FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted
to the structure of the building.
2. Open the end link on the CHAIN (8) and attach to the loop on the FIXTURE ASSEMBLY (10). Hang the
FIXTURE ASSEMBLY (10) on the CHAIN (8) at your desired height, and remove excess CHAIN (8).
3. Feed the wire through the CHAIN (8) , SCREW COLLAR (9), CANOPY (7), SCREW COLLAR LOOP (6),
NIPPLE (5), and MOUNTING PLATE (1), and screw the NIPPLE (5) onto the MOUNTING PLATE (1).
4. Open the top link on the CHAIN(8), and Hang the FIXTURE ASSEMBLY(10) to the SCREW COLLAR LOOP(6).
5. Cut off excess wire, and strip the insulation off the end of the leads.
6. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bar copper wire) or
the GROUND SCREW (3) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT"
WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
7. Connect the fixture lead the ridge(s) to the neutral (Generally white) wire in the outlet box. Fasten the wires
together with an approved fastener (WIRE NUT) (4). Starting 1" below the fastener, tightly wrap the connection
with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO
EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
8. Connect the smooth fixture leads with to the hot (Generally black) wire in the junction box. Fasten the joined
wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS
COULD RESULT IN SERIOUS INJURY OR DEATH!
9. Screw the BULBS (11)(not included) up into the SOCKET of the fixture.THE FIXTURE IS RATED FOR 60
WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
10. Lift the GLASS (12) up onto the fixture and secure using the FINAL (13).
11. Restore power to the outlet at the breaker or fuse box.
PERCY
F1146
INSTALLATION INSTRUCTIONS
WARNING/CAUTION
·DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
·TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED
FACTORY TRAINED TECHNICIAN.
·CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS
AFTER USE.
·REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR
TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
·DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT
FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL
ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
·PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at [email protected]
ITEM DESCRIPTION PART NUMBER
1MOUNTING PLATE HDW-F1146
2MOUNTING SCREWS HDW-F1146
3GROUND SCREW HDW-F1146
4WIRE NUTS HDW-F1146
51/4 NIPPLE HDW-F1146
6SCREW COLLAR LOOP HDW-F1146
7 CANOPY CPY-F1146
8CHAIN CHN-F1146
9SCREW COLLAR HDW-F1146
10 FIXTURE ASSEMBLY FAS-F1146
11 BULBS NOT INCLUDED
12 GLASS GLS-F1146
13 FINAL FIN-F1146
1
2
3
4
5
6
7
8
9
10
11
12
13
ITEM DESCRIPTION PART NUMBER
1MOUNTING PLATE HDW-F1146
2MOUNTING SCREWS HDW-F1146
3GROUND SCREW HDW-F1146
4WIRE NUTS HDW-F1146
51/4 NIPPLE HDW-F1146
6SCREW COLLAR LOOP HDW-F1146
7 CANOPY CPY-F1146
8CHAIN CHN-F1146
9SCREW COLLAR HDW-F1146
10 FIXTURE ASSEMBLY FAS-F1146
11 BULBS NOT INCLUDED
12 GLASS GLS-F1146
13 FINAL FIN-F1146
FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted
to the structure of the building.
2. Open the end link on the CHAIN (8) and attach to the loop on the FIXTURE ASSEMBLY (10). Hang the
FIXTURE ASSEMBLY (10) on the CHAIN (8) at your desired height, and remove excess CHAIN (8).
3. Feed the wire through the CHAIN (8) , SCREW COLLAR (9), CANOPY (7), SCREW COLLAR LOOP (6),
NIPPLE (5), and MOUNTING PLATE (1), and screw the NIPPLE (5) onto the MOUNTING PLATE (1).
