1 Version Tracking ................................................................................................... 4
2 OEM Notice ............................................................................................................... 5
3 Product Overview .................................................................................................. 6
4 External Interfaces ................................................................................................ 6
4.1 Overview ....................................................................................................................................... 6
4.2 Pinout ............................................................................................................................................ 6
4.3 USB-C ............................................................................................................................................. 6
5 LED’s ........................................................................................................................... 7
5.1 Overview ....................................................................................................................................... 7
5.2 ORANGE LED ................................................................................................................................. 7
5.3 GREEN LED ..................................................................................... Error! Bookmark not defined.
5.4 BLUE LED ....................................................................................................................................... 7
6 Power Supply .......................................................................................................... 7
7 Testing Environment ............................................................................................ 8
8 Software Tools ........................................................................................................ 8
9 Initial setup ............................................................................................................. 8
10 Control Interface .................................................................................................... 9
11 Cellular Information ............................................................................................. 9
11.1 Query normal ................................................................................................................................ 9
11.2 Query no SIM .............................................................................................................................. 10
12 GPS Information ................................................................................................... 10
13 Input/Outputs ....................................................................................................... 11
13.1 Overview ..................................................................................................................................... 11
13.2 Digital inputs ............................................................................................................................... 11
13.3 Open-drain outputs..................................................................................................................... 11
13.4 Connecting a load ....................................................................................................................... 12
PT40 OEM USER MANUAL
Pacific Track, LLC 3
13.5 1-Wire™ interface .......................................................................... Error! Bookmark not defined.
13.6 Serial interface ............................................................................................................................ 12
PT40 OEM USER MANUAL
Pacific Track, LLC 4
1 Version Tracking
Version
Date
Change
0.1
1
1
21
Initial Version
1.0
5
/2
5
/2019
Published
PT40 OEM USER MANUAL
Pacific Track, LLC 5
2 OEM Notice
This user manual is provided to OEM and Resellers of Pacific Track’s products. It is not intended to be
used by end users.
OEM and Resellers should include the following notices in a prominent location in the instruction
manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the
device is marketed:
Product Marketing Name: Telematics Device
FCC ID: 2ALBDPT10
IC : 23259-PT10
This equipment complies with FCC radiation exposure limits and Canada radiation RF exposure limits
set forth in CFR 47 Sections 2.1091 and ISED RSS-102 for an uncontrolled environment. This equipment
should be installed and operated with a minimum distance of 20 cm between the radiator and the
body. This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Cet équipement est conforme aux limites d'exposition aux rayonnements de la FCC et aux limites
d'exposition aux rayonnements RF du Canada énoncées dans les sections 2.1091 du CFR 47 et ISED RSS-
102 pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance
minimale de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être colocalisé ou
fonctionner en conjonction avec une autre antenne ou émetteur.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following
two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation
of the device.”
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
PT40 OEM USER MANUAL
Pacific Track, LLC 6
3 Product Overview
The PT10 is a cellular device that can be used for telematics application. The PT10 can be powered with
a basic power-only connection (aka 2-wire). The PT10 can also monitor the ignition pin (3-wire
installation).
The PT10 can be programmed to run complex applications schemes based on locally generated events
and states using the VTX™ web-based platform.
4 External Interfaces
4.1 Overview
The PT10 uses a single external interface. The interface is a 7-pin connector Molex Micro-Fit 3.0™ P/N
04365-00722.
The mating connector is the Molex 04645-0700.
Pacific Track has approved the substitution of the Molex connector with other brands that have met a
series of tests conducted internally.
4.2 Pinout
The pinout of the connector is specified is the following table:
PIN
FUNCTION
DETAILS / RANGE
1
UART TX
Accessories UART
Transmit
2
UART RX
Accessories UART Receive
3
OUTPUT
Open Drain Output
4
INPUT 2
3 to 32V
5
INPUT 1
3 to 32V
6
POWER GND
0V
7
POWER IN
6 to 32V
The device should be powered from pins 6 and 7.
4.3 Micro USB
For debugging purpose, the PT10 also includes a Micro USB connector. The connector can be used to
connect USB 2.0 equipment (PC, laptop or smartphone) to the PT10 during provisioning.
PT40 OEM USER MANUAL
Pacific Track, LLC 7
Note that the PT10 cannot be powered from the USB-C connector nor can the connector provide power
to a connected accessory.
5 LED’s
5.1 Overview
The PT10 includes two LEDs (ORANGE and BLUE).
Note: This document describes the current default behavior of the LEDs. This behavior can be changed
by the user.
5.2 ORANGE LED
The following table summarizes the functionality of the ORANGE LED;
Note: The GPS may go into power management mode for example when the PT10 detects that the
vehicle is not moving.
5.3 BLUE LED
The following table summarizes the functionality of the BLUE LED;
6 Power Supply
The PT10 is powered with a circuit that has been tested to meet the requirements of ISO 16750-2.
The circuit provides the following benefit:
LED State
Meaning
Off
GPS power management engaged. GPS is turned
off, GPS backup clock in ON.
Blinking
GPS is in acquisition mode
On
GPS signal is locked
LED State
Meaning
Off
The cellular subsystem is off
One blink / 10s
The cellular subsystem is not searching
Two
blink
s
/ 10s
No SIM
card
detected
Fast blink
The cellular network has rejected the device
Slow Blink
The
cellular subsystem is searching
On
The cellular subsystem found a network
PT40 OEM USER MANUAL
Pacific Track, LLC 8
1) Protected against reversed polarity
2) Protected against over current with a resettable fuse
3) Filtered against noise present on the power line
4) Protected against the overvoltage/overshoot present in the automotive and industrial
environments with a Transient Voltage Suppressor (TVS) which has a peak power dissipation of
1500W
7 Testing Environment
To test the PT10, the following shall be provided:
A reliable power supply (at least one amp at 12V)
A SIM card for the targeted operator
A PC or laptop
A USB cable to connect a PC or laptop to the PT10 such as this one:
8 Software Tools
It is recommended to use a terminal emulation program called Tera Term. The latest version is 4.106
and it can be found at: https://osdn.net/projects/ttssh2/releases/
Do not use other branches of the Tera Term projects such as 2.x or 3.x
9 Initial setup
1. Insert the SIM card in the PT10
2. Power the device
3. Connect the USB connector to the PC/Laptop and to the device
4. Start Tera Term
5. Click on File New Connection Serial and select:
COMxx: Quectel NMEA Port (COMxx)
6. Click OK
7. Click on Setup Serial Port and select the following options:
Speed: 115200
Data: 8 bit
PT40 OEM USER MANUAL
Pacific Track, LLC 9
Parity: none
Stop bits: 1 bit
Flow control: none
8. Click OK
9. It might be convenient to store those settings by going to:
Setup Save setup and click Save
10 Control Interface
At that point the user should be able to enter commands to control and query the device. Note that
there is no echo unless the command character (‘!’) is first entered. To test the interface, type the
following commands:
!H<cr> (<cr> is the carriage return character which is sent when the Enter key is pressed)
11 Cellular Information
11.1 Query normal
The Cellular interface can be queried with the following command:
!CI<cr>
Here below is an example answer to this query:
!CI
Model: BG95
Version: M1
Rev: LAR02A04
IMEI: 359215101130863
SIM
Status: OK
ICCID: 89148000004519458528
NETWORK
Registered: Yes
Roaming: No
RSSI: 21
Socket T: 16386
Socket M: 16385
Network: 311480
LAC: 2B03
CID: 00A90001
PT40 OEM USER MANUAL
Pacific Track, LLC 10
Band: 13
OK
11.2 Query no SIM
If the SIM card is not present or not detected, the following is displayed:
!CI
Model: BG95
Version: M1
Rev: LAR02A04
IMEI: 359215101130863
SIM
Status: No SIM
NETWORK
Registered: No
OK
12 GPS Information
The GPS subsystem can be queried with the following command:
!G<cr>
Here below is an example answer to this query:
GPS STATUS
Mode: Power ON
Lock: 1
Sat U: 11
Sat V: 14
Time: 09/17/2018 22:12:51
Lat: 48.858343
Lon: 2.294705
Spd: 0.0
Hea: 257
Alt: 23
DOP: 0.8
Age: 1 s
RTC: 09/17/2018 22:12:50
Lock: 35
Relock: 35
OK
PT40 OEM USER MANUAL
Pacific Track, LLC 11
13 Input/Outputs
13.1 Overview
The PT10 includes the following interfaces:
1 Digital inputs
1 Open-drain outputs
A serial UART
For debugging purpose, these interfaces can be controlled locally. In actual deployments, these
interfaces can be controlled remotely over an IP connection or SMS messages
13.2 Digital inputs
The inputs can be verified with the following command:
!INP<cr>
The result is as shown below:
2 1
1 0
OK
In that case, inputs 2 is high (more than 3V on the input) and inputs 1 is low.
13.3 Open-drain outputs
The outputs can be controlled with the following command:
!OUT=<OUTPUT>,<LEVEL>
<OUTPUT> is 1
<LEVEL> is 0 or 1 (1 activates the open-drain which grounds the
output))
Example 1: activate output #1:
!OUT=1,1
Example 2: deactivate output #1:
!OUT=1,0
PT40 OEM USER MANUAL
Pacific Track, LLC 12
13.4 Connecting a load
The load can be connected to the PT10 output using the following schematic:
Please note the following:
The POWER applied to the load does not need to be the same as the one powering the PT10
When using separate power sources, the two grounds (PT10 and load) must be connected
together
The diode shown above must be present if the load is not purely resistive. If a non-resistive load
such as a relay is switched without the diode, the PT140 output will be immediately destroyed.
The maximum voltage for the load is 60V (note that this is different from the maximum voltage
supported by the PT10 itself)
The maximum current is 3 Amps.
13.5 Serial interface
Please contact Pacific Track to discuss the supported devices.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Pacific Track PT10 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues