Mist AP41 Guide d'installation

Catégorie
Antennes réseau
Taper
Guide d'installation
1
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
AP41 Hardware Installation Guide
Overview
The Mist AP41 delivers 4x4 MIMO with four spatial streams when operating in
multi-user (MU) or single-user (SU) mode that supports the IEEE 802.11ac
Wave 2 specification.
2
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
I/O ports and Kensington lock
Reset Reset to the factory default settings
USB USB2.0 support interface
12VDC Support for the 12VDC power supply recommended by Mist
IoT 8-pin interface for digital input, digital output, analog
input, and ground
Module 10/100/1000 BaseT RJ45 interface
Eth1 10/100/1000 BaseT RJ45 interface
Eth0+PoE 10/100/1000 BaseT RJ45 interface that supports 802.3at
PoE PD
3
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
AP41 Mounting
In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head
with a length at least 2 in. (50.8mm).
4
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
5
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
6
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
7
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
8
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
The bracket attaches to a rod that is 5/8”-11.
The bracket attaches to a rod that is M16-2.
9
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
Technical Specifications:
Feature Description
Power options 802.3at PoE
12V/3A DC power supply
Powering adaptor 100-240VAC, 50-60 Hz, input
All regions (output): 12V/3A DC output
Dimensions 215mm x 215mm x 52mm (8.46in x 8.46in x 2.05in)
Weight 1.6 kg (3.53 lbs)
Operating
temperature
Internal antenna 0° to 40° C
External antenna -20° to 50° C
Operating humidity 10% to 90% maximum relative humidity, non-condensing
Operating altitude 3,048m (10,000 ft)
Electromagnetic
emissions FCC Part 15 Class B
I/O
1 - 10/100/1000BASE-T auto-sensing RJ-45 with PoE
1 – 10/100/1000BASE-T auto-sensing RJ-45
1 – 10/100/1000BASE-T auto-sensing RJ-45
USB2.0
IoT terminal block
12VDC
RF
2.4GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO
5GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO
2.4GHz / 5GHz scanning radio
2.4GHz BLE with Dynamic Antenna Array
Maximum PHY rate
Total maximum PHY rate – 2533Mbps
5GHz – 1733 Mbps
2.4GHz – 800Mbps
Indicators Multi-color status LED
Compliance standards
UL 60950-1 & CAN/CSA-C22.2 No. 60950-1
UL 2043
FCC Part 15.247, 15.407, 15.107, and 15.109
RSS-247 & ICES-003 (Canada)
EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
EN 300 328 V2.1.1
EN 301 893 V2.1.1
EN 50385: 2002
IEC/EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 +
A2:2013
EN 55032:2015 + AC:2016, Class B
Suitable for use in environmental air space in accordance with Section 300-22(C) of the
National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian
Electrical Code, Part 1, CSA C22.1.
Warning: The AP must be mounted only horizontally if you mount it into a plenum
space.
10
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
Warranty Information
The AP41 family of Access Points comes with a limited lifetime warranty.
Ordering Information:
Access Points
AP41-US Premium Wi-Fi & BLE Array AP with internal antennas
for the US Regulatory domain
AP41E-US Premium Wi-Fi & BLE Array AP with external antenna
connectors for the US Regulatory domain
AP41-WW Premium Wi-Fi & BLE Array AP with internal antennas
for the WW Regulatory domain
AP41E-WW Premium Wi-Fi & BLE Array AP with external antenna
connectors for the WW Regulatory domain
Mounting brackets
APBR
-
U
Universal AP Bracket for T
-
for Indoor Access Points
AP41BR1 Premium AP T-bar ceiling mounting bracket kit
AP41BR2 Premium AP drywall ceiling mounting bracket kit
APBR-T58 /
AP41BR3
5/8-inch threaded rod bracket
APBR-M16 /
AP41BR4
16mm threaded
rod
bracket
APBR-ADP-CR9 /
AP41BR1-CR
Adapter for channel rail and recessed 9/16” t-rail
APBR-ADP-RT15 /
AP41BR1-RT
Adapter for recessed 15/16" t-rail
APBR-ADP-WS15
Adapter for recessed
1
.
5"
t
-
rail
11
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
Power Supply options
DC-01 100-240VAC, 50-60 Hz, input
All regions (output): 12V/3A DC output
This product is intended to be supplied by an approved limited power source (adapter
label marked with L.P.S. or LPS) with an output rated 12Vdc/3A minimum or 50-
57Vdc/600mA minimum which has an operating temperature range of 50C and
operating altitude of 3,048 meters.
If using a class I adapter / power injector, the power cord needs to be connected to
the outlet utilizing the ground pin.
Antennas
M6060060MP1D43620 Ventev Patch Antenna, 6dBi/6dBi (2.4GHz/5GHz)
PDQ24518-MI1 Laird Patch Antenna 8dBi/8dBi (2.4GHz/5GHz)
Regulatory Compliance Information:
This product and all interconnected equipment must be installed indoors within the
same building, including the associated LAN connections as defined by the 802.3at
Standard.
Operations in the 5.15GHz – 5.35GHz band are restricted to indoor usage only.
If you need further assistance with purchasing the power source, please contact Mist
Systems, Inc.
12
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
FCC Requirement for Operation in the United States of
America:
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 35cm between the radiator & your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is
restricted to indoor environment.
13
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
Industry Canada
This device complies with RSS-247 of the Industry Canada Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Ce dispositif est conforme à la norme CNR-247 d'Industrie Canada applicable aux
appareils radio exempts de licence. Son fonctionnement est sujet aux deux
conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable,
et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage
susceptible de provoquer un fonctionnement indésirable.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 44cm between the radiator & your body.
Déclaration d'exposition aux radiations:Cet équipement est conforme aux limites
d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec un minimum de 44 cm de distance entre
la source de rayonnement et votre corps.
IC Caution
(i) The device for operation in the band 5150-5250 MHz is only for indoor use to
reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz
and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p.
limit;
(iii) The maximum antenna gain permitted for devices in the band 5725-5850 MHz
shall be such that the equipment still complies with the e.i.r.p. limits specified for
point-to-point and non-point-to-point operation as appropriate; and
(iv) Users should also be advised that high-power radars are allocated as primary
users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that
these radars could cause interference and/or damage to LE-LAN devices.
Avertissement
Le guide d’utilisation des dispositifs pour réseaux locaux doit inclure des instructions
précises sur les restrictions susmentionnées, notamment :
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés
uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage
préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;
14
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
(ii) le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250
à 5 350 MHz et de 5470 à 5725 MHz doit être conforme à la limite de la p.i.r.e;
(iii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5 725
à 5 850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation
point à point et l’exploitation non point à point, selon le cas;
(iv) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars
de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la
priorité) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars
pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
15
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
CE
This device complies with the Radio Equipment Directive, 2014/53/EU, issued by the
Commission of the European Community.
Hereby, Mist Systems, Inc. declares that the radio equipment type (AP41) is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following:
https://www.mist.com/support/
The frequency and maximum EIRP Power in EU:
Bluetooth:
Frequency range (MHz)
Maximum EIRP in EU (dBm)
2400 – 2483.5 9.43
WLAN:
Frequency range (MHz) Maximum EIRP in EU (dBm)
2400 – 2483.5 19.84
5150
5250
22.90
5250 – 5350 22.68
5500
5700
29.62
South Korea
해당 무선설비는 운용 전파혼신 가능성이 있음
Brazil
Este equipamento não tem direito à proteção contra interferência prejudicial e não
pode causar interferência em sistemas devidamente autorizados
Taiwan
本器材之WLAN介面於工作頻率5.150 ~ 5.250GHz 該頻段限於室使用。
高增益指向性天線只得應用於固定式點對點系統
低功率警語:
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、 加大功率
或變更原設計之特性及功能
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改
善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須
忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
應避免影響附近雷達系統之操作。
16
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
Pakistan
Russia
Подтверждение соответствия 1)Минкомсвязи России и 2) Евразийского
Таможенного Союза:
1. Декларация соответствия Евразийского Таможенного Союза № RU Д-
US.PA01/B.64313/19 от (09.08.2019) года, действительна до (08.08.2022) года,
зарегистрирована в реестре Евразийского Таможенного Союза (09.08.2019) года
2. Сертификат соответствия № OC-2-PД-1294 от (04.10.2019) года, действителен
до (04.10.2022) года, зарегистрирован в Федеральном агенстве связи
(04.10.2019) года
3. Декларация соответствия № UBPД – 6420 от (01.11.2019) года, действительна
до (01.11.2025) года, зарегистрирована в Федеральном агенстве связи
(14.11.2019) года
4. Декларация соответствия № UBPД – 6419 от (01.11.2019) года, действительна
до (01.11.2025) года, зарегистрирована в Федеральном агенстве связи
(14.11.2019) года
Mexico
La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es
posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este
equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda
causar su operación no deseada
Este equipo ha sido diseñado para operar con las antenas que enseguida se enlistan
y para una ganancia máxima de antena de [8] dB. El uso con este equipo de antenas
no incluidas en esta lista o que tengan una ganancia mayor que [8] dB quedan
prohibidas. La impedancia requerida de la antena es de [50] ohms.
Belarus
Thailand
17
AP41 Hardware Installation Guide
Mist Systems (C) Copyright 2016-2020. All Rights Reserved
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Mist AP41 Guide d'installation

Catégorie
Antennes réseau
Taper
Guide d'installation

dans d''autres langues