PNI CT60 Manuel utilisateur

Catégorie
Thermostats
Taper
Manuel utilisateur
Wireless thermostat/ Drahtloser Thermostat
Termostato inalámbrico/Thermostat sans fil
Vezeték nélküli termosztát/Termostato senza fili
Draadloze thermostaat/ Termostat bezprzewodowy
Termostat fara fir PNI CT60
EN - User manual .................. p. 2
DE - Benutzerhandbuch ....... p. 18
ES - Manual de usuario .......... p. 35
FR - Manuel de l’utilisateur ... p. 52
HU - Használati utasítás ........ p. 69
IT - Manuale dell’utente ......... p. 86
NL - Handleiding .................... p. 103
PL - Instrukcja obsługi ............ p. 120
RO - Manual de utilizare ........ p. 137
2
Introduction
This thermostat starts and stops the central heating
system based on a temperature limit and a preset time
period.
Special warnings
As the product must be connected to a 230V power
supply and to a heating equipment, the installation must
be carried out only by qualified personnel, in order to
avoid irreparable damage to the product or the heating
equipment to which it is connected.
Also, the first configuration of the equipment should be
performed by qualified personnel.
3
Technical specifications
Transmitter power supply 2 x AAA batteries 15.V
Receiver power supply 230VAC, max. 10A
Frequency 868 MHz
Interval of
set temperature +5°C ~ +35°C
Interval of
displayed temperature C ~ +50°C
Display Yes, backlighted
Sensor NTC 3950,
10KOhm@25°C
Accuracy ±0.1°C
Step 0.5°C
Temperature
measurement unit Only Celsius degrees
Water protection class IP30
Housing ABS with fireproof
standard UL94-5
4
Installation instructions
The thermostat can be mounted in 2 ways: on the table
or on the wall with the help of the brackets included in
the package.
Description of keys and icons
Day of the week
ON/OFF
Programming
Back
Eco mode
Programmed
mode
Up/Down
MenuCentral heating ON
Time
Period
Room
temperature
5
Pairing transmitter and receiver
Pairing button
Central heating ON indicator
LED 1
LED 2
Power indicator
Note: the two units come paired from the factory. Make
the pairing procedure only if there are communication
problems.
Long press the pairing button on the receiver unit.
LED 1 flashes frequently.
Turn o the transmitter unit by pressing the key.
Press and hold the MENU key on the transmitter unit
until the pairing code appears on the display (for example
FF FF 0). Immediately press the key. Another code
will flash on the screen. If the pairing was successful,
the code on the screen will disappear and LED 1 (green)
6
will turn o. Turn on the transmitter unit. If the set
temperature is higher than the room temperature, the
transmitter unit will send an RF signal to the receiver
unit, which, in turn, will send a ON command to the
boiler. In this situation, LED 1 (red) will remain lit.
Set the time and day of the week
Hold down the MENU key for 3 seconds. The minute
indicator will flash. Use the and keys to reach the
desired value. Briefly press the MENU key to confirm
and move to the time setting. The time indicator will
flash. Use the and keys to reach the desired value.
Briefly press the MENU key to confirm and move to
the day of the week setting (1 to 7). Press the MENU
key to exit.
Operation mode setup
Briefly press the MENU key to set the operation mode:
Scheduled, Manual or Holiday.
7
In Scheduled mode, the PRG icon appears on the right
side of the screen as in the image below:
In Manual mode, only the time, day and temperature
are displayed on the screen:
In Holiday mode (Economic), on the right side of the
screen appears an icon in the form of a suitcase as in the
image below:
8
Scheduled mode
Schedule by day
Briefly press the MENU key to set the Scheduled
operating mode.
Long press the PRG key for 3 seconds to enter the
programming menu.
The time* and temperature* will flash on the screen.
Each time you press the PRG key, the selected value will
be confirmed and you will move on to the next setting.
After setting the time and the temperature for the first
period, it automatically switches to the second period,
then to the third and fourth.
Thus will continue with the setting of the 4 periods for
each day of the week (1 - 7).
9
* Note: The time can be set from 15 to 15 minutes, and
the temperature from half to half a degree. For example,
you can set the time to 07:15 or 07:30 or 07:45 and the
temperature to 22.0°C or 22.5°C or 23.0°C.
