or 2°C) aer an addi-
tional 30 minutes. This new temperature will be maintained
for 6 hours before it returns to the originally selected tem-
perature. This ends the Sleep mode and the unit will contin-
ue to operate as originally programmed. The Sleep mode
program can be canceled at any time during operation by
pressing the Sleep button again.
CHECK FILTER
This feature is a reminder to clean the Air Filter for more
eicient operation. The LED (light) will illuminate aer 250
hours of operation. To reset aer cleaning the filter, press
the Check Filter button and the light will go o. See section
under Cleaning and Maintenance for how to clean the filter.
Note: Your filter may need to be cleaned much more oen
in especially dusty environments and may not need to be
cleaned as oen in especially clean environments. The 250
hour indicator is just there as a reminder.
Ion
PMTS
ENGLISH
–11–
DELAY START/STOP (TIMER)
The timer buttons enable two separate functions: one to
automatically start the unit within a 24 hour period of time
and another to automatically turn o the unit within a 24 hour
period of time. These functions are called, respectively, AUTO
ON and AUTO OFF.
AUTO ON INSTRUCTIONS:
1. Press the TIMER button twice, or until the TIMER ON
LED on the air conditioner's control panel should illumi-
nate. The air conditioner's display shows the last Auto-On
setting (if any). Now you are ready to reset the Auto-On time
to START the operation.
2. Press either the orbuttons to set desired
Auto-On time. Each time you press the button, the time will increase in 30 minute
increments, up to 10 hours, then in 1 hour increments up to 24 hours.
3. Aer setting the TIMER ON, there will be a one-half second delay before the remote
controller transmits the signal to the air conditioner. Then, aer approximately
another 2 seconds, the time setting will disappear from the unit's display and the
set temperature will re-appear on the display window. The Timer ON LED should
remain illuminated.
AUTO OFF INSTRUCTIONS:
1. Press the TIMER button once, or until the TIMER OFF LED on the air condition-
er's control panel should illuminate. The air conditioner's display shows the last
Auto-O setting (if any). Now you are ready to reset the Auto-O time to START the
operation.
2. Press either the orbuttons to set desired Auto-O time. Each time you press
the button, the time will increase in 30 minute increments, up to 10 hours, then in
1 hour increments up to 24 hours.
3. Aer setting the TIMER ON, there will be a one-half second delay before the remote
controller transmits the signal to the air conditioner. Then, aer approximately
another 2 seconds, the time setting will disappear from the unit's display and the
set temperature will re-appear on the display window. The Timer OFF LED should
remain illuminated.
Notes: It is possible to set both and Auto-On and Auto-O program at the same time. All times that are set are
the time from the moment of setting. So if you were to set a delay of 5 hours to turn on and immediately aer
set a delay of 6 hours to turn o, then the unit will operate for a total of 1 hour in 5 hours time from now.
All programs are erased aer their time elapses, so they will not repeat again the next day until reprogrammed.
Important: If you use a separate timer to obtain more control (such as turning on and o at a specific time every
day), the unit will remember its previous mode. It may, however, return to energy saver mode by default. If you do
use a timer, be sure that it is a heavy -duty grounded (three-prong) timer that is rated for the appropriate amper-
age.
ENGLISH
–12–
1 2
3
7
9
8 11
4
3
5
6
10
Phillips Screwdriver
Level
Scissors Pencil Tape Measure
PRE-INSTALLATION INSTRUCTIONS
REQUIRED TOOLS (NOT INCLUDED)
INCLUDED PARTS & ACCESSORIES*
1. Air conditioning unit
2. Flexible window filler panels
3. Upper Rail (may already be attached)
4. Upper Rail seal (may already be at-
tached to bottom of rail)
5. Foam sash seal (no adhesive)
6. Foam seal (with adhesive)
7. Upper Rail Screws (x4)
8. Screws (x6)
9. Frame lock
10. Window security bracket
11. User’s manual and Remote Manual
*Note: The parts and appearance of parts
included with your unit may vary.
ENGLISH
–13–
WINDOW REQUIREMENTS
Your air conditioner is designed
to install in a standard double
hung windows with opening
widths of 23 to 36 inches
(584mm to 914mm).
*For 6000 and 8000 BTU models,
you need a height of 14 inches
(356mm). For 10,000 and 12,000
BTU models, you need a height
of 15½ inches (394mm).
STORM WINDOW MODIFICATIONS
If you have storm windows, the exterior window frame will be slightly higher than the
windowsill, which results in an air conditioning unit that is slanted inward and may
cause water condensation to enter the room interior. Perform these modifications to
ensure proper operation of your unit. If you have a standard window, skip this step:
1. Cut a 2” thick piece of wood to the length of the interior window width.
2. Verify that the wood is level with or up to 0.5” (1cm) higher than the exterior
storm-window frame.
3. Fasten the wood with screws to the windowsill and proceed with mounting.
H*
Wooden Windows
INTERIOR
WALL
INNER
WINDOW SILL
EXTERIOR
WALL
OFFSET
5
8
4m
m
-
9
14
m
m
2
3
-
3
6
Exterior Wall
Board thickness
should be as required
for proper pitch and
run along the entire
window sill. Fasten
with nails or screws.
Storm Window
or other obstruction
1½” min
(38 mm)
ENGLISH
–14–
INSTALLATION INSTRUCTIONS
Use caution when unpacking and installing. Sharp edges can cause injury.
Appearance of unit in these diagrams is for illustrative purposes only and may not precisely
reflect your unit’s design.
STEP 1: INSTALLING THE UPPER RAIL (IF NOT ALREADY ATTACHED)
1. Your upper rail may have come with the upper rail seal already aixed to the bottom
of the rail. If it is packaged separately, peel the backing o and aix it to the bottom
of the rail ensuring that the holes in the seal match up with the screw holes in the
rail. (Fig. A)
2. Use the 4 screws (included) to attach the upper rail to the pre-drilled holes on the
top of the cabinet as shown in Figure B. Ensure that the higher part of the rail is
facing the front of the air conditioning unit.
(Fig. B)
Note: Be sure to use all four screws when attaching
the top rail.
STEP 2: MOUNTING THE FLEXIBLE FILLER PANELS
1. Note the “Le” and “Right” markings on the panels.
2. Extend the flexible part of the filler panel past the filler panel’s frame
3. Slide the T-section into the side guide rails on the le and right of the unit.
4. Gently insert the upper and lower ends of the panel frame into the upper and lower
rail channels on the air conditioning unit.
1
2
T-section
Upper Rail
Lower Rail
Fig.B
Upper Rail seal
Upper Rail
Fig. A
ENGLISH
–15–
STEP 3: FOAM SEAL ON WINDOW FRAME
Aix the foam seal (with adhesive G ) to the bottom of
the window sash.
STEP 4: MOUNT THE UNIT IN THE WINDOW
FRAME
1. With the help of another person, center the unit on the
windowsill. The lower rail should be completely flush
with the windowsill. Gently lower the window until it
holds the upper rail in place. The chassis and frames are
configured to allow for a natural pitch towards the outside of about 3-5°.
2. Extend the window fillers to the right and le edge of the window.
3. Fasten the upper rail and top corners of the window filler panels to the window
frame with screws. Use the frame locks to attach the bottom corners to the window-
sill.
ENGLISH
–16–
STEP 5: SECURING THE WINDOW
To keep the window from
being unintentionally opened
and risk damaging the unit or
injuring passersby, use one
type C screw to fasten the se-
curity bracket to the window.
If your window frame is plastic
(PVC), fasten the bracket to the
side of the window frame (De-
tail 1)If your window is made
of wood, fasten the bracket into the closed upper window sash (Detail 2).
STEP 6: INSULATING FOAM SASH SEAL
Prevent warm or cold
air from entering in
between the partially
opened window and
the closed upper
window by placing the
non-adhesive foam
sash seal in between
the window sash and
the glass pane.
R1 INSULATION INSTALLATION (FOR SOME MODELS)
"R1" is the name given to special additional insulation that applies to Energy Star certi-
fied models manufactured aer a certain cut-o date. If your model fits this criterion,
you will have found a weather stripping foam and additional panels that fit over the
side curtains among the parts
included with your air condi-
tioner.
WEATHER STRIPPING
In order to minimize air
leaks between the room air
conditioner and the window
opening, trim the weath-
er stripping with a proper
length, peel o the protective
backing and plug any gaps if
needed.
1
2
ENGLISH
–17–
R1 SIDE CURTAIN COVER INSTALLATION (SOME MODELS)
1. Aer the unit is installed in the window, measure the width of each side's exposed
filler panel as shown in the diagram.
2. Cut the insulation panel to size for each side of the side curtain.
3. Slide the R1 panel into place
or
ENGLISH
–18–
CLEANING & MAINTENANCE
SAFETY WARNING
To avoid electric shock, fire, damage, or injury while performing maintenance on your
unit:
Always turn o and disconnect the air conditioner from electric power.
Never submerge the unit in water or spray liquids directly on the unit.
Never use solvents or other flammable or volatile liquids (examples: paint thinner,
acetone, gasoline, etc.) to clean the air conditioner.
PRE-COOLING SEASON UNIT CHECK
Before using your air conditioner in the warm summer months, always perform the
following verifications to ensure reliable, eicient operation:
Check the air inlets and outlets for any foreign objects (example: leaves, sticks, small
toys, etc.)
Check that the electrical cord and socket are not damaged, bent, or fraying.
Check the filter and clean if necessary.