4. Open the top link on the CHAIN(8), and Hang the FIXTURE ASSEMBLY(10) to the SCREW COLLAR LOOP(6).
5. Cut off excess wire, and strip the insulation off the end of the leads.
6. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bar copper wire) or
the GROUND SCREW (3) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT"
WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
7. Connect the fixture lead the ridge(s) to the neutral (Generally white) wire in the outlet box. Fasten the wires
together with an approved fastener (WIRE NUT) (4). Starting 1" below the fastener, tightly wrap the connection
with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO
EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
8. Connect the smooth fixture leads with to the hot (Generally black) wire in the junction box. Fasten the joined
wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS
COULD RESULT IN SERIOUS INJURY OR DEATH!
9. Screw the BULBS (11)(not included) up into the SOCKET of the fixture.THE FIXTURE IS RATED FOR 60
WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
10. Lift the GLASS (12) up onto the fixture and secure using the FINAL (13).
11. Restore power to the outlet at the breaker or fuse box.
PERCY
F1146
INSTALLATION INSTRUCTIONS
www.hvlgroup.com
Questions? We're here to help!
Contact us at [email protected]
1
2
3
4
5
6
7
8
9
10
11
12
13
ATTENTION PRUDENCE
·DÉBRANCHEZ L'ALIMENTATION AVANT DE REMPLIR OU DE CÂBLER LE LUMINAIRE. LISEZ
COMPLÈTEMENT TOUTES LES INSTRUCTIONS AVANT DE COMMENCER L'INSTALLATION
·POUR ÉVITER LE RISQUE D'INCENDIE OU D'ÉLECTROCUTION, LE LUMINAIRE DOIT ÊTRE INSTALLÉ
CONFORMÉMENT À TOUS LES CODES ÉLECTRIQUES/DE CONSTRUCTION NATIONAUX ET LOCAUX
APPLICABLES. L'INSTALLATION ET L'ENTRETIEN DE CET APPAREIL DOIVENT ÊTRE EFFECTUÉS PAR UN
ÉLECTRICIEN AGRÉÉ OU UN TECHNICIEN CERTIFIÉ FORMÉ EN USINE.
·CALIFORNIE PROP 65 : CET APPAREIL D'ÉCLAIRAGE CONTIENT DES PRODUITS CHIMIQUES CONNUS PAR
L'ÉTAT DE CALIFORNIE POUR PROVOQUER LE CANCER, DES MALADIES CONGÉNITALES ET/OU D'AUTRES
DOMMAGES À LA REPRODUCTION. LAVER LES MAINS APRÈS UTILISATION.
·RETIRER LE LUMINAIRE, LES PIÈCES ET LE(S) SAC(S) DE PIÈCES DU CARTON. AVANT DE JETER LE
CARTON, VÉRIFIEZ DOUBLE POUR VOUS ASSURER QUE TOUTES LES PIÈCES SONT TROUVÉES.
INSPECTER LE LUMINAIRE AVANT L'INSTALLATION POUR TOUT DOMMAGE AU LUMINAIRE.
·GRADATION : LE LUMINAIRE PEUT ÊTRE CONTRLÉ PAR UN DISPOSITIF DE GRADATION MURALE. UTILISER
UNIQUEMENT UN GRADATEUR TRIAC/ÉLECTRONIQUE. ASSUREZ-VOUS QUE LE CARTON EST MARQUÉ
POUR UNE UTILISATION AVEC UNE SOURCE DE LUMIÈRE FLUORESCENTE À INCANDESCENTE COMPACTE
UNIQUEMENT. CEUX-CI PEUVENT ÊTRE FOURNIS PAR VOTRE DISTRIBUTEUR ÉLECTRIQUE LOCAL,
CENTRE À DOMICILE OU MAGASIN DE QUINCAILLERIE.
·VEUILLEZ NETTOYER UNIQUEMENT AVEC UN CHIFFON DOUX ET SEC ! N'UTILISEZ PAS DE NETTOYANTS
  • Page 1 1
  • Page 2 2

Troy Lighting F1146 11 Inch 3 Light Weathered Zinc Pendant Ceiling Light Manuel utilisateur

Taper
Manuel utilisateur