Hunter Fan 37282 Le manuel du propriétaire

Catégorie
Humidificateurs
Taper
Le manuel du propriétaire

Ce manuel convient également à

www.hunterfan.com
The Care Free
®
Humidifier Plus
Evaporative Humidifier
41554-01 06/09/2004 1 © 2004 HUNTER FAN CO.
Features (Vary By Model):
NiteGlo™ Night Light
Adjustable Humidistat
Automatic Shut-Off
41554-01 06/09/2004 2 © 2004 HUNTER FAN CO.
READ AND SAVE THESE INSTRUCTIONS
The Care Free
®
Humidifier Plus Evaporative
Humidifier has a unique patented design with
several innovative features:
Low Maintenance Other humidifiers have
paper filters that need to be replaced every
few months. Our exclusive PermaWick™ fil-
ter saves time and money. It’s designed to
last season after season, saving up to $45 a
year. No wet paper odors either.
Regulated Release™ System – By dis-
persing water from the top of the
PermaWick™ filter, stagnant water around
the PermaWick™ filter is eliminated, and
the buildup of mineral residue that can
clog the filter and impede performance
is eliminated. NOTE: The filter has a coat-
How The Care Free
®
Humidifier Plus
Evaporative Humidifier Works
ing on the wick which may make it appear
old or used, but is actually new.
Built-in Antimicrobial Properties – The
plastic parts and the PermaWick™ filter
have built-in antimicrobial properties to in-
hibit the growth of bacteria, mold and
fungi that may affect these parts.
NOTE: This product contains antimicrobial
properties which are built-in to inhibit the
growth of bacteria which may affect the
plastic and PermaWick™ filter in the hu-
midifier. These properties do not extend to
the water, humidified air or users. Conduct
routine cleaning and maintenance based
upon use and individual conditions.
Important Safety Instructions:
Read all instructions before
using this humidifier.
1. This humidifier may not work properly
on an uneven surface. ALWAYS place
this humidifier on a firm, level, and wa-
ter resistant surface. ALWAYS place the
humidifier at least six (6) inches away from
walls and heat sources such as stoves,
radiators, or heaters.
2. ALWAYS place the humidifier in an area
that is out of the reach of children.
3. Before using the humidifier, extend the
cord and inspect for any signs of dam-
age. DO NOT use the product if the cord
has been damaged.
4. This product has a polarized plug (one
blade is wider than the other) as a safety
feature. This plug will fit into a polarized
outlet only one way. If the plug does not
fit fully into the outlet, reverse the plug.
If it still does not fit, contact a qualified
electrician. DO NOT attempt to defeat
or override this safety feature.
5. ALWAYS UNPLUG AND EMPTY the hu-
midifier when it is not in operation or
while it is being cleaned.
6. DO NOT tilt or move the humidifier while
it is in operation. Never move the hu-
midifier while there is water in the tank.
Empty the water tank, turn off, and un-
plug the unit before moving.
7. In addition to routine maintenance which
may be required, this humidifier requires
seasonal cleaning. Refer to and follow
CLEANING THE HUMIDIFIER AND THE
WATER TANK instructions.
Thank you for purchasing The Care Free
®
Humidifier Plus Evaporative Humidifier by
Hunter Fan Company. Please read and
save these instructions to receive the maxi-
mum benefit and performance from your
humidifier.
41554-01 06/09/2004 3 © 2004 HUNTER FAN CO.
No White Dust – The Care Free
®
Humidi-
fier Plus Evaporative Humidifier produces
no white dust that can settle on furniture
or be inhaled.
NOTE: You may notice mineral deposits
accumulating in the tank base or on the
PermaWick™ filter. This is normal and
does not affect performance. If you
would like to clean these deposits away,
please see CLEANING THE HUMIDIFIER
AND WATER TANK.
Humidifier Parts
Figure 1
Water Tank
Tank Cap
Easy Tote Handle
Main Housing
Base
PermaWick™ Filter
Knob A
Knob B
Filter Frame
Hooks
Push
Lift Up
PermaWick™
Filter Frame
Insert Guides
Into Base
41554-01 06/09/2004 4 © 2004 HUNTER FAN CO.
Humidifier Features
For Models 33200A & 37200
Speed
Control
Power
Control
Power
Light
Figure 2
Fan Power: Turns the humidifier ‘ON’ and
‘OFF’. The power should always be off before
unplugging the humidifier, moving the
humidifier, or refilling the water tank.
Speed Control: Enables you to choose ‘HI’ or
‘LO’ speed.
Power Light: The light will be illuminated
when the power is on.
For Models 33232, 33251, 37232 & 37251
Fan Power: Turns the humidifier ‘ON’ and
‘OFF’. The power should always be off before
unplugging the humidifier, moving the
humidifier, or refilling the water tank.
Speed Control: Enables you to choose ‘HI’ or
‘LO’ speed.
Power Light: The light will be illuminated
when the power is on.
NiteGlo™ Night Light Control: Turns the
night light ‘ON’ and ‘OFF’. The night light can
be turned on even if the humidifier fan is turned
off.
Speed
Control
Power
Control
Power
Light
Figure 3
NiteGlo™
Night
Light
Control
41554-01 06/09/2004 5 © 2004 HUNTER FAN CO.
Adjustable
Humidistat
Power/
Speed
Control
Power
Light
Desired
Humidity
Light
For Models 33203, 33252, 33282,
34332, 37203, 37252 & 37282
Adjustable Humidistat: Enables you to set a
desired maximum humidity level. Once this
level is reached, the unit will shut off until the
humidity level drops.
Note: The humidifier may not be running
because the humidistat setting may need to
be adjusted.
Desired Humidity Light: The green light will
be illuminated when the humidity in the room
has reached the level that you selected with
the adjustable humidistat knob.
Power/Speed Control: Turns the humidifier
‘ON’ and ‘OFF’. The power should always be
off before unplugging the humidifier, moving
the humidifier, or refilling the water tank.
Power Light: The light will be illuminated
when the power is on.
NiteGlo Night Light Control: Turns the
night light ‘ON’ and ‘OFF’. The night light can
be turned on even if the humidifier fan is turned
off.
Figure 5
NiteGlo
Night
Light
Control
Adjustable
Humidistat
Power/
Speed
Control
Power
Light
Desired
Humidity
Light
For Models 33250A, 33280A, 34331 & 37250
Adjustable Humidistat: Enables you to set a
desired maximum humidity level. Once this
level is reached, the unit will shut off until the
humidity level drops.
Note: The humidifier may not be running
because the humidistat setting may need to be
adjusted.
Desired Humidity Light: The green light will
be illuminated when the humidity in the room
has reached the level that you selected with
the adjustable humidistat knob.
Power/Speed Control: Turns the humidifier
‘ON’ and ‘OFF’. The power should always be
off before unplugging the humidifier, moving the
humidifier, or refilling the water tank.
Power Light: The light will be illuminated when
the power is on.
Figure 4
41554-01 06/09/2004 6 © 2004 HUNTER FAN CO.
Adjustable
Humidistat
Power/
Speed
Control
Refill
Light
Desired
Humidity
Light
For Models 34302, 34352, 37302 & 37352
Adjustable Humidistat: Enables you to set a
desired maximum humidity level. Once this
level is reached, the unit will shut off until the
humidity level drops.
Note: The humidifier may not be running
because the humidistat setting may need to
be adjusted.
Desired Humidity Light: The green light will
be illuminated when the humidity in the room
has reached the level that you selected with
the adjustable humidistat knob.
Power/Speed Control: Turns the humidifier
‘ON’ and ‘OFF’. The power should always be
off before unplugging the humidifier, moving
the humidifier, or refilling the water tank.
Refill Light: The red light will be illuminated
to signal you that the humidifier has
automatically turned off and the water tank
needs to be refilled.
NiteGlo™ Night Light Control: Turns the
night light ‘ON’ and ‘OFF’. The night light can
be turned on even if the humidifier fan is turned
off.
Figure 7
NiteGlo™
Night
Light
Control
Adjustable
Humidistat
Power/
Speed
Control
Refill
Light
Desired
Humidity
Light
For Models 34301, 34351, 37300 & 37350
Adjustable Humidistat: Enables you to set a
desired maximum humidity level. Once this
level is reached, the unit will shut off until the
humidity level drops.
Note: The humidifier may not be running
because the humidistat setting may need to be
adjusted.
Desired Humidity Light: The green light will
be illuminated when the humidity in the room
has reached the level that you selected with
the adjustable humidistat knob.
Power/Speed Control: Turns the humidifier
‘ON’ and ‘OFF’. The power should always be
off before unplugging the humidifier, moving the
humidifier, or refilling the water tank.
Refill Light: The red light will be illuminated to
signal you that the humidifier has automatically
turned off and the water tank needs to be
refilled.
Figure 6
41554-01 06/09/2004 7 © 2004 HUNTER FAN CO.
1. Remove The Care Free
®
Humidifier Plus
Evaporative Humidifier from its packaging.
Read and Save the Instructions.
2. Place the humidifier on a hard, flat, water
resistant surface. Always place the humidi-
fier at least six (6) inches away from walls and
sources of heat.
3. Lift the main housing to confirm that the
PermaWick™ filters are placed upright in the
slots. Replace the main housing. (See Figure 1.)
4. Remove the water tank and take it to the
sink or tub to fill.
5. Turn the tank upside down and unscrew the
tank cap by turning it counterclockwise. Fill
the water tank with cool water and replace
the tank cap (Never use hot water). Be sure
not to overfill the tank as water damage may
occur to furniture or flooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY FOR
DAMAGE TO PROPERTY CAUSED BY WATER
SPILLAGE.
6. Carry the tank back to the humidifier. Turn
the tank upright and place it on the humidi-
fier. Be sure that the tank is seated properly
in the base. If the tank is properly located on
the base, you will see air bubbles flowing up
into the tank.
7. With the power control knob in the ‘OFF’ po-
sition, plug the humidifier into the wall.
CAUTION: Never plug in the Humidifier
while your hands are wet as Electric Shock
could occur.
8. Use the power control knob to turn the
humidifier ‘ON’ by selecting a speed set-
ting.
Using Your Humidifier
Only for models with an Adjustable Humi-
distat
9. You can choose the desired humidity out-
put by adjusting the Adjustable Humidis-
tat knob. In a very dry room, the “HI”
setting should be used to quickly achieve
a comfortable level of humidity. Once the
room is comfortable, you can turn the
Adjustable Humidistat down. Selection
of your desired humidity level is a per-
sonal choice and you may have to adjust
the dial to find the level where you feel
most comfortable. To begin with, we sug-
gest you try a middle location between
the lowest and the maximum setting.
Then, adjust the level to suit your needs.
10. When the humidity reaches the level you
have set, the “Desired Humidity” light will
be illuminated. The humidifier will not
output humidity while the humidity in the
room is at the selected humidity level. The
“Desired Humidity” light will stay on un-
til the humidity changes. When the hu-
midity in the room drops below the se-
lected level, the humidifier will cycle on
again and the “Desired Humidity” light
will go off.
Only for models with Automatic Shut-off
11. When the water tank is empty, the humidi-
fier will automatically shut itself off. The
red light will be illuminated, indicating that
the water tank needs to be refilled.
12. Follow REFILLING THE WATER TANK di-
rections. Once the water tank is refilled,
the Refill Light will not be illuminated.
Only for models with a NiteGlo™ Night Light
13. Use the control to turn the night light off
and on. The night light can be operated
even if the humidifier fan is turned ‘OFF’.
41554-01 06/09/2004 8 © 2004 HUNTER FAN CO.
Cleaning The Humidifier And The Water Tank
Refilling The Water Tank
1. When the water tank level is low, turn the
humidifier ‘OFF’, and unplug.
2. Remove the tank and take it to the sink or
tub to refill.
3. Turn the tank upside down and unscrew the
tank cap by turning it counterclockwise.
Empty the tank, refill with fresh cool water
(never use hot water), and replace the tank
cap. Be sure not to overfill the tank as water
damage may occur to furniture or flooring
due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBIL-
ITY FOR DAMAGE TO PROPERTY CAUSED
BY WATER SPILLAGE.
4. Carry the tank back to the humidifier. Turn
the tank upright and place it on the hu-
midifier. Be sure that the tank is seated
properly in the base. If the tank is properly
located on the base, you will see air bubbles
flowing up into the tank.
Many regions have hard water with high
concentrations of minerals. When water
evaporates from The Care Free
®
Humidifier Plus
Evaporative Humidifier, minerals may be left
behind. These minerals can form a hard white
scale which can be removed by following the
cleaning instructions. The frequency of
cleaning due to mineral build up can vary
depending upon the quality of water you
may have.
Refer to Figure 1 for part names.
1. Turn the humidifier ‘OFF’ and unplug the
unit.
2. Lift the main housing and remove the wa-
ter dispersion tray and the PermaWick™
Filters. The motor is attached to the main
housing. Do not place the motor near
water. Do not use a wet towel on the
motor or motor housing as electrical
shock may occur.
3. The PermaWick™ Filter should be cleaned
in a vinegar and water solution to remove
any mineral buildup. Place in a solution of
one (1) gallon of water and eight (8) ounces
of undiluted white vinegar. Allow the filter
to soak for 20 minutes.
4. After soaking, rinse it several times with
clean water. Place the PermaWick™ Filter
in a location where it can drip dry while
you clean the other parts of your humidifier.
5. Remove the water tank from the base and
empty any water that is left in the tank.
Soak the base in a mixture of one (1) gal-
lon of water and eight (8) ounces of vin-
egar for 20 minutes.
6. After soaking, wipe the base with a soft
cloth or sponge to remove any mineral
build up. Rinse with clean water several
times. If you are planning on storing the
humidifier, be sure the base is com-
pletely dry.
7. Fill the water tank with one (1) gallon of
water and eight ounces of undiluted white
vinegar. Replace the tank cap and shake
the tank vigorously until all interior sur-
faces of the tank have been exposed to the
water/vinegar mixture.
8. Empty the tank of the water/vinegar mix-
ture. Rinse it several times with clean water
and then replace the tank cap. If you are
planning on storing the humidifier, dry it
inside and out, leaving the cap off to allow
the tank to completely dry. Continue to
clean the other parts of your humidifier.
9. Remove the water diffuser cap and sponge.
Rinse the sponge in clean water to remove
any debris. If the sponge contains hard
41554-01 06/09/2004 9 © 2004 HUNTER FAN CO.
To obtain a service part for your humidifier, call customer service at 1-888-830-1326 or e-mail us
at T[email protected]. Please be prepared to tell the operator the model number of
your humidifier and the name of the part you need to replace and the part number. Refer to
Figure 1 for part names.
Service Parts
water residue, soak it in a mixture of
one (1) gallon of water and eight (8)
ounces of vinegar for 20 minutes. Rinse
well and reinstall sponge and diffuser cap
in unit. Do not expose motor or other
electrical components to water.
10. Wipe the surfaces of the main housing with
a soft cloth.
11. Once all the parts are clean, reas-
semble the humidifier, and follow the
USING YOUR HUMIDIFIER
to con-
tinue use. If you are storing the hu-
midifier, make sure the parts are
completely dry, reassemble, and
store in a dry location.
Model No.
Filter
Frame
Base
Water
Tank
Knob
A
Knob
B
Tank
Ca
p
Perma wick
Filter
33200A
33203 64101-01-325
33232
33250A
33252
33280A
33282
34301
34302
34331
34332
34351
34352
37200
37203 64102-01-325
37232
37250
37252
37300
37302
37350
37352
74079-01-325
74080
74082
74080
74082
64101-01-325
64102-01-325
92851-01-326
92850-01-325
92849-01-325
92850-01-325
64171-01-000
64171-01-000
64102-01-325
92852-01-326
92851-01-326
92852-01-326
64171-03-000
67171-01-001
64171-01-001
64171-03-000
33251
64171-01-001
64171-01-000
64102-01-325
37251
64171-01-000
67171-01-001
92849-01-325
64102-01-325
41554-01 06/09/2004 10 © 2004 HUNTER FAN CO.
The Hunter Fan Company, Inc. makes the
following warranty to the original residen-
tial user or consumer purchaser of The Care
Free
®
Humidifier Plus Evaporative Humidi-
fier:
If any part of The Care Free
®
Humidifier Plus
Evaporative Humidifier (“Humidifier”) mo-
tor fails during the first 5 (five) years from the
date of installation due to a defect in mate-
rial or workmanship, we will provide a re-
placement part free of charge. If no replace-
ment part can be provided for such motor, we
will replace your humidifier.
If your Humidifier motor fails any time
within 1 (one) year after the date of instal-
lation due to a defect in material or work-
manship, labor to repair the defect will be
provided free of charge at our nearest ser-
vice centre or at our Service Department in
Memphis, Tennessee. You will be respon-
sible for all parts and labor costs after this
one-year period.
If your Humidifier water tank, filter fame, base,
knobs, or tank cap fail any time within 1 (one)
year after the date of sale to you due to a
defect in material or workmanship, we will
repair or, at our option, replace the water tank,
filter frame, base, knobs, or tank cap free of
charge for parts or labor performed at our near-
est service centre or our Service Department
in Memphis, Tennessee.
IF THE ORIGINAL RESIDENTIAL USER OR
CONSUMER PURCHASER CEASES TO
OWN THE HUMIDIFIER, THIS WARRANTY
AND ANY IMPLIED WARRANTY WHICH
THEN REMAINS IN EFFECT, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE,
ARE VOIDED.
Hunter Fan Company
The Care Free
®
Humidifier Plus Evaporative Humidifier
5 YEAR LIMITED WARRANTY
NO WARRANTY, EXPRESSED OR IM-
PLIED, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, IS MADE IN RE-
SPECT TO THE FILTER.
THIS WARRANTY IS IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. THE DU-
RATION OF ANY IMPLIED WARRANTY,
INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, IN RESPECT TO THE MOTOR
IS EXPRESSLY LIMITED TO THE PERIOD
OF THE EXPRESS WARRANTY SET
FORTH ABOVE.
This warranty is voided if your Humidi-
fier is not purchased and used in the USA
or Canada.
This warranty excludes and does not cover
defects, malfunctions, or failures of the Hu-
midifier which were caused by repairs by per-
sons not authorized by us, use of parts, or
accessories not authorized by us, mishan-
dling, modifications, or damage to the Hu-
midifier while in your possession, or unrea-
sonable use, including failure to provide rea-
sonable and necessary maintenance. This
warranty does not cover humidifiers used in
commercial applications. There are no express
or implied warranties as to commercial pur-
chasers or users.
To obtain service, contact the nearest Hunter
authorized service centre or the Hunter Fan
Company Service Department, 2500 Frisco
Avenue, Memphis, Tennessee 38114, 901-
248-2222. You will be responsible for insur-
ance and freight or other transportation to
our factory service center. We will return the
Humidifier freight prepaid to you. The Hu-
midifier should be properly packaged to
41554-01 06/09/2004 11 © 2004 HUNTER FAN CO.
HUNTER FAN COMPANY
2500 FRISCO AVENUE
MEMPHIS, TN 38114, USA
avoid damage in transit since we will not be
responsible for any such damage. Proof of
purchase is required when requesting war-
ranty service. The purchaser must present the
sales receipt or other document that estab-
lishes proof of purchase.
IN NO EVENT SHALL HUNTER FAN COM-
PANY BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, CONSEQUENTIAL OR INCIDEN-
TAL DAMAGES IN EXCESS OF THE PUR-
CHASE PRICE OF THE HUMIDIFIER. YOUR
SOLE REMEDY WILL BE REPAIR OR RE-
PLACEMENT AS PROVIDED ABOVE.
SOME AMERICAN STATES AND CANA-
DIAN PROVINCES DO NOT ALLOW
LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS;
THE EXCLUSION OR LIMITATION
OF DIRECT, INDIRECT, SPECIAL, IN-
CIDENTAL OR CONSEQUENTIAL
DAMAGES;
THE EXCLUSION OR INVALIDITY
OF EXPRESS OR IMPLIED WARRAN-
TIES IF THE USER CEASES TO OWN
THE HUMIDIFIER;
THE LIMITATION OF THE REM-
EDIES AND RECOURSES AVAIL-
ABLE TO THE PURCHASER; OR
THE INVALIDITY OF AN EXPRESS
WARRANTY WHEN A PRODUCT
IDENTIFIED BY BRAND NAME IS
NOT USED (UNLESS SPECIFIC CON-
DITIONS ARE FULFILLED);
SO THE ABOVE LIMITATIONS OR EXCLU-
SIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE OR PROVINCE TO PROV-
INCE.
41554-01 06/09/2004 12 © 2004 HUNTER FAN CO.
To learn more about Hunter Fan Company products, please see our web page at:
www.hunterfan.com
Other Home Comfort Products from Hunter
Hunter Original
®
QuietFlo™
True HEPA Air
Purifier
Programmable
Thermostat
TM
F
i
lt
er
Pr
e-
F
il
te
r
Fi
lt
er
R
es
e
t
www.hunterfan.com
The Care Free
®
Humidifier Plus
Humidificateur à
Évaporation
41554-05 06/09/2004 13 © 2004 HUNTER FAN CO.
Caractéristiques (Changez par le modèle):
Veilleuse NiteGlo™
Humidostat réglable
Avec arrêt automatique
41554-05 06/09/2004 14 © 2004 HUNTER FAN CO.
LISEZ ET CONSERVEZ CES INSTRUCTIONS
L’humidificateur à évaporation The Care Free
®
Humidifier Plus a une conception brevetée toute
particulière et plusieurs caractéristiques
innovatrices :
Système Regulated Release™ – En dis-
tribuant l’eau par le haut du filtre
PermaWick™, ce système élimine l’eau sta-
gnante autour du filtre PermaWick™,
évitant l’accumulation de minéraux qui
peuvent boucher le filtre et diminuer la per-
formance de l’humidificateur. ATTENTION
: Le filtre possède un enduit qui peut le
faire paraître usagé ou ancien mais en fait
il est neuf.
Comment l’humidificateur à évaporation The Care
Free
®
Humidifier Plus fonctionne
Propriétés antimicrobiennes incorpo-
rées – les pièces en plastique et le filtre
PermaWick™ possèdent des propriétés
antimicrobiennes incorporées pour éviter
la croissance des bactéries, moisissures et
champignons qui pourraient s’y trouver.
ATTENTION : Ce produit contient des
propriétés antimicrobiennes qui ont été in-
corporées pour éviter la croissance de
bactéries qui peuvent se trouver sur le plas-
tique et le filtre PermaWick dans
l’humidificateur. Ces propriétés ne s’éten-
dent pas à l’eau, à l’air humidifié ou aux
utilisateurs. Il faut le nettoyer régulièrement
et faire l’entretien selon l’usage et les con-
ditions individuelles.
Instructions de sécurité
importantes : Lisez toutes les
instructions avant d'employer
cet humidificateur.
1. Cet humidificateur peut ne pas
fonctionner correctement sur une surface
irrégulière. Il faut TOUJOURS placer cet
humidificateur sur une surface ferme,
horizontale et résistant à l’eau. Il faut
TOUJOURS placer cet humidificateur à
une distance d’au moins 15 cm (6
pouces) des murs et des sources de
chaleur comme les radiateurs et les
appareils de chauffage.
2. Il faut TOUJOURS placer l’humidificateur
dans un endroit inaccessible aux enfants.
3. Avant d’employer l’humidificateur,
déroulez le cordon d’alimentation et
vérifiez qu’il n’est pas endommagé. Il ne
faut JAMAIS employer ce produit si le
cordon électrique est endommagé.
4. Pour une plus grande sécurité, ce produit
est muni d’une fiche polarisée (une
broche est plus large que l’autre). Cette
fiche ne se place dans une prise polarisée
que d’une seule manière. Si la fiche ne
rendre pas dans la prise, retournez-la. Si
elle ne rentre toujours pas, contactez un
électricien de métier. IL NE FAUT PAS
essayer de contourner cette sécurité ou
de la rendre inopérante.
5. Il faut TOUJOURS DÉBRANCHER ET
VIDER l’humidificateur quand il n’est pas
employé ou quand vous le nettoyez.
6. IL NE FAUT PAS incliner ou déplacer
l’humidificateur quand il fonctionne. Il
ne faut jamais déplacer l’humidificateur
quand il y a de l’eau dans le réservoir.
Videz le réservoir, arrêtez l’humidificateur
et débranchez-le avant de le déplacer.
7. En plus d’un entretien régulier, il faut
nettoyer cet humidificateur à la fin de la
saison. Référez-vous aux instructions de
NETTOYAGE DE L’HUMIDIFICATEUR
ET DU RÉSERVOIR D’EAU.
Merci d’avoir acheté l’humidificateur à
évaporation The Care Free
®
Humidifier Plus
de la compagnie Hunter Fan. Veuillez lire
et gardez ces instructions pour obtenir la
meilleure performance et des bénéfices
maximums de votre humidificateur.
41554-05 06/09/2004 15 © 2004 HUNTER FAN CO.
Pièces de l'humidificateur
Figure 1
Filtre PermaWick™
Carter
principal
Pas de poussière blanche – l’humidificateur
The Care Free
®
Humidifier Plus ne produit pas
de poussière blanche qui peut se déposer sur
les meubles ou risque d’être inhalée.
ATTENTION : Vous pouvez remarquer des
dépôts minéraux accumulés dans la base
du réservoir ou sur le filtre PermaWick™.
Ceci est normal et ne modifie pas la perfor-
mance. Si vous voulez nettoyer ces dépôts
référez-vous aux instructions de NET-
TOYAGE DE L’HUMIDIFICATEUR ET DU
RÉSERVOIR D’EAU.
Base
Bouton A
Bouton B
Crochets du
cadre de filtre
Pousser
Soulever
Cadre du Filtre
PermaWick™
Insérez les guides
dans la base
Poignée facile
Réservoir
d'eau
Bouchon du
réservoir
41554-05 06/09/2004 16 © 2004 HUNTER FAN CO.
Pour Modèles 33200A et 37200
Commande
de vitesse
Commande
de mise en
marche
Voyant de
fonction-
nement
Figure 2
Commande de mise en marche: Met en
marche et arrête l’humidificateur. Il faut
toujours arrêter l’humidificateur avant de le
débrancher, de la déplacer ou de remplir le
réservoir d’eau.
Commande de vitesse: vous permet de choisir
entre les vitesse basse (LO) et haute (HI).
Voyant de fonctionnement: Le voyant rouge
sera allumé quand l’humidificateur est en
marche.
Caractéristiques de l’humidificateur
Pour Modèles 33232, 33251, 37232 et 37251
Commande
de vitesse
Commande
de mise en
marche
Voyant de
fonction-
nement
Figure 3
Commande de mise en marche: Met en
marche et arrête l’humidificateur. Il faut
toujours arrêter l’humidificateur avant de le
débrancher, de la déplacer ou de remplir le
réservoir d’eau.
Commande de vitesse: vous permet de choisir
entre les vitesse basse (LO) et haute (HI).
Voyant de fonctionnement: Le voyant rouge
sera allumé quand l’humidificateur est en
marche.
Commande de veilleuse NiteGlo™: Allume
et éteint la veilleuse. La veilleuse peut être
allumée même quand l'humidificateur est
arrêté.
Commande
de veilleuse
NiteGlo™
41554-05 06/09/2004 17 © 2004 HUNTER FAN CO.
Pour Modèles 33203, 33252, 33282,
34332, 37203, 37252 et 37282
Humidostat réglable: vous permet de régler
la quantité d’humidité à diffuser. Une fois que
le bon niveau est atteint, l’appareil reste arrêté
jusquau moment où le niveau dhumidité
tombe.
Note: Si l’humidificateur ne fonctionne pas, il
peut être nécessaire de régler l’humidostat.
Voyant d’humidité désirée: Le voyant vert sera
alluquand l’humidité dans la pièce a atteint
le niveau que vous avez choisi sur le bouton de
l’humidostat.
Commande de mise en marche/vitesse: Met
en marche et arte lhumidificateur. Il faut
toujours arter l’humidificateur avant de le
brancher, de la déplacer ou de remplir le
réservoir d’eau.
Voyant de fonctionnement: Le voyant rouge
sera allu quand lhumidificateur est en
marche.
Commande de veilleuse NiteGlo™: Allume
et éteint la veilleuse. La veilleuse peut être
allumée même quand l'humidificateur est
arrêté.
Figure 5
Commande
de veilleuse
NiteGlo™
Humidostat
réglable
Commande
de mise en
marche/
vitesse
Voyant
d’humidité
désirée
Voyant de
fonction-
nement
Humidostat
réglable
Commande
de mise en
marche/
vitesse
Voyant
d’humidi
désirée
Pour Modèles 33250A, 33280A, 34331 et 37250
Humidostat réglable: vous permet de régler
la quantité d’humidité à diffuser. Une fois que
le bon niveau est atteint, l’appareil reste arrêté
jusqu’au moment le niveau d’humidité tombe.
Note: Si l’humidificateur ne fonctionne pas, il
peut être nécessaire de régler l’humidostat.
Voyant d’humidi sirée: Le voyant vert
sera alluquand l’humididans la pièce a
atteint le niveau que vous avez choisi sur le
bouton de l’humidostat.
Commande de mise en marche/vitesse: Met
en marche et arte lhumidificateur. Il faut
toujours arter l’humidificateur avant de le
brancher, de la déplacer ou de remplir le
réservoir d’eau.
Voyant de fonctionnement: Le voyant rouge
sera allu quand lhumidificateur est en
marche.
Figure 4
Voyant de
fonction-
nement
41554-05 06/09/2004 18 © 2004 HUNTER FAN CO.
