Honeywell L510 Mode d'emploi

Taper
Mode d'emploi
1
L510 Lamp Controller
Overview
The L510 Lamp Controller is designed for the hospitality industry to provide convenient switched and dimming
control of several different load types, including; incandescent, CFL and LEDs. By doing this, it converts any
standard lamp into a remotely controlled lamp with the ability to
create scenic and mood lighting. The L510 is able to participate in
Honeywell’s overall Energy Management System (EMS) to provide
energy savings along with enhanced guest experience.
A typical application would include a L510 controlling scenic lighting
around a headboard of a guestroom bed. To provide this control, the
L510 is equipped with an INNCOM WBI relay, Triac or FET actuator
and communicates via the on-board 2.4Ghz radio over the INNCOM
DeepMesh network. The L510 which is controlling the lamp can be
controlled by an INNCOM MODEVA or EVORA switch as well as
also be controlled locally. Other applications include; desk and floor
lamp control as well as wall sconce control.
.
Part Numbers
PART NUMBERS DESCRPTION
201-7050 Relay Actuator RF Lamp Controller, 120-240VAC, 500W
201-7051 Triac Dimmer RF Lamp Controller, 120VAC, 650W
201-7052 FET Dimmer RF Lamp Controller, 120VAC, 350W
System Layout
Figure
1
L510 Lamp Controller
Load Ratings
Model
Rating
Voltage
Freq
Power / Amperes
Type of Load
201-7050
(Relay)
120-240 Vac
50/60 Hz 4.1 A Resistive
120-240 Vac 50/60 Hz 4.1 A General Purpose
120-240 Vac 50/60 Hz 500 W Tungsten / ELV
120-240 Vac 50/60 Hz 250 VA Electric Ballast
120-240 Vac 50/60 Hz 1/10 HP Motor
201-7051
(Triac)
120 Vac 60 Hz 2.9 A Resistive
120 Vac 60 Hz 2.9 A General Purpose
120 Vac 60 Hz 650W Tungsten / ELV
120 Vac 60 Hz 250 VA Electronic Ballast
120 Vac 60 Hz 1/10 HP Motor
201-7052
(FET)
120 Vac 60 Hz 2.9 A Resistive
120 Vac 60 Hz 2.9 A General Purpose
120 Vac 60 Hz 350 W Tungsten / ELV
120 Vac 60 Hz 250 VA Electronic Ballast
Product Specification
Parameter
Specification
Range / Value
S5 Bus
Data Rate 2550bps
Range 50ft
Max Nodes 20
DeepMesh RF
Range 70ft
Transmit Power +5dBm
Receive Sensitivity -95dBm
Protocol IEEE 802.15.4
Frequency Band 2405MHz – 2480MHz
Channels 11-26
I/O Digital input / outputs 2 dry contact inputs / UART pins
Power
Input Voltage 120Vac
Device Power Consumption 12VDC, 100mA
Max DC Power 200mA (100mA available to power
external device on 12Vdc)
Environment
Operating Temperature 0 -30C
Storage Temperature -10 – 50C
Humidity 10 – 90% RH, Non-condensing
Approvals
CFR47 FCC Part 15.247 Subpart C
CR47 FCC Part 15 Subpart B
RSS-247 Issue 2
ICES-003 Issue 6
RSS-Gen Issue 5
Rss-102 Issue 5
RJ-12 Low Voltage Connector
RJ-9 Switch Connector
Pin Typical Color* Function
1 White GND
2 Black +12V
3 Red S5 Bus
4 Green INPUT 1 / UART- Tx
5 Yellow INPUT 2 / UART - Rx
6 Blue NC
*Wire colors may differ
Conformance statement
FCC ID: GTC-201705X
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
IC: 1609A-201705X
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the
device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Wiring
CAUTION
Only a trained, experienced service technician should install the L510. Before beginning, the installer should
check the ratings given in the instructions and on the product to make sure the product is suitable for the
application.
The installer must disconnect the AC from the drape motor power supply before beginning the installation to
prevent electrical shock or equipment damage.
All wiring must comply with local codes and ordinances.
The L510 is intended for INDOOR USE ONLY.
It is important to read the instructions carefully. Failure to follow them could damage the product or cause a
hazardous condition.
Ordering Specifications
Model # Description
201-7050 L510 – Relay Lamp Controller
201-7051 L510 – Triac Lamp Controller
201-7052 L510 – FET Lamp Controller
Document Revision History
REVISION
DATE ISSUED REASON
V0.2 12 -Feb-2021 Added IC / FCC ID
!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Honeywell L510 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues