INSTALLATION INSTRUCTIONS
WARNING/CAUTION
·DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
·TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED
FACTORY TRAINED TECHNICIAN.
·CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH
HANDS AFTER USE.
·REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE
PRIOR TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
·DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT
FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL
ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
·PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at [email protected]
1
2
3
5
4
6
7
9
10
12
13
8
11
14
15
16
FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is designed to
be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of
the building.
2. Remove the SCREW COLLAR (3) from the COLLAR LOOP (4). Fully thread the NIPPLE (5) onto the COLLAR LOOP
(4). Thread the HEX NUTS (6) onto the NIPPLE (5) along with TOOTH WASHER (7). Then thread the NIPPLE (5) unto
the MOUNTING PLATE (1). Adjust the NIPPLE (5) so that the threads of the COLLAR LOOP (4) extends 1/4" beyond
the CANOPY (8). Secure using HEX NUT (6).
3. Open the end link the of the CHAIN (9) and attach to the FIXTURE ASSEMBLY (10) at the desired height. Slide the
SCREW COLLAR (3) and the CANOPY (8) onto the CHAIN (9). Attach the other end of the CHAIN (9) unto the COLLAR
LOOP (4). Feed the wires through the CHAIN (9) , SCREW COLLAR (3), CANOPY (8), COLLAR LOOP (4), NIPPLE (5),
and MOUNTING PLATE (1).
4. Cut off excess wires, and strip the insulation off the end of the leads.
5. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bare copper wire) or the
GROUND SCREW (11) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT" WIRE!
FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
6. Connect the fixture's SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the
outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (12). Starting 1" below the fastener, tightly
wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE
NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
7. Connect the fixture's SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box.
Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO
FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Push the wires back into the junction box. Lift up the CANOPY (8) up to the ceiling, and screw the SCREW COLLAR (3)
onto the COLLAR LOOP (4).
9. Screw the BULB (13) up into the SOCKET of the fixture.THIS FIXTURE IS RATED FOR 75 WATT TYPE A LAMP. DO
NOT EXCEED THE RECOMMENDED WATTAGE!
10. Untighten the THREADED COLLAR (15) from FITTER (16) allowing the glass over to make space for the GLASS (14).
Place the GLASS (14) beyond the glass holder. (NOTE: Please handle the GLASS (14) with care when putting to the
glass holder). Tighten back the THREADED COLLAR (15) to FITTER (16) just enough to hold the GLASS (14).
11. Restore power to the outlet at the breaker or fuse box.
ITEM DESCRIPTION PART NUMBER
1MOUNTING PLATE HDW-F1213
2MOUNTING SCREW HDW-F1213
3SCREW COLLAR HDW-F1213
4COLLAR LOOP CAS-F1213
5NIPPLE HDW-F1213
6HEX NUT HDW-F1213
7TOOTH WASHER HDW-F1213
8CANOPY CAS-F1213
9CHAIN CHN-F1213
10 FIXTURE ASSEMBLY FAS-F1218
11 GROUND SCREW HDW-F1213
12 WIRE NUT HDW-F1213
13 BULB NOT INCLUDED
14 GLASS GLS-F1218
15 THREADED COLLAR HRD-F1213
16 FITTER FIT-F1218
ENZO
F1218
INSTALLATION INSTRUCTIONS
www.hvlgroup.com
Questions? We're here to help!
Contact us at [email protected]
1
2
3
5
4
6
7
9
10
12
13
8
11
14
15
16
FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is designed to
be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of
the building.
2. Remove the SCREW COLLAR (3) from the COLLAR LOOP (4). Fully thread the NIPPLE (5) onto the COLLAR LOOP
(4). Thread the HEX NUTS (6) onto the NIPPLE (5) along with TOOTH WASHER (7). Then thread the NIPPLE (5) unto
the MOUNTING PLATE (1). Adjust the NIPPLE (5) so that the threads of the COLLAR LOOP (4) extends 1/4" beyond
the CANOPY (8). Secure using HEX NUT (6).
3. Open the end link the of the CHAIN (9) and attach to the FIXTURE ASSEMBLY (10) at the desired height. Slide the
SCREW COLLAR (3) and the CANOPY (8) onto the CHAIN (9). Attach the other end of the CHAIN (9) unto the COLLAR
LOOP (4). Feed the wires through the CHAIN (9) , SCREW COLLAR (3), CANOPY (8), COLLAR LOOP (4), NIPPLE (5),
and MOUNTING PLATE (1).
4. Cut off excess wires, and strip the insulation off the end of the leads.
5. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bare copper wire) or the
GROUND SCREW (11) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT" WIRE!
FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
6. Connect the fixture's SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the
outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (12). Starting 1" below the fastener, tightly
wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE
NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
7. Connect the fixture's SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box.
Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO
FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Push the wires back into the junction box. Lift up the CANOPY (8) up to the ceiling, and screw the SCREW COLLAR (3)
onto the COLLAR LOOP (4).
9. Screw the BULB (13) up into the SOCKET of the fixture.THIS FIXTURE IS RATED FOR 75 WATT TYPE A LAMP. DO
NOT EXCEED THE RECOMMENDED WATTAGE!
10. Untighten the THREADED COLLAR (15) from FITTER (16) allowing the glass over to make space for the GLASS (14).
Place the GLASS (14) beyond the glass holder. (NOTE: Please handle the GLASS (14) with care when putting to the
glass holder). Tighten back the THREADED COLLAR (15) to FITTER (16) just enough to hold the GLASS (14).
11. Restore power to the outlet at the breaker or fuse box.
ITEM DESCRIPTION PART NUMBER
1MOUNTING PLATE HDW-F1213
2MOUNTING SCREW HDW-F1213
3SCREW COLLAR HDW-F1213
4COLLAR LOOP CAS-F1213
5NIPPLE HDW-F1213
6HEX NUT HDW-F1213
7TOOTH WASHER HDW-F1213
8CANOPY CAS-F1213
9CHAIN CHN-F1213
10 FIXTURE ASSEMBLY FAS-F1218
11 GROUND SCREW HDW-F1213
12 WIRE NUT HDW-F1213
13 BULB NOT INCLUDED
14 GLASS GLS-F1218
15 THREADED COLLAR HRD-F1213
16 FITTER FIT-F1218
ATTENTION PRUDENCE
·DÉBRANCHEZ L'ALIMENTATION AVANT DE REMPLIR OU DE CÂBLER LE LUMINAIRE. LISEZ
COMPLÈTEMENT TOUTES LES INSTRUCTIONS AVANT DE COMMENCER L'INSTALLATION
·POUR ÉVITER LE RISQUE D'INCENDIE OU D'ÉLECTROCUTION, LE LUMINAIRE DOIT ÊTRE INSTALLÉ
CONFORMÉMENT À TOUS LES CODES ÉLECTRIQUES/DE CONSTRUCTION NATIONAUX ET LOCAUX
APPLICABLES. L'INSTALLATION ET L'ENTRETIEN DE CET APPAREIL DOIVENT ÊTRE EFFECTUÉS PAR UN
ÉLECTRICIEN AGRÉÉ OU UN TECHNICIEN CERTIFIÉ FORMÉ EN USINE.
·CALIFORNIE PROP 65 : CET APPAREIL D'ÉCLAIRAGE CONTIENT DES PRODUITS CHIMIQUES CONNUS PAR
L'ÉTAT DE CALIFORNIE POUR PROVOQUER LE CANCER, DES MALADIES CONGÉNITALES ET/OU D'AUTRES
DOMMAGES À LA REPRODUCTION. LAVER LES MAINS APRÈS UTILISATION.
·RETIRER LE LUMINAIRE, LES PIÈCES ET LE(S) SAC(S) DE PIÈCES DU CARTON. AVANT DE JETER LE
CARTON, VÉRIFIEZ DOUBLE POUR VOUS ASSURER QUE TOUTES LES PIÈCES SONT TROUVÉES.
INSPECTER LE LUMINAIRE AVANT L'INSTALLATION POUR TOUT DOMMAGE AU LUMINAIRE.
·GRADATION : LE LUMINAIRE PEUT ÊTRE CONTRLÉ PAR UN DISPOSITIF DE GRADATION MURALE. UTILISER
UNIQUEMENT UN GRADATEUR TRIAC/ÉLECTRONIQUE. ASSUREZ-VOUS QUE LE CARTON EST MARQUÉ
POUR UNE UTILISATION AVEC UNE SOURCE DE LUMIÈRE FLUORESCENTE À INCANDESCENTE COMPACTE
UNIQUEMENT. CEUX-CI PEUVENT ÊTRE FOURNIS PAR VOTRE DISTRIBUTEUR ÉLECTRIQUE LOCAL,
CENTRE À DOMICILE OU MAGASIN DE QUINCAILLERIE.
·VEUILLEZ NETTOYER UNIQUEMENT AVEC UN CHIFFON DOUX ET SEC ! N'UTILISEZ PAS DE NETTOYANTS
  • Page 1 1
  • Page 2 2

Troy Lighting F1218 1 Light 10 inch Gesso White Pendant Ceiling Light Manuel utilisateur

Taper
Manuel utilisateur