Pour Modèles 34302, 34352, 37302 et 37352
Humidostat réglable: vous permet de régler
la quantité d’humidité à diffuser. Une fois que
le bon niveau est atteint, l’appareil reste arrêté
jusqu’au moment où le niveau d’humidité
tombe.
Note: Si l’humidificateur ne fonctionne pas, il
peut être nécessaire de régler l’humidostat.
Voyant d’humidité désirée: Le voyant vert sera
allumé quand l’humidité dans la pièce a atteint
le niveau que vous avez choisi sur le bouton de
l’humidostat.
Commande de mise en marche/vitesse: Met
en marche et arrête l’humidificateur. Il faut
toujours arrêter l’humidificateur avant de le
débrancher, de la déplacer ou de remplir le
réservoir d’eau.
Voyant de remplissage: Le voyant rouge
s’allume pour vous signaler que
l’humidificateur s’est arrêté automatiquement
et que le réservoir d’eau doit être rempli.
Commande de veilleuse NiteGlo™: Allume
et éteint la veilleuse. La veilleuse peut être
allumée même quand l'humidificateur est
arrêté.
Figure 7
Voyant de
remplissage
Commande
de mise en
marche/
vitesse
Voyant
d’humidité
désirée
Humidostat
réglable
Commande
de veilleuse
NiteGlo™
Voyant de
remplissage
Pour Modèles 34301, 34351, 37300 et 37350
Humidostat réglable: vous permet de régler
la quantité d’humidité à diffuser. Une fois que
le bon niveau est atteint, l’appareil reste arrêté
jusqu’au moment où le niveau d’humidité tombe.
Note: Si l’humidificateur ne fonctionne pas, il
peut être nécessaire de régler l’humidostat.
Voyant d’humidité désirée: Le voyant vert
sera allumé quand l’humidité dans la pièce a
atteint le niveau que vous avez choisi sur le
bouton de l’humidostat.
Commande de mise en marche/vitesse: Met
en marche et arrête l’humidificateur. Il faut
toujours arrêter l’humidificateur avant de le
débrancher, de la déplacer ou de remplir le
réservoir d’eau.
Voyant de remplissage: Le voyant rouge
s’allume pour vous signaler que l’humidificateur
s’est arrêté automatiquement et que le réservoir
d’eau doit être rempli.
Figure 6
Commande
de mise en
marche/
vitesse
Voyant
d’humidité
désirée
Humidostat
réglable
41554-05 06/09/2004 19 © 2004 HUNTER FAN CO.
1. Déballez l’humidificateur à évaporation The
Care Free
®
Humidifier Plus. Lisez et conser-
vez les instructions.
2. Placez l’humidificateur sur une surface
dure, horizontale et qui résiste à l’eau. Pla-
cez toujours l’humidificateur à au moins
15 cm (6 pouces) des murs et des sources
de chaleur.
3. Soulevez le carter principal pour vérifier que les
filtres PermaWick™ sont placés droits dans les
encoches. Remettez le carter principal en place.
(Voir figure 1.)
4. Enlevez le réservoir d’eau et emmenez-le vers
l’évier ou la baignoire pour le remplir.
5. Retournez le réservoir et dévissez le bouchon
de réservoir en le faisant tourner dans le sens
inverse des aiguilles d’une montre.
Remplissez le réservoir d’eau froide et
remettez le bouchon (n’employez jamais
d’eau chaude). Faites attention de ne pas trop
remplir le réservoir car vous risquez d’abîmer
les meubles ou le sol si l’eau déborde. HUNTER
N’ACCEPTE AUCUNE RESPONSABILITÉ EN
CAS DE DÉGÂTS CAUSÉS PAR UN
RENVERSEMENT DE L’EAU.
6. Ramenez le réservoir vers l’humidificateur.
Remettez-le à l’endroit et placez-le sur
l’humidificateur. Assurez-vous que le réservoir
est placé correctement dans la base. Si le
réservoir est bien mis dans la base, vous
pourrez voir des bulles d’air remonter à la
surface du réservoir.
7. En gardant le bouton de commande dans la
position arrêt (OFF), branchez l’humidificateur
dans la prise murale.
ATTENTION : Ne branchez jamais
l’humidificateur avec des mains mouillées
car vous risquez une secousse électrique.
8. Employez le bouton de commande pour
mettre l'humidificateur en marche en
choisissant un réglage de vitesse.
Emploi de votre humidificateur
Seulement pour les modèles avec un
humidostat réglable
9. Vous pouvez choisir une diffusion
d’humidité désirée grâce au bouton de
réglage de l’humidostat. Dans une pièce
très sèche, le réglage “haut” (HI) doit être
employé pour apporter rapidement un
niveau d’humidité confortable. Une fois
que la pièce est confortable, vous pouvez
régler l’humidostat vers le bas. Le choix du
niveau d’humidité est un choix personnel
et vous pouvez le régler au niveau que vous
estimez le plus agréable. Nous vous
suggérons d’essayer un réglage moyen
entre le plus haut et le plus bas, puis de le
régler au niveau qui vous convient le mieux.
10. Quand l’humidité atteint le niveau choisi,
le voyant “humidité désirée” s’allume.
L’humidificateur ne diffuse pas d’humidité
quand la pièce est au niveau d’humidité
choisi. Le voyant “d’humidité désirée”
restera allumé tant que l’humidité ne
change pas. Quand l’humidité tombe en
dessous du niveau choisi, l’humidificateur
se remet en marche et le voyant
“d’humidité désirée” s’éteint.
Seulement pour les modèles avec arrêt
automatique
11.Quand le réservoir d’eau est vide,
l’humidificateur s’arrête
automatiquement. Le voyant rouge
s’allumera pour indiquer que le réservoir
d’eau doit être rempli.
12. Suivez les indications de REMPLISSAGE DU
RÉSERVOIR D’EAU. Une fois le réservoir
rempli, le voyant rouge s’éteindra.
Seulement pour les modèles avec veilleuse
NiteGlo™
13. Employez la commande pour allumer et
éteindre la veilleuse. La veilleuse peut être
allumée même quand l'humidificateur est
arrêté.
41554-05 06/09/2004 20 © 2004 HUNTER FAN CO.
Nettoyage de l’humidificateur et du réservoir d’eau
Remplissage du réservoir d’eau
1. Quand le niveau dans le réservoir d’eau est
bas, arrêtez l’humidificateur et débranchez-le.
2. Enlevez le réservoir d’eau et emmenez-le
vers l’évier ou la baignoire pour le remplir.
3. Retournez le réservoir et dévissez le
bouchon de réservoir en le faisant tourner
dans le sens inverse des aiguilles d’une
montre. Remplissez le réservoir d’eau froide
et remettez le bouchon (n’employez jamais
d’eau chaude). Faites attention de ne pas
trop remplir le réservoir car vous risquez
d’abîmer les meubles ou le sol si l’eau
déborde. HUNTER N’ACCEPTE AUCUNE
RESPONSABILITÉ EN CAS DE DÉGÂTS
CAUSÉS PAR UN RENVERSEMENT DE L’EAU.
4. Ramenez le réservoir vers l’humidificateur.
Remettez-le à l’endroit et placez-le sur
l’humidificateur. Assurez-vous que le
réservoir est placé correctement dans la
base. Si le réservoir est bien mis dans la
base, vous pourrez voir des bulles d’air
remonter à la surface du réservoir.
De nombreuses régions ont de l’eau dure avec
de hautes concentrations en minéraux. Quand
l’eau s’évapore de l’humidificateur à
évaporation The Care-Free
®
Humidifier Plus,
certains minéraux peuvent rester. Ces minéraux
peuvent former un dépôt de tartre blanc et dur
que l’on peut enlever en suivant les instructions
de nettoyage. La fréquence des nettoyages dus
à des dépôts minéraux varie selon la qualité de
votre eau.
Référez-vous à la Figure 1 pour les noms des
pièces.
1. Arrêtez l’humidificateur et débranchez-le.
2. Soulevez le carter principal et retirez le pla-
teau de dispersion d'eau et les filtres
PermaWick™. Le moteur est fixé au
carter principal. Ne placez pas le moteur
à proximité de l’eau. N’employez pas
de serviette humide sur le moteur ou le
carter du moteur car vous risquez une
secousse électrique.
3. Le filtre antibactérien PermaWick™ doit
être nettoyé dans une solution d’eau
vinaigrée pour enlever l’accumulation de
minéraux. Placez-le dans une solution de 4
litres d'eau pour un 250 cl de vinaigre non
dilué. Laissez tremper le filtre pendant 20
minutes.
4. Après le trempage, rincez-le plusieurs fois à
l’eau propre. Placez le filtre PermaWick™
dans un endroit où il peut sécher par
égouttage tandis que vous nettoyez le reste
de l’humidificateur.
5. Enlevez le réservoir d’eau de la base et videz
l’eau qui reste dans le réservoir. Remplissez
le réservoir d’eau d’un mélange de 4 litres
d’eau et de 25 cl de vinaigre pendant 20
minutes.
6. Après le trempage, essuyez la base avec un
chiffon doux ou une éponge pour enlever
l’accumulation de minéraux. Rincez
plusieurs à l’eau propre. Si vous avez
l’intention de ranger l’humidificateur,
assurez-vous que la base est bien sèche.
7. Remplissez le réservoir de 4 litres d’eau et
25 cl de vinaigre blanc non dilué. Remettez
le bouchon du réservoir en place et secouez
vigoureusement le réservoir jusqu’à ce que
toutes les surfaces intérieures du réservoir
aient été exposées au mélange eau et
vinaigre.
8. Videz l’eau vinaigrée du réservoir. Rincez le
réservoir plusieurs fois à l’eau propre et
remettez le bouchon en place. Si vous avez
l’intention de ranger l’humidificateur,
séchez-le bien et laissez-le ouvert (sans le
bouchon) pour qu’il sèche complètement.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Hunter Fan 37282 Le manuel du propriétaire

Catégorie
Humidificateurs
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues