Dell PowerEdge 2970 Guide de démarrage rapide

Taper
Guide de démarrage rapide
www.dell.com | support.dell.com
Dell™ PowerEdge™ 2970 Systems
Getting Started With
Your System
Guide de mise en route
Primeiros passos com o sistema
Procedimientos iniciales con el sistema
Model EMS01
www.dell.com | support.dell.com
Dell™ PowerEdge™ 2970 Systems
Getting Started With
Your System
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.; AMD and AMD Opteron are registered trademarks of
Advanced Micro Devices; Microsoft, Windows, and Windows Server are registered trademarks of Microsoft Corporation; Novell and NetWare
are registered trademarks of Novell, Inc.; Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc.; SUSE is a registered
trademark of Novell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Model EMS01
January 2007 P/N MN535 Rev. A00
Getting Started With Your System 3
System Features
This section describes the major hardware and software features of your system. It also provides
information about other documents you may need when setting up your system and how to obtain
technical assistance.
One or two dual-core AMD Opteron™ processors. One or two quad-core AMD Opteron™
processors (when available).
A minimum of 1 GB (single-processor systems) or 2 GB (two-processor systems) of 667-MHz
registered parity DDR-II memory modules. Memory is upgradable to a maximum of 32 GB
(two-processor systems) by installing combinations of 512-MB, 1-GB, 2-GB, or 4-GB memory
modules in the eight memory module sockets on the system board. (64 GB of memory will be
supported when 8 GB memory modules are available.)
Support for up to eight 2.5-inch, internal hot-pluggable Serial Attached SCSI (SAS) or
SATA hard drives.
The optional media bay provides support for an optional half-height tape backup unit (TBU)
and an optional slim-line 1.44-MB diskette drive.
An optional slim-line IDE CD, DVD, or combination CD-RW/DVD drive.
NOTE: DVD devices are data only.
An intrusion switch that signals the appropriate systems management software if the cover
is opened.
Up to two hot-pluggable, 750-W power supplies in an optional 1 + 1 redundant configuration.
Four hot-pluggable system cooling fans.
The system board includes the following features:
A left riser card that has one full-length PCIe x8 lane slot and one half-length PCIe x4 lane slot.
A center riser card that has one half-length PCIe x8 lane slot.
A dedicated slot for an integrated SAS host bus adapter, which supports up to four 2.5-inch SAS
or SATA hard drives, or an optional RAID controller card with 256 MB of cache memory and
a RAID battery, which supports up to eight 2.5-inch SAS or SATA hard drives.
NOTE: System boot is not supported from an external device attached to a SAS or SCSI adapter,
including SAS 5/E, PERC 5/E, or PERC 4e/DC. See support.dell.com for the latest support information
about booting from external devices.
Two integrated Gigabit Ethernet NICs, capable of supporting 10-Mbps, 100-Mbps,
and 1000-Mbps data rates.
4 Getting Started With Your System
Four external USB 2.0-compliant connectors (two on the front and two on the back) supporting
a diskette drive, a DVD-ROM drive, a keyboard, a mouse, or a USB flash drive.
One internal USB 2.0-compliant connector supporting an optional bootable USB flash drive
for customized boot configurations.
Optional remote access controller (RAC) for remote systems management.
An integrated VGA-compatible video subsystem based on an integrated ATI ES1000 33-MHz PCI
video controller. The video subsystem includes 32MB of graphics memory and supports various
2D graphics video modes. Maximum resolution is 1600x1200 with 65,536 colors. (When the optional
RAC is installed, the maximum resolution of the integrated video subsystem is 1280x1024.)
Systems management circuitry that monitors operation of the system fans as well as critical system
voltages and temperatures. The systems management circuitry works in conjunction with the systems
management software.
Standard Baseboard Management Controller (BMC) with serial and LAN access.
Back-panel connectors include one serial, one video, two USB, and two NIC connectors.
Front-panel connectors include a video and two USB connectors.
Front-panel 1x5 LCD for system ID and error messaging.
System ID button on the front and back panels.
For more information about specific features, see Technical Specifications.
Supported Operating Systems
Microsoft
®
Windows Server
®
2003 R2 Standard and Enterprise Editions (SP1 and later)
Microsoft Windows Server 2003 R2 Standard and Enterprise x64 Editions (SP1 and later)
•Red Hat
®
Enterprise Linux
®
AS and ES (Version 4) (x86)
•Red Hat
®
Enterprise Linux
®
AS and ES (Version 4) (x86_64)
Red Hat Enterprise Linux Server 5 (x86)
Red Hat Enterprise Linux Server 5 (x86_64)
•SUSE
®
Linux Enterprise Server 10 (x86_64)
NOTE: For the latest information on supported operating systems, see www.dell.com.
Getting Started With Your System 5
Other Information You May Need
CAUTION: The Product Information Guide provides important safety and regulatory information.
Warranty information may be included within this document or as a separate document.
The
Rack Installation Guide
or
Rack Installation Instructions
included with your rack solution
describes how to install your system into a rack.
The
Hardware Owner’s Manual
provides information about system features and describes how
to troubleshoot the system and install or replace system components.
CDs included with your system provide documentation and tools for configuring and managing
your system.
Systems management software documentation describes the features, requirements, installation,
and basic operation of the software.
Operating system documentation describes how to install (if necessary), configure, and use
the operating system software.
Documentation for any components you purchased separately provides information to configure
and install these options.
Updates are sometimes included with the system to describe changes to the system, software,
and/or documentation.
NOTE: Always check for updates on support.dell.com and read the updates first because they often
supersede information in other documents.
Release notes or readme files may be included to provide last-minute updates to the system or
documentation or advanced technical reference material intended for experienced users or technicians.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does not perform as expected,
see your Hardware Owner’s Manual.
Dell™ Enterprise Training and Certification is available; see www.dell.com/training for more
information. This service may not be offered in all locations.
Installation and Configuration
CAUTION: Before performing the following procedure, read and follow the safety instructions and important
regulatory information in your Product Information Guide.
This section describes the steps to set up your system for the first time.
6 Getting Started With Your System
Unpacking the System
Unpack your system and identify each item.
Keep all shipping materials in case you need them later.
Installing the Rails and System in a Rack
Once you have read the "Safety Instructions" located in the rack installation documentation
for your system, install the rails and the system in the rack.
See your rack installation documentation for instructions on installing your system in a rack.
Getting Started With Your System 7
Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to plug into
each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.
Connecting the Power
Connect the monitor’s power cable to the monitor (optional), and connect the system’s power
cable(s) to the system.
8 Getting Started With Your System
Installing the Power Cord Retention Bracket
Attach the power cord retention bracket on the right bend of the power supply handle. Bend
the system power cable into a loop as shown in the illustration and attach to the bracket’s cable
clasp. Repeat the procedure for the second power supply.
Plug the other end of the power cables into a grounded electrical outlet or a separate power source
such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
Turning on the System
Turn on the system and monitor (optional).
With the bezel removed, press the power button on the system and the monitor. The power
indicators should light. Adjust the monitor's controls until the displayed image is satisfactory.
Getting Started With Your System 9
Installing the Bezel
Install the bezel (optional).
Complete the 0perating System Setup
If you purchased a preinstalled operating system, see the operating system documentation that ships with
your system. To install an operating system for the first time, see the Quick Installation Guide. Be sure the
operating system is installed before installing hardware or software not purchased with the system.
Technical Specifications
Processor
Processor type One or two dual-core AMD Opteron processors
One or two quad-core AMD Opteron processors
(when available)
Expansion Bus
Bus type PCIe
Expansion slots
Center riser:
PCIe
One x8 full-height, half-length 3.3-V slot
Left riser
PCIe option:
One x8 full-height, full-length 3.3-V slot
One x4 full-height, half-length 3.3-V slot
10 Getting Started With Your System
Memory
Architecture 667-MHz registered parity DDR-II memory
modules
Memory module sockets Eight 240-pin
Memory module capacities 512 MB, 1 GB, 2 GB, or 4 GB
(8 GB when available)
Minimum RAM 1 GB (one processor) or 2 GB (two processors)
Maximum RAM 16 GB (one processor) or 32 GB (two processors)
(32 GB (one processor) or 64 GB (two processors)
when 8 GB memory modules are available)
Drives
Hard drives Up to eight 2.5-inch, hot-plug SAS or SATA
internal drives
Diskette drive One optional slimline 1.44-MB
External optional USB 1.44-MB
Optical drive One optional slimline IDE CD, DVD,
or combination CD-RW/DVD
NOTE: DVD devices are data only.
External optional USB DVD
Tape drive One optional internal half-height tape backup
device
Flash drive External optional USB
Internal optional USB
Connectors
Back
NIC
Two RJ-45 (for integrated 1-GB NICs)
Serial
9-pin, DTE, 16550-compatible
USB
Two 4-pin, USB 2.0-compliant
Video
15-pin VGA
Front
Video
15-pin VGA
USB
Two 4-pin, USB 2.0-compliant
Internal
USB
One 4-pin, USB 2.0-compliant
Getting Started With Your System 11
Video
Video type ATI ES1000 video controller; VGA connector
Video memory 32 MB
Power
AC power supply (per power supply)
Wattage
750 W
Voltage
85–264 VAC, autoranging, 47–63 Hz
Heat dissipation
2697 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 55 A per power supply for
10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
RAID battery (optional)
4.1-V lithium ion
Physical
Rack
Height
8.656 cm (3.40 in)
Width
44.7 cm (17.6 in)
Depth
75.68 cm (29.79 in)
Weight (maximum configuration)
26.76 kg (59 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
12 Getting Started With Your System
Relative humidity
Operating
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing) with a maximum
humidity gradation of 10% per hour
Maximum vibration
Operating
0.26 Grms at 5–350 Hz in operational
orientations
Storage
1.54 Grms at 10–250 Hz in all orientations
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms
in the operational orientation
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Environmental (continued)
www.dell.com | support.dell.com
Systèmes Dell™ PowerEdge™ 2970
Guide de mise en route
Remarques, avis et précautions
REMARQUE : une REMARQUE indique des informations importantes qui peuvent vous aider à mieux utiliser
votre ordinateur.
AVIS : un AVIS vous avertit d'un risque de dommage matériel ou de perte de données et vous indique comment éviter
le problème.
PRÉCAUTION : une PRÉCAUTION indique un risque potentiel d'endommagement du matériel, de blessure corporelle
ou de mort.
____________________
Les informations contenues dans ce document peuvent être modifiées sans préavis.
© 2007 Dell Inc. Tous droits réservés.
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Inc. est strictement interdite.
Marques utilisées dans ce document : Dell et le logo DELL sont des marques de Dell Inc. ; AMD et AMD Opteron sont des marques déposées
de Advanced Micro Devices ; Microsoft, Windows et Windows Server sont des marques déposées de Microsoft Corporation ; Novell et NetWare
sont des marques déposées de Novell, Inc. ; Red Hat et Red Hat Enterprise Linux sont des marques déposées de Red Hat, Inc. ; SUSE est une
marque déposée de Novell Inc.
Tous les autres noms de marques et marques commerciales utilisés dans ce document se rapportent aux sociétés propriétaires de ces marques et de
ces noms ou à leurs produits. Dell Inc. décline tout intérêt dans l'utilisation des marques déposées et des noms de marques ne lui appartenant pas.
Modèle EMS01
Janvier 2007 P/N MN535 Rev. A00
Guide de mise en route 15
Caractéristiques du système
Cette section décrit les principales caractéristiques du système sur le plan matériel et logiciel.
Elle contient également des informations sur les autres documents utiles à la configuration du système
et sur l'obtention d'assistance technique.
Un ou deux processeurs double-cœur AMD Opteron™. Un ou deux processeurs quadruple-coeur
AMD Opteron™ (selon disponibilité).
Barrettes de mémoire DDR-II à registres et avec parité, représentant un minimum de 1 Go
(systèmes monoprocesseur) ou 2 Go (systèmes bi-processeur) et cadencées à 667 MHz.
La mémoire est extensible à un maximum de 32 Go (systèmes bi-processeur) via l'installation
de combinaisons de barrettes de 512 Mo, 1 Go, 2 Go ou 4 Go dans les huit emplacements
mémoire de la carte système. Lorsque des barrettes de 8 Go seront disponibles, il sera possible
de prendre en charge 64 Go de mémoire.
Prise en charge de huit disques durs SAS (Serial-Attached SCSI) ou SATA internes de 2,5 pouces,
enfichables à chaud.
La baie de média en option permet également d'installer une unité de sauvegarde sur bande
(TBU) mi-hauteur et un lecteur de disquette slim de 1,44 Mo, tous deux disponibles en option.
Un lecteur de CD ou de DVD IDE slim, ou un lecteur combo CD-RW/DVD
(tous deux en option).
REMARQUE : les périphériques DVD sont uniquement des périphériques de données.
Un détecteur d'intrusion qui transmet une alerte aux logiciels de gestion des systèmes appropriés
en cas d'ouverture du capot de l'ordinateur.
Jusqu'à deux blocs d'alimentation de 750 W enfichables à chaud dans une configuration
redondante 1+1 (facultative).
Quatre ventilateurs système enfichables à chaud.
La carte système offre les caractéristiques suivantes :
Carte de montage de gauche comprenant un logement PCIe x8 pleine longueur et un logement
PCIe x4 mi-longueur.
Carte de montage centrale comprenant un logement PCIe x8 mi-longueur.
Logement dédié pouvant recevoir soit un adaptateur de bus hôte SAS intégré prenant en charge
jusqu'à quatre disques durs SAS ou SATA de 2,5 pouces, soit un contrôleur RAID en option
avec 256 Mo de mémoire cache et une batterie RAID. Ce contrôleur prend en charge jusqu'à
huit disques durs SAS ou SATA de 2,5 pouces.
REMARQUE : le démarrage du système à partir d'un périphérique externe connecté à une carte SAS
ou SCSI n'est pas pris en charge (cartes SAS 5/E, PERC 5/E et PERC 4e/DC incluses). Voir le site
support.dell.com pour obtenir les informations les plus récentes concernant le démarrage à partir
de périphériques externes.
16 Guide de mise en route
Deux NIC Ethernet Gigabit intégrés pouvant prendre en charge des débits de données
de 10, 100 et 1000 Mbps.
Quatre connecteurs USB 2.0 externes (deux à l'avant et deux à l'arrière) pour la connexion d'un
périphérique externe (lecteur de disquette ou de DVD-ROM, clavier, souris ou lecteur flash USB).
Un connecteur USB 2.0 interne prenant en charge un lecteur flash USB amorçable (en option).
Ce dernier peut être utilisé pour créer des configurations d'amorçage personnalisées.
Un contrôleur d'accès à distance (RAC) en option, pour la gestion à distance des systèmes.
Un sous-système vidéo intégré compatible VGA, avec contrôleur vidéo ATI ES1000 intégré à 33 MHz.
Ce sous-système dispose de 32 Mo de mémoire graphique avec prise en charge de divers modes
graphiques en 2D. La résolution maximale est de 1600 x 1200 avec 65 536 couleurs. Si le contrôleur
RAC en option est installé, la résolution maximale du sous-système vidéo intégré est de 1280 x 1024.
Des circuits intégrés de gestion de systèmes surveillant le fonctionnement des ventilateurs, ainsi que
les tensions et les températures critiques. Ces circuits de surveillance fonctionnent de pair avec
les logiciels de gestion de systèmes.
Un contrôleur BMC standard avec accès série et réseau local.
Le panneau arrière contient un connecteur vidéo, un port série, deux connecteurs USB et
deux connecteurs de NIC.
Le panneau avant comprend un connecteur vidéo et deux connecteurs USB.
Un écran LCD 1x5 sur le panneau avant, affichant l'ID du système et les messages d'erreur.
Un bouton d'ID du système sur les panneaux avant et arrière.
Pour plus d'informations sur des caractéristiques spécifiques, voir “Spécifications techniques”.
Systèmes d'exploitation pris en charge
Microsoft
®
Windows Server
®
2003 R2, Standard Edition et Enterprise Edition (SP1 et suivants)
Microsoft Windows Server 2003 R2 64 bits, Standard Edition et Enterprise Edition (SP1 et suivants)
•Red Hat
®
Enterprise Linux
®
AS et ES (version 4, x86)
•Red Hat
®
Enterprise Linux
®
AS et ES (version 4, x86_64)
Red Hat Enterprise Linux Server 5 (x86)
Red Hat Enterprise Linux Server 5 (x86_64)
•SUSE
®
Linux Enterprise Server 10 (x86_64)
REMARQUE : pour obtenir les informations les plus récentes sur les systèmes d'exploitation pris en charge,
rendez-vous sur le site www.dell.com.
Guide de mise en route 17
Autres informations utiles
PRÉCAUTION : le document Product Information Guide (Guide d'informations sur le produit) contient
d'importantes informations se rapportant à la sécurité et aux réglementations. Les informations sur la garantie
se trouvent soit dans ce document, soit à part.
Les documents
Rack Installation Guide
(Guide d'installation du rack) et
Rack Installation Instructions
(Instructions d'installation du rack) fournis avec la solution rack décrivent l'installation du système.
Le document
Hardware Owner's Manual
(Manuel du propriétaire) contient des informations sur
les caractéristiques du système, ainsi que des instructions relatives au dépannage et à l'installation
ou au remplacement de composants.
Les CD fournis avec le système contiennent des documents et des outils relatifs à la configuration
et à la gestion du système.
La documentation du logiciel de gestion des systèmes comprend des renseignements sur
les fonctionnalités, les spécifications, l'installation et le fonctionnement de base du logiciel.
La documentation du système d'exploitation indique comment installer (au besoin), configurer
et utiliser le système d'exploitation.
La documentation fournie avec les composants achetés séparément contient des informations
permettant de configurer et d'installer ces options.
Des mises à jour sont parfois fournies avec le système. Elles décrivent les modifications apportées
au système, aux logiciels ou à la documentation.
REMARQUE : vérifiez toujours si des mises à jour sont disponibles sur le site support.dell.com et lisez-les
en premier, car elles remplacent souvent les informations contenues dans les autres documents.
Des notes de version ou des fichiers lisez-moi (readme) sont parfois fournis ; ils contiennent des mises
à jour de dernière minute apportées au système ou à la documentation, ou des documents de référence
technique avancés destinés aux utilisateurs expérimentés ou aux techniciens.
Obtention d'une assistance technique
Si vous ne comprenez pas une procédure décrite dans ce guide ou si le système ne réagit pas
comme prévu, consultez le document Hardware Owner's Manual (Manuel du propriétaire).
Des formations et certifications Dell™ Enterprise sont disponibles. Pour plus d'informations,
consultez le site www.dell.com/training. Ce service n'est disponible que dans certains pays.
Installation et configuration
PRÉCAUTION : avant de commencer la procédure suivante, lisez et appliquez les consignes concernant
la sécurité et les réglementations, que vous trouverez dans le document Product Information Guide
(Guide d'informations sur le produit).
Cette section décrit les étapes à exécuter lors de la configuration initiale du système.
18 Guide de mise en route
Déballage du système
Sortez le système de son emballage et identifiez chaque élément.
Conservez les matériaux d'emballage au cas où vous en auriez besoin ultérieurement.
Installation des rails et du système dans un rack
Commencez par lire les consignes de sécurité qui se trouvent dans la documentation
d'installation du rack, puis installez les rails et le système dans le rack.
Consultez la documentation d'installation du rack pour obtenir les instructions appropriées.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Dell PowerEdge 2970 Guide de démarrage rapide

Taper
Guide de démarrage rapide