Note: Briefly press the PRG key to confirm a setting. Press
the MENU key to exit.
Default settings
Period 1 2
Hour Temp. Hour Temp.
12345
(Mon-Fri) 07:00 22°C 08:30 19°C
6 (Sat) 08:00 22°C 08:30 22°C
7 (Sun) 08:00 22°C 08:30 22°C
Period 3 4
Hour Temp. Hour Temp.
12345
(Mon-Fri) 17:00 22°C 17:00 19°C
6 (Sat) 17:00 22°C 22:00 19°C
7 (Sun) 17:00 22°C 22:00 19°C
10
Note: Press the or key to display the set temperature
on the screen. Wait a few seconds, the screen will return to
room temperature display mode.
Functions
Key lock function
If the Child protection function has been activated
in the advanced settings menu (see page 12), the
thermostat keys will lock as soon as the screen backlight
turns o.
Press the MENU key for 5 seconds to temporarily
unlock the keys.
Open window detection (OWD)
If the function has been activated from the advanced
settings menu (see page 12), the thermostat will turn
o the heating if the room temperature drops suddenly
(default setting 2°C in 15 minutes). This sudden drop in
temperature occurs when a window or door is opened
while the boiler is operating. The OP icon appears on
the screen.
The device will return to its original operating mode after
11
30 minutes. The OP icon disappears from the screen.
By pressing any key, you will exit OWD mode.
Advanced settings
Switch o the thermostat by briefly pressing the key.
Press the MENU and keys simultaneously for about
6 seconds. 01 0.C will appear on the screen.
Use the and keys to change the settings and the
MENU key to move to the next setting.
Menu Description Range Default
01 Internal sensor
temperature
calibration
-8°C~8°C 0°C
02 Setting the
maximum
temperature
limit
5°C
~3C 35°C
03 Set minimum
temperature
limit
5°C
~3C C
12
05 Anti-freeze
temperature 5°C~15°C 5°C
09 Hysteresis 0.1~C 0.3°C
10 Screen display 0: room
temp.
1: set
temp.
0
11 Child
protection 0: keys
unlocked
1: keys
locked
0
12 Open window
detection 1: On
0: O 0
13 The time
interval in
which the
sudden drop in
temperature is
detected
2~30 min. 15 min.
13
14 Degrees lost
in the time
interval set at
menu 13
2°C
3°C
4°C
2°C
15 The time after
which the
device returns
to its original
mode of
operation
10~60
min 30 min.
17 Reset 0: No
1: Yes.
Press
for 5
seconds.
0
Software
version
14
Connection diagram
The connection of the receiver unit to a 230V power
supply and to a heating system must be performed only
by qualified personnel and only after prior consultation
of the technical documentation of the thermostat and
the heating system.
The receiver unit has a relay type control (NO Normal
Open and NC Normal Closed) without potential (non-
energized) which executes the closing of a control
circuit with a maximum current of 10A and a maximum
voltage of 250VAC/DC.
Find examples of connections with certain models of
heating system at the end of the manual.
15
Connections examples
Ariston CLAS EVO SYSTEM
Ferroli DivaCondens 24/28
16
Vaillant Ecotec Pure
Motan Max Optimus
17
Simplified EU declaration of conformity
SC ONLINESHOP SRL declares that PNI
CT60 Wireless Thermostat is in accordance with
RED Directive 2014/53/EU. The full text of the
EU Declaration of Conformity is available at the
following website:
https://www.mypni.eu/products/8001/download/
certifications
Drahtloses Thermostat
PNI CT60
Handbuch
19
Einführung
Dieses Thermostat schaltet die Heizung aufgrund
einer Temperaturgrenze und eines voreingestellten
Zeitraumes ein und aus.
Achtung
Das Produkt muss an eine Versorgungsquelle von
230V und an ein Heizungsgerät angeschlossen werden,
deshalb muss der Einbau durch Fachpersonal erfolgen,
so wird die unabänderliche Beschädigung des Produkten
und des Heizungsgerätes vermieden, diese möglichen
Schäden sind nicht in der Garantie eingeschlossen.
Für die erste Konfigurierung des Gerätes empfehlen wir
Ihnen Fachpersonal zu Rate zu ziehen.
20
Technische Spezifikationen
Versorgung Sender 2 x Batterien AAA
Versorgung Empfänger 230VAC, höchstens 10A
Frequenz 868 MHz
Eingestellter
Temperaturbereich +5°C ~ +35°C
Angezeigter
Temperaturbereich C ~ +50°C
Bildschirm Ja, beleuchtet
Sensor NTC 3950,
10KOhm@25°C
Genauigkeit Messung ±0.1°C
Temperaturschritt 0.C
Messeinheit Temperatur Nur Celsiusgrad
Schutzklasse Wasser IP30
Gehäuse ABS mit Standard
Gegenfeuer UL94-5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154

PNI CT60 Manuel utilisateur

Catégorie
Thermostats
Taper
Manuel utilisateur