Dish Reflector Antenna Feed Rear Housing
Adjustment Bracket Mounting Bracket Hex Bolts with Washers (Qty.
4)
Pole Clamp Carriage Bolts (Qty. 2) Flange Nuts (Qty. 2)
Gigabit PoE (24V, 0.5A) with Power Cord
Package Contents
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 2/21
Mounting Bracket
Installation Requirements
13 mm wrench
Shielded Category 5 (or above) cabling with drain wire should be used for all wired
Ethernet connections and should be grounded through the AC ground of the PoE.
We recommend that you protect your networks from harmful outdoor
environments and destructive ESD events with industrial-grade, shielded Ethernet
cable from Ubiquiti. For more details, visit ui.com/toughcable
Surge protection should be used for all outdoor installations. We recommend that
you use two Ethernet Surge Protectors, model ETH-SP, one near the PowerBeam
and the other at the entry point to the building. The ETH-SP will absorb power
surges and safely discharge them into the ground.
Hardware Overview
Bottom View
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 3/21
Ethernet
Reset Button
Release Button
This Gigabit Ethernet port is used to connect the power and should be connected
to the LAN and DHCP server.
To reset to factory defaults, press and hold the Reset button for more than 10
seconds while the device is powered on. Alternatively, the device may be reset
remotely via a Reset button located on the bottom of the Gigabit PoE Adapter.
After you assemble the PowerBeam, check the Release button; it should be fully
engaged in the Release Button Slot of the Rear Housing. This ensures that the
Antenna Feed is locked into place. If you need to remove the Antenna Feed, you
must depress the Release button first.
LEDs
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 4/21
Signal
Ethernet
Power
In airOS®, you can modify the threshold value for the wireless signal strength
LEDs on the Wireless tab under Signal LED Thresholds. Each LED will light when
the wireless signal strength is equal to or greater than the LED’s threshold value.
The default threshold values for these LEDs are shown below:
The Ethernet LED will light steady blue when an active Ethernet connection is
made and flash when there is activity.
The Power LED will light blue when the device is connected to a power source.
Application Examples
The PowerBeam mounted outdoors with the Dish Reflector installed provides
directional outdoor coverage (gain is reflector-dependent).
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 5/21
The PowerBeam mounted outdoors without the Dish Reflector installed provides
outdoor-to-indoor coverage using the 3 dBi Antenna Feed only.
Installation
1.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 6/21
2.
3.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 7/21
Note: In high-wind environments, you can add support with additional
hardware (not included):
1. Using the four holes in the Adjustment Bracket as a template, drill four
holes into the Dish Reflector with a 4.4 mm or 11/64" drill bit.
2. Secure the Dish Reflector to the Adjustment Bracket using M4 screws,
washers, and nuts (not included).
4.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 8/21
5.
6.
7.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 9/21
8.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 10/21
9.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 11/21
10.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 12/21
Connecting Power
WARNING: The switch port must comply with the power specifications listed
in the Specifications section of this Quick Start Guide.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 13/21
OR
Optional
Accessing airOS via Wi-Fi
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 14/21
Verify connectivity in the airOS® Configuration Interface using the UNMS™ app or
Web Portal. Both are available for 15 minutes immediately after you power on the
device. If necessary, you can power cycle the device to re-enable its Wi-Fi.
UNMS App
1. Download the UNMS app.
2. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
3. Launch the app and follow the on-screen instructions.
Web Portal
1. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
2. Launch your web browser and go to: http://setup.ui.com
3. Select your Country and Language. You must agree to the Terms of Use to use
the product. Click Continue.
Note: Ensure that DHCP is enabled on your Wi-Fi adapter.
Note: Ensure that your Wi-Fi connection has DHCP enabled.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 15/21
4. Create a username and password. Confirm your new password and then click
Save.
The airOS Configuration Interface will appear, allowing you to customize your
settings as needed. For additional details, refer to the User Guide available at
ui.com/download/airmax-ac
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 16/21
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s
responsibility to make sure the device is operated within local country regulatory
requirements.
Antenna
Select your antenna from the list. If Calculate EIRP Limit is enabled, transmit output
power is automatically adjusted to comply with the regulations of the applicable
country. For a Custom antenna, Antenna Gain is entered manually. Note the
requirements and antenna types listed below.
Cable Loss (When applicable)
Enter the cable loss in dB. Output power is adjusted to compensate for loss between
the radio and the antenna.
Certified Antenna Types
This radio transmitter FCC ID: SWX-PBE2ACN / IC: 6545A-PBE2ACN has been
approved by FCC / ISED Canada to operate with the antenna types listed below with
the maximum permissible gain for each antenna type indicated. Antenna types not
included in this list or having a gain greater than the maximum gain indicated for that
type, are strictly prohibited for use with this device.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 17/21
Antenna Frequency Gain
Dish 2.4 GHz 18 dBi
Specifications
PBE-2AC-400
Dimensions 420 x 420 x 289 mm
(16.54 x 16.54 x 11.38")
Weight (Mount Included) 1.795 kg (3.957 lb)
Gain 18 dBi
Networking Interface (1) 10/100/1000 Ethernet Port
Enclosure Outdoor UV Stabilized Plastic
Max. Power Consumption 7.5W
Power Supply 24V, 0.5A Gigabit PoE Adapter (Included)
Power Method Passive PoE (Pairs 4, 5+; 7, 8 Return)
Wind Survivability 200 km/h (125 mph)
Wind Loading 342.5 N @ 200 km/h (77 lbf @ 125 mph)
Mounting Pole Mounting Kit Included
Operating Temperature -40 to 70° C (-40 to 158° F)
Operating Humidity 5 to 95% Noncondensing
Shock and Vibrations ETSI300-019-1.4
Certifications CE, FCC, IC
Operating Frequency (MHz)
Worldwide 2412 - 2472
US/CA 2412 - 2462
Management Radio (MHz)
Worldwide 5150 - 5250
US/CA U-NII-3 5725 - 5850
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 18/21
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote
risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements
indicated on the manufacturers label. Connection to a different power source than those
specified may result in improper operation, damage to the equipment or pose a fire hazard if
the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided
only by a qualified service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground
wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never
use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the
grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification,
modification or misuse can provide a shock hazard that can result in serious injury or
death.
c. Contact a qualified electrician or the manufacturer if there are questions about the
installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide
appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and
regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis,
and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could
void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 19/21
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operations of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement
This equipment complies with radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 28 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
AVIS IMPORTANT
PBE-2AC-400 Quick Start Guide
15/1/2020 PBE-2AC-400 Quick Start Guide
https://dl.ubnt.com/qsg/PBE-2AC-400/PBE-2AC-400_EN.html 20/21
Déclaration sur l’exposition aux rayonnements
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans
un environnement non contrôlé.
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait
une distance minimale de 28 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre
émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential
environment this equipment may cause radio interference.
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e
não pode causar interferência em sistemas devidamente autorizados.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are
applicable to it.
Country List
AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350
MHz frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may operate at
36 dBm.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
PBE-2AC-400 Quick Start Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Ubiquiti PBE-2AC-400 Guide de démarrage rapide

Taper
Guide de démarrage rapide

dans d''autres langues