Watchguard AP327X Hardware Guide

Catégorie
Antennes réseau
Taper
Hardware Guide
WatchGuard
AP327X
Hardware
Guide
AP327X / O-105E
Outdoor Access Point
ii WatchGuard AP327X
ADDRESS
505 Fifth Avenue South
Suite 500
Seattle, WA 98104
SUPPORT
www.watchguard.com/support
U.S. and Canada +877.232.3531
All Other Countries +1.206.521.3575
SALES
U.S. and Canada +1.800.734.9905
All Other Countries +1.206.613.0895
ABOUT WATCHGUARD
WatchGuard® Technologies, Inc. is a global leader of integrated, multi-function
business security solutions that intelligently combine industry standard hardware,
best-of-breed security features, and policy-based management tools. WatchGuard
provides easy-to-use, but enterprise-powerful protection to hundreds of thousands of
businesses worldwide. WatchGuard is headquartered in Seattle, Wash. with offices
throughout North America, Europe, Asia Pacific, and Latin America.
To learn more, visit WatchGuard.com.
Copyright and Patent Information
Copyright© 2019 WatchGuard Technologies, Inc. All rights reserved.
WatchGuard, the WatchGuard logo, LiveSecurity, and any other mark listed as a trademark in the “Terms of Use” portion of
the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Technologies,
Inc. and/or its subsidiaries in the United States and/or other countries. All other trademarks are the property of their
respective owners.
Printed in the United States of America.
Revised: November 21, 2019
Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this guide may be
reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express
written permission of WatchGuard Technologies, Inc.
Complete copyright, trademark, patent, and licensing information can be found in
the WatchGuard product documentation. You can find this document online at:
https://www.watchguard.com/help
Hardware Guide 1
Hardware Specifications
The WatchGuard® AP family of wireless access points provide secure, reliable, wireless communications while
delivering high performance and broad coverage—a perfect combination of services to meet the needs of
enterprise-level customers, small businesses, branch offices, campuses, and hotels alike.
The WatchGuard AP327X is intended for outdoor use and features an IP67 waterproof rating, 2X2 MU-MIMO
802.11ac Wave 2 capabilities, and dual radios that support 2.4GHz (802.11b/g/n) and 5GHz (11a/n/ac) to
provide wireless clients with enhanced reliability and performance. Power can be provided by any PoE+
(Power over Ethernet) power source.
There are two ways you can manage your AP327X:
Total Wi-Fi and Secure Wi-Fi with WatchGuard Wi-Fi Cloud
A powerful cloud-based enterprise wireless management solution for AP configuration, security, and
monitoring.
Basic Wi-Fi with WatchGuard Firebox Gateway Wireless Controller
Local management, configuration, security, and monitoring of APs directly from your WatchGuard
Firebox. The WatchGuard Firebox requires Fireware v12.5 and higher.
For more information about how to set up and manage your WatchGuard AP, you can find documentation
online at: https://www.watchguard.com/help
Package Contents
WatchGuard AP327X
Quick Start Guide
Wall-mount accessories and stencil
Pole mount accesorries
Ground wire
2 WatchGuard AP327X
Hardware Specifications
About Your Hardware
Hardware Specifications
Environmental Requirements
To safely install your WatchGuard AP, we recommend that you:
Install the device indoors or outdoors, preferably under cover.
Make sure the device has adequate clearance for air flow and cooling.
Other environmental requirements:
AP327X
IP Rating IP67
Radio Type and
Frequency Band
2.4GHz, 802.11b/g/n. Max data rate: 300 Mbps
5GHz, 802.11a/n/ac. Max data rate: 867 Mbps
Antenna 2 N-Type external antennas 2.4 GHz
2 N-Type external antennas 5 GHz
Diminsions: 7.3” x 0.83” x 0.83” (186.0mm x 21.2mm x21.2mm)
Weight: 0.35 lbs (0.14 kg) / per pair
* Sold separately
Ethernet interface 1 x 10/100/1000 Mbps Gigabit Ethernet (LAN1)
802.3at PoE+ capable
1 x 10/100/1000 Mbps Gigabit Ethernet (LAN2) for wired extension
Power Interface LAN1 PoE+ (802.3at), 48V
Power
Consumption
Max: 19 W
Min: 11 W
Average: 16 W
MTBF (Mean Time
Between Failures)
4,544,476 hours at 25°C / 77°F
998,437 hours at 65°C / 149°F
Dimensions 8.42” x 8.42” x 2.66” (213.9mm × 213.9mm × 67.5mm)
Weight 3.95 lbs (1.78 kg)
Operating temperature -40°C to 65°C (-40°F to 149°F)
Operating relative humidity 5% to 95% non-condensing
Non-operating temperature -40°C to 70°C (-40°F to 158°F)
Non-operating relative humidity 5% to 95% non-condensing
Hardware Guide 3
Hardware Specifications
Hardware Description
Device Connections and Buttons
Ethernet Network Interfaces
LAN1: Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps and 802.3at PoE+
connectivity. The WatchGuard AP327X can be powered by an PoE+ connection on the LAN1
interface.
LAN2: Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps. This interface can be
used as a wired extension for a wireless SSID that has NAT enabled. For more information on how to
configure NAT settings for an SSID, see the WatchGuard Wi-Fi Cloud Help.
For APs managed locally by a Gateway Wireless Controller, you can bridge together the LAN ports on
AP models that have two LAN interfaces. This enables you to extend the wired network on the LAN2
interface. For more information, see the Fireware Help.
Reset Button
Resets the WatchGuard AP to factory-default settings.
You must use a Phillips screwdriver to remove the cover screw for the reset button. Use a paper clip
or other small object to press the reset button through the hole.
Press and hold the reset button for up to 10 seconds until all LEDs go off to indicate that the AP has
rebooted
4 WatchGuard AP327X
Hardware Specifications
Device Indicators
The AP327X has these LED indicators:
AP Firmware 8.8.1 and Higher
LED
Status
Power LAN 1 and
LAN2
2.4 GHz and 5 GHz
Radios
Off Powered off. No Ethernet
link.
Radio inactive.
Green Powered on. Operating at normal
power and capabilities.
(PoE+ or DC power)
Connected at
10/100/1000
Mbps.
Radio active.
Flashing
Green
Not connected to Wi-Fi Cloud or
paired with a Gateway Wireless
Controller.
--
Orange Powered on. Operating at reduced
power and capabilities.
(For example: PoE 802.3af)
See AP Power Requirements
.
- -
Flashing
Orange
No IP address received from DHCP. - -
Hardware Guide 5
Hardware Specifications
AP Firmware 8.8.0 and Lower
LED
Status
Power LAN 1 and
LAN2
2.4 GHz and 5 GHz
Radios
Off Powered off. No Ethernet
link.
Radio inactive.
Green Powered on. Connected at
10/100/1000
Mbps.
Radio active. No clients
connected.
Flashing
Green
- Network
activity.
Wireless radio activity.
6 WatchGuard AP327X
Hardware Specifications
Mounting Instructions
Your package includes pole-mount and wall-mount accessories for your AP.
The MAC address and serial number of your AP are printed on a label on the back of the device.
Make sure you record this information before you mount the AP.
Pole Mount Installation
Use the supplied pole-mounting accessories to install the AP327X on a pole.
1. Place the AP on the pole.
2. Insert the clamps in the slots on the AP and wrap around the pole.
3. Fasten the screws and make sure the AP is firmly attached to the pole.
Hardware Guide 7
Hardware Specifications
Wall Mount Installation
Use the supplied wall-mounting accessories to install the AP327X on a wall.
1. Use the included stencil to drill holes on the wall for the anchors.
2. Insert the four anchors.
3. Affix the mounting bracket to the wall with the included anchor screws.
4. Attach the AP to the mounting bracket.
5. Insert the mounting screws in the slots of the mounting bracket.
6. Fasten the screws.
8 WatchGuard AP327X
Hardware Specifications
Connect the Ground Wire
To make sure your outdoor AP is safely protected from electrical events, we recommend you ground the AP
according to your local regulations.
Use the included screw to attach the ground wire to the ground connector on the back of the AP and to a
nearby grounding point.
Hardware Guide 9
Hardware Specifications
Antenna Installation
WatchGuard dual-band omnidirectional dipole antennas (WG9004) are sold separately in packs of two
antennas.
On the top of the AP327X, there are two N-type connectors each for the 2.4 GHz radio and the 5 GHz radio.
Insert the antennas into the connectors and turn clockwise to tighten.
You can use a combination of WatchGuard omnidirectional and other third-party omnidirectional and
directional antennas based on your deployment requirements.
If you use other third-party antenna types, you are responsible for verifying compliance with regional
based regulations on Equivalent Isotropically Radiated Power (EIRP). The maximum power output +
antenna gain = EIRP. For example, the maximum EIRP defined by the FCC in the U.S. for 2.4 GHz is 30
dBm (1 Watt), and 5GHz is 5.15-5.25 23 dBm (200mW), 5.25-5.35 30dBm (1W), and 5.72-5.85 36 dBm
(4W).
10 WatchGuard AP327X
Hardware Specifications
Connect the AP
To power on and connect the AP327X to the network:
1. Plug one end of an Ethernet cable into the LAN1 (PoE) port on the AP.
Make sure you insert the Ethernet cable correctly through the waterproof assembly before you tighten
the LAN port cap.
2. Plug the other end into a PoE+ (802.3at) compatible switch or PoE+ injector.
Hardware Guide 11
Hardware Specifications
How to Assemble the Weatherproof Connector
Use these instructions to connect the Ethernet cable to the AP through the weatherproof connector.
12 WatchGuard AP327X
Hardware Specifications
How to Disassemble the Weatherproof Connector
Use these instructions to disconnect the Ethernet cable from the weatherproof connector.
Hardware Guide 13
Hardware Specifications
Ethernet Power Injector (Optional)
You can also power the AP327X with an optional Ethernet Power Injector. The PoE+ power injector enables
you to power the AP through an existing Ethernet connection. With this device, you do not have to position
your AP near a power outlet.
This device complies with IEEE 802.3at/af PoE specifications. Do not use any PoE adapters that are not
IEEE 802.3at/af compliant as they may damage your device.
Connect the Ethernet Power Injector
To connect an Ethernet Power Injector to the WatchGuard AP:
1. Plug the Ethernet Power Injector into an AC power source.
2. Connect an Ethernet cable from your network backbone (for example, PoE+ capable router, switch, or
hub) to the LAN connector on the Ethernet Power Injector.
3. Connect an Ethernet cable from the LAN1 (PoE) interface on the AP to the PoE port on the Ethernet
Power Injector.
14 WatchGuard AP327X
Hardware Specifications
Ethernet Power Injector Specifications
Ethernet Power Injector
WatchGuard Part # 802.3at PoE+ Injector with AC cord (US/FCC) (WG8599)
802.3at PoE+ Injector with AC cord (CE) (WG8600)
802.3at PoE+ Injector with AC cord (UK) (WG8601)
802.3at PoE+ Injector with AC cord (AUS) (WG8602)
Specification IEEE 802.3at/af
AC Input Voltage Rating 100 to 240VAC
Input Current 0.8A Max for 100VAC
Output Power 30W maximum
Ethernet Interfaces LAN: RJ-45 for 10/100/1000 Mbps data
POE: RJ-45 for 10/100/1000 Mbps data and power
Voltage: Pin4, 5:54V, Pin7, 8:Return
Indicator Power: Green
Temperature Operating: 0°C to 40°C (32°F to 104°F)
Storage: -30°C to 80°C (-22°F to 176°F)
Humidity 5 to 90% (Operating and storage)
Dimensions L = 3.9” (99 mm)
W = 2.27” (68.5 mm)
H = 1.3” (33 mm)
Weight 0.33 lbs (149.6 g)
Hardware Guide 15
Legal and Regulatory Information
Safety Notices
All WatchGuard products are designed and tested to meet strict safety requirements. These requirements
include product safety approvals and other global compliance standards. Read these instructions carefully
before you operate the product, and refer to them as needed for continued safe operation of your product.
Product Safety Certification
The WatchGuard product is safety certified under the following standards:
IEC 60950-1:2005 (Second Edition)+Am 1:2009+Am 2:2013
EN 60950-1:2006+A11+A1+A12+A2:2013
EN 55024:2010
EN 55032:2015/AC/2016
EN 62311:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
Safety Warning
Do not place objects on the power cord.
Do not obstruct the ventilation openings. These openings prevent overheating of the machine.
Never push objects of any kind into slots or openings on this equipment. Making a contact with a
voltage point or shorting out a part may result in fire or electrical shock.
When removing or installing an appliance, follow the general installation safety instructions.
Disclaimer
WatchGuard shall not be held liable if the end user alters, modify, or repairs any WatchGuard hardware
appliance.
16 WatchGuard AP327X
Legal and Regulatory Information
HINWEISE ZUR SICHERHEIT
Alle WatchGuard Produkte werden entwickelt und getestet, um strenge Sicherheitsanforderungen zu
erfüllen. Diese Anforderungen umfassen Produktsicherheit Zulassungen und andere globale Compliance-
Standards. Bitte lesen Sie die folgenden Anweisungen sorgfältig, bevor Sie das Produkt, und bezeichnen sie
als notwendig, um den sicheren Betrieb des Geräts zu gewährleisten. Weitere Informationen finden Sie in der
elektronischen Hardware Guide.
Die WatchGuard Produkt ist Sicherheit unter den folgenden Normen zertifiziert:
IEC 60950-1:2005 (Second Edition)+Am 1:2009+Am 2:2013
EN 60950-1:2006+A11+A1+A12+A2:2013
EN 55024:2010
EN 55032:2015/AC/2016
EN 62311:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
Sicherheitshinweis
Legen Sie keine Gegenstände auf das Netzkabel.
Verdecken Sie nicht die Lüftungsöffnungen. Diese Öffnungen verhindern eine Überhitzung der
Maschine.
Stecken Sie niemals Gegenstände jeglicher Art in die Schlitze oder Öffnungen des Geräts stecken. Der
Kontakt mit einem spannungsführenden Punkt oder das Kurzschließen eines Bauteils kann zu einem
Brand oder elektrischen Schlag führen.
Beim Entfernen oder Installieren eines Gerätes, nach den allgemeinen Installation Sicherheitshinweise.
AVISO DE SEGURIDAD
Todos los productos WatchGuard están diseñados y probados para satisfacer estrictos requisitos de
seguridad. Estos requisitos incluyen la homologación de productos de seguridad y otras normas de
cumplimiento global. Por favor, lea atentamente las siguientes instrucciones antes de utilizar el producto, y se
refieren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto.
Información adicional se puede encontrar en la Guía del usuario electrónica.
Certificación de seguridad del producto
El producto tiene certificación de seguridad WatchGuard bajo las siguientes normas:
IEC 60950-1:2005 (Second Edition)+Am 1:2009+Am 2:2013
EN 60950-1:2006+A11+A1+A12+A2:2013
EN 55024:2010
EN 55032:2015/AC/2016
EN 62311:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
Advertencia de seguridad
No coloque objetos sobre el cable de alimentación.
No obstruya las aberturas de ventilación. Estas aberturas evitan el sobrecalentamiento de la máquina.
Nunca introduzca objetos de ningún tipo en las ranuras o aberturas del equipo. El contacto con puntos
de voltaje o el cortocircuito de una pieza podría provocar un incendio o una descarga eléctrica.
Al extraer o instalar un electrodoméstico, siga las instrucciones generales de instalación de seguridad.
Hardware Guide 17
Legal and Regulatory Information
FCC Certification
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
* FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is restricted to indoor environment.
The band from 5600-5650MHz will be disabled by the software during the manufacturing and cannot be
changed by the end user. This device meets all the other requirements specified in Part 15E, Section 15.407 of
the FCC Rules.
Section 15.204(b) states that an approved "transmission system" must always be marketed as a complete
system including the antenna. This device is restricted to indoor use.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 32cm between the radiator & your body.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other
channels is not possible.
Dieses Gerät wurde getestet und entspricht den Grenzwerten für ein Digitalgerät der Klasse B gemäß Teil 15
der Federal Communications Commission (FCC) Regeln einhalten. Diese Grenzwerte sollen einen
angemessenen Schutz vor schädlichen Störungen, wenn das Gerät in einer kommerziellen Umgebung
betrieben wird. Dieses Gerät erzeugt, verwendet und kann Hochfrequenzenergie abstrahlen, und wenn nicht
installiert und in Übereinstimmung mit der Bedienungsanleitung, kann es Störungen im Funkverkehr
verursachen. Der Betrieb dieses Gerätes in einem Wohngebiet wird wahrscheinlich schädliche Interferenzen
in dem Fall muss der Benutzer die Störungen auf seine / ihre eigene Kosten zu beheben.
18 WatchGuard AP327X
Legal and Regulatory Information
CE Notice
The CE symbol on your WatchGuard Technologies equipment indicates that it is in compliance with the
Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union
(EU).
This equipment should be installed and operated with minimum distance 32cm between the radiator & your
body.
All operational modes:
2.4GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40)
5GHz: 802.11a, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac (VHT40), 802.11ac (VHT80)
Industry Canada Certification
This device complies with ISED's licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d' ISED applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage
préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de
provoquer un fonctionnement indésirable.
IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 32 cm between the radiator & your
body.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement
non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 32 cm de distance entre la
source de rayonnement et votre corps.
Caution:
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for
harmful interference to co-channel mobile satellite systems;
les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à
l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les
mêmes canaux;
(ii) the maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall
be such that the equipment still complies with the e.i.r.p. limit;
le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250 à 5 350 MHz et de 5470 à
5725 MHz doit être conforme à la limite de la p.i.r.e;
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Watchguard AP327X Hardware Guide

Catégorie
Antennes réseau
Taper
Hardware Guide

dans d''autres langues