POST-COOLING SEASON UNIT CHECK
Aer using your air conditioner in the warm summer months, always perform the fol-
lowing verifications:
Disconnect the unit electrical power.
Clean the filter and unit casing.
Remove dust and other objects on the unit.
Discard any accumulated water inside the unit (see section about drainage).
LONG-TERM STORAGE
Should you place your unit in long-term storage, perform all of the post-season checks
listed above and perform the following additional steps:
Wrap the electrical cord loosely around the unit.
Cover the unit with a sheet or cloth to prevent dust buildup inside during storage.
• WARNING: Never store the unit up-side down or on its side. This can permanently
damage the compressor.
DISPOSAL INFORMATION
Most unit packaging materials are recyclable. Please dispose of them according to
local recycling guidelines.
If you wish to discard the unit, contact your local authorities for specific appliance
disposal instructions. If the unit is functional and in good repair, but you wish to dis-
pose of it, consider donating it to a local charity.
ENGLISH
–19–
CLEANING THE OUTER HOUSING AND INTAKE GRILLE
If dust has accumulated on the unit, use a so, dry dusting cloth to wipe it o. If grease
or other harder to remove substances is on the unit, use a wrung-out cloth dampened
with warm, soapy water. Use a so brush to clean o the grille.
CLEANING THE FILTER
For energy eicient operation, your filter should be cleaned at least once a month. Units
in dusty environments may require more frequent filter cleaning.
The filter removal handles are located on both sides of the unit (see "Getting to know
your air conditioner" diagram, number F
above).
Remove it by sliding it out.
Use a vacuum cleaner or rinse the filter in
cold water. If the filter is particularly dirty
(such as grease buildup), wash and gently
scrub the filter in a bath of warm (not hot)
soapy water. Let the filter completely dry
in a shady place; exposing the filter to
direct sunlight can cause deformation.
Aer the filter is clean and completely dry, re-insert the filter.
Note: To avoid deformation and fire risk, never dry the filter with a heat source, such as a
hair dryer, fireplace, or heater.
TROUBLESHOOTING
PROBLEM / POSSIBLE CAUSES
THE AIR CONDITIONER DOES NOT FUNCTION AT ALL
Is the power cable properly inserted into a functioning, grounded outlet?
Is there a power failure such as a blown fuse or tripped circuit breaker?
Is the ambient temperature lower than 61°F (16°C)? A safety device prevents the unit
from cooling the room to even lower temperatures.
INSUFFICIENT COOLING
Is the unit temperature set properly?
Is the air filter dirty?
Are doors or windows open?
Is the room directly exposed to sunlight or are there other heat sources in the room?
Are there a large number of people in the room?
ENGLISH
–20–
WATER BUILD-UP IN THE UNIT, SPLASHING NOISE
This is not a problem. This self-evaporative unit is designed allow condensate to
build up in the rear of the unit during cooling and dry modes. The rear fan then runs
through the pool of water, splashing it upon the evaporator coils, helping to cool
them down. This makes the unit more eicient and eliminates the need to hook up a
drain hose.
THE AIR CONDITIONER UNIT STARTS AND STOPS VERY FREQUENTLY.
Verify the rating of your electrical system and outlets. You may need a qualified elec-
trician to troubleshoot and upgrade your electrical circuits if your air conditioner unit
exceeds the rated capacity.
FOG BLOWS OUT DURING COOLING
In warm, high humidity environments this may naturally occur. Continued cooling
will remove excess humidity from the room and the fog will disappear.
THE UNIT EMITS A STRANGE SMELL
This may be caused by residue from cooking and cigarette smoke, etc. that remain in
the air conditioning unit. Eliminated the source of the smell and clean the filter.
THE UNIT MAKES LOUD OR UNUSUAL NOISES AND VIBRATIONS
Ensure that the unit is installed according to the installation instructions above.
THERE IS A “SQUEALING” NOISE
The cycling of the refrigerant inside the unit can temporarily cause this noise.
THERE IS A “PATTING” NOISE
This is oen caused by heat expansion in the plastic parts.
CONDENSATION FORMS AT THE COOL AIR OUTLET
High humidity environments may cause condensation at the air flow output. Wipe
the condensation o with a sponge or dry cloth.
IF ANY OF THE FOLLOWING PHENOMENA OCCUR DESPITE THE ABOVE TROU-
BLESHOOTING TECHNIQUES, PLEASE TURN OFF THE UNIT AND DISCONNECT
THE POWER CORD IMMEDIATELY AND CONTACT TECHNICAL SUPPORT OR A
QUALIFIED TECHNICIAN:
The fuse blows or circuit breaker trips frequently.
The power cable is abnormally hot.
The insulation of the power cable is ripped, shred or torn.
The unit controls do not work.
The unit produces abnormal noises.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Impecca IWA06-KS30 Mode d'emploi

Catégorie
Climatiseurs mobiles
Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues